Yihao Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yihao Chen has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Xue Feng
Key Laboratory of Applied Mechanics, Department of Engineering Mechanics, Tsinghua University, Beijing, China
8 shared publications Bingwei Lu
Department of Engineering Mechanics Center for Flexible Electronics Technology Tsinghua University Hai Dian Beijing 100084 China
2 shared publicationsErwen Jia
Laboratory of Flexible Electronics Technology, Tsinghua University, Beijing, 100084, China
2 shared publicationsPing Zhang
Department of Cardiology, Beijing Tsinghua Changgung Hospital, Beijing, 102218, China
2 shared publicationsSiyuan Lu
Department of Engineering Mechanics, Tsinghua University, Beijing, China
2 shared publicationsXin Liu
Department of Engineering Mechanics Center for Flexible Electronics Technology Tsinghua University Hai Dian Beijing 100084 China
2 shared publications
Latest Publications
- Open Access
- 26 August 2026
- Published by Wiley in Advanced Robotics Research
Flexible Sensors for Robotics Tactile Perception: A Review
Touch links perception to control by turning contact into actionable force. It provides pressure and friction cues that help robots regulate grip and execute precise manipulation, especially in unstructured environments. As robots move into open, real‐world settings, rigid tactile sensors struggle with surface conformity. Flexible tactile sensors, with skin‐like softness and conformal contact, are emerging as a foundation for next‐generation robotic touch. This review provides a systematic survey of high‐impact advances in flexible tactile sensing for robotics, covering sensing mechanisms, structural design strategies, tactile decoding methods, and robotics‐oriented applications. We first analyze the characteristics, limitations, and robotic task suitability of different tactile sensing mechanisms, followed by a discussion of structural designs and integration approaches that enhance sensor performance. We then examine mechanics‐based reconstruction and intelligent decoding algorithms, including machine learning‐based tactile recognition and Transformer‐based tactile representation. Subsequently, we highlight frontier embodied intelligence applications enabled by flexible tactile sensing technologies. In addition, we identify four major research gaps and outline four priority directions for future development. This review aims to offer a robotics‐oriented, comprehensive technical reference for researchers in flexible tactile sensing and to promote substantive progress in robotic tactile perception.
- 26 August 2026
- Published by Wiley in Advanced Robotics Research
Open AccessFlexible Sensors for Robotics Tactile Perception: A Review
Touch links perception to control by turning contact into actionable force. It provides pressure and friction cues that help robots regulate grip and execute precise manipulation, especially in unstructured environments. As robots move into open, real‐world settings, rigid tactile sensors struggle with surface conformity. Flexible tactile sensors, with skin‐like softness and conformal contact, are emerging as a foundation for next‐generation robotic touch. This review provides a systematic survey of high‐impact advances in flexible tactile sensing for robotics, covering sensing mechanisms, structural design strategies, tactile decoding methods, and robotics‐oriented applications. We first analyze the characteristics, limitations, and robotic task suitability of different tactile sensing mechanisms, followed by a discussion of structural designs and integration approaches that enhance sensor performance. We then examine mechanics‐based reconstruction and intelligent decoding algorithms, including machine learning‐based tactile recognition and Transformer‐based tactile representation. Subsequently, we highlight frontier embodied intelligence applications enabled by flexible tactile sensing technologies. In addition, we identify four major research gaps and outline four priority directions for future development. This review aims to offer a robotics‐oriented, comprehensive technical reference for researchers in flexible tactile sensing and to promote substantive progress in robotic tactile perception.
