Carlos Vrancken
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Carlos Vrancken has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Gunnar Lovhoiden
Luminetx Corp., Memphis, Tennessee
6 shared publicationsHerbert D. Zeman
University of Tennessee Health Science Center Department of Biomedical Engineering 920 Madison Avenue, Room 1005 Memphis, Tennessee 38163
4 shared publicationsFlavio Henrique Duarte
Clinica Miyake, Sao Paulo, Brazil
2 shared publicationsHerbert David Zeman
Luminetx Corp., Memphis, Tennessee
2 shared publications- Philip Longhurst
Faculty of Engineering and Applied Sciences, Cranfield University, College Road, Cranfield, MK43 0AL, UK
2 shared publications Rodrigo Kikuchi
Clinica Miyake, Sao Paulo, Brazil
2 shared publications
Latest Publications
- Open Access
- 1 July 2019
- Published by Elsevier in Expert Systems with Applications
- Vol. 125, 268-280
Deep learning in material recovery: Development of method to create training database
- 1 July 2019
- Published by Elsevier in Expert Systems with Applications
- Vol. 125, 268-280
Open AccessDeep learning in material recovery: Development of method to create training database
- Open Access
- 1 March 2017
- Published by Elsevier in Waste Management
- Vol. 61, 40-57
Critical review of real-time methods for solid waste characterisation: Informing material recovery and fuel production
- 1 March 2017
- Published by Elsevier in Waste Management
- Vol. 61, 40-57
Open AccessCritical review of real-time methods for solid waste characterisation: Informing material recovery and fuel production
- Open Access
- 1 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Scaling Milton Keynes power requirements for electrical transportation
Milton Keynes is home to the UK's first installation of a wirelessly charged passenger bus route. This Inductive Power Transfer (IPT) system enables a fleet of 8 electric buses to service a demanding 15-mile urban route. Opportunistic wireless charging of the batteries during the layover time at the routes allows reducing the size of the batteries, consequently improving cost and performance characteristics of the bus. This paper aims to analyze the effects of electric buses on the electricity distribution grid. In particular, the paper analyses scalability of the IPT solution to all urban routes in Milton Keynes and compares peak power requirements generated at different points in the network with typical industrial and commercial (I&C) loads.
- 1 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Open AccessScaling Milton Keynes power requirements for electrical transportation
Milton Keynes is home to the UK's first installation of a wirelessly charged passenger bus route. This Inductive Power Transfer (IPT) system enables a fleet of 8 electric buses to service a demanding 15-mile urban route. Opportunistic wireless charging of the batteries during the layover time at the routes allows reducing the size of the batteries, consequently improving cost and performance characteristics of the bus. This paper aims to analyze the effects of electric buses on the electricity distribution grid. In particular, the paper analyses scalability of the IPT solution to all urban routes in Milton Keynes and compares peak power requirements generated at different points in the network with typical industrial and commercial (I&C) loads.
- 3 February 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 3, 1203-1206
The clinical evaluation of vein contrast enhancement
A vein contrast enhancer (VCE) has been constructed to make vein access easier by capturing an infrared image of veins, enhancing the contrast using software, and projecting the vein image back onto the skin. The VCE also uses software to align the projected image with the vein to 0.06 mm. Clinical evaluation of earlier monitor-based vein enhancement test systems has demonstrated the clinical utility of the infrared imaging technology used in the VCE.
- 3 February 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 3, 1203-1206
The clinical evaluation of vein contrast enhancement
A vein contrast enhancer (VCE) has been constructed to make vein access easier by capturing an infrared image of veins, enhancing the contrast using software, and projecting the vein image back onto the skin. The VCE also uses software to align the projected image with the vein to 0.06 mm. Clinical evaluation of earlier monitor-based vein enhancement test systems has demonstrated the clinical utility of the infrared imaging technology used in the VCE.
