CCCalum Crake

Calum Crake

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Calum Crake has a total of 62 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Improved Therapeutic Antibody Delivery to Xenograft Tumors Using Cavitation Nucleated by Gas-Entrapping Nanoparticles

    by Megan Grundy, Luca Bau, Claudia Hill, Catherine Paverd, Christophoros Mannaris, James Kwan, Calum Crake, Christian Coviello, Constantin Coussios, Robert Carlisle

    Aims: Testing ultrasound-mediated cavitation for enhanced delivery of the therapeutic antibody cetuximab to tumors in a mouse model. Methods: Tumors with strong EGF receptor expression were grown b...


  • Passive acoustic mapping and B-mode ultrasound imaging utilizing compressed sensing for real-time monitoring of cavitation-enhanced drug delivery

    by Calum Crake, Seán Finn, Laurent Marsac, Michael Gray, Robert Carlisle, Constantin Coussios, Christian Coviello

    Ultrasound imaging presents a high-speed, low-cost approach for monitoring of focused ultrasound (FUS) therapy, and includes both conventional (B-mode) sonography and passive acoustic mapping (PAM) of acoustic emissions (Gyöngy et al., 2010, Salgaonkar et al., 2009). Incorporation of novel algorithms and other signal processing techniques have improved the resolution and processing speed of PAM. However, while hardware developments such as increasing channel counts provide unprecedented data capture ability, real-time processing of the growing data stream presents an evolving challenge. Previous work has employed sparse array processing techniques for PAM including matching and basis pursuit (Gyöngy & Coviello, 2011) and co-array processing (Coviello et al, 2012). Here we propose to extend PAM utilizing compressed sensing (CS). Acoustic emissions from FUS may be sparse in several domains, e.g. due to limited regions of space and time in which cavitation is likely from a focused transducer, and correlation between sensors. By exploiting this sparsity, CS allows recovery of signals sampled well below the Nyquist limit. CS-PAM thus facilitates PAM with improved spatial resolution compared to conventional methods, from fewer measurements, allowing improved image quality and reduced computational load. The technique was demonstrated for monitoring of FUS-mediated drug delivery in a murine tumor model.


  • Open Access

    A dual-mode hemispherical sparse array for 3D passive acoustic mapping and skull localization within a clinical MRI guided focused ultrasound device

    by Calum Crake, Spencer T Brinker, Christian M Coviello, Margaret S Livingstone, Nathan J McDannold

    Previous work has demonstrated that passive acoustic imaging may be used alongside MRI for monitoring of focused ultrasound therapy. However, past implementations have generally made use of either linear arrays originally designed for diagnostic imaging or custom narrowband arrays specific to in-house therapeutic transducer designs, neither of which is fully compatible with clinical MR-guided focused ultrasound (MRgFUS) devices. Here we have designed an array which is suitable for use within an FDA-approved MR-guided transcranial focused ultrasound device, within the bore of a 3 Tesla clinical MRI scanner. The array is constructed from 5 × 0.4 mm piezoceramic disc elements arranged in pseudorandom fashion on a low-profile laser-cut acrylic frame designed to fit between the therapeutic elements of a 230 kHz InSightec ExAblate 4000 transducer. By exploiting thickness and radial resonance modes of the piezo discs the array is capable of both B-mode imaging at 5 MHz for skull localization, as well as passive reception at the second harmonic of the therapy array for detection of cavitation and 3D passive acoustic imaging. In active mode, the array was able to perform B-mode imaging of a human skull, showing the outer skull surface with good qualitative agreement with MR imaging. Extension to 3D showed the array was able to locate the skull within ±2 mm/2° of reference points derived from MRI, which could potentially allow registration of a patient to the therapy system without the expense of real-time MRI. In passive mode, the array was able to resolve a point source in 3D within a ±10 mm region about each axis from the focus, detect cavitation (SNR ~ 12 dB) at burst lengths from 10 cycles to continuous wave, and produce 3D acoustic maps in a flow phantom. Finally, the array was used to detect and map cavitation associated with microbubble activity in the brain in nonhuman primates.


