James Rezende Piton
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
James Rezende Piton has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Santiago Jose Alejandro Figueroa
Brazilian Synchrotron Light Laboratory (LNLS), Brazilian Center for Research in Energy and Materials (CNPEM), Campinas (13083-970), SP, Brazil
2 shared publications A F A G Moreira
1 shared publicationA M Espíndola
Centro Nacional de Pesquisa em Energia e Materials (CNPEM), Laboratório Nacional de Luz Síncrotron (LNLS), Rua Giuseppe Máximo Scolfaro, 10.000, Polo II de Alta Tecnologia, Caixa Postal 6192, 13083- 970 Campinas, SP, Brazil
1 shared publicationA Naves de Brito
State University of Campinas
1 shared publicationA P S Levinsky
Centro Nacional de Pesquisa em Energia e Materials (CNPEM), Laboratório Nacional de Luz Síncrotron (LNLS), Rua Giuseppe Máximo Scolfaro, 10.000, Polo II de Alta Tecnologia, Caixa Postal 6192, 13083- 970 Campinas, SP, Brazil
1 shared publicationA R B de Castro
State University of Campinas
1 shared publication
Latest Publications
- Open Access
- 9 June 2026
- Published by MDPI AG in Instruments
- Vol. 10 (2) , 32
High-Resolution Quad-Channel Picoammeter: Characterization and Commissioning
To address the high demand for precise low-current measurements at the Sirius’ beamlines, a quad-channel high-resolution Ethernet picoammeter has been designed. The instrument can measure currents ranging from femtoampere to milliampere across eight selectable ranges, featuring integrated analog-to-digital converters (ADCs), enabling sampling rates of up to 2 ksps and synchronization capabilities. This work describes the hardware design, the hardware handling procedures to achieve sub-picoampere resolution, and the characterization results of the instrument, considering the experimental results from Sirius beamlines. The designed device provides noise performance and gain accuracy that is comparable to high-end commercial solutions, proving its suitability for critical applications like on-the-fly scanning experiments. Special attention will be given to evaluating trigger latency, synchronization outcomes, as well as the device’s installation and commissioning at beamlines. Furthermore, we will deeply explore the interplay between the trigger period, digital filter bandwidth, and front-end analog bandwidth to optimize the signal-to-noise ratio in specific applications. The hardware project is publicly available in CERN’s open hardware repository.
- 9 June 2026
- Published by MDPI AG in Instruments
- Vol. 10 (2) , 32
Open AccessHigh-Resolution Quad-Channel Picoammeter: Characterization and Commissioning
To address the high demand for precise low-current measurements at the Sirius’ beamlines, a quad-channel high-resolution Ethernet picoammeter has been designed. The instrument can measure currents ranging from femtoampere to milliampere across eight selectable ranges, featuring integrated analog-to-digital converters (ADCs), enabling sampling rates of up to 2 ksps and synchronization capabilities. This work describes the hardware design, the hardware handling procedures to achieve sub-picoampere resolution, and the characterization results of the instrument, considering the experimental results from Sirius beamlines. The designed device provides noise performance and gain accuracy that is comparable to high-end commercial solutions, proving its suitability for critical applications like on-the-fly scanning experiments. Special attention will be given to evaluating trigger latency, synchronization outcomes, as well as the device’s installation and commissioning at beamlines. Furthermore, we will deeply explore the interplay between the trigger period, digital filter bandwidth, and front-end analog bandwidth to optimize the signal-to-noise ratio in specific applications. The hardware project is publicly available in CERN’s open hardware repository.
- Open Access
- 26 June 2018
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 25 (4) , 953-959
Steps towards XAFS beamline automation and remote access
Although remote access to beamline synchrotron facilities is now a common operation mode at macromolecular crystallography beamlines thanks to substantial efforts in automated processes for sample preparation and handling, experiment planning and analysis, this is still not the case for XAFS beamlines. Here the experience and developments undertaken at LNLS and Diamond in automation are described, in an attempt to tackle the specific challenges posed by the high variability in experimental conditions and configurations that XAFS measurements require.
- 26 June 2018
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 25 (4) , 953-959
Open AccessSteps towards XAFS beamline automation and remote access
Although remote access to beamline synchrotron facilities is now a common operation mode at macromolecular crystallography beamlines thanks to substantial efforts in automated processes for sample preparation and handling, experiment planning and analysis, this is still not the case for XAFS beamlines. Here the experience and developments undertaken at LNLS and Diamond in automation are described, in an attempt to tackle the specific challenges posed by the high variability in experimental conditions and configurations that XAFS measurements require.
