KNKai Neuhaus

Kai Neuhaus

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kai Neuhaus has a total of 55 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Development of a High-Speed Swept-Source OCT/OCTA/ORG System for Structural and Functional Imaging of the Living Mouse Retina

    by Yuxiang Zhou, Mingliang Zhou, Bo Wang, Xiaoting Yin, Jing Bai, Shuai Wang, Kai Neuhaus, Bernhard Baumann, Yifan Jian, Pengfei Zhang

    The mouse retina serves as a critical model for studying human eye diseases. Optical coherence tomography (OCT) has rapidly advanced as a technique for retinal imaging, with OCT Angiography (OCTA) and Optoretinogram (ORG) emerging as significant functional extensions. High-speed, multifunctional imaging systems markedly enhance the efficiency of experiments by enabling fast and comprehensive data collection from the living mouse retina. However, integrating both high-speed operations and multiple functionalities poses challenges in data acquisition, real-time processing, post-processing, and system complexity. To address these challenges, we developed a high-speed imaging system leveraging a high-speed swept laser source, and a high-speed digitizer for data acquisition. The data acquisition software, developed with C++ and CUDA (Compute Unified Device Architecture), is optimized for rapid and efficient data capture and processing. We reduced system complexity by integrating OCT, OCTA, and ORG protocols and reprogramming post-processing software. Our system, operating at a 400 kHz A-scan rate, supports both structural and functional imaging with a 5.0 μm axial resolution and consistent sensitivity of 53 dB across a 2 mm depth. Utilizing the temporal speckle averaging (TSA) technique, we achieved high contrast-to-noise ratio images, allowing us to delineate retinal structures and blood vessels. For ORG analysis, we developed intensity-based and phase-based methods to evaluate the retina’s light-evoked responses. The intensity-based approach effectively detects photoreceptor elongation and scattering changes, while the phase-based method provides a highly sensitive detection with a temporal resolution of up to 1 ms, revealing subtle changes in the length of the outer segment junction. Overall, this system, to our knowledge, offers the most comprehensive and high-speed imaging capabilities available, delivering detailed structural and functional insights into the living mouse retina.


  • Real-time line-field optical coherence tomography for cellular resolution imaging of biological tissue

    by Kai Neuhaus, Shanjida Khan, Omkar Thaware, Shuibin Ni, Mini Aga, Yali Jia, Travis Redd, Siyu Chen, David Huang, Yifan Jian

    A real-time line-field optical coherence tomography (LF-OCT) system is demonstrated with image acquisition rates of up to 5000 B-frames or 2.5 million A-lines per second for 500 A-lines per B-frame. The system uses a high-speed low-cost camera to achieve continuous data transfer rates required for real-time imaging, allowing the evaluation of future applications in clinical or intraoperative environments. The light source is an 840 nm super-luminescent diode. Leveraging parallel computing with GPU and high speed CoaXPress data transfer interface, we were able to acquire, process, and display OCT data with low latency. The studied system uses anamorphic beam shaping in the detector arm, optimizing the field of view and sensitivity for imaging biological tissue at cellular resolution. The lateral and axial resolution measured in air were 1.7 µm and 6.3 µm, respectively. Experimental results demonstrate real-time inspection of the trabecular meshwork and Schlemm’s canal on ex vivo corneoscleral wedges and real-time imaging of endothelial cells of human subjects in vivo.


  • Open Access

    Nanosensitive optical coherence tomography for detecting structural changes in stem cells

    by Anand Arangath, Niamh Duffy, Sergey Alexandrov, Soorya James, Kai Neuhaus, Mary Murphy, Martin Leahy, Anand A

    Mesenchymal stromal cells (MSCs) are adult stem cells that have been widely investigated for their potential to regenerate damaged and diseased tissues. Multiple pre-clinical studies and clinical trials have demonstrated a therapeutic response following treatment with MSCs for various pathologies, including cardiovascular, neurological and orthopaedic diseases. The ability to functionally track cells following administration in vivo is pivotal to further elucidating the mechanism of action and safety profile of these cells. Effective monitoring of MSCs and MSC-derived microvesicles requires an imaging modality capable of providing both quantitative and qualitative readouts. Nanosensitive optical coherence tomography (nsOCT) is a recently developed technique that detects nanoscale structural changes within samples. In this study, we demonstrate for the first time, the capability of nsOCT to image MSC pellets following labelling with different concentrations of dual plasmonic gold nanostars. We show that the mean spatial period of MSC pellets increases following the labelling with increasing concentrations of nanostars. Additionally, with the help of extra time points and a more comprehensive analysis, we further improved the understanding of the MSC pellet chondrogenesis model. Despite the limited penetration depth (similar to conventional OCT), the nsOCT is highly sensitive in detecting structural alterations at the nanoscale, which may provide crucial functional information about cell therapies and their modes of action.