  • Combined passive acoustic mapping and magnetic resonance thermometry for monitoring phase-shift nanoemulsion enhanced focused ultrasound therapy

    by Calum Crake, F Can Meral, Mark T Burgess, Iason T Papademetriou, Nathan J McDannold, Tyrone M Porter

    Focused ultrasound (FUS) has the potential to enable precise, image-guided noninvasive surgery for the treatment of cancer in which tumors are identified and destroyed in a single integrated procedure. However, success of the method in highly vascular organs has been limited due to heat losses to perfusion, requiring development of techniques to locally enhance energy absorption and heating. In addition, FUS procedures are conventionally monitored using MRI, which provides excellent anatomical images and can map temperature, but is not capable of capturing the full gamut of available data such as the acoustic emissions generated during this inherently acoustically-driven procedure. Here, we employed phase-shift nanoemulsions (PSNE) embedded in tissue phantoms to promote cavitation and hence temperature rise induced by FUS. In addition, we incorporated passive acoustic mapping (PAM) alongside simultaneous MR thermometry in order to visualize both acoustic emissions and temperature rise, within the bore of a full scale clinical MRI scanner. Focal cavitation of PSNE could be resolved using PAM and resulted in accelerated heating and increased the maximum elevated temperature measured via MR thermometry compared to experiments without nanoemulsions. Over time, the simultaneously acquired acoustic and temperature maps show translation of the focus of activity towards the FUS transducer, and the magnitude of the increase in cavitation and focal shift both increased with nanoemulsion concentration. PAM results were well correlated with MRI thermometry and demonstrated greater sensitivity, with the ability to detect cavitation before enhanced heating was observed. The results suggest that PSNE could be beneficial for enhancement of thermal focused ultrasound therapies and that PAM could be a critical tool for monitoring this process.


  • A dual mode hemispherical sparse array for B-mode skull localization and passive acoustic mapping within a clinical MRI guided focused ultrasound platform

    by Calum Crake, Spencer Brinker, Nathan McDannold

    Previous work has demonstrated that passive acoustic imaging may be used alongside MRI for monitoring of focused ultrasound therapy. However, current implementations have generally made use of either linear arrays originally designed for diagnostic imaging or custom narrowband arrays specific to in-house therapeutic transducer designs, neither of which is fully compatible with clinical MR-guided focused ultrasound devices. Here we have designed an array which is suitable for use within an FDA-approved MR-guided transcranial focused ultrasound device, within the bore of a 3 Tesla clinical MRI scanner. The array is constructed from 5 × 0.4mm piezoceramic disc elements arranged in pseudorandom fashion on a low profile laser-cut acrylic frame designed to fit between the therapeutic elements of a 230 kHz InSightec ExAblate 4000 transducer. By exploiting thickness and radial resonance modes of the piezo discs the array is capable of both B-mode imaging at 5 MHz for skull localization, as well as passive reception at the second harmonic of the therapy array for mapping of acoustic sources such as emissions from cavitation. The strengths and limitations of the system for passive acoustic imaging during in vivo experiments will be discussed, utilizing robust and conventional time and frequency domain beamforming methods.

  • Optimizing passive cavitation mapping by refined minimum variance-based beamforming method: Performance evaluations in macaque models

    by Tao Sun, Calum Crake, Brian H. Tracey, Costas Arvanitis, Eric Miller, Nathan McDannold

    Microbubble-mediated focused ultrasound (FUS) therapies harness mechanical and/or thermal effects to deliver drugs or ablate tissues. Passive acoustic mapping (PAM) enables the spatio-temporal monitoring of cavitation activity, which is critical for the clinical translation of this technique. Traditional PAM is based on delay-and-sum (DAS) beamforming, a method whose quality tends to deteriorate due to issues including multi-bubble interference, distortion in the wavefront caused by the presence of the skull, unmodeled variability of array elements, etc. To provide for robustness, here we consider the use of minimum variance adaptive beamforming to PAM and demonstrate significant improvement in image quality compared to DAS. The minimum variance distortionless response (MVDR) method was evaluated and further improved by adding diagonal loading and by using subarray covariance estimates. Results demonstrate improvements in both the resolution and image contrast compared to DAS using either traditional or a refined MVDR beamformer. The axial full width at half maximum of the microbubble activity at the focus was reduced to 79.5% and 38.5% of that in DAS image for traditional and refined MVDR beamformers, respectively. Moreover, the refined MVDR method greatly enhanced the robustness while traditional MVDR beamforming induced self-nulling effects. We anticipate that the proposed method will improve our ability to monitor and control FUS-induced cavitation-based therapies.


