Yumin Zhong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yumin Zhong has a total of 204 co-authors. Here are the top co-authors by number of shared publications:
Chen Guo
Department of Radiology, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, PR China (L.H., C.G., R.O., Y.M., L.F., X.Y., Q.W., Y.Z.); PEDiatric Imaging Advanced Technology Research Center, Shanghai, PR China (L.H., C.G., R.O., T.W., X.Y., Q.W, Y.Z)
15 shared publicationsQian Wang
Department of Radiology, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, PR China (L.H., C.G., R.O., Y.M., L.F., X.Y., Q.W., Y.Z.); PEDiatric Imaging Advanced Technology Research Center, Shanghai, PR China (L.H., C.G., R.O., T.W., X.Y., Q.W, Y.Z)
15 shared publicationsLiwei Hu
Department of Radiology, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, PR China (L.H., C.G., R.O., Y.M., L.F., X.Y., Q.W., Y.Z.); PEDiatric Imaging Advanced Technology Research Center, Shanghai, PR China (L.H., C.G., R.O., T.W., X.Y., Q.W, Y.Z)
14 shared publicationsLi-Wei Hu
Department of Radiology, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, 1678 Dong Fang Road, Shanghai 200127, PR China
8 shared publications- Qian Wang
Department of Radiology, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, No.1678 Dong Fang Road, Shanghai 200127, China
8 shared publications Aimin Sun
Department of Radiology, Shanghai Children’s Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China
7 shared publications
Latest Publications
- 9 April 2026
- Published by Elsevier in Academic Radiology
- Vol. 33 (6) , 2542-2554
The Rapid Long-axis Strain-based Prognostic Models Evaluate Composite Adverse Events for Asymptomatic Dextro-Transposition of the Great Arteries Patients after the Switch Operation
- 9 April 2026
- Published by Elsevier in Academic Radiology
- Vol. 33 (6) , 2542-2554
The Rapid Long-axis Strain-based Prognostic Models Evaluate Composite Adverse Events for Asymptomatic Dextro-Transposition of the Great Arteries Patients after the Switch Operation
- 1 February 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 8 (1) , e240557
Prognostic Value of Cardiac MRI–derived Left Atrial and Biventricular Function in Children with Repaired Tetralogy of Fallot
Left atrial dysfunction was present in children with repaired tetralogy of Fallot despite preserved ventricular systolic function. Incorporating impaired left atrial conduit strain with right ventricular functional parameters improved cardiac MRI–based prognostic assessment.
- 1 February 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 8 (1) , e240557
Prognostic Value of Cardiac MRI–derived Left Atrial and Biventricular Function in Children with Repaired Tetralogy of Fallot
Left atrial dysfunction was present in children with repaired tetralogy of Fallot despite preserved ventricular systolic function. Incorporating impaired left atrial conduit strain with right ventricular functional parameters improved cardiac MRI–based prognostic assessment.
- 14 January 2026
- Published by Springer Nature in Chinese Journal of Academic Radiology
- Vol. 9 (1) , 49-56
The study of altered brain structure in preterm infants with low grade intraventricular hemorrhage utilizing 3D T1WI whole brain MR images
- 14 January 2026
- Published by Springer Nature in Chinese Journal of Academic Radiology
- Vol. 9 (1) , 49-56
The study of altered brain structure in preterm infants with low grade intraventricular hemorrhage utilizing 3D T1WI whole brain MR images
- 1 December 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (12)
Evolution and dynamics of vortex rings in a confined and asymmetric region
Vortex ring evolution in confined asymmetric geometries is critical to biological and engineering flows, yet the combined effects of confinement and asymmetry introduce dynamics not captured by studies of either factor alone. This study employs numerical simulations to investigate the three-dimensional evolution of vortex rings under such combined conditions, focusing on the roles of eccentricity (ε), Reynolds number (Re), and stroke ratio (L/D0). The evolution of the primary vortex ring (PVR) before transition into turbulence proceeds through three stages: symmetric growth, asymmetric inclination, and reorientation toward the confinement axis. The inclination arises from asymmetric interactions between the PVR and the boundaries. This interaction generates a boundary vortex ring (BVR) of unequal strength on the near-wall and far-wall sides, causing a differential circulation decay that drives the inclination. The reorientation stage is initiated as the PVR–BVR interaction strengthens with the growing inclination. This interaction promotes vorticity annihilation between opposite-signed segments of the PVR, and it is this annihilation-induced circulation loss that primarily redirects the vortex trajectory. Based on the slug model and the circulation-decay model for confined symmetric vortex rings, a scaling model is developed that quantitatively links the asymmetric circulation decay to the evolving inclination angle, showing good agreement with the simulations. The present study reveals the evolution and dynamics of vortex rings under confined asymmetric region, providing insight into vortex-mediated transport and dissipation in environments such as intracardiac filling.