- Open Access
- 9 February 2026
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 301, 118504
Finger pulp-inspired flexible pressure sensor array for gap balance monitoring during total knee arthroplasty
- 9 February 2026
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 301, 118504
Open AccessFinger pulp-inspired flexible pressure sensor array for gap balance monitoring during total knee arthroplasty
- Open Access
- 30 January 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (5) , eaeb7242
One-stop strabismus digital diagnosis via AI-integrated skin-like and wearable “Eyelectronics”
Strabismus, affecting ~4% of children, impairs vision and psychosocial health. However, clinical diagnosis requires multiple instruments and stepwise examinations of ocular alignment, extraocular muscle function, and deviation angle. It is limited by low diagnostic objectivity, poor pediatric compliance, and high cost. Here, we propose a strategy for one-stop strabismus digital diagnosis via artificial intelligence (AI)–integrated, skin-like, and wearable “Eyelectronics.” The ultralightweight, imperceptible eye-wearable system features an ultrathin (~60 micrometers in thickness), breathable, and multidirectional (0°/45°/90°) strain-sensing array conformally adapted to the sensitive eyelid. It enables wireless, mild-restricted measurement of eyelid deformation during eye movements. Through biomechanical modeling validated by ocular magnetic resonance imaging simulations, we establish a prior correlation between eyelid deformation and eye movements. The Eyelectronics, powered by our physiology knowledge-driven end-to-end AI algorithm, achieves simultaneous measurement of strabismus angle and identification of paretic muscle. It delivers a 96.6% four-direction classification accuracy and a 1.2° measurement accuracy in ocular motility examinations. Clinical benchmarking against the clinical standard (Hess screen test) confirmed diagnostic agreement (intraclass correlation = 0.978). This system bridges quantitative biomechanical sensing with digital diagnosis, promoting a paradigm for future strabismus treatment.
- 30 January 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (5) , eaeb7242
Open AccessOne-stop strabismus digital diagnosis via AI-integrated skin-like and wearable “Eyelectronics”
Strabismus, affecting ~4% of children, impairs vision and psychosocial health. However, clinical diagnosis requires multiple instruments and stepwise examinations of ocular alignment, extraocular muscle function, and deviation angle. It is limited by low diagnostic objectivity, poor pediatric compliance, and high cost. Here, we propose a strategy for one-stop strabismus digital diagnosis via artificial intelligence (AI)–integrated, skin-like, and wearable “Eyelectronics.” The ultralightweight, imperceptible eye-wearable system features an ultrathin (~60 micrometers in thickness), breathable, and multidirectional (0°/45°/90°) strain-sensing array conformally adapted to the sensitive eyelid. It enables wireless, mild-restricted measurement of eyelid deformation during eye movements. Through biomechanical modeling validated by ocular magnetic resonance imaging simulations, we establish a prior correlation between eyelid deformation and eye movements. The Eyelectronics, powered by our physiology knowledge-driven end-to-end AI algorithm, achieves simultaneous measurement of strabismus angle and identification of paretic muscle. It delivers a 96.6% four-direction classification accuracy and a 1.2° measurement accuracy in ocular motility examinations. Clinical benchmarking against the clinical standard (Hess screen test) confirmed diagnostic agreement (intraclass correlation = 0.978). This system bridges quantitative biomechanical sensing with digital diagnosis, promoting a paradigm for future strabismus treatment.
- Open Access
- 4 January 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (1) , 17
Glucose Sensor Design Based on Monte Carlo Simulation
Continuous glucose monitoring based on the minimally invasive implantation of glucose sensor is characterized by high accuracy and good stability. At present, glucose concentration monitoring based on fluorescent glucose capsule sensor is a new development trend. In this paper, we design a fluorescent glucose capsule sensor with a design optimization study. The motion trajectory of incident light in the fluorescent gel layer is simulated based on the Monte Carlo method, and the cloud maps of light intensity with the light intensity distribution at the light-receiving layer are plotted. Altering the density of fluorescent molecules, varying the thickness of tissue layers, and adjusting the angle of incidence deflection, the study investigates the influence of these parameter changes on the optimal position of reflected light at the bottom. Finally, the simulation results were utilized to design and fabricate a fluorescent glucose capsule sensor. Rabbit subcutaneous tissue glucose level tests and real-time glucose solution concentration monitoring experiments were performed. This work contributes to the real-time monitoring of glucose levels and opens up new avenues for research on fabricating glucose sensors.
- 4 January 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (1) , 17
Open AccessGlucose Sensor Design Based on Monte Carlo Simulation
Continuous glucose monitoring based on the minimally invasive implantation of glucose sensor is characterized by high accuracy and good stability. At present, glucose concentration monitoring based on fluorescent glucose capsule sensor is a new development trend. In this paper, we design a fluorescent glucose capsule sensor with a design optimization study. The motion trajectory of incident light in the fluorescent gel layer is simulated based on the Monte Carlo method, and the cloud maps of light intensity with the light intensity distribution at the light-receiving layer are plotted. Altering the density of fluorescent molecules, varying the thickness of tissue layers, and adjusting the angle of incidence deflection, the study investigates the influence of these parameter changes on the optimal position of reflected light at the bottom. Finally, the simulation results were utilized to design and fabricate a fluorescent glucose capsule sensor. Rabbit subcutaneous tissue glucose level tests and real-time glucose solution concentration monitoring experiments were performed. This work contributes to the real-time monitoring of glucose levels and opens up new avenues for research on fabricating glucose sensors.