  • Open Access

    Digitally balanced detection scheme in multiple reference optical coherence tomography

    by Anand Arangath, Kai Neuhaus, Sergey Alexandrov, Martin Leahy, Anand A

    Digitally balanced detection (DBD) has been studied in Fourier domain optical coherence tomography systems to improve sensitivity. We report a technical advancement in a multiple reference optical coherence tomography (MR-OCT) system with the implementation of the DBD technique. We used a free-space, polarization-based balanced detection configuration, which is scalable and suitable for miniaturization. The efficiency of common-mode noise rejection is limited in free-space systems due to the non-uniform illumination of the sensors. We show that recording the signals separately and balancing them in the digital domain improves common mode rejection and signal quality. The application of the DBD scheme for MR-OCT achieves an average sensitivity improvement of 5 ± 0.5 dB over its analogue balanced detection counterpart. We also show that DBD improves the contrast on images of Scotch tapes and mouse eyes.


  • Open Access

    Evaluation of Signal Degradation Due to Birefringence in a Multiple Reference Optical Coherence Tomography System With Polarization-Based Balanced Detection

    by Anand Arangath, Kai Neuhaus, Sergey Alexandrov, Martin Leahy

    Although time-domain optical coherence tomography (TD-OCT) systems are straightforward to realize, the imaging speed, sensitivity, and imaging depth limit their range of applications. Multiple reference optical coherence tomography (MR-OCT) based on TD-OCT increases imaging range by about tenfold while providing sensitivity to image highly scattering biological samples. The multiple path-delays and free-space construction make MR-OCT also interesting for hybrid and compact systems, filling the gap between fibre-based and wafer-level integrated optical systems. We describe an optical configuration using a balanced detection scheme and the resulting signal properties due to the required use of polarizing optical components. We numerically simulate the signal properties using Jones calculus and compare the results with measurements. We discuss the origin of signal degradation due to birefringence of the sample in OCT and show that the quarter-wave plate in the sample arm of the Michelson interferometer can be adjusted to optimize the signal returning from a birefringent sample thereby improving the visibility of structures of interest. The theory discussed will be useful to understand and minimize signal degradation due to birefringence in Time-Domain and Fourier-Domain OCT systems.


  • Open Access

    Simple Characterization Scheme for Optical Coherence Tomography Systems With Application to a Commercial and a Near-Isometric Resolution Fibre-Based System

    by Rajib Dey, Yi Zhou, Kai Neuhaus, Sergey Alexandrov, Andrew Nolan, Ting-Chiao Chang, Martin Leahy

    Optical Coherence Tomography (OCT) is a rapidly growing imaging modality in biomedical optics. OCT can perform high-resolution, cross-sectional imaging of the microstructure of biological tissues by measuring the coherent spectrum from the backscattered light. OCT systems with broad spectral bandwidths are often constructed using free-space optics to avoid dispersion by fibre optic components. This paper presents a fibre-based OCT system at a centre wavelength of 1300 nm with an axial resolution of 3.8 µm in air, surpassing any previously reported values to the best of our knowledge. Despite the challenges in transporting a broadband spectrum using fibre-optics, the system investigation was motivated by the ever-increasing demand for commercialization of high-resolution OCT systems and simplification of construction. We also evaluate and demonstrate the direct measurement method for axial resolution using an air wedge. Imaging of biomedical and other samples is demonstrated using a high numerical aperture sample lens and compared with images from a commercial OCT system. We discuss the effect of the improved structural visibility by achieving image voxels closer to an isometric shape with a high NA sample lens.


