Akio Yamamoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Akio Yamamoto has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
Akira Ishikawa
Graduate School of Health Sciences, Kobe University, Hyogo, Japan
5 shared publicationsYusuke Bessho
Bando Chemical Industries, Ltd. Kobe Japan
5 shared publicationsHiroyuki Nakamoto
Kobe University Graduate School of System Informatics Kobe Japan
4 shared publicationsKaku Sawada
Keiwakai Nishioka Hospital, 4-1-52, Nishioka-4-jou, Toyohira-ku, Sapporo, 062-0034, Japan
3 shared publications- Fumiyuki Ozawa
International Research Center for Elements Science (IRCELS), Institute for Chemical Research, Kyoto University, Uji, Kyoto 611-0011, Japan
2 shared publications Hideki Sakai
Kobe City Hospital Organization, Kobe City Medical Center West Hospital, 2-4, Ichibancho, Nagata-ku, Kobe, 653-0013, Japan
2 shared publications
Latest Publications
- 14 April 2026
- Published by Wiley in Japan Journal of Nursing Science
- Vol. 23 (2) , e70051
Effects of continuous nurse home visits on the parenting practices of pregnant females and mothers with infants or preschool children: A systematic review and meta‐analysis
Aim: This study aimed to examine whether home visits by nurses improve the parenting practices of pregnant and postpartum females through a systematic review and meta‐analysis. Methods: We searched PubMed, MEDLINE, Cochrane Library, and Ichushi for randomized controlled trials of regular home visits by nurses or midwives during pregnancy or before the child entered school, published up to March 2023. The primary outcomes were: (1) positive parenting behaviors; (2) negative parenting behaviors; (3) parental confidence; (4) child–parent relationships; and (5) parent–child closeness. We performed random‐effects meta‐analyses and applied risk of bias assessment and GRADE (Grading of Recommendations, Assessment, Development, and Evaluation)‐based evaluation frameworks. The study has been registered in PROSPERO (CRD 42024527084). Results: In total, 1879 articles were screened and eight were included in analyses. The eight articles involved five home visit projects targeting high‐risk females and one focused on the general population. Moderate certainty of evidence indicated that nurse home visits increased positive parenting behavior (SMD = 0.16, 95% CI [0.07; 0.26]), decreased negative parenting behavior (SMD = −0.11, 95% CI [−0.21; −0.01]), and had no significant effect on parental confidence (SMD = 0.26, 95% CI [−0.12; 0.64]). No significant intervention effects were observed for child–parent relationships or parent–child closeness, with weak certainty of evidence based on a single article. Conclusions: Home visits by nurses and midwives increased positive parenting behaviors and decreased negative behaviors. These findings suggest that regular home‐visit interventions by nurses are effective in improving the child‐rearing behaviors of pregnant and postpartum females.
- 14 April 2026
- Published by Wiley in Japan Journal of Nursing Science
- Vol. 23 (2) , e70051
Effects of continuous nurse home visits on the parenting practices of pregnant females and mothers with infants or preschool children: A systematic review and meta‐analysis
Aim: This study aimed to examine whether home visits by nurses improve the parenting practices of pregnant and postpartum females through a systematic review and meta‐analysis. Methods: We searched PubMed, MEDLINE, Cochrane Library, and Ichushi for randomized controlled trials of regular home visits by nurses or midwives during pregnancy or before the child entered school, published up to March 2023. The primary outcomes were: (1) positive parenting behaviors; (2) negative parenting behaviors; (3) parental confidence; (4) child–parent relationships; and (5) parent–child closeness. We performed random‐effects meta‐analyses and applied risk of bias assessment and GRADE (Grading of Recommendations, Assessment, Development, and Evaluation)‐based evaluation frameworks. The study has been registered in PROSPERO (CRD 42024527084). Results: In total, 1879 articles were screened and eight were included in analyses. The eight articles involved five home visit projects targeting high‐risk females and one focused on the general population. Moderate certainty of evidence indicated that nurse home visits increased positive parenting behavior (SMD = 0.16, 95% CI [0.07; 0.26]), decreased negative parenting behavior (SMD = −0.11, 95% CI [−0.21; −0.01]), and had no significant effect on parental confidence (SMD = 0.26, 95% CI [−0.12; 0.64]). No significant intervention effects were observed for child–parent relationships or parent–child closeness, with weak certainty of evidence based on a single article. Conclusions: Home visits by nurses and midwives increased positive parenting behaviors and decreased negative behaviors. These findings suggest that regular home‐visit interventions by nurses are effective in improving the child‐rearing behaviors of pregnant and postpartum females.
