Hasan Mahmood Khan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hasan Mahmood Khan has a total of 102 co-authors. Here are the top co-authors by number of shared publications:
- Javed Ali Khan
Department of Chemistry, Abdul Wali Khan University Mardan, Mardan, Pakistan
12 shared publications - Murtaza Sayed
Radiation and Environmental Chemistry Laboratory, National Centre of Excellence in Physical Chemistry, University of Peshawar, Peshawar 25120, Pakistan
10 shared publications Henry Delincée
Institute of Nutritional Physiology, Federal Research, Centre for Nutrition, Haid-und-Neu Str. 9, D-76131 Karlsruhe, Germany
9 shared publicationsNoor S. Shah
8 shared publicationsM. Ismail
A Radiation and Environmental Chemistry Laboratory , National Centre of Excellence in Physical Chemistry, University of Peshawar , Peshawar 25120 , Pakistan
5 shared publicationsAshfaq A. Khan
University of Peshawar
4 shared publications
Latest Publications
- Open Access
Exhaustive Photocatalytic Lindane Degradation by Combined Simulated Solar Light-Activated Nanocrystalline TiO2 and Inorganic Oxidants
Organochlorine compounds (OCs) are very toxic, highly persistent, and ubiquitous contaminants in the environment. Degradation of lindane, a selected OC, by simulated solar light-activated TiO2 (SSLA-TiO2) photocatalysis was investigated. The film types of the TiO2 photocatalyst were prepared using a dip-coating method. The physical properties of the films were investigated using X-ray diffraction, transmission electron microscopy, and environmental scanning electron microscopy. The SSLA-TiO2 photocatalysis led to a lindane removal of 23% in 6 h, with 0.042 h−1 of an observed pseudo first-order rate constant (kobs). The SSLA-TiO2 photocatalysis efficiency was greatly enhanced by adding hydrogen peroxide (H2O2), persulfate (S2O82−), or both combined, corresponding to a 64%, 89%, and 99% lindane removal in the presence of 200 µM of H2O2, S2O82−, or equimolar H2O2-S2O82−, respectively. The hydroxyl and sulfate radicals mainly participated in lindane degradation, proven by the results of a radical scavenger study. The degradation kinetics were hindered in the presence of the water constituents, indicated by a 61%, 35%, 50%, 70%, 88%, and 91% degradation of lindane in 6 h, using a SSLA-TiO2/S2O82−/H2O2 photocatalysis system containing 1.0 mg L−1 humic acid (HA), or 1 mM of CO32−, HCO3−, NO3−, SO42−, and Cl−, respectively. The TiO2 film demonstrated high reusability during four runs of lindane decomposition experiments. The SSLA-TiO2/S2O82−/H2O2 photocatalysis is very effective for the elimination of a persistent OC, lindane, from a water environment.
Open AccessExhaustive Photocatalytic Lindane Degradation by Combined Simulated Solar Light-Activated Nanocrystalline TiO2 and Inorganic Oxidants
Organochlorine compounds (OCs) are very toxic, highly persistent, and ubiquitous contaminants in the environment. Degradation of lindane, a selected OC, by simulated solar light-activated TiO2 (SSLA-TiO2) photocatalysis was investigated. The film types of the TiO2 photocatalyst were prepared using a dip-coating method. The physical properties of the films were investigated using X-ray diffraction, transmission electron microscopy, and environmental scanning electron microscopy. The SSLA-TiO2 photocatalysis led to a lindane removal of 23% in 6 h, with 0.042 h−1 of an observed pseudo first-order rate constant (kobs). The SSLA-TiO2 photocatalysis efficiency was greatly enhanced by adding hydrogen peroxide (H2O2), persulfate (S2O82−), or both combined, corresponding to a 64%, 89%, and 99% lindane removal in the presence of 200 µM of H2O2, S2O82−, or equimolar H2O2-S2O82−, respectively. The hydroxyl and sulfate radicals mainly participated in lindane degradation, proven by the results of a radical scavenger study. The degradation kinetics were hindered in the presence of the water constituents, indicated by a 61%, 35%, 50%, 70%, 88%, and 91% degradation of lindane in 6 h, using a SSLA-TiO2/S2O82−/H2O2 photocatalysis system containing 1.0 mg L−1 humic acid (HA), or 1 mM of CO32−, HCO3−, NO3−, SO42−, and Cl−, respectively. The TiO2 film demonstrated high reusability during four runs of lindane decomposition experiments. The SSLA-TiO2/S2O82−/H2O2 photocatalysis is very effective for the elimination of a persistent OC, lindane, from a water environment.