- 1 December 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (12)
Evolution and dynamics of vortex rings in a confined and asymmetric region
Vortex ring evolution in confined asymmetric geometries is critical to biological and engineering flows, yet the combined effects of confinement and asymmetry introduce dynamics not captured by studies of either factor alone. This study employs numerical simulations to investigate the three-dimensional evolution of vortex rings under such combined conditions, focusing on the roles of eccentricity (ε), Reynolds number (Re), and stroke ratio (L/D0). The evolution of the primary vortex ring (PVR) before transition into turbulence proceeds through three stages: symmetric growth, asymmetric inclination, and reorientation toward the confinement axis. The inclination arises from asymmetric interactions between the PVR and the boundaries. This interaction generates a boundary vortex ring (BVR) of unequal strength on the near-wall and far-wall sides, causing a differential circulation decay that drives the inclination. The reorientation stage is initiated as the PVR–BVR interaction strengthens with the growing inclination. This interaction promotes vorticity annihilation between opposite-signed segments of the PVR, and it is this annihilation-induced circulation loss that primarily redirects the vortex trajectory. Based on the slug model and the circulation-decay model for confined symmetric vortex rings, a scaling model is developed that quantitatively links the asymmetric circulation decay to the evolving inclination angle, showing good agreement with the simulations. The present study reveals the evolution and dynamics of vortex rings under confined asymmetric region, providing insight into vortex-mediated transport and dissipation in environments such as intracardiac filling.
- Open Access
- 7 January 2025
- Published by Elsevier in European Journal of Radiology Open
- Vol. 14, 100631
Assessment of hemodynamic disturbances and impaired ventricular filling in asymptomatic fontan patients: A 4D flow CMR study
- 7 January 2025
- Published by Elsevier in European Journal of Radiology Open
- Vol. 14, 100631
Open AccessAssessment of hemodynamic disturbances and impaired ventricular filling in asymptomatic fontan patients: A 4D flow CMR study
- Open Access
- 22 October 2024
- Published by Elsevier in JACC: Asia
- Vol. 4 (12) , 912-924
Right Ventricular Restrictive Physiology Is Associated With Right Ventricular Direct Flow From 4D Flow CMR
- 22 October 2024
- Published by Elsevier in JACC: Asia
- Vol. 4 (12) , 912-924
Open AccessRight Ventricular Restrictive Physiology Is Associated With Right Ventricular Direct Flow From 4D Flow CMR
- 18 October 2024
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 200 (20) , 1981-1989
From age-specific to size-specific dose protocol for paediatric head computed tomography: a simple practical strategy for necessity assessment and parameter setting
This study proposes a practical approach to assessing the need for and determining the transitioning parameters from age-specific to size-specific dose protocols in paediatric head computed tomography examinations. It was designed to begin with the two different age-specific protocols currently applied on paediatric patients of 1 y ≤ age ≤ 6 y (21.34 mGy) and those of age >6 y (34.73 mGy). One characteristic size (HDthreshold) was found by measuring anteroposterior head diameter on historical topograms and used with age to set 135 cases into four groups for investigation (A, ≤6y, ≤HDthreshold; B, ≤6y, >HDthreshold; C, >6y, ≤HDthreshold; and D, >6 y, >HDthreshold). The image quality was compared in both subjective and objective manners. Results suggest patients in Group C may have received a potential overdose (38%), while the exposure setting for Group D may replace that for B. The proposed strategy was sufficient to assess the necessity and determine the transitioning parameters from age- to size-specific dose protocols.