- 2 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 9 (10) , 1-4
I:E Ratio Estimation Using a Patch-Type Multimodal Sensor for Pulmonary Function Screening of COPD
Chronic obstructive pulmonary disease (COPD) is the third leading cause of death in the world, and doctors expect the number of patients to increase by 23% in 2050. Patients experience dyspnea during physical exertion due to compromised pulmonary gas exchange capacity. Deterioration of pulmonary function is expected to appear in the Inspiratory to Expiratory ratio (I:E ratio). However, the I:E ratio is often unmonitored even in hospitals. The I:E ratio is not yet a standard index for health monitoring; therefore, it remains untouched by most studies. Therefore, we aim to estimate the I:E ratio from the proposed patch-type multimodal sensor for pulmonary function screening of prediagnosed COPD patients. We conducted experiments with three types of I:E ratios on 14 healthy participants. The first objective was a trend analysis of photoplethysmography (PPG) and three-axis acceleration respiratory signals acquired from the proposed multimodal sensor. From the results, the best results of the four signals differed depending on signal amplitude, baseline wander, inconsistency, and vibration. Hence, by formulating a signal quality evaluation step, we proposed a signal selection method to systematically determine the best of the four signals for I:E ratio estimation.
- 2 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 9 (10) , 1-4
I:E Ratio Estimation Using a Patch-Type Multimodal Sensor for Pulmonary Function Screening of COPD
Chronic obstructive pulmonary disease (COPD) is the third leading cause of death in the world, and doctors expect the number of patients to increase by 23% in 2050. Patients experience dyspnea during physical exertion due to compromised pulmonary gas exchange capacity. Deterioration of pulmonary function is expected to appear in the Inspiratory to Expiratory ratio (I:E ratio). However, the I:E ratio is often unmonitored even in hospitals. The I:E ratio is not yet a standard index for health monitoring; therefore, it remains untouched by most studies. Therefore, we aim to estimate the I:E ratio from the proposed patch-type multimodal sensor for pulmonary function screening of prediagnosed COPD patients. We conducted experiments with three types of I:E ratios on 14 healthy participants. The first objective was a trend analysis of photoplethysmography (PPG) and three-axis acceleration respiratory signals acquired from the proposed multimodal sensor. From the results, the best results of the four signals differed depending on signal amplitude, baseline wander, inconsistency, and vibration. Hence, by formulating a signal quality evaluation step, we proposed a signal selection method to systematically determine the best of the four signals for I:E ratio estimation.
