Emanuele Leonardi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Emanuele Leonardi has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
- Crisostomo Sciacca
INFN Sezione di Napoli
128 shared publications - Gerhard Raven
Nikhef National Institute for Subatomic Physics and VU University Amsterdam
123 shared publications F. Ferroni
115 shared publications- Luca Lista
INFN Sezione di Napoli
112 shared publications D. Piccolo
105 shared publications- Egidio Longo
INFN Sezione di Roma
103 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (09) , P09015
Design and beam-test characterization of the CRILIN semi-homogeneous crystal calorimeter
CRILIN is a high-granularity semi-homogeneous electromagnetic calorimeter based on longitudinally segmented PbF 2 crystal matrices read out by UV-extended silicon photomultipliers. The concept combines fast Cherenkov response, fine transverse granularity, longitudinal shower information, and radiation tolerance for future lepton-collider experiments. This paper reports the construction of a large-area prototype and its performance measured in beam tests at the CERN SPS. The detector comprises five 7 × 7 PbF 2 crystal matrices, has a depth of about 22 X 0 , and is read out by four 3 × 3 mm 2 SiPMs per crystal integrated in a single electronic channel. Electron data between 10 and 120 GeV and dedicated 150 GeV muon data were used to characterize the detector response. A time resolution below 50 ps is achieved for electron energies above 10 GeV, reaching values below 20 ps above 60 GeV. The energy resolution is described by a stochastic term of (6.58±0.04)%/√( E /GeV) and a constant term of (0.23±0.02)%, with an additional noise contribution fixed from pedestal data. The longitudinal segmentation enables event-by-event corrections based on the reconstructed shower development, resulting in a significant improvement of the energy resolution. A light yield of approximately 0.54 photoelectrons/MeV is measured consistently using both electron showers and minimum-ionizing particles. A Geant4-based simulation incorporating the relevant experimental effects reproduces the measured energy resolution. These results validate the CRILIN architecture as a compact, fast, and longitudinally segmented electromagnetic calorimeter for future collider experiments.
- 1 September 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (09) , P09015
Open AccessDesign and beam-test characterization of the CRILIN semi-homogeneous crystal calorimeter
CRILIN is a high-granularity semi-homogeneous electromagnetic calorimeter based on longitudinally segmented PbF 2 crystal matrices read out by UV-extended silicon photomultipliers. The concept combines fast Cherenkov response, fine transverse granularity, longitudinal shower information, and radiation tolerance for future lepton-collider experiments. This paper reports the construction of a large-area prototype and its performance measured in beam tests at the CERN SPS. The detector comprises five 7 × 7 PbF 2 crystal matrices, has a depth of about 22 X 0 , and is read out by four 3 × 3 mm 2 SiPMs per crystal integrated in a single electronic channel. Electron data between 10 and 120 GeV and dedicated 150 GeV muon data were used to characterize the detector response. A time resolution below 50 ps is achieved for electron energies above 10 GeV, reaching values below 20 ps above 60 GeV. The energy resolution is described by a stochastic term of (6.58±0.04)%/√( E /GeV) and a constant term of (0.23±0.02)%, with an additional noise contribution fixed from pedestal data. The longitudinal segmentation enables event-by-event corrections based on the reconstructed shower development, resulting in a significant improvement of the energy resolution. A light yield of approximately 0.54 photoelectrons/MeV is measured consistently using both electron showers and minimum-ionizing particles. A Geant4-based simulation incorporating the relevant experimental effects reproduces the measured energy resolution. These results validate the CRILIN architecture as a compact, fast, and longitudinally segmented electromagnetic calorimeter for future collider experiments.
- Open Access
- 27 December 2025
- Published by Elsevier in Physics Letters B
- Vol. 872
Search for heavy neutral leptons in π + decays to positrons
- 27 December 2025
- Published by Elsevier in Physics Letters B
- Vol. 872
Open AccessSearch for heavy neutral leptons in π + decays to positrons
- Open Access
- 24 November 2025
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2025 (11) , 143
Searches for hidden sectors using K+ → π+X decays
A bstract: Results from the study of the rare decays $$ {K}^{+}\to {\pi}^{+}\nu \overline{\nu} $$ , K + → π + μ + μ − and K + → π + γγ at the NA62 experiment at CERN are interpreted in terms of improved limits for $$ \mathcal{B}\left({K}^{+}\to {\pi}^{+}X\right) $$ and coupling parameters of hidden-sector models, where X is a mediator. World-leading limits are achieved for dark photon, dark scalar and axion-like particle models.- 24 November 2025
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2025 (11) , 143
Open AccessSearches for hidden sectors using K+ → π+X decays
A bstract: Results from the study of the rare decays $$ {K}^{+}\to {\pi}^{+}\nu \overline{\nu} $$ , K + → π + μ + μ − and K + → π + γγ at the NA62 experiment at CERN are interpreted in terms of improved limits for $$ \mathcal{B}\left({K}^{+}\to {\pi}^{+}X\right) $$ and coupling parameters of hidden-sector models, where X is a mediator. World-leading limits are achieved for dark photon, dark scalar and axion-like particle models. - Top Cited PapersOpen Access
- 4 November 2025
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2025 (11) , 1-31
Search for a new 17 MeV resonance via e+e− annihilation with the PADME experiment