- 1 August 2006
- Published by Wolters Kluwer Health in Dermatologic Surgery
- Vol. 32 (8) , 1031-1038
Vein Imaging: A New Method of Near Infrared Imaging, Where a Processed Image Is Projected onto the Skin for the Enhancement of Vein Treatment
A new noninvasive vein imaging device initially developed for phlebotomy has been tested for the first time for vein treatment. This unique device captures a near infrared vein image, processes it, and projects it onto the skin using green light. To perform the first clinical tests of the device in phlebology. A pilot study on 23 subjects with varicose veins and telangiectasias was performed. The VeinViewer prototype (V-V-P; Luminetx Corp., Memphis, TN) was tested in five situations: diagnosing feeder veins with the V-V-P, comparison between the V-V-P and ultrasound, marking varicose veins with or without the device, phlebectomy using the V-V-P, and the use of laser and sclerotherapy guided by the V-V-P. One hundred percent of subjects had feeder veins identified by the V-V-P. The ultrasound machine detected fewer feeder veins than the V-V-P, and the device identified more veins than the naked eye in all subjects. The V-V-P could help in finding feeder veins during phlebectomy and in guiding laser and sclerotherapy treatments. The device could identify veins that were invisible to the naked eye and too shallow for ultrasound detection. The V-V-P may help find feeder veins and may also help various types of vein treatments.
- 1 August 2006
- Published by Wolters Kluwer Health in Dermatologic Surgery
- Vol. 32 (8) , 1031-1038
Vein Imaging: A New Method of Near Infrared Imaging, Where a Processed Image Is Projected onto the Skin for the Enhancement of Vein Treatment
A new noninvasive vein imaging device initially developed for phlebotomy has been tested for the first time for vein treatment. This unique device captures a near infrared vein image, processes it, and projects it onto the skin using green light. To perform the first clinical tests of the device in phlebology. A pilot study on 23 subjects with varicose veins and telangiectasias was performed. The VeinViewer prototype (V-V-P; Luminetx Corp., Memphis, TN) was tested in five situations: diagnosing feeder veins with the V-V-P, comparison between the V-V-P and ultrasound, marking varicose veins with or without the device, phlebectomy using the V-V-P, and the use of laser and sclerotherapy guided by the V-V-P. One hundred percent of subjects had feeder veins identified by the V-V-P. The ultrasound machine detected fewer feeder veins than the V-V-P, and the device identified more veins than the naked eye in all subjects. The V-V-P could help in finding feeder veins during phlebectomy and in guiding laser and sclerotherapy treatments. The device could identify veins that were invisible to the naked eye and too shallow for ultrasound detection. The V-V-P may help find feeder veins and may also help various types of vein treatments.
- 1 August 2005
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 44 (8) , 086401-086401-9
Prototype vein contrast enhancer
Two different prototype vein contrast enhancers (VCEs) have been designed and constructed. The VCE is an instrument that makes vein access easier by capturing an infrared image of peripheral veins, enhancing the vein contrast using software image processing, and projecting the enhanced vein image back onto the skin using a video projector. The prototypes use software alignment to achieve alignment accuracy between the captured infrared image and the projected visible image better than 0.06 mm.
- 1 August 2005
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 44 (8) , 086401-086401-9
Prototype vein contrast enhancer
Two different prototype vein contrast enhancers (VCEs) have been designed and constructed. The VCE is an instrument that makes vein access easier by capturing an infrared image of peripheral veins, enhancing the vein contrast using software image processing, and projecting the enhanced vein image back onto the skin using a video projector. The prototypes use software alignment to achieve alignment accuracy between the captured infrared image and the projected visible image better than 0.06 mm.
- 1 January 2005
- Published by Optica Publishing Group
- p. FTuBB3
Vein Contrast Enhancement for Medical Treatments
Invisible veins can be visualized by acquiring a vein image with near infrared light, and then projecting it back onto the skin with green light. The clinical use of the prototype VeinViewer will be discussed.
- 1 January 2005
- Published by Optica Publishing Group
- p. FTuBB3
Vein Contrast Enhancement for Medical Treatments
Invisible veins can be visualized by acquiring a vein image with near infrared light, and then projecting it back onto the skin with green light. The clinical use of the prototype VeinViewer will be discussed.