- Open Access
- 13 December 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (50) , eadq5822
Bioinspired balloon catheter integrated with stretchable “flounder” electrodes under high voltage for uniform pulsed field ablation
Atrial fibrillation leads to severe diseases such as heart failure and strokes. While catheter ablation is prevalent for the treatment, existing techniques hardly can achieve both tissue selectivity and ablation uniformity. Here, we propose a bioinspired strategy for balloon-based pulsed field ablation (PFA) systems based on “flounder” electrodes. Inspired by a flounder skeleton and citrus peels, the microfabricated electrodes are ultrathin, stretchable, and have a scattered configuration, withstanding large balloon deformation (87% compression), high voltage (1200 volts), and owning exceptional tissue conformability (720° twists). Mechanical-electrical coupled stimulation optimizes balloon electrodes with hemispherical electric field uniformity. A water lily–inspired transfer printing method enables one-step integration of multielectrodes with the balloon. A comprehensive PFA system is complemented, achieving ablation depths of 3.8 millimeters (potato), 3.1 millimeters (rabbit), and 2.3 millimeters (swine) with good uniformity and electrophysiological isolation. These results shed light on the quantitative design of PFA systems, with high potential for more precise, safe, and effective catheter ablation therapies.
- 13 December 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (50) , eadq5822
Open AccessBioinspired balloon catheter integrated with stretchable “flounder” electrodes under high voltage for uniform pulsed field ablation
Atrial fibrillation leads to severe diseases such as heart failure and strokes. While catheter ablation is prevalent for the treatment, existing techniques hardly can achieve both tissue selectivity and ablation uniformity. Here, we propose a bioinspired strategy for balloon-based pulsed field ablation (PFA) systems based on “flounder” electrodes. Inspired by a flounder skeleton and citrus peels, the microfabricated electrodes are ultrathin, stretchable, and have a scattered configuration, withstanding large balloon deformation (87% compression), high voltage (1200 volts), and owning exceptional tissue conformability (720° twists). Mechanical-electrical coupled stimulation optimizes balloon electrodes with hemispherical electric field uniformity. A water lily–inspired transfer printing method enables one-step integration of multielectrodes with the balloon. A comprehensive PFA system is complemented, achieving ablation depths of 3.8 millimeters (potato), 3.1 millimeters (rabbit), and 2.3 millimeters (swine) with good uniformity and electrophysiological isolation. These results shed light on the quantitative design of PFA systems, with high potential for more precise, safe, and effective catheter ablation therapies.
- Open Access
- 12 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (5) , 1585-1595
Miniaturized Designs of Implantable and Wireless Hemodynamic Pressure Monitoring Capsules
Objective: Hemodynamic pressure (HP) monitoring is critical for managing cardiovascular diseases. Clinical Doppler echocardiography and invasive catheter monitoring cannot realize remote continuous monitoring in daily life. Current implantable wireless equipment depends on custom chips or indirect sensing, presenting challenges in cost-effective and precise applications. Here, we present systematic design strategies for implantable, wireless, and battery-free capsule-like HP monitoring under near and middle-distance circumstances. Methods: The systems were composed of completely non-customized devices, with extremely compact volumes (< 0.4 cm³). Near-distance monitoring utilized Near Field Communication with a piezoresistive sensor and foldable circuit designs. Middle-distance monitoring employed dual-winding antennas based on magnetic resonance (∼600 kHz) and Bluetooth. The power feedback circuit was optimized through human model electromagnetic simulations. Validation involved in vitro and in vivo experiments. Results: Near-distance system achieved 0.35 mmHg omnidirectional pressure accuracy under 5 mm tissue shielding. Middle-distance system attained the longest wireless power transfer distance (7.5 cm) via electromagnetic fields, supporting a capacitive sensor with 0.4 mmHg accuracy. In vitro tests in artificial tissue demonstrated for stable data/energy transfer, accommodating axial misalignments up to ±45°. In vivo experiments on the beagle demonstrated real-time, wireless monitoring of left-atrial pressure, whose rhythm synchronized with electrocardiograph recordings. The interatrial septum interventional installation was also validated. Conclusion: The wireless and implantable capsules enables near and middle-distance hemodynamic pressure monitoring, even in dynamic swinging intracardiac situations. and has been validated in animal experiments. Significance: The designs provide a universal method for in vivo fully-implantable pressure monitor development.