- 1 December 2021
- Published by Elsevier in Respiratory Medicine
- Vol. 190, 106675
Validity of a novel respiratory rate monitor comprising stretchable strain sensors during a 6-min walking test in patients with chronic pulmonary obstructive disease
- 1 December 2021
- Published by Elsevier in Respiratory Medicine
- Vol. 190, 106675
Validity of a novel respiratory rate monitor comprising stretchable strain sensors during a 6-min walking test in patients with chronic pulmonary obstructive disease
- Open Access
- 1 June 2021
- Published by Taylor & Francis in International Journal of Chronic Obstructive Pulmonary Disease
- Vol. ume 16, 1863-1871
Reliability and Validity of the Japanese Version of the Barthel Index Dyspnea Among Patients with Respiratory Diseases
Purpose: Japan has only a few respiratory disease-specific activity of daily living scales that are accepted outside of Japan, and they are not widely used. The Barthel Index dyspnea (BI-d), an improved version of the Barthel Index (BI), may be popular in Japan. The purpose of this study was to develop the Japanese version of BI-d (J-BI-d) and investigate its reliability and validity. Patients and Methods: The J-BI-d was developed using the basic guidelines for scale translation. The study included patients with chronic respiratory disease, receiving outpatient care at two centers between January 2019 and February 2020. Scores on the J-BI-d, modified Medical Research Council scale (mMRC scale), BI, respiratory function tests, and 6-minute walk distance (6MWD) test were measured. To verify the test–retest reliability, the J-BI-d was re-administered, and the intraclass correlation coefficient (ICC) was obtained. Internal consistency was verified by Cronbach’s alpha reliability coefficient, and criterion-related validity was verified through a correlation analysis of the J-BI-d with mMRC scale and 6MWD test. Divergent validity was verified through correlation analysis between the J-BI-d and BI. Results: Data for 57 participants (mean age 74.4 ± 8.3 years) were analyzed, and reliability testing was performed with 42 of them. The mean time to retest was 8.1 ± 3.0 days, and the ICC (2, 1) was 0.76 (95% CI: 0.62– 0.85), indicating high reliability. Cronbach’s alpha reliability coefficient was 0.81, indicating high internal consistency. Correlation coefficients of the J-BI-d with 6MWD test (r = − 0.46, p < 0.01) and mMRC scale (ρ = 0.76, p < 0.01) indicated high criterion-related validity. The J-BI-d and BI had a weak negative correlation (r = − 0.29, p < 0.05), indicating high divergent validity. Conclusion: The results of this study demonstrate high reliability and appropriate validity of the J-BI-d in patients with chronic respiratory disease.
- 1 June 2021
- Published by Taylor & Francis in International Journal of Chronic Obstructive Pulmonary Disease
- Vol. ume 16, 1863-1871
Open AccessReliability and Validity of the Japanese Version of the Barthel Index Dyspnea Among Patients with Respiratory Diseases
Purpose: Japan has only a few respiratory disease-specific activity of daily living scales that are accepted outside of Japan, and they are not widely used. The Barthel Index dyspnea (BI-d), an improved version of the Barthel Index (BI), may be popular in Japan. The purpose of this study was to develop the Japanese version of BI-d (J-BI-d) and investigate its reliability and validity. Patients and Methods: The J-BI-d was developed using the basic guidelines for scale translation. The study included patients with chronic respiratory disease, receiving outpatient care at two centers between January 2019 and February 2020. Scores on the J-BI-d, modified Medical Research Council scale (mMRC scale), BI, respiratory function tests, and 6-minute walk distance (6MWD) test were measured. To verify the test–retest reliability, the J-BI-d was re-administered, and the intraclass correlation coefficient (ICC) was obtained. Internal consistency was verified by Cronbach’s alpha reliability coefficient, and criterion-related validity was verified through a correlation analysis of the J-BI-d with mMRC scale and 6MWD test. Divergent validity was verified through correlation analysis between the J-BI-d and BI. Results: Data for 57 participants (mean age 74.4 ± 8.3 years) were analyzed, and reliability testing was performed with 42 of them. The mean time to retest was 8.1 ± 3.0 days, and the ICC (2, 1) was 0.76 (95% CI: 0.62– 0.85), indicating high reliability. Cronbach’s alpha reliability coefficient was 0.81, indicating high internal consistency. Correlation coefficients of the J-BI-d with 6MWD test (r = − 0.46, p < 0.01) and mMRC scale (ρ = 0.76, p < 0.01) indicated high criterion-related validity. The J-BI-d and BI had a weak negative correlation (r = − 0.29, p < 0.05), indicating high divergent validity. Conclusion: The results of this study demonstrate high reliability and appropriate validity of the J-BI-d in patients with chronic respiratory disease.
