Ana Megia-Macias
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ana Megia-Macias has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Osvaldo Daniel Cortázar
Electrical Engineering Department, Colorado State University, Fort Collins, Colorado 80523
10 shared publications A Vizcaíno-De-Julián
2 shared publicationsA. Vizcaíno-De-Julián
E.S.S. Bilbao, Edificio Cosimet, Landabarri 2, 48940-Leioa, Vizcaya, Spain
2 shared publications- Elena Barrios-Diaz
Institute for Energy Research (INEI), University of Castilla-La Mancha 2 , c/Moledores s/n, 13071 Ciudad Real, Spain
2 shared publications Alvaro Vizcaino-De-Julian
European Spallation Source Bilbao Consortium, Edificio Cosimet, Leioa, Spain
1 shared publicationB. Lefort
CERN, European Organization for Nuclear Research, Switzerland
1 shared publication
Latest Publications
- Open Access
- 28 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (5) , 680-688
Demonstration of the High Efficiency of an Air Plasma Jet Combining Electric Field and RONS in the Treatment of Chronic Wounds
A Cold Atmospheric Air Plasma Jet (CAAPJ) for the treatment of skin injuries in medicine and veterinary medicine is presented with experimental evidence that point to the electric field inside the plasmas jet could be a determinant therapeutic mechanism. The device is characterized by producing a cold atmospheric air plasma jet compatible with living tissues at a low heat transfer rate with a temperature on the skin surface below 40 . It has a practical design to be used by physicians and veterinaries during daily practice, with a special focus on the treatment of skin injuries and unhealed ulcers. Plasma diagnostics, including currents-voltage signals, UV-VIS spectroscopy, IR images of the skin, and electric field measurements in the air cold plasma jet are presented. The last is made for the first time in this type of plasma, and them can justify the induction of local electric currents on the wound surface to accelerate healing by highlighting the possible synergy with Reactive Oxygen and Nitrogen Species (RONS) as a decontaminant agent for bacteria (including resistant), fungi and viruses without damaging healthy tissue. A remarkable clinical case study example is reported.
- 28 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (5) , 680-688
Open AccessDemonstration of the High Efficiency of an Air Plasma Jet Combining Electric Field and RONS in the Treatment of Chronic Wounds
A Cold Atmospheric Air Plasma Jet (CAAPJ) for the treatment of skin injuries in medicine and veterinary medicine is presented with experimental evidence that point to the electric field inside the plasmas jet could be a determinant therapeutic mechanism. The device is characterized by producing a cold atmospheric air plasma jet compatible with living tissues at a low heat transfer rate with a temperature on the skin surface below 40 . It has a practical design to be used by physicians and veterinaries during daily practice, with a special focus on the treatment of skin injuries and unhealed ulcers. Plasma diagnostics, including currents-voltage signals, UV-VIS spectroscopy, IR images of the skin, and electric field measurements in the air cold plasma jet are presented. The last is made for the first time in this type of plasma, and them can justify the induction of local electric currents on the wound surface to accelerate healing by highlighting the possible synergy with Reactive Oxygen and Nitrogen Species (RONS) as a decontaminant agent for bacteria (including resistant), fungi and viruses without damaging healthy tissue. A remarkable clinical case study example is reported.
- 1 November 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (11) , 113301
Time resolved plasma diagnostics for pulsed 2.45 GHz hydrogen discharges
A review of the last ten years of advances in temporal resolved plasma diagnostics for pulsed operated 2.45 GHz microwave-driven hydrogen discharges is presented. Special attention has been paid to the study of breakdown and decay processes where some particular phenomena are explored for application in ion sources. Measurements of plasma temperature and density using vacuum ultraviolet spectroscopy, ultra-fast photography, and ion mass spectroscopy are performed in detail, including examples and results.
- 1 November 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (11) , 113301
Time resolved plasma diagnostics for pulsed 2.45 GHz hydrogen discharges
A review of the last ten years of advances in temporal resolved plasma diagnostics for pulsed operated 2.45 GHz microwave-driven hydrogen discharges is presented. Special attention has been paid to the study of breakdown and decay processes where some particular phenomena are explored for application in ion sources. Measurements of plasma temperature and density using vacuum ultraviolet spectroscopy, ultra-fast photography, and ion mass spectroscopy are performed in detail, including examples and results.