A bstract: The PADME Experiment at the Frascati DAΦNE linear accelerator has searched for a hypothetical particle with mass around 17 MeV, commonly referred to as the X17, using a positron beam incident on a fixed target. The beam energy was varied between 262 and 296 MeV, corresponding to center-of-mass energies $$\sqrt{s}$$ between 16.4 and 17.4 MeV. The X17 should be produced resonantly via e + e − annihilation when $$\sqrt{s}$$ approaches its mass, inducing an excess of events with a two-body final state over the background expectation. The beam energy spacing was fixed to less than half the expected width of the resonance’s line shape. Uncertainties below 1% per $$\sqrt{s}$$ point were achieved. A blind analysis has been performed. The data are consistent with the expected background in most of the explored energy range, and limits are set in previously unexplored regions of the available parameter space. The most significant deviation is found for $$\sqrt{s}\approx 16.90$$ MeV, corresponding to a global significance of approximately 2 standard deviations over the null hypothesis expectation.- 4 November 2025
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2025 (11) , 1-31
Top Cited PapersOpen AccessSearch for a new 17 MeV resonance via e+e− annihilation with the PADME experiment
A bstract: The PADME Experiment at the Frascati DAΦNE linear accelerator has searched for a hypothetical particle with mass around 17 MeV, commonly referred to as the X17, using a positron beam incident on a fixed target. The beam energy was varied between 262 and 296 MeV, corresponding to center-of-mass energies $$\sqrt{s}$$ between 16.4 and 17.4 MeV. The X17 should be produced resonantly via e + e − annihilation when $$\sqrt{s}$$ approaches its mass, inducing an excess of events with a two-body final state over the background expectation. The beam energy spacing was fixed to less than half the expected width of the resonance’s line shape. Uncertainties below 1% per $$\sqrt{s}$$ point were achieved. A blind analysis has been performed. The data are consistent with the expected background in most of the explored energy range, and limits are set in previously unexplored regions of the available parameter space. The most significant deviation is found for $$\sqrt{s}\approx 16.90$$ MeV, corresponding to a global significance of approximately 2 standard deviations over the null hypothesis expectation. - Open Access
- 4 June 2025
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2025 (6) , 1-16
Blind unblinding procedure for the PADME X17 data sample
The PADME experiment at the Frascati DAΦNE LINAC has performed a search for the hypothetical X17 particle, with a mass of around 17 MeV, by scanning the energy of a positron beam striking a fixed target. The X17 should be produced from the resulting e + e − annihilation. Since the expected mass of this particle is only roughly known, data sidebands cannot be clearly defined. Furthermore, the need to keep the analysis blind to potentially sizable signal contributions prevents a clear assessment even of the quality of the data sample in this search. In light of these challenges, this paper presents an innovative strategy adopted by the PADME Collaboration to perform data quality checks without disclosing the X17 sample. Moreover, the procedure designed to eventually unblind the data is described, together with the statistical approach adopted to extract the limits on the coupling between the X17 and the Standard Model.
- 4 June 2025
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2025 (6) , 1-16
Open AccessBlind unblinding procedure for the PADME X17 data sample
The PADME experiment at the Frascati DAΦNE LINAC has performed a search for the hypothetical X17 particle, with a mass of around 17 MeV, by scanning the energy of a positron beam striking a fixed target. The X17 should be produced from the resulting e + e − annihilation. Since the expected mass of this particle is only roughly known, data sidebands cannot be clearly defined. Furthermore, the need to keep the analysis blind to potentially sizable signal contributions prevents a clear assessment even of the quality of the data sample in this search. In light of these challenges, this paper presents an innovative strategy adopted by the PADME Collaboration to perform data quality checks without disclosing the X17 sample. Moreover, the procedure designed to eventually unblind the data is described, together with the statistical approach adopted to extract the limits on the coupling between the X17 and the Standard Model.
- Open Access
- 12 November 2024
- Published by Elsevier in Physics Letters B
- Vol. 859
First search for K+ → π0πμe decays
- 12 November 2024
- Published by Elsevier in Physics Letters B
- Vol. 859
Open AccessFirst search for K+ → π0πμe decays
- Open Access
- 16 August 2024
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2024 (8) , 1-23
Characterization of the PADME positron beam for the X17 measurement
A bstract: This paper presents a detailed characterization of the positron beam delivered by the Beam Test Facility at Laboratori Nazionali of Frascati to the PADME experiment during Run III, which took place from October to December 2022. It showcases the methodology used to measure the main beam parameters such as the position in space, the absolute momentum scale, the beam energy spread, and its intensity through a combination of data analysis and Monte Carlo simulations. The results achieved include an absolute precision in the momentum of the beam to within ~1–2 MeV /c , a relative beam energy spread below 0.25%, and an absolute precision in the intensity of the beam at the level of 2%.
- 16 August 2024
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2024 (8) , 1-23
Open AccessCharacterization of the PADME positron beam for the X17 measurement
A bstract: This paper presents a detailed characterization of the positron beam delivered by the Beam Test Facility at Laboratori Nazionali of Frascati to the PADME experiment during Run III, which took place from October to December 2022. It showcases the methodology used to measure the main beam parameters such as the position in space, the absolute momentum scale, the beam energy spread, and its intensity through a combination of data analysis and Monte Carlo simulations. The results achieved include an absolute precision in the momentum of the beam to within ~1–2 MeV /c , a relative beam energy spread below 0.25%, and an absolute precision in the intensity of the beam at the level of 2%.