  • Open Access

    A versatile method for the preparation of particle-loaded microbubbles for multimodality imaging and targeted drug delivery

    by Joshua Owen, Calum Crake, Jeong Yu Lee, Dario Carugo, Estelle Beguin, Alexandre A Khrapitchev, Richard J Browning, Nicola Sibson, Eleanor Stride

    Microbubbles are currently in clinical use as ultrasound contrast agents and under active investigation as mediators of ultrasound therapy. To improve the theranostic potential of microbubbles, nanoparticles can be attached to the bubble shell for imaging, targeting and/or enhancement of acoustic response. Existing methods for fabricating particle-loaded bubbles, however, require the use of polymers, oil layers or chemical reactions for particle incorporation; embed/attach the particles that can reduce echogenicity; impair biocompatibility; and/or involve multiple processing steps. Here, we describe a simple method to embed nanoparticles in a phospholipid-coated microbubble formulation that overcomes these limitations. Magnetic nanoparticles are used to demonstrate the method with a range of different microbubble formulations. The size distribution and yield of microbubbles are shown to be unaffected by the addition of the particles. We further show that the microbubbles can be retained against flow using a permanent magnet, can be visualised by both ultrasound and magnetic resonance imaging (MRI) and can be used to transfect SH-SY5Y cells with fluorescent small interfering RNA under the application of a magnetic field and ultrasound field.


  • Open Access

    Ultrasound‐Enhanced siRNA Delivery Using Magnetic Nanoparticle‐Loaded Chitosan‐Deoxycholic Acid Nanodroplets

    by Jeong Yu Lee, Calum Crake, Boon Teo, Dario Carugo, Marie de Saint Victor, Anjali Seth, Eleanor Stride

    Small interfering RNA (siRNA) has significant therapeutic potential but its clinical translation has been severely inhibited by a lack of effective delivery strategies. Previous work has demonstrated that perfluorocarbon nanodroplets loaded with magnetic nanoparticles can facilitate the intracellular delivery of a conventional chemotherapeutic drug. The aim of this study is to determine whether a similar agent can provide a means of delivering siRNA, enabling efficient transfection without degradation of the molecule. Chitosan‐deoxycholic acid nanoparticles containing perfluoropentane and iron oxide (d 0 = 7.5 ± 0.35 nm) with a mean hydrodynamic diameter of 257.6 ± 10.9 nm are produced. siRNA (AllStars Hs cell death siRNA) is electrostatically bound to the particle surface and delivery to lung cancer cells and breast cancer cells is investigated with and without ultrasound exposure (500 kHz, 1 MPa peak‐to‐peak focal pressure, 40 cycles per burst, 1 kHz pulse repetition frequency, 10 s duration). The results show that siRNA functionality is not impaired by the treatment protocol and that the nanodroplets are able to successfully promote siRNA uptake, leading to significant apoptosis (52.4%) 72 h after ultrasound treatment.


  • Passive Acoustic Mapping with the Angular Spectrum Method

    by Costas D. Arvanitis, Calum Crake, Nathan McDannold, Gregory T. Clement

    In the present proof of principle study, we evaluated the homogenous angular spectrum method for passive acoustic mapping (AS-PAM) of microbubble oscillations using simulated and experimental data. In the simulated data we assessed the ability of AS-PAM to form 3D maps of a single and multiple point sources. Then, in the two dimensional limit, we compared the 2D maps from AS-PAM with alternative frequency and time domain passive acoustic mapping (FD- and TD-PAM) approaches. Finally, we assessed the ability of AS-PAM to visualize microbubble activity in vivo with data obtained during 8 different experiments of FUS-induced blood-brain barrier disruption in 3 nonhuman primates, using a clinical MR-guided FUS system. Our in silico results demonstrate AS-PAM can be used to perform 3D passive acoustic mapping. 2D AS-PAM as compared to FD- PAM and TD-PAM is 10 and 200 times faster respectively and has similar sensitivity, resolution, and localization accuracy, even when the noise was 10-fold higher than the signal. In-vivo, the AS-PAM reconstructions of emissions at frequency bands pertinent to the different types of microbubble oscillations were also found to be more sensitive than TD-PAM. AS-PAM of harmonic-only components predicted safe blood-brain barrier disruption, whereas AS-PAM of broadband emissions correctly identified MR-evident tissue damage. The disparity (3.2 mm) in the location of the cavitation activity between the three methods was within their resolution limits. These data clearly demonstrate that AS-PAM is a sensitive and fast approach for PAM, thus providing a clinically relevant method to guide therapeutic ultrasound procedures.