- 1 December 2020
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 47 (12) , 1489-1495
Measurement of laryngeal elevation time using a flexible surface stretch sensor
Background Dysphagia is a growing health problem in aging societies. An observational cohort study targeting community-dwelling populations revealed that 16% of elderly subjects present with dysphagia. There is a need in elderly communities for systematic dysphagia assessment. Objective This study aimed to verify whether laryngeal elevation in the pharyngeal phase could be measured from the body surface using thin and flexible stretch sensors. Methods Thirty-two elderly subjects (17 males, 15 females; mean age +/- SD: 89.2 +/- 6.2 years) with suspected dysphagia underwent a swallowing contrast examination in which seven stretch sensors were attached to the front of the neck. The elongation of the sensors was measured and compared to the laryngeal elevation time values obtained using videofluorography. The sensor signal detected the laryngeal elevation start time, conclusion of the descent of the larynx, and the laryngeal elevation time. The respective laryngeal elevation times obtained using videofluorography and using the sensor were compared using the Bland-Altman method. Results The laryngeal elevation time was 1.34 +/- 0.46 s with the stretch sensor and 1.49 +/- 0.56 s with videofluorography. There was a significant positive correlation between the duration obtained by both methods (r = .69,P < .0001). A negative additional significant bias of -0.15 s (95% confidence interval -0.30 to -0.03,P = .046) was noted in the laryngeal elevation time from the videofluorography measurement. Conclusion Laryngeal elevation time can be measured non-invasively from the neck surface using stretch sensors.
- 1 December 2020
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 47 (12) , 1489-1495
Measurement of laryngeal elevation time using a flexible surface stretch sensor
Background Dysphagia is a growing health problem in aging societies. An observational cohort study targeting community-dwelling populations revealed that 16% of elderly subjects present with dysphagia. There is a need in elderly communities for systematic dysphagia assessment. Objective This study aimed to verify whether laryngeal elevation in the pharyngeal phase could be measured from the body surface using thin and flexible stretch sensors. Methods Thirty-two elderly subjects (17 males, 15 females; mean age +/- SD: 89.2 +/- 6.2 years) with suspected dysphagia underwent a swallowing contrast examination in which seven stretch sensors were attached to the front of the neck. The elongation of the sensors was measured and compared to the laryngeal elevation time values obtained using videofluorography. The sensor signal detected the laryngeal elevation start time, conclusion of the descent of the larynx, and the laryngeal elevation time. The respective laryngeal elevation times obtained using videofluorography and using the sensor were compared using the Bland-Altman method. Results The laryngeal elevation time was 1.34 +/- 0.46 s with the stretch sensor and 1.49 +/- 0.56 s with videofluorography. There was a significant positive correlation between the duration obtained by both methods (r = .69,P < .0001). A negative additional significant bias of -0.15 s (95% confidence interval -0.30 to -0.03,P = .046) was noted in the laryngeal elevation time from the videofluorography measurement. Conclusion Laryngeal elevation time can be measured non-invasively from the neck surface using stretch sensors.
- 28 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (13) , 14352-14359
Wearable Band-Shaped Device and Detection Algorithm for Laryngeal Elevation in Mendelsohn Maneuver
Aspiration pneumonia is a serious condition in the elderly. To strengthen the muscles required for swallowing, patients can train using the Mendelsohn maneuver, wherein they maintain their larynx at the top of the laryngeal elevation during swallowing. This study describes a wearable device to detect the onset and offset times of the laryngeal elevation for a biofeedback system to support this training. The biofeedback system consists of a band-shaped device with stretchable strain sensors. The strain sensors measure the change of circumferential length of the neck. An algorithm detects the onset and offset times of the laryngeal elevation based on the absolute first-order difference of the measured data and distance between the measured data and template data by pattern matching. The algorithm detected the onset and offset times of 53 out of 54 data sets from elderly participants. Cluster analysis separated the data into two groups. For both groups, the mean absolute error of the interval time was within 1 s when compared with the time recorded by a speech-language-hearing therapist. We believe that this biofeedback system for the Mendelsohn maneuver tolerates the 1 s delay. The wearable device is soft, lightweight, and easy for a patient to use alone. The efficacy of the device for the strengthening of muscles must be verified in a clinical study.