- Open Access
- 21 February 2018
- Published by IntechOpen
Competition Kinetics: An Experimental Approach
In this chapter, free radical kinetics with the help of competition kinetics and some experimental results calculated by competition kinetics to find out the rate constant of reactive species (●OH, eaq−, ●H) with target compound, which is used by radiation chemists is briefly discussed. The competition kinetics method is well validated by taking ciprofloxacin, norfloxacin and bezafibrate as example compounds. The bimolecular rate constants of hydroxyl radical, hydrate electron and hydrogen atom has been calculated for example solute species (ciprofloxacin, norfloxacin and bezafibrate).
- 21 February 2018
- Published by IntechOpen
Open AccessCompetition Kinetics: An Experimental Approach
In this chapter, free radical kinetics with the help of competition kinetics and some experimental results calculated by competition kinetics to find out the rate constant of reactive species (●OH, eaq−, ●H) with target compound, which is used by radiation chemists is briefly discussed. The competition kinetics method is well validated by taking ciprofloxacin, norfloxacin and bezafibrate as example compounds. The bimolecular rate constants of hydroxyl radical, hydrate electron and hydrogen atom has been calculated for example solute species (ciprofloxacin, norfloxacin and bezafibrate).
- 10 January 2018
- Published by Walter de Gruyter GmbH in Zeitschrift für Physikalische Chemie
- Vol. 232 (4) , 545-558
Degradation of Acetaminophen in Aqueous Media by H2O2 Assisted Gamma Irradiation Process
In the present study, degradation of acetaminophen (ACT) aqueous solution was investigated up to an absorbed γ-irradiation dose of 1000 Gy. The effects of various additives on the degradation efficiency of ACT were also studied. The results showed that ACT degradation was increased with the increase of an absorbed dose. Based on spectrophotometric analysis, 82.5% degradation of the initial ACT concentration (9.98×10−5 M) was easily achieved at an absorbed dose of 1000 Gy. The decay of ACT followed pseudo-first order reaction kinetics at different initial concentrations. The radiation chemical yield (G-value) decreased with the increase of an absorbed dose, however at a specific absorbed dose G-values increased with the increase of ACT initial concentration. The addition of H2O2 in the range of 0.1–0.7% was effective for degradation of ACT. The degradation of ACT was inhibited in both acidic and basic solutions while maximium degradation effiency was acheived at nearly neautral solution pH, 7.6. The degradation process was markedly enhanced under oxidative conditions while strongly restrained under reductive conditions, which suggests the key role of oxidative radicals (˙OH) in the degradation of ACT.
- 10 January 2018
- Published by Walter de Gruyter GmbH in Zeitschrift für Physikalische Chemie
- Vol. 232 (4) , 545-558
Degradation of Acetaminophen in Aqueous Media by H2O2 Assisted Gamma Irradiation Process
In the present study, degradation of acetaminophen (ACT) aqueous solution was investigated up to an absorbed γ-irradiation dose of 1000 Gy. The effects of various additives on the degradation efficiency of ACT were also studied. The results showed that ACT degradation was increased with the increase of an absorbed dose. Based on spectrophotometric analysis, 82.5% degradation of the initial ACT concentration (9.98×10−5 M) was easily achieved at an absorbed dose of 1000 Gy. The decay of ACT followed pseudo-first order reaction kinetics at different initial concentrations. The radiation chemical yield (G-value) decreased with the increase of an absorbed dose, however at a specific absorbed dose G-values increased with the increase of ACT initial concentration. The addition of H2O2 in the range of 0.1–0.7% was effective for degradation of ACT. The degradation of ACT was inhibited in both acidic and basic solutions while maximium degradation effiency was acheived at nearly neautral solution pH, 7.6. The degradation process was markedly enhanced under oxidative conditions while strongly restrained under reductive conditions, which suggests the key role of oxidative radicals (˙OH) in the degradation of ACT.
