MSMuhammad Abu Bakar Sidik

Muhammad Abu Bakar Sidik

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Muhammad Abu Bakar Sidik has a total of 100 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Turning low-inertia inverters into grid stabilizers: a DRL-based control framework for fragmented power systems

    by Muhammad Abu Bakar Sidik, Muhammad Irfan Jambak, Melia Sari, Noer Fadzri Perdana Dinata, Makbul Anwari Muhammad Ramli, Adios Purnama

  • Open Access

    Simulation-Based Analysis of DRL Exploitation Rate for Voltage and Frequency Stability in a Single-Inverter Microgrid Control System

    by Noer Fadzri Perdana Dinata, Makbul Anwari Muhammad Ramli, Muhammad Irfan Jambak, Prisma Megantoro, Muhammad Abu Bakar Sidik

    This paper discusses the development and performance evaluation of a single-inverter-based microgrid control system using a Deep Reinforcement Learning (DRL) agent trained with the Twin Delayed Deep Deterministic Policy Gradient (TD3) algorithm. The controller is specifically designed to address unplanned transitions during fluctuating load conditions and transitions between grid-tied and islanded modes. An analysis of Final Exploitation Rates (FER) ranging from 5% to 1% was conducted to assess transient responses and steady-state performance. A comparison with a traditional Proportional-Integral-Derivative (PID) controller reveals that while the DRL agent with 2%-FER demonstrates strong performance in managing transient events, the PID controller provides superior stability in steady-state operation. Key performance indicators, including Rise Time, Settling Time, Settling Min/Max, Peak Time, and Mean Absolute Deviation (MAD), were examined. The results show that the DRL agent with 2%-FER effectively limits frequency deviations to ±1% and voltage deviations to within ±2.5% during transitions, whereas agents with FER 3−5% displayed instability with deviations of up to 2% for frequency and 4% for voltage. The PID controller, however, maintained more consistent steady-state performance, with frequency tightly distributed around 49.95−50.05 Hz and voltage near 1 pu. These findings suggest that DRL-based control is better suited for handling unplanned transitions, where proactive adjustment is crucial, while PID control is more effective for steady-state conditions where a passive control approach accommodates system dynamics more naturally.


  • Open Access

    A review on interferometry lightning mapping system and its deployment in Palembang Indonesia

    by Wiwin A. Oktaviani, Muhammad Abu Bakar Sidik, Mohd. Riduan Ahmad, Muhammad Irfan Jambak

    Climate change effects influence the sustainability of wind and photovoltaic energies as renewable sources. Similarly, infrastructure for renewable energy is structurally vulnerable to lightning strikes. Hence, a system for detecting and monitoring lightning activity is necessary to predict and adapt to climate change trends and to enhance the lightning protection system's capability. One such system for observing and locating lightning is very high frequency (VHF) interferometry. Various factors, such as the baseline distance between sensors, the frequencies used, and the quality of the analyzed signal, will influence the system's accuracy. This paper discusses these factors through an extensive literature review. This study aims to identify the factor that most significantly affects the system's accuracy and to determine the technical adjustments required to improve this accuracy. Enhanced precision in the interferometry system will provide a more detailed view of lightning activity, thereby aiding in the climate change prediction that could impact electricity generation from renewable sources. Accurate lightning location detection can also serve as a basis for designing effective lightning protection systems for renewable energy infrastructure.

  • Open Access

    Correlation analysis between lightning flashes and rainfall rate during a flash flood thunderstorm

    by Norbayah Yusop, Mohd Riduan Ahmad, Tan Shea Ching, Shamsul Ammar Shamsul Baharin, Mona Riza Mohd Esa, Muhammad Abu Bakar Sidik

    This paper presents the correlation analysis between lightning flashes and the rainfall rate of a thunderstorm when a flash flood event happened in Melaka on 11 August 2020. Four types of data have been collected from the electric field mill (EFM), fast antenna (FA) system, constant altitude plan position indicator (CAPPI) radar and world wide lightning location network (WWLLN). Two storms have been detected by the EFM occurred between 04:00:00 and 14:00:00. The FA system recorded a total of 33 lightning flashes had detected with the highest number occurrence of flashes which positive narrow bipolar event (+NBE) around 21 flashes, the maximum rainfall rate and reflectivity have been detected by radar during the first storm were 8 mm h-1 and 37 dBZ, respectively (light rain). During the second storm, there was a total of 980 lightning flashes detected by the FA system with the highest number occurrence of flashes around 429 flashes (IC), the highest value of rainfall rate and reflectivity is 50 mm h-1 and 50 dBZ, respectively (heavy rain). Analyses of the lightning and rainfall rate data also show a close link between the occurrence of major thunderstorms systems and flash flooding on a regional scale.


  • Open Access

    Efficacy of Dissolved Ozone against Staphylococcus aureus and Bacillus cereus Microorganism

    by Syarifa Fitria, Muhammad Abubakar Sidik, Zolkafle Buntat, Zainuddin Nawawi, Muhammad Irfan Jambak, Nur Nabilah Kamarudin, Fatin Nabilah Musa

    Ozone is a robust antimicrobial agent with numerous potential applications in the industry. Ozone, in either gaseous or aqueous phases is effective against the majority of microorganisms. Relatively low concentrations of ozone and short contact time are sufficient to inactivate bacteria and...