- 28 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (13) , 14352-14359
Wearable Band-Shaped Device and Detection Algorithm for Laryngeal Elevation in Mendelsohn Maneuver
Aspiration pneumonia is a serious condition in the elderly. To strengthen the muscles required for swallowing, patients can train using the Mendelsohn maneuver, wherein they maintain their larynx at the top of the laryngeal elevation during swallowing. This study describes a wearable device to detect the onset and offset times of the laryngeal elevation for a biofeedback system to support this training. The biofeedback system consists of a band-shaped device with stretchable strain sensors. The strain sensors measure the change of circumferential length of the neck. An algorithm detects the onset and offset times of the laryngeal elevation based on the absolute first-order difference of the measured data and distance between the measured data and template data by pattern matching. The algorithm detected the onset and offset times of 53 out of 54 data sets from elderly participants. Cluster analysis separated the data into two groups. For both groups, the mean absolute error of the interval time was within 1 s when compared with the time recorded by a speech-language-hearing therapist. We believe that this biofeedback system for the Mendelsohn maneuver tolerates the 1 s delay. The wearable device is soft, lightweight, and easy for a patient to use alone. The efficacy of the device for the strengthening of muscles must be verified in a clinical study.
- 17 November 2019
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 57 (12) , 2741-2756
Monitoring respiratory rates with a wearable system using a stretchable strain sensor during moderate exercise
Respiratory rate, a sensitive indicator of respiratory status, is rarely measured during the field walking test. Our objective was to develop and validate a non-invasive, wearable monitoring system using stretchable strain sensors and an accompanying algorithm capable of providing real-time measurements of respiration during exercise. Twenty-four healthy volunteers wore stretchable sensors during a walking test protocol that included standing, sitting, walking, and walking with a stick. Sensors were placed on the ribcage and abdomen. The Bland-Altman method was used to assess the accuracy and precision of breath counts; total respiration time and inspiration time ratio were determined by custom algorithms and compared with measurements obtained with the standard flow sensor. The output signal from the stretchable sensor was highly synchronized with flow signals. The limits of agreement were within 3 breaths/min throughout the test protocol. Differences between sensors for total respiration time and inspiration time ratio were less than 14% and 26%, respectively. The agreement was maintained regardless of respiratory rate or volume. The wearable respiratory monitoring system yielded accurate and precise breath counts and total duration of respiratory cycle during moderate exercise in healthy young individuals, suggesting that it might be useful in clinical practice. Graphical abstract
- 17 November 2019
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 57 (12) , 2741-2756
Monitoring respiratory rates with a wearable system using a stretchable strain sensor during moderate exercise
Respiratory rate, a sensitive indicator of respiratory status, is rarely measured during the field walking test. Our objective was to develop and validate a non-invasive, wearable monitoring system using stretchable strain sensors and an accompanying algorithm capable of providing real-time measurements of respiration during exercise. Twenty-four healthy volunteers wore stretchable sensors during a walking test protocol that included standing, sitting, walking, and walking with a stick. Sensors were placed on the ribcage and abdomen. The Bland-Altman method was used to assess the accuracy and precision of breath counts; total respiration time and inspiration time ratio were determined by custom algorithms and compared with measurements obtained with the standard flow sensor. The output signal from the stretchable sensor was highly synchronized with flow signals. The limits of agreement were within 3 breaths/min throughout the test protocol. Differences between sensors for total respiration time and inspiration time ratio were less than 14% and 26%, respectively. The agreement was maintained regardless of respiratory rate or volume. The wearable respiratory monitoring system yielded accurate and precise breath counts and total duration of respiratory cycle during moderate exercise in healthy young individuals, suggesting that it might be useful in clinical practice. Graphical abstract
- 7 February 2019
- Published by Taylor & Francis in Disability and Rehabilitation: Assistive Technology
- Vol. 15 (1) , 54-59
Application of a wearable switch to perform a mouse left click for a child with mix type of cerebral palsy: a single case study
Purpose: Children with cerebral palsy may face difficulties using handheld pointing devices, due to involuntary muscle movements. This study aimed at describing the idea of the new wearable sensor switch and assessing its feasibility as an access solution in a case of mixed-type cerebral palsy. Methods: The study participant was a 17-year-old male with mixed-type cerebral palsy characterized by chorea-athetotic movements and bilateral spasticity with gross motor function classification system level V. He exhibited sudden and irregular involuntary upper limb movements when sitting. Because spastic finger movements limited his ability to use a handheld mouse, he used a trackball near his neck as a pointing device (previous input method). The wearable switch system using a stretchable strain sensor was introduced; the sensor was attached to a groove worn on the dorsal regions of the right hand crossing the proximal interphalangeal and metacarpophalangeal joints of the middle finger (new input method). The switch turned on when the subject flexed his middle finger. Results: The user successfully turned the switch on and typed almost the same numbers of characters per trial compared with the previous input method. The speed of his head movements during typing reduced (p < .01), and his sitting posture was nearly upright during computer operation (p < .01). No involuntary movement, requiring physical assistance, was observed when using the wearable switch. Conclusion: The new switch system can be a new option for people with difficulty using standard handheld input devices due to paralysis and involuntary muscle movements.