- 18 October 2024
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 200 (20) , 1981-1989
From age-specific to size-specific dose protocol for paediatric head computed tomography: a simple practical strategy for necessity assessment and parameter setting
This study proposes a practical approach to assessing the need for and determining the transitioning parameters from age-specific to size-specific dose protocols in paediatric head computed tomography examinations. It was designed to begin with the two different age-specific protocols currently applied on paediatric patients of 1 y ≤ age ≤ 6 y (21.34 mGy) and those of age >6 y (34.73 mGy). One characteristic size (HDthreshold) was found by measuring anteroposterior head diameter on historical topograms and used with age to set 135 cases into four groups for investigation (A, ≤6y, ≤HDthreshold; B, ≤6y, >HDthreshold; C, >6y, ≤HDthreshold; and D, >6 y, >HDthreshold). The image quality was compared in both subjective and objective manners. Results suggest patients in Group C may have received a potential overdose (38%), while the exposure setting for Group D may replace that for B. The proposed strategy was sufficient to assess the necessity and determine the transitioning parameters from age- to size-specific dose protocols.
- Open Access
- 1 October 2024
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 14 (10) , 7200-7217
Characteristics of altered biventricular hemodynamics after arterial switch operation for patients with d-transposition of the great arteries with preserved ejection fraction: a four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) study
Background: The long-term monitoring of biventricular function is essential to identify potential functional decline in patients following the arterial switch operation (ASO). The underlying pathophysiological mechanisms responsible for altered biventricular hemodynamics in ASO patients are not yet well understood. This study sought to: (I) compare the biventricular kinetic energy (KE) and vorticity of ASO patients and age- and sex-matched controls; (II) investigate the associations of four-dimensional (4D) flow biventricular hemodynamics parameters and neo-aortic root dilation, supravalvular pulmonary stenosis, and pulmonary artery transvalvular pressure difference. Methods: A total of 34 patients with dextro-transposition of the great arteries (D-TGA) who underwent ASO, and 17 age- and gender-matched healthy controls were prospectively recruited for this study. All the subjects underwent cine and 4D flow and late gadolinium enhancement scans, and all the patients underwent echocardiography within two weeks of cardiovascular magnetic resonance (CMR) imaging. The following four flow components were analyzed: direct flow, retained inflow, delayed ejection flow, and residual volume. In addition, the following six phasic blood flow KE parameters, normalized to the end-diastolic volume (EDV) and vorticity, were analyzed for both the left ventricle (LV) and right ventricle (RV): peak systolic phase, average systolic phase, peak diastolic phase, average diastolic phase, peak E-wave phase, and peak A-wave phase. The independent sample Student’s t-test, Mann-Whitney U-test, univariable and multivariable stepwise regression analyses, intra and inter-observer variability analyses were used to compare patients and controls. Results: In relation to the LV, the D-TGA patients had significantly decreased average vorticity, peak systolic vorticity, systolic vorticity, diastolic vorticity, and peak A-wave vorticity compared to the controls (all PEDV), and peak and average vorticity compared to the non-pulmonary stenosis group (all PEDV, peak E-wave KEiEDV peak A-wave KEiEDV, and average vorticity were associated a with transvalvular pressure difference (β=13.54, PEDV; β=105.26, PEDV; β=−49.36, P=0.027 for peak A-wave KEiEDV; and β=−56.37, PConclusions: We found that 4D flow biventricular hemodynamics were more sensitive markers than the ejection fraction in the postoperative D-TGA patients. The RV diastolic KEiEDV parameters and average vorticity were risk factors for pulmonary artery obstruction in the multivariable model.