  • Effect of Surfactant on Breakdown Strength Performance of Transformer Oil-Based Nanofluids

    by Muhammad Faris Baharuddin, Izzah Hazirah Zakaria, Mohd Hafizi Ahmad, Aulia, Zainuddin Nawawi, Muhammad Abu Bakar Sidik, Muhammad Irfan Jambak


  • Effects of Cold Plasma Treatment on the Growth Rate of Corn and Eggplant Plants

    by Muhammad Abu Bakar Sidik, Zolkafle Buntat, Zainuddin Nawawi, Muhammad Irfan Jambak, Yahya Buntat, Fatin Nabilah Musa

    This paper investigates the effect of cold plasma on the germination, growth, and yield of corn plant. The effect of plasma plume was applied to the corn seeds to kill the bacteria on the outer surface of the seeds to investigate the effects of cold plasma towards the germination and growth rate of the seeds. The time of treatment was varied from 3, 5 and 10 minutes to identify the optimum treatment time. The result showed that the seeds that treated with 3 minutes plasma treatment germinates faster and show excellent growth rate compared to the untreated seed. This revealed that cold plasma treatment as an alternative method to promote seed germination and enhance seed growth of the corn plant.


  • Open Access

    Structural and Optical properties of Multiwalled Carbon Nanotubes Modified by DBD Plasma at Atmospheric Pressure

    by Norain Sahari, Zolkafle Buntat, Zulkifli Azman, Zainuddin Nawawi, Muhammad Abu Bakar Sidik, Muhammad Irfan Jambak

    Structure, chemical, and physical properties of Multiwalled Carbon Nanotubes (MWCNTs) after modification by dielectric barrier discharge (DBD) at atmospheric pressure is investigated using Transmission Electron Microscopy (TEM), Raman and Uv-vis-NIR spectroscopy. Effects of plasma treatment time on MWCNTs are analyzed. TEM result shows that during the short period of plasma treatment time of 5 minutes, the tube surface experienced a few damages. With increase in plasma treatment time, the tube surface is damaged to a certain extent. Intensity ratio, ID/IG through Raman analysis shows a good agreement with TEM. The values of ID/IG of the modified MWCNTs are larger than those of pristine MWCNTs. An increase of ID/IG indicates that considerable defects are produced on the surfaces of MWCNTs. The treated MWCNTs has energy band gap compared to zero band gap of untreated MWCNTs. It is believed that the defect site of MWCNTs can modify the electronics properties of MWCNTs from being metallic to semiconducting structure, which is applicable for almost all electronics device applications.

  • The Temperature Effect to the Concrete due to the Single Strike of High Electric Current

    by Mustaqqim Abdul Rahim, Abdul Naser Abdul Ghani, Muhammad Arkam Che Munaaim, Muhammad Abu Bakar Sidik, Zulhelmi Zulkeflee

    The protection against lightning had been increasingly used in the building to protect the building from the direct lightning impact. One of the methods is to embed the lightning protection cable in the concrete structure. The objective of this research is to investigate any changes of temperature during the lightning strike, which the lightning strike were stimulated by high electric current equipment. The high electric current were provided by high current equipment model Haefely P90.1 and flowed into the concrete cube. There are two method used in this research, by using Thermal Imager Camera Model FLUKE Ti20 to monitor the surface temperature and fiber thermocouple with Data logger model DATATAKER T80 to monitor the temperature in the concrete cube. As the result there are no drastically changes in temperature in both methods. The changes are very small and can be negliable. This is due to the duration of the high electric current strike is too short and not caused any changes in the temperature.


  • DEVELOPMENT OF A REMOTE ACCESSIBLE ELECTRICAL POWER MEASURING SYSTEM FOR DOMESTIC CUSTOMER

    by H. M. Yusoff, Y. Z. Arief, Z. A. Noorden, Z. Adzis, N. Bashir, N. A. Muhamad, M. H. Ahmad, M. A. B. Sidik

    Tenaga Nasional Berhad (TNB) is a power utility company in Malaysia that performs three main thrust in the electricity sector. One of which is the distribution sector. The distribution sector involves other activity associated with the customer. Many initiatives have been introduced by TNB to satisfy all its customers. This research introduces a method of reading electric meter without sending meter readers to the premises of the customers. This method was introduced to large power customers (LPC) to ensure total consumption recorded is accurate. Since 2005, remote metering reading project has been using global packet radio service (GPRS) technology as a medium of communication. However, GPRS communication system at that time has not been widely used. Use of electronic meters is introduced to LPC because this meter can provide current information about electricity consumption. A total of 45,000 users of LPC involved in the installation of electronic meters and global system for mobile communication (GSM) modem in which this system can determine the amount of electric current consumption compared to manual meter reading is applied. In this project, the XBee radio module is used to send data to a GSM modem. From GSM modem, users can get the total electricity consumption through the SMS (short message service) system in their mobile phones. This project aim is to facilitate the customers so that they do not have to waste time going to the Kedai Tenaga (electricity payment counter) to find out the amount of energy consumed during the period. TNB can also collect the metering details without sending personnel to produce monthly bills.