- 7 February 2019
- Published by Taylor & Francis in Disability and Rehabilitation: Assistive Technology
- Vol. 15 (1) , 54-59
Application of a wearable switch to perform a mouse left click for a child with mix type of cerebral palsy: a single case study
Purpose: Children with cerebral palsy may face difficulties using handheld pointing devices, due to involuntary muscle movements. This study aimed at describing the idea of the new wearable sensor switch and assessing its feasibility as an access solution in a case of mixed-type cerebral palsy. Methods: The study participant was a 17-year-old male with mixed-type cerebral palsy characterized by chorea-athetotic movements and bilateral spasticity with gross motor function classification system level V. He exhibited sudden and irregular involuntary upper limb movements when sitting. Because spastic finger movements limited his ability to use a handheld mouse, he used a trackball near his neck as a pointing device (previous input method). The wearable switch system using a stretchable strain sensor was introduced; the sensor was attached to a groove worn on the dorsal regions of the right hand crossing the proximal interphalangeal and metacarpophalangeal joints of the middle finger (new input method). The switch turned on when the subject flexed his middle finger. Results: The user successfully turned the switch on and typed almost the same numbers of characters per trial compared with the previous input method. The speed of his head movements during typing reduced (p < .01), and his sitting posture was nearly upright during computer operation (p < .01). No involuntary movement, requiring physical assistance, was observed when using the wearable switch. Conclusion: The new switch system can be a new option for people with difficulty using standard handheld input devices due to paralysis and involuntary muscle movements.
- Open Access
- 18 April 2018
- Published by Japanese Association of Rehabilitation Medicine in The Japanese Journal of Rehabilitation Medicine
- Vol. 55 (4) , 348-357
Development of a Measurement Device Using a Sheet Stretch Sensor for Chest Wall Motion
目的:呼吸リハビリテーションのための簡便で非侵襲的に胸郭運動を計測するストレッチセンサ(STR)が開発された.本研究の目的は,STRによる胸郭運動計測の妥当性を検討することである. 方法:健常成人男性12名が立位姿勢で3つのセンサ〔STR,インダクタンス式呼吸プレチスモグラフィー(RIP),スパイロメーター(FLOW)〕を装着し,4つの呼吸様式(自然呼吸:120秒,深呼吸:60秒,頻呼吸:60秒,無呼吸:60秒)での胸郭運動を計測した.STRはバンドとして胸部と腹部に装着した.各センサの胸郭運動計測について分析した. 結果:STRの出力はFLOWおよびRIPと有意な相関を示した(r=0.50~1.00, p<0.05).STRから得た呼吸回数はFLOWから得た実測値と差を認めなかった(p>0.05).STR出力は呼吸様式によって有意に変化していた(無呼吸<頻呼吸<自然呼吸<深呼吸,p<0.05). 結論:STRは健常若年健常者におけるさまざまな呼吸条件において胸郭運動を計測することができる.
- 18 April 2018
- Published by Japanese Association of Rehabilitation Medicine in The Japanese Journal of Rehabilitation Medicine
- Vol. 55 (4) , 348-357
Open AccessDevelopment of a Measurement Device Using a Sheet Stretch Sensor for Chest Wall Motion
目的:呼吸リハビリテーションのための簡便で非侵襲的に胸郭運動を計測するストレッチセンサ(STR)が開発された.本研究の目的は,STRによる胸郭運動計測の妥当性を検討することである. 方法:健常成人男性12名が立位姿勢で3つのセンサ〔STR,インダクタンス式呼吸プレチスモグラフィー(RIP),スパイロメーター(FLOW)〕を装着し,4つの呼吸様式(自然呼吸:120秒,深呼吸:60秒,頻呼吸:60秒,無呼吸:60秒)での胸郭運動を計測した.STRはバンドとして胸部と腹部に装着した.各センサの胸郭運動計測について分析した. 結果:STRの出力はFLOWおよびRIPと有意な相関を示した(r=0.50~1.00, p<0.05).STRから得た呼吸回数はFLOWから得た実測値と差を認めなかった(p>0.05).STR出力は呼吸様式によって有意に変化していた(無呼吸<頻呼吸<自然呼吸<深呼吸,p<0.05). 結論:STRは健常若年健常者におけるさまざまな呼吸条件において胸郭運動を計測することができる.
