Sabrina Jimena Mora
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sabrina Jimena Mora has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
- Ana L. Moore
Arizona State University
6 shared publications - Erica Forzani
Arizona State University
6 shared publications - Edgardo Néstor Durantini
Instituto para el Desarrollo Agroindustrial y de la Salud (IDAS), Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Ruta Nacional 36 Km 601, Río Cuarto X5804BYA, Córdoba, Argentina
5 shared publications - Gary F. Moore
School of Molecular Sciences and the Biodesign Institute Center for Applied Structural Discovery (CASD), Arizona State University, Tempe, AZ 85287-1604, USA
5 shared publications - Brian L. Wadsworth
School of Molecular Sciences and the Biodesign Institute Center for Applied Structural Discovery (CASD), Arizona State University, Tempe, Arizona 85287-1604, United States
4 shared publications - Devens Gust
School of Molecular Sciences, Arizona State University, Tempe, Arizona 85287, United States
4 shared publications
Latest Publications
- Open Access
- 22 December 2023
- Published by MDPI AG in Biosensors
- Vol. 14 (1) , 4
A Novel Acetone Sensor for Body Fluids
Ketones are well-known biomarkers of fat oxidation produced in the liver as a result of lipolysis. These biomarkers include acetoacetic acid and β-hydroxybutyric acid in the blood/urine and acetone in our breath and skin. Monitoring ketone production in the body is essential for people who use caloric intake deficit to reduce body weight or use ketogenic diets for wellness or therapeutic treatments. Current methods to monitor ketones include urine dipsticks, capillary blood monitors, and breath analyzers. However, these existing methods have certain disadvantages that preclude them from being used more widely. In this work, we introduce a novel acetone sensor device that can detect acetone levels in breath and overcome the drawbacks of existing sensing approaches. The critical element of the device is a robust sensor with the capability to measure acetone using a complementary metal oxide semiconductor (CMOS) chip and convenient data analysis from a red, green, and blue deconvolution imaging approach. The acetone sensor device demonstrated sensitivity of detection in the micromolar-concentration range, selectivity for detection of acetone in breath, and a lifetime stability of at least one month. The sensor device utility was probed with real tests on breath samples using an established blood ketone reference method.
- 22 December 2023
- Published by MDPI AG in Biosensors
- Vol. 14 (1) , 4
Open AccessA Novel Acetone Sensor for Body Fluids
Ketones are well-known biomarkers of fat oxidation produced in the liver as a result of lipolysis. These biomarkers include acetoacetic acid and β-hydroxybutyric acid in the blood/urine and acetone in our breath and skin. Monitoring ketone production in the body is essential for people who use caloric intake deficit to reduce body weight or use ketogenic diets for wellness or therapeutic treatments. Current methods to monitor ketones include urine dipsticks, capillary blood monitors, and breath analyzers. However, these existing methods have certain disadvantages that preclude them from being used more widely. In this work, we introduce a novel acetone sensor device that can detect acetone levels in breath and overcome the drawbacks of existing sensing approaches. The critical element of the device is a robust sensor with the capability to measure acetone using a complementary metal oxide semiconductor (CMOS) chip and convenient data analysis from a red, green, and blue deconvolution imaging approach. The acetone sensor device demonstrated sensitivity of detection in the micromolar-concentration range, selectivity for detection of acetone in breath, and a lifetime stability of at least one month. The sensor device utility was probed with real tests on breath samples using an established blood ketone reference method.
- Open Access
A Smart System for the Contactless Measurement of Energy Expenditure
Energy Expenditure (EE) (kcal/day), a key element to guide obesity treatment, is measured from CO2 production, VCO2 (mL/min), and/or O2 consumption, VO2 (mL/min). Current technologies are limited due to the requirement of wearable facial accessories. A novel system, the Smart Pad, which measures EE via VCO2 from a room’s ambient CO2 concentration transients was evaluated. Resting EE (REE) and exercise VCO2 measurements were recorded using Smart Pad and a reference instrument to study measurement duration’s influence on accuracy. The Smart Pad displayed 90% accuracy (±1 SD) for 14–19 min of REE measurement and for 4.8–7.0 min of exercise, using known room’s air exchange rate. Additionally, the Smart Pad was validated measuring subjects with a wide range of body mass indexes (BMI = 18.8 to 31.4 kg/m2), successfully validating the system accuracy across REE’s measures of ~1200 to ~3000 kcal/day. Furthermore, high correlation between subjects’ VCO2 and λ for CO2 accumulation was observed (p < 0.00001, R = 0.785) in a 14.0 m3 sized room. This finding led to development of a new model for REE measurement from ambient CO2 without λ calibration using a reference instrument. The model correlated in nearly 100% agreement with reference instrument measures (y = 1.06x, R = 0.937) using an independent dataset (N = 56).