- Open Access
- 1 May 2016
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 712 (1) , 012022
Upgrades to the XAFS2 beamline control system and to the endstation at the LNLS
The XAFS2 is a general-purpose X-ray absorption beamline. It is the second one built at the LNLS. After approximately 7 years in operation this beamline has been substantially updated in order to improve its experimental possibilities. Recently arrived, a 4circle Huber diffractometer has been incorporated to perform combined experiments. This collects XRD patterns with the XAFS. Through the development of a new sampling environment it is now also possible to perform these measurements in situ/operando conditions. Other upgrades include a complete remodelling of the beamline software and its control system. The following new systems are crucial for the next steps that are currently underway at the beamline, namely, (i) enabling remote access for users and (ii) the testing of QEXAFS measurements.
- 1 May 2016
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 712 (1) , 012022
Open AccessUpgrades to the XAFS2 beamline control system and to the endstation at the LNLS
The XAFS2 is a general-purpose X-ray absorption beamline. It is the second one built at the LNLS. After approximately 7 years in operation this beamline has been substantially updated in order to improve its experimental possibilities. Recently arrived, a 4circle Huber diffractometer has been incorporated to perform combined experiments. This collects XRD patterns with the XAFS. Through the development of a new sampling environment it is now also possible to perform these measurements in situ/operando conditions. Other upgrades include a complete remodelling of the beamline software and its control system. The following new systems are crucial for the next steps that are currently underway at the beamline, namely, (i) enabling remote access for users and (ii) the testing of QEXAFS measurements.
- 6 August 2015
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 22 (5) , 1182-1189
Py4Syn: Python for synchrotrons
In this report,Py4Syn, an open-source Python-based library for data acquisition, device manipulation, scan routines and other helper functions, is presented. Driven by easy-to-use and scalability ideals,Py4Synoffers control system agnostic solution and high customization level for scans and data output, covering distinct techniques and facilities. Here, most of the library functionalities are described, examples of use are shown and ideas for future implementations are presented.
- 6 August 2015
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 22 (5) , 1182-1189
Py4Syn: Python for synchrotrons
In this report,Py4Syn, an open-source Python-based library for data acquisition, device manipulation, scan routines and other helper functions, is presented. Driven by easy-to-use and scalability ideals,Py4Synoffers control system agnostic solution and high customization level for scans and data output, covering distinct techniques and facilities. Here, most of the library functionalities are described, examples of use are shown and ideas for future implementations are presented.
- 22 March 2013
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 425 (7)
The U11 PGM beam line at the Brazilian National Synchrotron Light Laboratory
- 22 March 2013
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 425 (7)
The U11 PGM beam line at the Brazilian National Synchrotron Light Laboratory
- 27 November 2008
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 16 (1) , 69-75
The MX2 macromolecular crystallography beamline: a wiggler X-ray source at the LNLS
The Brazilian Synchrotron Light Laboratory [Laboratório Nacional de Luz Síncrotron (LNLS), Campinas, SP, Brazil] is the first commissioned synchrotron light source in the southern hemisphere. The first wiggler macromolecular crystallography beamline (MX2) at the LNLS has been recently constructed and brought into operation. Here the technical design, experimental set-up, parameters of the beamline and the first experimental results obtained at MX2 are described. The beamline operates on a 2.0 T hybrid 30-pole wiggler, and its optical layout includes collimating mirror, Si(111) double-crystal monochromator and toroidal bendable mirror. The measured flux density at the sample position at 8.7 eV reaches 4.8 x 10(11) photons s(-1) mm(-2) (100 mA)(-1). The beamline is equipped with a MarResearch Desktop Beamline Goniostat (MarDTB) and 3 x 3 MarMosaic225 CCD detector, and is controlled by a customized version of the Blu-Ice software. A description of the first X-ray diffraction data sets collected at the MX2 LNLS beamline and used for macromolecular crystal structure solution is also provided.
- 27 November 2008
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 16 (1) , 69-75
The MX2 macromolecular crystallography beamline: a wiggler X-ray source at the LNLS
The Brazilian Synchrotron Light Laboratory [Laboratório Nacional de Luz Síncrotron (LNLS), Campinas, SP, Brazil] is the first commissioned synchrotron light source in the southern hemisphere. The first wiggler macromolecular crystallography beamline (MX2) at the LNLS has been recently constructed and brought into operation. Here the technical design, experimental set-up, parameters of the beamline and the first experimental results obtained at MX2 are described. The beamline operates on a 2.0 T hybrid 30-pole wiggler, and its optical layout includes collimating mirror, Si(111) double-crystal monochromator and toroidal bendable mirror. The measured flux density at the sample position at 8.7 eV reaches 4.8 x 10(11) photons s(-1) mm(-2) (100 mA)(-1). The beamline is equipped with a MarResearch Desktop Beamline Goniostat (MarDTB) and 3 x 3 MarMosaic225 CCD detector, and is controlled by a customized version of the Blu-Ice software. A description of the first X-ray diffraction data sets collected at the MX2 LNLS beamline and used for macromolecular crystal structure solution is also provided.
- 14 November 2002
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 822-824
Control and diagnostic systems for the LNLS 500-MeV booster synchrotron
- 14 November 2002
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 822-824
Control and diagnostic systems for the LNLS 500-MeV booster synchrotron