KKKyung Hee Ko

Kyung Hee Ko

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kyung Hee Ko has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Additive predictive value of preoperative thyroid ultrasound parameters for postoperative hypothyroidism after hemithyroidectomy: a single-center retrospective study

    by Yeseul Kang, Seok-Jae Heo, Kyung Hee Ko, Juyeon Lee, Chorok Lee, Eun-Kyung Kim, Si Eun Lee

    Purpose: This study was performed to examine the association between preoperative thyroid ultrasound (US) features and the risk of developing hypothyroidism after hemithyroidectomy.Methods: Patients who underwent hemithyroidectomy between March 2020 and June 2023 were retrospectively included. Postoperative hypothyroidism was defined as a continued need for thyroxine 2 years after surgery. To assess US features suggestive of diffuse thyroid disease, two radiologists evaluated the echogenicity, echotexture, and vascularity of the thyroid parenchyma on preoperative thyroid US images. A US thyroid parenchymal score was defined by summing the scores for these parameters, and a weighted score was also developed using β-coefficients from a multivariable logistic regression model. Model performance was evaluated using the area under the receiver operating characteristic curve (AUC) and integrated discrimination improvement (IDI).Results: Overall, 398 patients were included, of whom 191 (47.9%) developed postoperative hypothyroidism. Preoperative thyroid-stimulating hormone (TSH), body surface area-adjusted remnant thyroid volume, histologic evidence of thyroiditis, and both unweighted and weighted US thyroid parenchymal scores were identified as significant predictors of postoperative hypothyroidism. The unweighted and weighted US scores were statistically significant predictors in the multivariable analysis (unweighted: odds ratio [OR], 1.36 [95% confidence interval (CI), 1.04 to 1.78]; weighted: OR, 3.05 [95% CI, 1.22 to 7.62]). Although adding US scores did not significantly improve the AUC, it led to significant improvements in IDI (P=0.04 and P=0.03, respectively). Conclusion: US assessment of the thyroid parenchyma served as an independent predictor of postoperative hypothyroidism and improved discrimination of predicted probabilities based on preoperative TSH.


  • Top Cited Papers

    Breast Cancers Detected and Missed by AI-CAD: Results from the AI-STREAM Trial

    by Yun-Woo Chang, Jung Kyu Ryu, Jin Kyung An, Nami Choi, Young Mi Park, Kyung Hee Ko

    Artificial intelligence–based computer-assisted diagnosis (AI-CAD) identified some breast cancers missed by radiologists but failed to detect others recalled by radiologists. Careful implementation and strategic interpretation of AI-CAD are essential in mammographic screening.


  • Open Access

    Corrigendum: Artificial Intelligence for Breast Cancer Screening in Mammography (AI-STREAM): A Prospective Multicenter Study Design in Korea Using AI-Based CADe/x

    by Yun-Woo Chang, Jin Kyung An, Nami Choi, Kyung Hee Ko, Ki Hwan Kim, Kyunghwa Han, Jung Kyu Ryu

    Chang YW, et al. J Breast Cancer. 2022 Apr;25(2):147-147. https://doi.org/10.4048/jbc.2022.25.e16


  • Open Access

    Artificial Intelligence for Breast Cancer Screening in Mammography (AI-STREAM): A Prospective Multicenter Study Design in Korea Using AI-Based CADe/x

    by Yun-Woo Chang, Jin Kyung An, Nami Choi, Kyung Hee Ko, Ki Hwan Kim, Kyunghwa Han, Jung Kyu Ryu

    Chang YW, et al. J Breast Cancer. 2022 Jan;25:e4. https://doi.org/10.4048/jbc.2022.25.e4


  • Assessing sizes of breast cancers that show non-mass enhancement on MRI based on inter-observer variability and comparison with pathology size

    by Jieun Koh, Ah Young Park, Kyung Hee Ko, Sewha Kim, Hae Kyoung Jung

    Background: Magnetic resonance imaging (MRI) is largely used for preoperative evaluation of breast cancer. Purpose: The aim of this study is to evaluate inter-observer variability for measuring the sizes of non-mass enhancement (NME) breast cancers on various sequences of MRI and to compare with pathology size. Material and Methods: From January 2013 to April 2017, 70 breast cancers in 70 women showed NME on preoperative MRI. Three observers retrospectively measured the cancers with the longest diameters on subtracted early dynamic contrast-enhanced (DCE) T1 (early T1), delayed DCE T1 (delayed T1), and maximum intensity projection (MIP) images; the measurements between observers were analyzed using the intraclass correlation coefficient (ICC). Pathology sizes were compared using ICCs and Bland–Altman plots, and concordance rates were calculated with MRI and pathology size differences of ≤0.5 cm. Results: The ICC for the three observers’ breast cancer size measurements was excellent (0.945) and that between MRI and pathology size was good to excellent in all observers (0.742–0.850). Compared with pathology size, the Bland–Altman plots revealed a positive trend of differences in all MRI measurements. Three observers overestimated nearly half of the measured breast cancers on all three MRI sequences; the overestimation rates were the highest on MIP for observers 1 and 3 (68.6% and 55.7%) and on delayed T1 for observer 2 (57.1%). Conclusion: The size assessments of NME breast cancer on MRI showed high correlation between observers and with pathology size. However, MRI measurements need a cautious approach because of their high overestimation rates. Measurements from early T1 images showed the highest concordance rate with pathology size.