- 12 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (5) , 1585-1595
Open AccessMiniaturized Designs of Implantable and Wireless Hemodynamic Pressure Monitoring Capsules
Objective: Hemodynamic pressure (HP) monitoring is critical for managing cardiovascular diseases. Clinical Doppler echocardiography and invasive catheter monitoring cannot realize remote continuous monitoring in daily life. Current implantable wireless equipment depends on custom chips or indirect sensing, presenting challenges in cost-effective and precise applications. Here, we present systematic design strategies for implantable, wireless, and battery-free capsule-like HP monitoring under near and middle-distance circumstances. Methods: The systems were composed of completely non-customized devices, with extremely compact volumes (< 0.4 cm³). Near-distance monitoring utilized Near Field Communication with a piezoresistive sensor and foldable circuit designs. Middle-distance monitoring employed dual-winding antennas based on magnetic resonance (∼600 kHz) and Bluetooth. The power feedback circuit was optimized through human model electromagnetic simulations. Validation involved in vitro and in vivo experiments. Results: Near-distance system achieved 0.35 mmHg omnidirectional pressure accuracy under 5 mm tissue shielding. Middle-distance system attained the longest wireless power transfer distance (7.5 cm) via electromagnetic fields, supporting a capacitive sensor with 0.4 mmHg accuracy. In vitro tests in artificial tissue demonstrated for stable data/energy transfer, accommodating axial misalignments up to ±45°. In vivo experiments on the beagle demonstrated real-time, wireless monitoring of left-atrial pressure, whose rhythm synchronized with electrocardiograph recordings. The interatrial septum interventional installation was also validated. Conclusion: The wireless and implantable capsules enables near and middle-distance hemodynamic pressure monitoring, even in dynamic swinging intracardiac situations. and has been validated in animal experiments. Significance: The designs provide a universal method for in vivo fully-implantable pressure monitor development.
- 1 February 2022
- Published by Elsevier in Aquaculture
- Vol. 549, 737746
Combined effects of short term exposure to seawater acidification and microplastics on the early development of the oyster Crassostrea rivularis
- 1 February 2022
- Published by Elsevier in Aquaculture
- Vol. 549, 737746
Combined effects of short term exposure to seawater acidification and microplastics on the early development of the oyster Crassostrea rivularis
- Open Access
- 24 May 2021
- Published by Wiley in Advanced Materials Interfaces
- Vol. 8 (12) , 2100287
Interfacial Liquid Film Transfer Printing of Versatile Flexible Electronic Devices with High Yield Ratio
Emerging flexible electronic devices differ widely in terms of material, shape, scale, and structure. The conventional solid‐contact stamp transfer printing method easily causes cracks and interfacial delamination in large‐area, intricately‐patterned multilayered devices. Liquid film transfer printing (LTP) is presented as a strategy to obtain flexible devices with a high yield ratio regardless of the device material, scale, shape, and structure. In this technique, the liquid film is used to hydrolyze and break the chemical bonds between the film and silicon wafer substrate. Thus, there is less stress on the device during the transfer process. In addition, the buoyancy and surface tension of the liquid film help the flexible device to unroll itself on the liquid surface. In the experiments, flexible devices of different types and with extreme properties consistently achieved a transfer printing yield ratio of 98.57%. The sensitivity of temperature sensor change before and after LTP is less than 2%. The real‐time and visualized comparisons of the stress distribution and evolution during LTP and solid‐contact methods demonstrated that the LTP maximum strain is 70% smaller than the latter method. Thus, LTP has great potential for sophisticated and system‐level flexible device transfer printing and integration.