- 1 July 2004
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5318, 39-49
Prototype vein contrast enhancer
A proof-of-principle prototype Vein Contrast Enhancer (VCE) has been designed and constructed. The VCE is an instrument that makes vein access easier by capturing an infrared image of peripheral veins, enhancing the vein-contrast using software image processing, and projecting the enhanced vein-image back onto the skin using a modified commercial projector. The prototype uses software alignment to achieve alignment accuracy between the captured infrared image and the projected visible image of better than 0.06 mm. Figure 1 shows the prototype demonstrated in our laboratory.
- 1 July 2004
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5318, 39-49
Prototype vein contrast enhancer
A proof-of-principle prototype Vein Contrast Enhancer (VCE) has been designed and constructed. The VCE is an instrument that makes vein access easier by capturing an infrared image of peripheral veins, enhancing the vein-contrast using software image processing, and projecting the enhanced vein-image back onto the skin using a modified commercial projector. The prototype uses software alignment to achieve alignment accuracy between the captured infrared image and the projected visible image of better than 0.06 mm. Figure 1 shows the prototype demonstrated in our laboratory.
- 1 January 2004
- Published by Optica Publishing Group
- p. FTuL3
Subcutaneous vein contrast enhancement
A Vein Contrast Enhancer (VCE) has been constructed to make vein access easier by capturing an infrared image of veins, enhancing the contrast using software, and projecting the vein image back onto the skin. The VCE also uses software to align the projected image with the vein to 0.06 mm.
- 1 January 2004
- Published by Optica Publishing Group
- p. FTuL3
Subcutaneous vein contrast enhancement
A Vein Contrast Enhancer (VCE) has been constructed to make vein access easier by capturing an infrared image of veins, enhancing the contrast using software, and projecting the vein image back onto the skin. The VCE also uses software to align the projected image with the vein to 0.06 mm.
- 22 July 2003
- Published by SPIE-Intl Soc Optical Eng
- Vol. 4958, 189-200
Commercialization of vein contrast enhancement
An ongoing clinical study of an experimental infrared (IR) device, the Vein Contrast Enhancer (VCE) that visualizes surface veins for medical access, indicates that a commercial device with the performance of the existing VCE would have significant clinical utility for even a very skilled phlebotomist. A proof-of-principle prototype VCE device has now been designed and constructed that captures IR images of surface veins with a commercial CCD camera, transfers the images to a PC for real-time software image processing to enhance the vein contrast, and projects the enhanced images back onto the skin with a modified commercial LCD projector. The camera and projector are mounted on precision slides allowing for precise mechanical alignment of the two optical axes and for measuring the effects of axes misalignment. Precision alignment of the captured and projected images over the entire field-of-view is accomplished electronically by software adjustments of the translation, scaling, and rotation of the enhanced images before they are projected back onto the skin. This proof-of-principle prototype will be clinically tested and the experience gained will lead to the development of a commercial device, OnTarget!, that is compact, easy to use, and will visualize accessible veins in almost all subjects needing venipuncture.
- 22 July 2003
- Published by SPIE-Intl Soc Optical Eng
- Vol. 4958, 189-200
Commercialization of vein contrast enhancement
An ongoing clinical study of an experimental infrared (IR) device, the Vein Contrast Enhancer (VCE) that visualizes surface veins for medical access, indicates that a commercial device with the performance of the existing VCE would have significant clinical utility for even a very skilled phlebotomist. A proof-of-principle prototype VCE device has now been designed and constructed that captures IR images of surface veins with a commercial CCD camera, transfers the images to a PC for real-time software image processing to enhance the vein contrast, and projects the enhanced images back onto the skin with a modified commercial LCD projector. The camera and projector are mounted on precision slides allowing for precise mechanical alignment of the two optical axes and for measuring the effects of axes misalignment. Precision alignment of the captured and projected images over the entire field-of-view is accomplished electronically by software adjustments of the translation, scaling, and rotation of the enhanced images before they are projected back onto the skin. This proof-of-principle prototype will be clinically tested and the experience gained will lead to the development of a commercial device, OnTarget!, that is compact, easy to use, and will visualize accessible veins in almost all subjects needing venipuncture.