- 10 January 2018
- Published by Walter de Gruyter GmbH in Zeitschrift für Physikalische Chemie
- Vol. 232 (4) , 507-525
Removal of Acid Yellow 17 Dye by Fenton Oxidation Process
In the present research work the degradation of acid yellow 17 (AY 17) by H2O2/Fe2+ was investigated. The effect of various conditions such as pH value, temperature, conc. of H2O2, Fe2+, conc. of AY 17 were studied. Additionally the scavenging effects of various anions such as Cl−, SO4 2−, CO3 2− and HCO3 −, on percent degradation of AY 17 were examined. It was found that these anions decrease percent degradation as well as rate of degradation reaction. The optimum conditions were determined as [AY 17]=[Fe2+]=0.06 mM [H2O2]=0.9 mM, and pH 3.0 for 60 min of reaction time. It was found that at optimum conditions 89% degradation of AY17 was achieved. The degradation kinetics of AY17 followed pseudo-first-order reaction kinetics. Thermodynamic studies under natural conditions showed positive value of ∆H (enthalpy) which indicates the degradation process is endothermic.
- 10 January 2018
- Published by Walter de Gruyter GmbH in Zeitschrift für Physikalische Chemie
- Vol. 232 (4) , 507-525
Removal of Acid Yellow 17 Dye by Fenton Oxidation Process
In the present research work the degradation of acid yellow 17 (AY 17) by H2O2/Fe2+ was investigated. The effect of various conditions such as pH value, temperature, conc. of H2O2, Fe2+, conc. of AY 17 were studied. Additionally the scavenging effects of various anions such as Cl−, SO4 2−, CO3 2− and HCO3 −, on percent degradation of AY 17 were examined. It was found that these anions decrease percent degradation as well as rate of degradation reaction. The optimum conditions were determined as [AY 17]=[Fe2+]=0.06 mM [H2O2]=0.9 mM, and pH 3.0 for 60 min of reaction time. It was found that at optimum conditions 89% degradation of AY17 was achieved. The degradation kinetics of AY17 followed pseudo-first-order reaction kinetics. Thermodynamic studies under natural conditions showed positive value of ∆H (enthalpy) which indicates the degradation process is endothermic.
- Open Access
- 1 March 2017
- Published by SciELO Agencia Nacional de Investigacion y Desarrollo (ANID) in Journal of the Chilean Chemical Society
- Vol. 62 (1) , 3359-3364
REMOVAL OF CRYSTAL VIOLET DYE FROM AQUEOUS SOLUTION BY GAMMA IRRADIATION
In this study the radiation-induced degradation of crystal violet (CV) dye under various experimental conditions has been investigated. D 0.5 , D 0.9 and D 0.99 values suggests that lower doses are required for 50%, 90% and 99% removal of CV dye when the sample solution contains excessive amount of • OH radicals. The removal efficiency of CV dye in terms of G-values was also calculated under each reaction conditions. The results showed that • OH radicals are playing effective role in the degradation of CV dye as compared to e aq-and • H radicals. The gamma irradiation process effectively degraded CV dye at all pH values. The organic byproducts were examined and accordingly degradation pathway was proposed.
- 1 March 2017
- Published by SciELO Agencia Nacional de Investigacion y Desarrollo (ANID) in Journal of the Chilean Chemical Society
- Vol. 62 (1) , 3359-3364
Open AccessREMOVAL OF CRYSTAL VIOLET DYE FROM AQUEOUS SOLUTION BY GAMMA IRRADIATION
In this study the radiation-induced degradation of crystal violet (CV) dye under various experimental conditions has been investigated. D 0.5 , D 0.9 and D 0.99 values suggests that lower doses are required for 50%, 90% and 99% removal of CV dye when the sample solution contains excessive amount of • OH radicals. The removal efficiency of CV dye in terms of G-values was also calculated under each reaction conditions. The results showed that • OH radicals are playing effective role in the degradation of CV dye as compared to e aq-and • H radicals. The gamma irradiation process effectively degraded CV dye at all pH values. The organic byproducts were examined and accordingly degradation pathway was proposed.
