António Domingos Reis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
António Domingos Reis has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- José Alberto Ribeiro Pacheco Carvalho
Universidade da Beira Interior
47 shared publications - Atilio Gameiro
Instituto de Telecomunicações (IT), Departamento de Electrónica, Telecomunicações e Informática (DETI), Universidade de Aveiro, 3810-193 Aveiro, Portugal
33 shared publications - José Rodrigues Ferreira da Rocha
Dep. de Electrónica e Telecomunicações / Instituto de Telecomunicações, Universidade de Aveiro, 3810, Portugal
30 shared publications H. Veiga
Unidade de Detecção Remota, Universidade da Beira Interior, 6201-001 Covilhã, Portugal
14 shared publicationsN. Marques
Universidade da Beira Interior
10 shared publications- C. F. Ribeiro Pacheco
Unidade de Detecção Remota, Universidade da Beira Interior, 6201-001 Covilhã, Portugal
9 shared publications
Latest Publications
- 27 September 2026
- Published by Springer Nature in Evolutionary Intelligence
- Vol. 19 (5) , 150
Inertial and wearable sensor-based instrumented sit-to-stand assessment: a scoping review with consideration of multimodal approaches
- 27 September 2026
- Published by Springer Nature in Evolutionary Intelligence
- Vol. 19 (5) , 150
Inertial and wearable sensor-based instrumented sit-to-stand assessment: a scoping review with consideration of multimodal approaches
- 19 August 2026
- Published by Springer Nature in Biomedical Materials & Devices
- p. 1-31
Wearable Sweat Sensors for Real-Time Hydration and Performance Monitoring in Athletes: A Systematic Review
- 19 August 2026
- Published by Springer Nature in Biomedical Materials & Devices
- p. 1-31
Wearable Sweat Sensors for Real-Time Hydration and Performance Monitoring in Athletes: A Systematic Review
- Open Access
Radio Coverage Assessment and Indoor Communication Enhancement in Hospitals: A Case Study at CHUCB
The adoption of wireless medical technologies in hospital environments is often limited by cellular coverage issues, especially in indoor areas with complex structures. This study presents a detailed radio spectrum measurement campaign conducted at the Cova da Beira University Hospital Center (CHUCB), using the NARDA SRM-3006 and R&S®TSME6 equipment. The signal strength and quality of 5G NR, LTE, UMTS, and NB-IoT technologies were evaluated. Critical coverage gaps were identified, particularly at points 17, 19, and 21. Results revealed that operators MEO and NOS dominate coverage, with MEO providing better 5G NR coverage and NOS excelling in LTE signal quality. Based on the results, the localized installation of femtocells is proposed to improve coverage in these areas. The approach was designed to be scalable and replicable, with a planned application at Cumura Hospital (Guinea-Bissau), reinforcing the applicability of the solution in contexts with limited infrastructure. This work provides both technical and clinical contributions to achieving ubiquitous cellular coverage in healthcare settings.
Open AccessRadio Coverage Assessment and Indoor Communication Enhancement in Hospitals: A Case Study at CHUCB
The adoption of wireless medical technologies in hospital environments is often limited by cellular coverage issues, especially in indoor areas with complex structures. This study presents a detailed radio spectrum measurement campaign conducted at the Cova da Beira University Hospital Center (CHUCB), using the NARDA SRM-3006 and R&S®TSME6 equipment. The signal strength and quality of 5G NR, LTE, UMTS, and NB-IoT technologies were evaluated. Critical coverage gaps were identified, particularly at points 17, 19, and 21. Results revealed that operators MEO and NOS dominate coverage, with MEO providing better 5G NR coverage and NOS excelling in LTE signal quality. Based on the results, the localized installation of femtocells is proposed to improve coverage in these areas. The approach was designed to be scalable and replicable, with a planned application at Cumura Hospital (Guinea-Bissau), reinforcing the applicability of the solution in contexts with limited infrastructure. This work provides both technical and clinical contributions to achieving ubiquitous cellular coverage in healthcare settings.