- 1 October 2024
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 14 (10) , 7200-7217
Open AccessCharacteristics of altered biventricular hemodynamics after arterial switch operation for patients with d-transposition of the great arteries with preserved ejection fraction: a four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) study
Background: The long-term monitoring of biventricular function is essential to identify potential functional decline in patients following the arterial switch operation (ASO). The underlying pathophysiological mechanisms responsible for altered biventricular hemodynamics in ASO patients are not yet well understood. This study sought to: (I) compare the biventricular kinetic energy (KE) and vorticity of ASO patients and age- and sex-matched controls; (II) investigate the associations of four-dimensional (4D) flow biventricular hemodynamics parameters and neo-aortic root dilation, supravalvular pulmonary stenosis, and pulmonary artery transvalvular pressure difference. Methods: A total of 34 patients with dextro-transposition of the great arteries (D-TGA) who underwent ASO, and 17 age- and gender-matched healthy controls were prospectively recruited for this study. All the subjects underwent cine and 4D flow and late gadolinium enhancement scans, and all the patients underwent echocardiography within two weeks of cardiovascular magnetic resonance (CMR) imaging. The following four flow components were analyzed: direct flow, retained inflow, delayed ejection flow, and residual volume. In addition, the following six phasic blood flow KE parameters, normalized to the end-diastolic volume (EDV) and vorticity, were analyzed for both the left ventricle (LV) and right ventricle (RV): peak systolic phase, average systolic phase, peak diastolic phase, average diastolic phase, peak E-wave phase, and peak A-wave phase. The independent sample Student’s t-test, Mann-Whitney U-test, univariable and multivariable stepwise regression analyses, intra and inter-observer variability analyses were used to compare patients and controls. Results: In relation to the LV, the D-TGA patients had significantly decreased average vorticity, peak systolic vorticity, systolic vorticity, diastolic vorticity, and peak A-wave vorticity compared to the controls (all PEDV), and peak and average vorticity compared to the non-pulmonary stenosis group (all PEDV, peak E-wave KEiEDV peak A-wave KEiEDV, and average vorticity were associated a with transvalvular pressure difference (β=13.54, PEDV; β=105.26, PEDV; β=−49.36, P=0.027 for peak A-wave KEiEDV; and β=−56.37, PConclusions: We found that 4D flow biventricular hemodynamics were more sensitive markers than the ejection fraction in the postoperative D-TGA patients. The RV diastolic KEiEDV parameters and average vorticity were risk factors for pulmonary artery obstruction in the multivariable model.
- 5 January 2024
- Published by Springer Nature in European Radiology
- Vol. 34 (8) , 5487-5500
Assessment of right ventricular diastolic function in pediatric patients with repaired tetralogy of Fallot by cardiovascular magnetic resonance and echocardiography
Objectives Cardiovascular magnetic resonance (CMR) imaging is routinely performed for assessing right ventricular (RV) systolic but not diastolic function. We aimed to investigate CMR-based assessment of RV diastolic function in pediatric patients with repaired tetralogy of Fallot (rTOF), compared to transthoracic echocardiography (TTE) measurements. Methods A total of 130 consecutive pediatric patients with rTOF who underwent clinically indicated CMR and same-day TTE were included. Forty-three controls were recruited. Phase-contrast images were used to measure trans-tricuspid valve flow velocities during early (E) and late diastolic (A) phases (measured in cm/s). Feature tracking of the tricuspid annulus was performed to derive early (e′) and late diastolic (a′) myocardial velocities (measured in cm/s). RV diastolic function was evaluated by E/A ratio, E/e′ ratio, and E-wave deceleration time (measured in milliseconds). Regression analyses were utilized to identify potential variables associated with RV diastolic dysfunction (DD). The performance of CMR-derived parameters in diagnosing RV DD was assessed using