- 13 December 2016
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry A
- Vol. 120 (50) , 9916-9931
Efficient Photocatalytic Degradation of Norfloxacin in Aqueous Media by Hydrothermally Synthesized Immobilized TiO2/Ti Films with Exposed {001} Facets
In this study, a novel immobilized TiO2/Ti film with exposed {001} facets was prepared via a facile one-pot hydrothermal route for the degradation of norfloxacin from aqueous media. The effects of various hydrothermal conditions (i.e., solution pH, hydrothermal time (HT) and HF concentration) on the growth of {001} faceted TiO2/Ti film were investigated. The maximum photocatalytic performance of {001} faceted TiO2/Ti film was observed when prepared at pH 2.62, HT of 3 h and at HF concentration of 0.02 M. The as-prepared {001} faceted TiO2/Ti films were fully characterized by field-emission scanning electron microscope (FE-SEM), X-ray diffraction (XRD), high resolution transmission electron microscope (HR-TEM), and X-ray photoelectron spectroscopy (XPS). More importantly, the as-prepared {001} faceted TiO2/Ti film exhibited excellent photocatalytic performance toward degradation of norfloxacin in various water matrices (Milli-Q water, tap water, river water and synthetic wastewater). The individual influence of various anions (SO42–, HCO3–, NO3–, Cl–) and cations (K+, Ca2+, Mg2+, Cu2+, Na+, Fe3+) usually present in the real water samples on the photocatalytic performance of as-prepared TiO2/Ti film with exposed {001} facet was investigated. The mechanistic studies revealed that •OH is mainly involved in the photocatalytic degradation of norfloxacin by {001} faceted TiO2/Ti film. In addition, norfloxacin degradation byproducts were investigated, on the basis of which degradation schemes were proposed.
- 13 December 2016
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry A
- Vol. 120 (50) , 9916-9931
Efficient Photocatalytic Degradation of Norfloxacin in Aqueous Media by Hydrothermally Synthesized Immobilized TiO2/Ti Films with Exposed {001} Facets
In this study, a novel immobilized TiO2/Ti film with exposed {001} facets was prepared via a facile one-pot hydrothermal route for the degradation of norfloxacin from aqueous media. The effects of various hydrothermal conditions (i.e., solution pH, hydrothermal time (HT) and HF concentration) on the growth of {001} faceted TiO2/Ti film were investigated. The maximum photocatalytic performance of {001} faceted TiO2/Ti film was observed when prepared at pH 2.62, HT of 3 h and at HF concentration of 0.02 M. The as-prepared {001} faceted TiO2/Ti films were fully characterized by field-emission scanning electron microscope (FE-SEM), X-ray diffraction (XRD), high resolution transmission electron microscope (HR-TEM), and X-ray photoelectron spectroscopy (XPS). More importantly, the as-prepared {001} faceted TiO2/Ti film exhibited excellent photocatalytic performance toward degradation of norfloxacin in various water matrices (Milli-Q water, tap water, river water and synthetic wastewater). The individual influence of various anions (SO42–, HCO3–, NO3–, Cl–) and cations (K+, Ca2+, Mg2+, Cu2+, Na+, Fe3+) usually present in the real water samples on the photocatalytic performance of as-prepared TiO2/Ti film with exposed {001} facet was investigated. The mechanistic studies revealed that •OH is mainly involved in the photocatalytic degradation of norfloxacin by {001} faceted TiO2/Ti film. In addition, norfloxacin degradation byproducts were investigated, on the basis of which degradation schemes were proposed.