- Open Access
- 2 June 2020
- Published by Knowledge E DMCC in KnE Engineering
- p. 645–654
Coder and Decoder of Block 3B4B with Auxiliary Channel
This work presents the coder and decoder of block 3B4B with auxiliary channel. The coder 3B4B converts an input 3 bits word in an output 4 bits word. It transmits an equal number of 1’s and 0’s to provide a DC constant component. It increases the transitions number, improves the system quality and security. The objective is also to improve the system potentialities with an auxiliary channel to monitor the communication (alarm). The main channel is real, but the auxiliary channel is fictitious. Keywords: Block codes, Digital systems, Transmission lines
- 2 June 2020
- Published by Knowledge E DMCC in KnE Engineering
- p. 645–654
Open AccessCoder and Decoder of Block 3B4B with Auxiliary Channel
This work presents the coder and decoder of block 3B4B with auxiliary channel. The coder 3B4B converts an input 3 bits word in an output 4 bits word. It transmits an equal number of 1’s and 0’s to provide a DC constant component. It increases the transitions number, improves the system quality and security. The objective is also to improve the system potentialities with an auxiliary channel to monitor the communication (alarm). The main channel is real, but the auxiliary channel is fictitious. Keywords: Block codes, Digital systems, Transmission lines
- Open Access
- 14 November 2019
- Published by Colegio Mexicano de Inmunologia Clinica y Alergia, A. C. in Revista Alergia México
- Vol. 66 (4) , 488-492
Manifestaciones clínicas y diagnóstico tardío de la inmunodeficiencia común variable
Background: Common Variable Immunodeficiency (CVID) is the most frequent type of severe primary immunodeficiency (PID). Clinical manifestations of CVID occur at any age; nevertheless, they are more frequent between the age of 6 and 10 years, and between the age of 20 and 40 years. In medical literature, there are hardly any diagnostic reports on CVID after 50 years of age.Clinical case: A 58-year-old man with a clinical history of repeated infections since the age of 35. The tests showed a decrease in IgG, IgA, and specific antibodies, without any other causes of hypogammaglobulinemia. The CVID diagnosis was made and the patient received treatment with human immunoglobulin replacement and a reinforcement of personal and environmental hygiene. The patient stopped presenting repeated infections.Conclusion: Diagnoses made after the age of 50, although they’re late, they are fundamental to the recovery of the patient. In the referred case, replacement with human immunoglobulin allowed an improvement in the quality of life.
- 14 November 2019
- Published by Colegio Mexicano de Inmunologia Clinica y Alergia, A. C. in Revista Alergia México
- Vol. 66 (4) , 488-492
Open AccessManifestaciones clínicas y diagnóstico tardío de la inmunodeficiencia común variable
Background: Common Variable Immunodeficiency (CVID) is the most frequent type of severe primary immunodeficiency (PID). Clinical manifestations of CVID occur at any age; nevertheless, they are more frequent between the age of 6 and 10 years, and between the age of 20 and 40 years. In medical literature, there are hardly any diagnostic reports on CVID after 50 years of age.Clinical case: A 58-year-old man with a clinical history of repeated infections since the age of 35. The tests showed a decrease in IgG, IgA, and specific antibodies, without any other causes of hypogammaglobulinemia. The CVID diagnosis was made and the patient received treatment with human immunoglobulin replacement and a reinforcement of personal and environmental hygiene. The patient stopped presenting repeated infections.Conclusion: Diagnoses made after the age of 50, although they’re late, they are fundamental to the recovery of the patient. In the referred case, replacement with human immunoglobulin allowed an improvement in the quality of life.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Groups of synchronizers for communications by fiber optic
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Groups of synchronizers for communications by fiber optic
- 1 July 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Prefilter bandwidth effects in asynchronous sequential symbol synchronizers based on pulse comparison operating by positive transitions at half bit rate
This work investigates the prefilter bandwidth effects in four asynchronous sequential bit synchronizers. The prefilter bandwidth is changed between three discrete values, namely B1=∞, B2=2.tx and B3=1.tx, where tx is the bit rate. The synchronizers distinguish 2 variants, one asynchronous by both transitions at rate and other asynchronous by positive transitions at half rate. Each variant has two versions which are the manual and the automatic. The objective is to study the three prefilter bandwidths with the four synchronizers and to evaluate their output jitter UIRMS (Unit Interval Root Mean Square) as function of the input SNR (Signal Noise Ratio).