- Open Access
- 11 October 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (10) , e0183651
Method for measuring tri-axial lumbar motion angles using wearable sheet stretch sensors
Body movements, such as trunk flexion and rotation, are risk factors for low back pain in occupational settings, especially in healthcare workers. Wearable motion capture systems are potentially useful to monitor lower back movement in healthcare workers to help avoid the risk factors. In this study, we propose a novel system using sheet stretch sensors and investigate the system validity for estimating lower back movement. Six volunteers (female:male = 1:1, mean age: 24.8 ± 4.0 years, height 166.7 ± 5.6 cm, weight 56.3 ± 7.6 kg) participated in test protocols that involved executing seven types of movements. The movements were three uniaxial trunk movements (i.e., trunk flexion-extension, trunk side-bending, and trunk rotation) and four multiaxial trunk movements (i.e., flexion + rotation, flexion + side-bending, side-bending + rotation, and moving around the cranial–caudal axis). Each trial lasted for approximately 30 s. Four stretch sensors were attached to each participant’s lower back. The lumbar motion angles were estimated using simple linear regression analysis based on the stretch sensor outputs and compared with those obtained by the optical motion capture system. The estimated lumbar motion angles showed a good correlation with the actual angles, with correlation values of r = 0.68 (SD = 0.35), r = 0.60 (SD = 0.19), and r = 0.72 (SD = 0.18) for the flexion-extension, side bending, and rotation movements, respectively (all P < 0.05). The estimation errors in all three directions were less than 3°. The stretch sensors mounted on the back provided reasonable estimates of the lumbar motion angles. The novel motion capture system provided three directional angles without capture space limits. The wearable system possessed great potential to monitor the lower back movement in healthcare workers and helping prevent low back pain.
- 11 October 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (10) , e0183651
Open AccessMethod for measuring tri-axial lumbar motion angles using wearable sheet stretch sensors
Body movements, such as trunk flexion and rotation, are risk factors for low back pain in occupational settings, especially in healthcare workers. Wearable motion capture systems are potentially useful to monitor lower back movement in healthcare workers to help avoid the risk factors. In this study, we propose a novel system using sheet stretch sensors and investigate the system validity for estimating lower back movement. Six volunteers (female:male = 1:1, mean age: 24.8 ± 4.0 years, height 166.7 ± 5.6 cm, weight 56.3 ± 7.6 kg) participated in test protocols that involved executing seven types of movements. The movements were three uniaxial trunk movements (i.e., trunk flexion-extension, trunk side-bending, and trunk rotation) and four multiaxial trunk movements (i.e., flexion + rotation, flexion + side-bending, side-bending + rotation, and moving around the cranial–caudal axis). Each trial lasted for approximately 30 s. Four stretch sensors were attached to each participant’s lower back. The lumbar motion angles were estimated using simple linear regression analysis based on the stretch sensor outputs and compared with those obtained by the optical motion capture system. The estimated lumbar motion angles showed a good correlation with the actual angles, with correlation values of r = 0.68 (SD = 0.35), r = 0.60 (SD = 0.19), and r = 0.72 (SD = 0.18) for the flexion-extension, side bending, and rotation movements, respectively (all P < 0.05). The estimation errors in all three directions were less than 3°. The stretch sensors mounted on the back provided reasonable estimates of the lumbar motion angles. The novel motion capture system provided three directional angles without capture space limits. The wearable system possessed great potential to monitor the lower back movement in healthcare workers and helping prevent low back pain.