- 28 March 2016
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 23 (13) , 13155-13168
Degradation of quinolone antibiotic, norfloxacin, in aqueous solution using gamma-ray irradiation
This study reports the efficiency of gamma-ray irradiation to degrade quinolone antibiotic, norfloxacin, in aqueous solution. Laboratory batch experiments were conducted to determine the “pseudo-first” order degradation kinetics of norfloxacin in the concentration ranges of 3.4–16.1 mg L−1 by gamma-ray irradiation. The dose constant was found to be dependent on the initial concentration of norfloxacin and gamma-ray irradiation dose rate (D r). The saturation of norfloxacin sample solutions with N2, air or N2O, and the presence of tert-butanol and 2-propanol showed that •OH played more crucial role in the degradation of norfloxacin. The second order rate constants of •OH, eaq −, and •H with norfloxacin were calculated to be 8.81 × 109, 9.54 × 108, and 1.10 × 109 M−1 s−1, respectively. The effects of various additives including CO3 2−, HCO3 −, NO3 −, NO2 −, and thiourea and the pH of the medium on the degradation of norfloxacin were also investigated. Norfloxacin degradation was lower in surface water and wastewater than in ultrapure water. Several degradation byproducts of norfloxacin were identified from which the possible degradation pathway was proposed.
- 28 March 2016
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 23 (13) , 13155-13168
Degradation of quinolone antibiotic, norfloxacin, in aqueous solution using gamma-ray irradiation
This study reports the efficiency of gamma-ray irradiation to degrade quinolone antibiotic, norfloxacin, in aqueous solution. Laboratory batch experiments were conducted to determine the “pseudo-first” order degradation kinetics of norfloxacin in the concentration ranges of 3.4–16.1 mg L−1 by gamma-ray irradiation. The dose constant was found to be dependent on the initial concentration of norfloxacin and gamma-ray irradiation dose rate (D r). The saturation of norfloxacin sample solutions with N2, air or N2O, and the presence of tert-butanol and 2-propanol showed that •OH played more crucial role in the degradation of norfloxacin. The second order rate constants of •OH, eaq −, and •H with norfloxacin were calculated to be 8.81 × 109, 9.54 × 108, and 1.10 × 109 M−1 s−1, respectively. The effects of various additives including CO3 2−, HCO3 −, NO3 −, NO2 −, and thiourea and the pH of the medium on the degradation of norfloxacin were also investigated. Norfloxacin degradation was lower in surface water and wastewater than in ultrapure water. Several degradation byproducts of norfloxacin were identified from which the possible degradation pathway was proposed.
- 16 March 2016
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 23 (12) , 12362-12371
Gamma radiolytic decomposition of endosulfan in aerated solution: the role of carbonate radical
The present study elaborates the removal of endosulfan, an emerging water pollutant and potential carcinogenic, in aerated solution. The influence of Cl−, NO3 −, NO2 −, CO3 2−, HCO3 −, SO3 2−, and humic acid was assessed on the radiolytic degradation of endosulfan. A strong inhibition on the radiolytic degradation of endosulfan was observed in the presence of NO3 −, NO2 −, and SO3 2−. Instead, a slight increase in the removal efficiency of endosulfan was observed at high concentrations of CO3 2− and HCO3 −. The formation of CO3 •− in radiolytic degradation of endosulfan in the presence of CO3 2− and HCO3 − was demonstrated by adding SO3 2− that rapidly react with CO3 •−. The results indicate that CO3 •− formed from the reactions of CO3 2− and HCO3 − and commonly found in natural water can play an important role in the degradation of endosulfan and other sulfur containing electron-rich compounds. The study showed faster degradation of endosulfan at lower concentration compared to high concentration and removal was found to follow pseudo-first-order kinetic. Endosulfan ether was found as the main degradation product and degradation pathway was found to be initiated at the S=O bond of endosulfan. The efficiency of gamma irradiation in the removal of endosulfan was examined in terms of formation of short chain organic acids and chloride ion accumulation.