  • Accuracy of Ultrasound for Preoperative Assessment of Tumor Size in Patients With Newly Diagnosed Breast Cancer: Is It Affected by the Background Parenchymal Echotexture?

    by Kyung Hee Ko, Eun Ju Son, In Wha Kim

    Objectives: To assess the impact of the background parenchymal echotexture on the accuracy of tumor size estimation using breast ultrasound (US).Methods: A total of 140 women with newly diagnosed invasive breast cancer from January 2014 to December 2015 were enrolled in this study. Two radiologists retrospectively reviewed US images in consensus for background parenchymal echotexture interpretation. The maximum tumor diameter from static images was recorded. Tumor size measurements were considered as having agreement with histologic results if they were within ±5 mm compared to the pathologic size. The relationship between the accuracy of tumor size measurement by the background parenchymal echotexture and clinicopathologic characteristics was evaluated.Results: Of these 140 patients, 77 (55.0%) showed a homogeneous background parenchymal echotexture, whereas 63 (45.0%) showed a heterogeneous echotexture. The mean tumor size was 1.9 cm (range, 0.5–4.9 cm). The overall accuracy of tumor size measurement was 76.4% (104 of 140). Tumors of women with a homogeneous background parenchymal echotexture were more accurately measured than those of women with a heterogeneous echotexture (87.0% versus 63.5%; P = .001). Tumors with a small size (P = .018) and ductal carcinoma in situ–negative (P = .031), human epidermal growth factor receptor 2 (HER2)‐negative (P = .053), and triple‐negative (P = .016) types were also more accurately measured. The independent factors associated with inaccurate tumor size measurement were a heterogeneous background parenchymal echotexture, a large tumor size, and the HER2‐enriched type (P < .05).Conclusions: The background parenchymal echotexture affected the accuracy of tumor size estimation using breast US. Invasive breast cancers with large (≥2 cm) tumors and the HER2‐enriched type showed significantly lower breast US accuracy compared to others.


  • Open Access

    Radiologic Features of Distant Filler Migration with Inflammatory Reaction Following Augmentation Mammoplasty Using Aquafilling® Filler

    by Kyung Hee Ko, Hae Kyoung Jung, Ah Young Park

    Introduction: Historically, breast augmentation with injectable materials has been performed for decades. However, in the long term all materials led to unfavorable results with serious side effects. Recently, we came across a patient who had performed a breast augmentation using a brand-new Aquafilling® filler. Some insist that it is a very safe filler providing satisfactory improvement in breast shape and volume without any inflammatory reaction or serious adverse effect. Case Presentation: Here, we present a 32-year-old woman who experienced severe complications 6 months after bilateral breast augmentation with Aquafilling® filler. The patient suffered from distant filler migration and inflammatory reaction extending from the left upper lateral abdominal wall to the vulva. Radiologic characteristics were very similar to those resulting from polyacrylamide gel (PAAG) mammoplasty. Results: The use of Aquafilling® filler for breast augmentation should be strongly restricted until long-term safety is proved and verified. Keywords: Augmentation Mammoplasty; Filler Migration; Hydrogel; Aquafilling®


  • Open Access

    Shear Wave Elastography

    by So Jung Kim, Kyung Hee Ko, Hae Kyoung Jung, Hyerin Kim

    The aim of this study is to evaluate the diagnostic value of shear wave elastography (SWE) added to conventional ultrasound (US) in the diagnosis of small (≤2 cm) breast cancer. Among 410 patients who underwent SWE before US-guided biopsy from June 2012 to June 2013, 171 patients (mean age: 45.17 ± 9.37 years) with 177 small (≤2 cm) breast lesions were enrolled in this study. Diagnostic performances of each quantitative SWE parameters were calculated by receiver operating characteristic (ROC) curves. Performances of conventional US and US combined to SWE was also compared. Histologic diagnosis was used as a reference standard. Of the 177 lesions, 22 lesions (12.4%) were malignant and 155 (87.6%) were benign. With respect to conventional US, when a cutoff point between category 3 and 4a was used, the Az value was 0.915 (100% sensitivity, 36.8% specificity, 18.3% positive predictive value (PPV), and 100% negative predictive value (NPV)). All average quantitative elastography values were significantly higher in malignant lesions compared to benign lesions (P = 0.001). The Emax value with a cutoff of 87.5 kPa had the highest Az value of 0.796 (68.2% sensitivity and 87.1% specificity, 42.9% PPV, and 95.1% NPV). Az value of combined data (0.861, 95% CI: 0.801, 0.909) was significantly lower than that of conventional US alone (P = 0.02). By using an Emax value for downgrading Breast Imaging Reporting and Data System (BI-RADS) category 4a lesions to category 3, 76/94 category 4a lesions (80.9%) were downgraded. After downgrading, 5 cancers were missed and the malignancy rate of category 3 lesions increased from 0% (0/55) to 3.8% (5/133) (P = 0.01). In conclusion, combined use of SWE and conventional US increased the specificity by reducing the number of unnecessary biopsies in differential diagnosis of small breast lesions. However, we propose that the application of conservative strategy for downgrading of soft category 4a lesions would be appropriate to minimize false-negative cases.