Open AccessA Smart System for the Contactless Measurement of Energy Expenditure
Energy Expenditure (EE) (kcal/day), a key element to guide obesity treatment, is measured from CO2 production, VCO2 (mL/min), and/or O2 consumption, VO2 (mL/min). Current technologies are limited due to the requirement of wearable facial accessories. A novel system, the Smart Pad, which measures EE via VCO2 from a room’s ambient CO2 concentration transients was evaluated. Resting EE (REE) and exercise VCO2 measurements were recorded using Smart Pad and a reference instrument to study measurement duration’s influence on accuracy. The Smart Pad displayed 90% accuracy (±1 SD) for 14–19 min of REE measurement and for 4.8–7.0 min of exercise, using known room’s air exchange rate. Additionally, the Smart Pad was validated measuring subjects with a wide range of body mass indexes (BMI = 18.8 to 31.4 kg/m2), successfully validating the system accuracy across REE’s measures of ~1200 to ~3000 kcal/day. Furthermore, high correlation between subjects’ VCO2 and λ for CO2 accumulation was observed (p < 0.00001, R = 0.785) in a 14.0 m3 sized room. This finding led to development of a new model for REE measurement from ambient CO2 without λ calibration using a reference instrument. The model correlated in nearly 100% agreement with reference instrument measures (y = 1.06x, R = 0.937) using an independent dataset (N = 56).
- 1 October 2021
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 345
Hydrogel-incorporated colorimetric sensors with high humidity tolerance for environmental gases sensing
- 1 October 2021
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 345
Hydrogel-incorporated colorimetric sensors with high humidity tolerance for environmental gases sensing
- 30 September 2021
- Published by Elsevier in Clinical Nutrition ESPEN
- Vol. 46, 361-366
Comparative study of a novel portable indirect calorimeter to a reference breath-by-breath instrument and its use in telemedicine settings
- 30 September 2021
- Published by Elsevier in Clinical Nutrition ESPEN
- Vol. 46, 361-366
Comparative study of a novel portable indirect calorimeter to a reference breath-by-breath instrument and its use in telemedicine settings
- Open Access
- 18 February 2021
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 143 (8) , 3104-3112
Electron–Nuclear Dynamics Accompanying Proton-Coupled Electron Transfer
Although photoinduced proton-coupled electron transfer (PCET) plays an essential role in photosynthesis, a full understanding of the mechanism is still lacking due to the complex nonequilibrium dynamics arising from the strongly coupled electronic and nuclear degrees of freedom. Here we report the photoinduced PCET dynamics of a biomimetic model system investigated by means of transient IR and two-dimensional electronic–vibrational (2DEV) spectroscopies, IR spectroelectrochemistry (IRSEC), and calculations utilizing long-range-corrected hybrid density functionals. This collective experimental and theoretical effort provides a nuanced picture of the complicated dynamics and synergistic motions involved in photoinduced PCET. In particular, the evolution of the 2DEV line shape, which is highly sensitive to the mixing of vibronic states, is interpreted by accurate computational modeling of the charge separated state and is shown to represent a gradual change in electron density distribution associated with a dihedral twist that occurs on a 120 fs time scale.
- 18 February 2021
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 143 (8) , 3104-3112
Open AccessElectron–Nuclear Dynamics Accompanying Proton-Coupled Electron Transfer
Although photoinduced proton-coupled electron transfer (PCET) plays an essential role in photosynthesis, a full understanding of the mechanism is still lacking due to the complex nonequilibrium dynamics arising from the strongly coupled electronic and nuclear degrees of freedom. Here we report the photoinduced PCET dynamics of a biomimetic model system investigated by means of transient IR and two-dimensional electronic–vibrational (2DEV) spectroscopies, IR spectroelectrochemistry (IRSEC), and calculations utilizing long-range-corrected hybrid density functionals. This collective experimental and theoretical effort provides a nuanced picture of the complicated dynamics and synergistic motions involved in photoinduced PCET. In particular, the evolution of the 2DEV line shape, which is highly sensitive to the mixing of vibronic states, is interpreted by accurate computational modeling of the charge separated state and is shown to represent a gradual change in electron density distribution associated with a dihedral twist that occurs on a 120 fs time scale.