- 16 March 2016
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 23 (12) , 12362-12371
Gamma radiolytic decomposition of endosulfan in aerated solution: the role of carbonate radical
The present study elaborates the removal of endosulfan, an emerging water pollutant and potential carcinogenic, in aerated solution. The influence of Cl−, NO3 −, NO2 −, CO3 2−, HCO3 −, SO3 2−, and humic acid was assessed on the radiolytic degradation of endosulfan. A strong inhibition on the radiolytic degradation of endosulfan was observed in the presence of NO3 −, NO2 −, and SO3 2−. Instead, a slight increase in the removal efficiency of endosulfan was observed at high concentrations of CO3 2− and HCO3 −. The formation of CO3 •− in radiolytic degradation of endosulfan in the presence of CO3 2− and HCO3 − was demonstrated by adding SO3 2− that rapidly react with CO3 •−. The results indicate that CO3 •− formed from the reactions of CO3 2− and HCO3 − and commonly found in natural water can play an important role in the degradation of endosulfan and other sulfur containing electron-rich compounds. The study showed faster degradation of endosulfan at lower concentration compared to high concentration and removal was found to follow pseudo-first-order kinetic. Endosulfan ether was found as the main degradation product and degradation pathway was found to be initiated at the S=O bond of endosulfan. The efficiency of gamma irradiation in the removal of endosulfan was examined in terms of formation of short chain organic acids and chloride ion accumulation.
- 1 October 2015
- Published by Taylor & Francis in Environmental Technology
- Vol. 37 (5) , 590-602
Degradation of ciprofloxacin in water by advanced oxidation process: kinetics study, influencing parameters and degradation pathways
Gamma-radiation-induced degradation of ciprofloxacin (CIP) in aqueous solution and the factors affecting the degradation process have been investigated. The results showed that CIP (4.6 mg/L) was almost completely degraded at an absorbed dose of 870 Gy. The kinetic studies of aqueous solutions containing 4.6, 10, 15 and 17.9 mg/L indicated that the decomposition of CIP by gamma irradiation followed pseudo-first-order kinetics and the decay constant (k) decreased from 5.9 × 10−3 to 1.6 × 10−3 Gy−1 with an increase in CIP initial concentration from 4.6 to 17.9 mg/L. The effect of saturation of CIP solution with N2, N2O or air on radiation-induced degradation of CIP was also investigated. The effects of radical scavengers, such as t-BuOH and i-PrOH, showed the role of reactive radicals towards degradation of CIP in the order of . The apparent second-order rate constant of with CIP was calculated to be 2.64 × 109 M−1 s−1. The effects of solution pH as well as natural water contaminants, such as , , and , on CIP degradation by gamma-irradiation were also investigated. Major degradation products, including organic acids, were identified using UPLC-MS/MS and IC, and degradation pathways have been proposed.
- 1 October 2015
- Published by Taylor & Francis in Environmental Technology
- Vol. 37 (5) , 590-602
Degradation of ciprofloxacin in water by advanced oxidation process: kinetics study, influencing parameters and degradation pathways
Gamma-radiation-induced degradation of ciprofloxacin (CIP) in aqueous solution and the factors affecting the degradation process have been investigated. The results showed that CIP (4.6 mg/L) was almost completely degraded at an absorbed dose of 870 Gy. The kinetic studies of aqueous solutions containing 4.6, 10, 15 and 17.9 mg/L indicated that the decomposition of CIP by gamma irradiation followed pseudo-first-order kinetics and the decay constant (k) decreased from 5.9 × 10−3 to 1.6 × 10−3 Gy−1 with an increase in CIP initial concentration from 4.6 to 17.9 mg/L. The effect of saturation of CIP solution with N2, N2O or air on radiation-induced degradation of CIP was also investigated. The effects of radical scavengers, such as t-BuOH and i-PrOH, showed the role of reactive radicals towards degradation of CIP in the order of . The apparent second-order rate constant of with CIP was calculated to be 2.64 × 109 M−1 s−1. The effects of solution pH as well as natural water contaminants, such as , , and , on CIP degradation by gamma-irradiation were also investigated. Major degradation products, including organic acids, were identified using UPLC-MS/MS and IC, and degradation pathways have been proposed.
- 1 May 2015
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 288, 147-157
Role of eaq−, OH and H in radiolytic degradation of atrazine: A kinetic and mechanistic approach
- 1 May 2015
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 288, 147-157
Role of eaq−, OH and H in radiolytic degradation of atrazine: A kinetic and mechanistic approach