- 5 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (7) , 5128-5137
Designing Resonance Microwave Cavities to Optimize Plasma Generation
Methodology for designing the 2.45 GHz microwave coupling system to optimize the hydrogen plasma density in an ECR plasma reactor is presented. Two different plasma generator systems have been studied by experiments and 3D simulations to find the criteria to reach an optimized design. The experimental work includes detailed measurements and calculations of the Electron Energy Distribution Functions (EEDF) and ultrafast photography diagnostics to estimate spatial distributions of plasma unbalanced charge density, potential and electric field for both cases. It demonstrates that to simulate in 3D the distribution of the resonant stationary electric field along the entire microwave driver system can be use to improve the design in order to reach higher plasma densities and temperatures.
- 5 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (7) , 5128-5137
Designing Resonance Microwave Cavities to Optimize Plasma Generation
Methodology for designing the 2.45 GHz microwave coupling system to optimize the hydrogen plasma density in an ECR plasma reactor is presented. Two different plasma generator systems have been studied by experiments and 3D simulations to find the criteria to reach an optimized design. The experimental work includes detailed measurements and calculations of the Electron Energy Distribution Functions (EEDF) and ultrafast photography diagnostics to estimate spatial distributions of plasma unbalanced charge density, potential and electric field for both cases. It demonstrates that to simulate in 3D the distribution of the resonant stationary electric field along the entire microwave driver system can be use to improve the design in order to reach higher plasma densities and temperatures.
- 8 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 47 (1) , 483-487
Review of Spatial Distribution Modes in a 2.45-GHz Hydrogen Plasma
A comprehensive review of plasma distributions modes found by us in a 2.45-GHz hydrogen ECR discharge is presented for the first time. Regular and ultrafast photographs show very interesting spatial plasma shape modes never observed before for this kind of plasmas. The resonance of the discharge chamber is kept by using an optical transparent but microwave shielded quartz window with two tungsten meshes, one on each side. The experiments reveal a strong dependence of the plasma distributions on the magnetic field where the plasma is embedded. Most distributions are steady but two of them show a rotational behavior connected with E × B drift.
- 8 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 47 (1) , 483-487
Review of Spatial Distribution Modes in a 2.45-GHz Hydrogen Plasma
A comprehensive review of plasma distributions modes found by us in a 2.45-GHz hydrogen ECR discharge is presented for the first time. Regular and ultrafast photographs show very interesting spatial plasma shape modes never observed before for this kind of plasmas. The resonance of the discharge chamber is kept by using an optical transparent but microwave shielded quartz window with two tungsten meshes, one on each side. The experiments reveal a strong dependence of the plasma distributions on the magnetic field where the plasma is embedded. Most distributions are steady but two of them show a rotational behavior connected with E × B drift.
- 21 September 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2011 (1) , 090014
The ion source for the commissioning of ELENA ring
The commissioning and first results of the ion source to test the Extremely Low ENergy Antiproton ring ELENA are presented. ELENA is a compact ring for cooling and further deceleration of 5.3 MeV antiproton delivered by CERN Antiproton Decelerator (AD) down to 100 keV. Because of the long AD cycle of 100 s, one ion source for protons and H− with a kinetic energy of 100 keV has been installed for commissioning and start-up. The complete device is described including the control and power subsystems. The beam profiles and the emittance for protons and H− were measured with a wire scanner and a pepper-pot diagnostic. The current was also measured by means of a current transformer. The ion source meets the parameters required by the ELENA testing program in order to tune the decelerator ring before starting with the antiproton beam.
- 21 September 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2011 (1) , 090014
The ion source for the commissioning of ELENA ring
The commissioning and first results of the ion source to test the Extremely Low ENergy Antiproton ring ELENA are presented. ELENA is a compact ring for cooling and further deceleration of 5.3 MeV antiproton delivered by CERN Antiproton Decelerator (AD) down to 100 keV. Because of the long AD cycle of 100 s, one ion source for protons and H− with a kinetic energy of 100 keV has been installed for commissioning and start-up. The complete device is described including the control and power subsystems. The beam profiles and the emittance for protons and H− were measured with a wire scanner and a pepper-pot diagnostic. The current was also measured by means of a current transformer. The ion source meets the parameters required by the ELENA testing program in order to tune the decelerator ring before starting with the antiproton beam.