- Open Access
Development of a new Aerosol Barrier Mask for mitigation of spread of SARS-CoV-2 and other infectious pathogens
The COVID-19 pandemic has caused huge impact on public health and significantly changed our lifestyle. This is due to the fast airborne oro-nasal transmission of SARS-CoV-2 from the infected individuals. The generation of liquid aerosolized particles occurs when the COVID-19 patients speak, sing, cough, sneeze, or simply breathe. We have developed a novel aerosol barrier mask (ABM) to mitigate the spread of SARS-CoV-2 and other infectious pathogens. This Aerosol Barrier Mask is designed for preventing SARS-CoV-2 transmission while transporting patients within hospital facilities. This mask can constrain aerosol and droplet particles and trap them in a biofilter, while the patient is normally breathing and administrated with medical oxygen. The system can be characterized as an oxygen delivery and mitigation mask which has no unfiltered exhaled air dispersion. The mask helps to prevent the spread of SARS-CoV-2, and potentially other infectious respiratory pathogens and protects everyone in general, especially healthcare professionals.
Open AccessDevelopment of a new Aerosol Barrier Mask for mitigation of spread of SARS-CoV-2 and other infectious pathogens
The COVID-19 pandemic has caused huge impact on public health and significantly changed our lifestyle. This is due to the fast airborne oro-nasal transmission of SARS-CoV-2 from the infected individuals. The generation of liquid aerosolized particles occurs when the COVID-19 patients speak, sing, cough, sneeze, or simply breathe. We have developed a novel aerosol barrier mask (ABM) to mitigate the spread of SARS-CoV-2 and other infectious pathogens. This Aerosol Barrier Mask is designed for preventing SARS-CoV-2 transmission while transporting patients within hospital facilities. This mask can constrain aerosol and droplet particles and trap them in a biofilter, while the patient is normally breathing and administrated with medical oxygen. The system can be characterized as an oxygen delivery and mitigation mask which has no unfiltered exhaled air dispersion. The mask helps to prevent the spread of SARS-CoV-2, and potentially other infectious respiratory pathogens and protects everyone in general, especially healthcare professionals.
- Open Access
An Unobstructive Sensing Method for Indoor Air Quality Optimization and Metabolic Assessment within Vehicles
This work investigates the use of an intelligent and unobstructive sensing technique for maintaining vehicle cabin’s indoor air quality while simultaneously assessing the driver metabolic rate. CO2 accumulation patterns are of great interest because CO2 can have negative cognitive effects at higher concentrations and also since CO2 accumulation rate can potentially be used to determine a person’s metabolic rate. The management of the vehicle’s ventilation system was controlled by periodically alternating the air recirculation mode within the cabin, which was actuated based on the CO2 levels inside the vehicle’s cabin. The CO2 accumulation periods were used to assess the driver’s metabolic rate, using a model that considered the vehicle’s air exchange rate. In the process of the method optimization, it was found that the vehicle’s air exchange rate (λ [h−1]) depends on the vehicle speeds, following the relationship: λ = 0.060 × (speed) − 0.88 when driving faster than 17 MPH. An accuracy level of 95% was found between the new method to assess the driver’s metabolic rate (1620 ± 140 kcal/day) and the reference method of indirect calorimetry (1550 ± 150 kcal/day) for a total of N = 16 metabolic assessments at various vehicle speeds. The new sensing method represents a novel approach for unobstructive assessment of driver metabolic rate while maintaining indoor air quality within the vehicle cabin.