receiver-operating characteristic analyses. Results Good agreement was found between CMR and TTE measurements (ICC 0.70–0.89). Patients with RV DD (n = 67) showed significantly different CMR-derived parameters including E and e′ velocities, and E/A and E/e′ ratio, compared to patients without DD (n = 63) (all p < 0.05). CMR-derived E and e′ velocities and E/e′ ratio were independent predictors of RV DD. E/e′ of 5.8 demonstrated the highest discrimination of RV DD (AUC 0.76, sensitivity 70%, specificity 86%). Conclusions CMR-derived parameters showed good agreement with TTE parameters in determining RV DD. CMR-derived E/e′ was proved to be the most effective in identifying RV DD. Clinical relevance statement This study demonstrated the feasibility and efficacy of CMR in assessing diastolic function in pediatric patients. RV DD was presented in over half of patients according to current TTE guidelines, highlighting the need for assessing RV diastolic function during follow-up. Key Points • Routinely acquired cine and phase-contrast cardiovascular magnetic resonance (CMR) images yielded right ventricular (RV) diastolic parameters which demonstrated good agreement with transthoracic echocardiography (TTE) measurements. • There was a high prevalence of RV diastolic function impairment in pediatric patients with repaired tetralogy of Fallot (rTOF). • CMR is a reliable complementary modality of TTE for RV diastolic function evaluation.
- 5 January 2024
- Published by Springer Nature in European Radiology
- Vol. 34 (8) , 5487-5500
Assessment of right ventricular diastolic function in pediatric patients with repaired tetralogy of Fallot by cardiovascular magnetic resonance and echocardiography
Objectives Cardiovascular magnetic resonance (CMR) imaging is routinely performed for assessing right ventricular (RV) systolic but not diastolic function. We aimed to investigate CMR-based assessment of RV diastolic function in pediatric patients with repaired tetralogy of Fallot (rTOF), compared to transthoracic echocardiography (TTE) measurements. Methods A total of 130 consecutive pediatric patients with rTOF who underwent clinically indicated CMR and same-day TTE were included. Forty-three controls were recruited. Phase-contrast images were used to measure trans-tricuspid valve flow velocities during early (E) and late diastolic (A) phases (measured in cm/s). Feature tracking of the tricuspid annulus was performed to derive early (e′) and late diastolic (a′) myocardial velocities (measured in cm/s). RV diastolic function was evaluated by E/A ratio, E/e′ ratio, and E-wave deceleration time (measured in milliseconds). Regression analyses were utilized to identify potential variables associated with RV diastolic dysfunction (DD). The performance of CMR-derived parameters in diagnosing RV DD was assessed using receiver-operating characteristic analyses. Results Good agreement was found between CMR and TTE measurements (ICC 0.70–0.89). Patients with RV DD (n = 67) showed significantly different CMR-derived parameters including E and e′ velocities, and E/A and E/e′ ratio, compared to patients without DD (n = 63) (all p < 0.05). CMR-derived E and e′ velocities and E/e′ ratio were independent predictors of RV DD. E/e′ of 5.8 demonstrated the highest discrimination of RV DD (AUC 0.76, sensitivity 70%, specificity 86%). Conclusions CMR-derived parameters showed good agreement with TTE parameters in determining RV DD. CMR-derived E/e′ was proved to be the most effective in identifying RV DD. Clinical relevance statement This study demonstrated the feasibility and efficacy of CMR in assessing diastolic function in pediatric patients. RV DD was presented in over half of patients according to current TTE guidelines, highlighting the need for assessing RV diastolic function during follow-up. Key Points • Routinely acquired cine and phase-contrast cardiovascular magnetic resonance (CMR) images yielded right ventricular (RV) diastolic parameters which demonstrated good agreement with transthoracic echocardiography (TTE) measurements. • There was a high prevalence of RV diastolic function impairment in pediatric patients with repaired tetralogy of Fallot (rTOF). • CMR is a reliable complementary modality of TTE for RV diastolic function evaluation.