PSPierre-Loup Schaefer

Pierre-Loup Schaefer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Pierre-Loup Schaefer has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Gregory Chagnon

    Université Grenoble Alpes, CNRS, UMR 5525, VetAgro Sup, Grenoble INP, TIMC, Grenoble, France

    3 shared publications
  • Alexandre Moreau-Gaudry

    CNRS, Grenoble INP, CHU Grenoble Alpes, TIMC-IMAG, University of Grenoble Alpes, 38000, Grenoble, France

    2 shared publications
  • A. Moreau-Gaudry

    TIMC-IMAG, Université Grenoble Alpes, CNRS, CHU Grenoble Alpes, Institute of Engineering Université Grenoble Alpes

    1 shared publication
  • G. Barrier

    TIMC-IMAG, Université Grenoble Alpes, CNRS, CHU Grenoble Alpes, Institute of Engineering Université Grenoble Alpes

    1 shared publication
  • T. Alonso

    TIMC-IMAG, Université Grenoble Alpes, CNRS, CHU Grenoble Alpes, Institute of Engineering Université Grenoble Alpes

    1 shared publication

Latest Publications

  • Optimized needle shape reconstruction using experimentally based strain sensors positioning

    by Pierre-Loup Schaefer, Grégory Chagnon, Alexandre Moreau-Gaudry

    Needles are tools that are used daily during minimally invasive procedures. During the insertions, needles may be affected by deformations which may threaten the success of the procedure. To tackle this problem, needles with embedded strain sensors have been developed and associated with navigation systems. The localization of the needle in the tissues is then obtained in real time by reconstruction from the strain measurements, allowing the physician to optimize its gesture. As the number of strain sensors embedded is limited in number, their positions on the needle have a great impact on the accuracy of the shape reconstruction. The main contribution of this paper is a novel strain sensor positioning method to improve the reconstruction accuracy. A notable feature of our method is the use of experimental needle insertion data, which increases the relevancy of the resulting sensor optimal locations. To the best of the author’s knowledge, no experimentally based needle sensor positioning method has been presented yet. Reconstruction validations from clinical data show that the localization accuracy of the needle tip is improved by almost 40% with optimal locations compared with equidistant locations when reconstructing with two sensor triplets or more.


  • Strain Gauges Based 3D Shape Monitoring of Beam Structures Using Finite Width Gauge Model

    by P.-L. Schaefer, G. Barrier, G. Chagnon, T. Alonso, A. Moreau-Gaudry


  • Open Access

    Advanced sensors placement for accurate 3D needle shape reconstruction

    by Pierre-Loup Schaefer, Gregory Chagnon, Alexandre Moreau-Gaudry

    Needles are tools widely used in minimally invasive surgery. During such procedures the localization of the needle and its tip is a challenging situation because of the needle deformations due to its interactions with tissues. To tackle this problem, instrumented needles with sensors have been currently developed to allow needle reconstruction and tip localization. In conventional surgery this difficulty is overcome by medical imaging. The interest in using an instrumented needle resides in the possible dispense of medical imaging. This papers develops new methods to reconstruct needles in three dimensions and to find the locations of sensors which minimizes the error of reconstruction of the needle. A notable feature of our method is that input data are based on real needle data, that should assure a better representation of reality. Reconstructions simulated with 22 gauge 200 mm long needles show that the localization of the needle tip is more accurate by 18% to 52% with optimal sensors positions compared to equidistant sensors positions.