Open AccessAn Unobstructive Sensing Method for Indoor Air Quality Optimization and Metabolic Assessment within Vehicles
This work investigates the use of an intelligent and unobstructive sensing technique for maintaining vehicle cabin’s indoor air quality while simultaneously assessing the driver metabolic rate. CO2 accumulation patterns are of great interest because CO2 can have negative cognitive effects at higher concentrations and also since CO2 accumulation rate can potentially be used to determine a person’s metabolic rate. The management of the vehicle’s ventilation system was controlled by periodically alternating the air recirculation mode within the cabin, which was actuated based on the CO2 levels inside the vehicle’s cabin. The CO2 accumulation periods were used to assess the driver’s metabolic rate, using a model that considered the vehicle’s air exchange rate. In the process of the method optimization, it was found that the vehicle’s air exchange rate (λ [h−1]) depends on the vehicle speeds, following the relationship: λ = 0.060 × (speed) − 0.88 when driving faster than 17 MPH. An accuracy level of 95% was found between the new method to assess the driver’s metabolic rate (1620 ± 140 kcal/day) and the reference method of indirect calorimetry (1550 ± 150 kcal/day) for a total of N = 16 metabolic assessments at various vehicle speeds. The new sensing method represents a novel approach for unobstructive assessment of driver metabolic rate while maintaining indoor air quality within the vehicle cabin.
- Open Access
Characterization of a novel, low-cost, scalable vaporized hydrogen peroxide system for sterilization of N95 respirators and other COVID-19 related personal protective equipment
Due to the virulence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the pathogen responsible for the respiratory disease termed COVID-19, there has been a significant increase in demand for surgical masks and N95 respirators in medical clinics as well as within communities operating during the COVID-19 epidemic. Thus, community members, business owners, and even medical personnel have resorted to alternative methods for sterilizing face coverings and N95 respirators for reuse. While significant work has shown that vaporized hydrogen peroxide (VHP) can be used to sterilize N95 respirators, the cost and installation time for these sterilization systems limit their accessibility. To this end, we have designed and constructed a novel, cost-effective, and scalable VHP system that can be used to sterilize N95 respirators and other face coverings for clinical and community applications. N95 respirators inoculated with P22 bacteriophage showed a greater than 6-log 10 reduction in viral load when sterilized in the VHP system for one 60-minute cycle. Further, N95 respirators treated with 20 cycles in this VHP system showed comparable filtration efficiency to untreated N95 respirators in a 50 to 200 nanometer particulate challenge filtration test. While a 23% average increase in water droplet roll-off time was observed for N95 respirators treated with 5 cycles in the sterilization, no breakdown in fluid resistance was detected. These data suggest that our VHP system is effective in sterilizing N95 respirators and other polypropylene masks for reuse. Relating to the present epidemic, deployment of this system reduces the risk of COVID-19 community transmission while conserving monetary resources otherwise spent on the continuous purchase of disposable N95 respirators and other face coverings. In summary, this novel, scientifically validated sterilization system can be easily built at a low cost and implemented in a wide range of settings.
Open AccessCharacterization of a novel, low-cost, scalable vaporized hydrogen peroxide system for sterilization of N95 respirators and other COVID-19 related personal protective equipment
Due to the virulence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the pathogen responsible for the respiratory disease termed COVID-19, there has been a significant increase in demand for surgical masks and N95 respirators in medical clinics as well as within communities operating during the COVID-19 epidemic. Thus, community members, business owners, and even medical personnel have resorted to alternative methods for sterilizing face coverings and N95 respirators for reuse. While significant work has shown that vaporized hydrogen peroxide (VHP) can be used to sterilize N95 respirators, the cost and installation time for these sterilization systems limit their accessibility. To this end, we have designed and constructed a novel, cost-effective, and scalable VHP system that can be used to sterilize N95 respirators and other face coverings for clinical and community applications. N95 respirators inoculated with P22 bacteriophage showed a greater than 6-log 10 reduction in viral load when sterilized in the VHP system for one 60-minute cycle. Further, N95 respirators treated with 20 cycles in this VHP system showed comparable filtration efficiency to untreated N95 respirators in a 50 to 200 nanometer particulate challenge filtration test. While a 23% average increase in water droplet roll-off time was observed for N95 respirators treated with 5 cycles in the sterilization, no breakdown in fluid resistance was detected. These data suggest that our VHP system is effective in sterilizing N95 respirators and other polypropylene masks for reuse. Relating to the present epidemic, deployment of this system reduces the risk of COVID-19 community transmission while conserving monetary resources otherwise spent on the continuous purchase of disposable N95 respirators and other face coverings. In summary, this novel, scientifically validated sterilization system can be easily built at a low cost and implemented in a wide range of settings.