- 9 October 2014
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 23 (6)
Plasma distributions observed in a 2.45 GHz hydrogen discharge
- 9 October 2014
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 23 (6)
Plasma distributions observed in a 2.45 GHz hydrogen discharge
- 1 March 2014
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 85 (3) , 033310
Influence of microwave driver coupling design on plasma density at Testbench for Ion sources Plasma Studies, a 2.45 GHz Electron Cyclotron Resonance Plasma Reactor
A comparative study of two microwave driver systems (preliminary and optimized) for a 2.45 GHz hydrogen Electron Cyclotron Resonance plasma generator has been conducted. The influence on plasma behavior and parameters of stationary electric field distribution in vacuum, i.e., just before breakdown, along all the microwave excitation system is analyzed. 3D simulations of resonant stationary electric field distributions, 2D simulations of external magnetic field mapping, experimental measurements of incoming and reflected power, and electron temperature and density along the plasma chamber axis have been carried out. By using these tools, an optimized set of plasma chamber and microwave coupler has been designed paying special attention to the optimization of stationary electric field value in the center of the plasma chamber. This system shows a strong stability on plasma behavior allowing a wider range of operational parameters and even sustaining low density plasma formation without external magnetic field. In addition, the optimized system shows the capability to produce values of plasma density four times higher than the preliminary as a consequence of a deeper penetration of the magnetic resonance surface in relative high electric field zone by keeping plasma stability. The increment of the amount of resonance surface embedded in the plasma under high electric field is suggested as a key factor.
- 1 March 2014
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 85 (3) , 033310
Influence of microwave driver coupling design on plasma density at Testbench for Ion sources Plasma Studies, a 2.45 GHz Electron Cyclotron Resonance Plasma Reactor
A comparative study of two microwave driver systems (preliminary and optimized) for a 2.45 GHz hydrogen Electron Cyclotron Resonance plasma generator has been conducted. The influence on plasma behavior and parameters of stationary electric field distribution in vacuum, i.e., just before breakdown, along all the microwave excitation system is analyzed. 3D simulations of resonant stationary electric field distributions, 2D simulations of external magnetic field mapping, experimental measurements of incoming and reflected power, and electron temperature and density along the plasma chamber axis have been carried out. By using these tools, an optimized set of plasma chamber and microwave coupler has been designed paying special attention to the optimization of stationary electric field value in the center of the plasma chamber. This system shows a strong stability on plasma behavior allowing a wider range of operational parameters and even sustaining low density plasma formation without external magnetic field. In addition, the optimized system shows the capability to produce values of plasma density four times higher than the preliminary as a consequence of a deeper penetration of the magnetic resonance surface in relative high electric field zone by keeping plasma stability. The increment of the amount of resonance surface embedded in the plasma under high electric field is suggested as a key factor.
- 1 February 2013
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 22 (1) , 015026
Experimental study of hydrogen plasma breakdown in a 2.45 GHz microwave discharge
- 1 February 2013
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 22 (1) , 015026
Experimental study of hydrogen plasma breakdown in a 2.45 GHz microwave discharge
- 22 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 40 (12) , 3409-3419
Experimental Study of Breakdown Time in a Pulsed 2.45-GHz ECR Hydrogen Plasma Reactor
An electron cyclotron resonance (ECR) plasma reactor developed at the European Spallation Source Bilbao has been operated in pulsed mode at 50 Hz to study the breakdown-process dynamics by time-resolved diagnostics. Injected power, reflected power, electrical-biased probe saturation current, and light emission were measured simultaneously for three different magnetic fields: under ECR, ECR, and asymmetric over ECR profiles. Gas pressure, power, and duty cycle have been used in a parametric study obtaining information about microwave (MW) coupling and plasma formation stages during the breakdown process. The study is relevant for designers that need to extract short beam pulses from a 2.45 ECR ion source for any application because the total breakdown time measured is defined as corresponding to reach the steady-state plasma parameters. A simple model of residual electron density evolution between pulses is proposed to describe the MW coupling as a function of incoming power and duty cycles.
- 22 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 40 (12) , 3409-3419
Experimental Study of Breakdown Time in a Pulsed 2.45-GHz ECR Hydrogen Plasma Reactor
An electron cyclotron resonance (ECR) plasma reactor developed at the European Spallation Source Bilbao has been operated in pulsed mode at 50 Hz to study the breakdown-process dynamics by time-resolved diagnostics. Injected power, reflected power, electrical-biased probe saturation current, and light emission were measured simultaneously for three different magnetic fields: under ECR, ECR, and asymmetric over ECR profiles. Gas pressure, power, and duty cycle have been used in a parametric study obtaining information about microwave (MW) coupling and plasma formation stages during the breakdown process. The study is relevant for designers that need to extract short beam pulses from a 2.45 ECR ion source for any application because the total breakdown time measured is defined as corresponding to reach the steady-state plasma parameters. A simple model of residual electron density evolution between pulses is proposed to describe the MW coupling as a function of incoming power and duty cycles.