  • Open Access

    Contrast agents for photoacoustic imaging: a review of stem cell tracking

    by Soorya James, Kai Neuhaus, Mary Murphy, Martin Leahy

    With the advent of stem cell therapy for spinal cord injuries, stroke, burns, macular degeneration, heart diseases, diabetes, rheumatoid arthritis and osteoarthritis; the need to track the survival, migration pathways, spatial destination and differentiation of transplanted stem cells in a clinical setting has gained increased relevance. Indeed, getting regulatory approval to use these therapies in the clinic depends on biodistribution studies. Although optoacoustic imaging (OAI) or photoacoustic imaging can detect functional information of cell activities in real-time, the selection and application of suitable contrast agents is essential to achieve optimal sensitivity and contrast for sensing at clinically relevant depths and can even provide information about molecular activity. This review explores OAI methodologies in conjunction with the specific application of exogenous contrast agents in comparison to other imaging modalities and describes the properties of exogenous contrast agents for quantitative and qualitative monitoring of stem cells. Specific characteristics such as biocompatibility, the absorption coefficient, and surface functionalization are compared and how the labelling efficiency translates to both short and long-term visualization of mesenchymal stem cells is explored. An overview of novel properties of recently developed optoacoustic contrast agents and their capability to detect disease and recovery progression in clinical settings is provided which includes newly developed exogenous contrast agents to monitor stem cells in real-time for multimodal sensing.


  • Characterization of an amplified piezoelectric actuator for multiple-reference optical coherence tomography

    by Sean O’gOrman, Kai Neuhaus, Sergey Alexandrov, Josh Hogan, Carol Wilson, Paul McNamara, Martin Leahy

    The characterization of an amplified piezoelectric actuator (APA) as a new axial scanning method for multiple-reference optical coherence tomography (MR-OCT) is described. MR-OCT is a compact optical imaging device based on a recirculating reference-arm-scanning optical delay using a partial mirror that can enhance the imaging depth range by more than 10 times the reference mirror’s scanning amplitude. The scanning amplitude of the used APA was varied between 30 μm and 250 μm, depending on the scanning frequency of between 0.8 kHz and 1.2 kHz. A silver-coated miniature mirror was attached to the APA via ultraviolet-cured optical adhesive, and the light source was a super-luminescent diode with 1310 nm center wavelength and 56 nm bandwidth. The sensitivity was measured with and without the partial mirror in the reference delay line as a function of scan speed, frequency, and range, therefore providing results for MR-OCT and TD-OCT modes. It was found that the APA provides more than twice the mechanical scanning range compared to other opto-mechanic actuators, but results indicate degradation of signal-to-noise ratio and sensitivity at larger imaging depths. In conjunction with MR-OCT, the scan range of maximum 200 μm can be enhanced up to 1–1.5 mm by using a reduced amount of orders of reflections, which could be of interest to increase sensitivity in the future.


  • Open Access

    Performance Review of Multiple Reference Versus Time Domain Optical Coherence Tomography

    by Kai Neuhaus, Paul M. McNamara, Sergey Alexandrov, Sean O'GOrman, Josh Hogan, Carol Wilson, Martin J. Leahy

    We present a detailed characterization of noise sources in multiple reference optical coherence tomography (MR-OCT) compared to time-domain OCT (TD-OCT). The noise characteristics were modeled based on the TD-OCT noise model and modified for MR-OCT and confirmed with measurements. The MR-OCT sensitivity characteristics are significantly affected by the reflection from the partial mirror, which also introduces a natural attenuation in the reference arm, partially matching the reflectivity intensity profile of human tissue. At optimal balance between sample and reference arm and using balanced detection, the peak sensitivity was measured to be 95 dB, which is close to simple Fourier-domain systems. The results provide a better understanding of the application range for MR-OCT and higher order effects observed, suggesting a nontrivial noise model for MR-OCT.


  • Open Access

    Real-Time Experimental Measurement of Swept Source VCSEL Properties Relevant to OCT Imaging

    by T. P. Butler, S. Slepneva, P. M. McNamara, K. Neuhaus, D. Goulding, M. Leahy, G. Huyet

    A real-time study of the dynamic properties of a frequency swept vertical cavity surface emitting laser (VCSEL) is presented. Such tunable laser sources have previously been shown to provide long coherence lengths and improved performance in metrology and imaging applications. Single-shot interferometric reconstruction of both the phase and intensity of the swept source allows for experimental measurement of the full complex electric field over multiple sweep periods. Access to the electric field enables direct measurement of laser properties that can be related to the imaging performance of the laser when used in a swept source optical coherence tomography application. Both inter-sweep and intra-sweep characterization is possible, including determination of the instantaneous spectral shape, sweep rate, linewidth, coherence roll-off, and point spread function.