- Open Access
- 20 March 2020
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 11 (15) , 3820-3828
Proton-coupled electron transfer across benzimidazole bridges in bioinspired proton wires
Designing molecular platforms for controlling proton and electron movement in artificial photosynthetic systems is crucial to efficient catalysis and solar energy conversion. The transfer of both protons and electrons during a reaction is known as proton-coupled electron transfer (PCET) and is used by nature in myriad ways to provide low overpotential pathways for redox reactions and redox leveling, as well as to generate bioenergetic proton currents. Herein, we describe theoretical and electrochemical studies of a series of bioinspired benzimidazole-phenol (BIP) derivatives and a series of dibenzimidazole-phenol (BI2P) analogs with each series bearing the same set of terminal proton-accepting (TPA) groups. The set of TPAs spans more than 6 pKa units. These compounds have been designed to explore the role of the bridging benzimidazole(s) in a one-electron oxidation process coupled to intramolecular proton translocation across either two (the BIP series) or three (the BI2P series) acid/base sites. These molecular constructs feature an electrochemically active phenol connected to the TPA group through a benzimidazole-based bridge, which together with the phenol and TPA group form a covalent framework supporting a Grotthuss-type hydrogen-bonded network. Infrared spectroelectrochemistry demonstrates that upon oxidation of the phenol, protons translocate across this well-defined hydrogen-bonded network to a TPA group. The experimental data show the benzimidazole bridges are non-innocent participants in the PCET process in that the addition of each benzimidazole unit lowers the redox potential of the phenoxyl radical/phenol couple by 60 mV, regardless of the nature of the TPA group. Using a series of hypothetical thermodynamic steps, density functional theory calculations correctly predicted the dependence of the redox potential of the phenoxyl radical/phenol couple on the nature of the final protonated species and provided insight into the thermodynamic role of dibenzimidazole units in the PCET process. This information is crucial for developing molecular “dry proton wires” with these moieties, which can transfer protons via a Grotthuss-type mechanism over long distances without the intervention of water molecules.
- 20 March 2020
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 11 (15) , 3820-3828
Open AccessProton-coupled electron transfer across benzimidazole bridges in bioinspired proton wires
Designing molecular platforms for controlling proton and electron movement in artificial photosynthetic systems is crucial to efficient catalysis and solar energy conversion. The transfer of both protons and electrons during a reaction is known as proton-coupled electron transfer (PCET) and is used by nature in myriad ways to provide low overpotential pathways for redox reactions and redox leveling, as well as to generate bioenergetic proton currents. Herein, we describe theoretical and electrochemical studies of a series of bioinspired benzimidazole-phenol (BIP) derivatives and a series of dibenzimidazole-phenol (BI2P) analogs with each series bearing the same set of terminal proton-accepting (TPA) groups. The set of TPAs spans more than 6 pKa units. These compounds have been designed to explore the role of the bridging benzimidazole(s) in a one-electron oxidation process coupled to intramolecular proton translocation across either two (the BIP series) or three (the BI2P series) acid/base sites. These molecular constructs feature an electrochemically active phenol connected to the TPA group through a benzimidazole-based bridge, which together with the phenol and TPA group form a covalent framework supporting a Grotthuss-type hydrogen-bonded network. Infrared spectroelectrochemistry demonstrates that upon oxidation of the phenol, protons translocate across this well-defined hydrogen-bonded network to a TPA group. The experimental data show the benzimidazole bridges are non-innocent participants in the PCET process in that the addition of each benzimidazole unit lowers the redox potential of the phenoxyl radical/phenol couple by 60 mV, regardless of the nature of the TPA group. Using a series of hypothetical thermodynamic steps, density functional theory calculations correctly predicted the dependence of the redox potential of the phenoxyl radical/phenol couple on the nature of the final protonated species and provided insight into the thermodynamic role of dibenzimidazole units in the PCET process. This information is crucial for developing molecular “dry proton wires” with these moieties, which can transfer protons via a Grotthuss-type mechanism over long distances without the intervention of water molecules.