- 1 July 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Prefilter bandwidth effects in asynchronous sequential symbol synchronizers based on pulse comparison operating by positive transitions at half bit rate
This work investigates the prefilter bandwidth effects in four asynchronous sequential bit synchronizers. The prefilter bandwidth is changed between three discrete values, namely B1=∞, B2=2.tx and B3=1.tx, where tx is the bit rate. The synchronizers distinguish 2 variants, one asynchronous by both transitions at rate and other asynchronous by positive transitions at half rate. Each variant has two versions which are the manual and the automatic. The objective is to study the three prefilter bandwidths with the four synchronizers and to evaluate their output jitter UIRMS (Unit Interval Root Mean Square) as function of the input SNR (Signal Noise Ratio).
- 1 January 2015
- Published by Springer Nature
- p. 563-572
Extended Performance Studies of Wi-Fi IEEE 802.11 A, B, G Laboratory Wep Point-to-Multipoint and Point-to-Point Links
- 1 January 2015
- Published by Springer Nature
- p. 563-572
Extended Performance Studies of Wi-Fi IEEE 802.11 A, B, G Laboratory Wep Point-to-Multipoint and Point-to-Point Links
- 27 April 2014
- Published by Springer Nature
- p. 455-465
Extended Performance Studies of Wi-Fi IEEE 802.11a, b, g Laboratory WPA Point-to-Multipoint and Point-to-Point Links
- 27 April 2014
- Published by Springer Nature
- p. 455-465
Extended Performance Studies of Wi-Fi IEEE 802.11a, b, g Laboratory WPA Point-to-Multipoint and Point-to-Point Links
- 1 July 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Comparative performance studies of laboratory WPA IEEE 802.11g point-to-point links
Wireless communications using microwaves are increasingly important, e.g. Wi-Fi. Performance is a very important issue, resulting in more reliable and efficient communications. Security is equally very important. Laboratory measurements are made about several performance aspects of Wi-Fi IEEE 802.11g WPA point-to-point links. A contribution is given to performance evaluation of this technology under WPA encryption, using available wireless routers from Linksys (WRT54GL). Detailed results are presented and discussed, namely at OSI levels 4 and 7, from TCP, UDP and FTP experiments, permitting measurements of TCP throughput, jitter, percentage datagram loss and FTP transfer rate. Comparisons are made to corresponding results obtained for, mainly, open links. Conclusions are drawn about the comparative performance of the links.
- 1 July 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Comparative performance studies of laboratory WPA IEEE 802.11g point-to-point links
Wireless communications using microwaves are increasingly important, e.g. Wi-Fi. Performance is a very important issue, resulting in more reliable and efficient communications. Security is equally very important. Laboratory measurements are made about several performance aspects of Wi-Fi IEEE 802.11g WPA point-to-point links. A contribution is given to performance evaluation of this technology under WPA encryption, using available wireless routers from Linksys (WRT54GL). Detailed results are presented and discussed, namely at OSI levels 4 and 7, from TCP, UDP and FTP experiments, permitting measurements of TCP throughput, jitter, percentage datagram loss and FTP transfer rate. Comparisons are made to corresponding results obtained for, mainly, open links. Conclusions are drawn about the comparative performance of the links.