- 24 May 2021
- Published by Wiley in Advanced Materials Interfaces
- Vol. 8 (12) , 2100287
Open AccessInterfacial Liquid Film Transfer Printing of Versatile Flexible Electronic Devices with High Yield Ratio
Emerging flexible electronic devices differ widely in terms of material, shape, scale, and structure. The conventional solid‐contact stamp transfer printing method easily causes cracks and interfacial delamination in large‐area, intricately‐patterned multilayered devices. Liquid film transfer printing (LTP) is presented as a strategy to obtain flexible devices with a high yield ratio regardless of the device material, scale, shape, and structure. In this technique, the liquid film is used to hydrolyze and break the chemical bonds between the film and silicon wafer substrate. Thus, there is less stress on the device during the transfer process. In addition, the buoyancy and surface tension of the liquid film help the flexible device to unroll itself on the liquid surface. In the experiments, flexible devices of different types and with extreme properties consistently achieved a transfer printing yield ratio of 98.57%. The sensitivity of temperature sensor change before and after LTP is less than 2%. The real‐time and visualized comparisons of the stress distribution and evolution during LTP and solid‐contact methods demonstrated that the LTP maximum strain is 70% smaller than the latter method. Thus, LTP has great potential for sophisticated and system‐level flexible device transfer printing and integration.
- Top Cited Papers
- 27 June 2019
- Published by Wiley in Advanced Materials
- Vol. 32 (15) , e1902062
Flexible Hybrid Electronics for Digital Healthcare
Recent advances in material innovation and structural design provide routes to flexible hybrid electronics that can combine the high‐performance electrical properties of conventional wafer‐based electronics with the ability to be stretched, bent, and twisted to arbitrary shapes, revolutionizing the transformation of traditional healthcare to digital healthcare. Here, material innovation and structural design for the preparation of flexible hybrid electronics are reviewed, a brief chronology of these advances is given, and biomedical applications in bioelectrical monitoring and stimulation, optical monitoring and treatment, acoustic imitation and monitoring, bionic touch, and body‐fluid testing are described. In conclusion, some remarks on the challenges for future research of flexible hybrid electronics are presented.
- 27 June 2019
- Published by Wiley in Advanced Materials
- Vol. 32 (15) , e1902062
Top Cited PapersFlexible Hybrid Electronics for Digital Healthcare
Recent advances in material innovation and structural design provide routes to flexible hybrid electronics that can combine the high‐performance electrical properties of conventional wafer‐based electronics with the ability to be stretched, bent, and twisted to arbitrary shapes, revolutionizing the transformation of traditional healthcare to digital healthcare. Here, material innovation and structural design for the preparation of flexible hybrid electronics are reviewed, a brief chronology of these advances is given, and biomedical applications in bioelectrical monitoring and stimulation, optical monitoring and treatment, acoustic imitation and monitoring, bionic touch, and body‐fluid testing are described. In conclusion, some remarks on the challenges for future research of flexible hybrid electronics are presented.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 18.2.1-18.2.4
Skin-like nanostrucutred biosensor system for noninvasive blood glucose monitoring
We present a strategy to design and fabricate a skin-like nanostructured biosensor system (SNBS) that is only 3.8μm thick with high glucose measuring sensitivity. The SNBS is fabricated on the silicon wafer with MEMS fabrication process and then “liquid capillary transferred” off the wafer. The SNBS totally conforms to the skin morphology and fully measures the minimal volume of the analytes distributed among the skin ridges and valleys. The nanostructured electrode facilitates high-efficiency electrochemical deposition of the mechanically robust nano-transducer layer. The SNBS owns significant glucose sensitivity (130.4μA/mM) and good linearity (R 2 = 0.95) through large linear ranges. It has been successfully applied to non-invasive blood glucose (BG) monitoring in the in vivo clinical tests on human bodies. The measuring results are highly correlated to the glucometer and the venous blood testing results (>0.9). The SNBS can be used for the first time in clinical-grade fully non-invasive continuous glucose monitoring.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 18.2.1-18.2.4
Skin-like nanostrucutred biosensor system for noninvasive blood glucose monitoring
We present a strategy to design and fabricate a skin-like nanostructured biosensor system (SNBS) that is only 3.8μm thick with high glucose measuring sensitivity. The SNBS is fabricated on the silicon wafer with MEMS fabrication process and then “liquid capillary transferred” off the wafer. The SNBS totally conforms to the skin morphology and fully measures the minimal volume of the analytes distributed among the skin ridges and valleys. The nanostructured electrode facilitates high-efficiency electrochemical deposition of the mechanically robust nano-transducer layer. The SNBS owns significant glucose sensitivity (130.4μA/mM) and good linearity (R 2 = 0.95) through large linear ranges. It has been successfully applied to non-invasive blood glucose (BG) monitoring in the in vivo clinical tests on human bodies. The measuring results are highly correlated to the glucometer and the venous blood testing results (>0.9). The SNBS can be used for the first time in clinical-grade fully non-invasive continuous glucose monitoring.