PRPaulo Henrique Orlato Rossetti

Paulo Henrique Orlato Rossetti

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Paulo Henrique Orlato Rossetti has a total of 59 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • As conexões protéticas cônicas: quatro décadas de evolução biomecânica e clínica na Implantodontia

    by Valdir Antonio Muglia, Paulo Henrique Orlato Rossetti

    Objetivo: revisar criticamente a evolução histórica, biomecânica e clínica das conexões protéticas cônicas. Material e métodos: uma busca foi realizada nas bases de dados PubMed/MEDLINE, Scopus e Web of Science utilizando os seguintes descritores: “conical connection”, “Morse taper”, “implant-abutment interface”, “platform switching” e “marginal bone loss” entre 1985 e 2025. Resultados: os estudos selecionados demonstraram que as conexões cônicas apresentam melhor estabilidade mecânica, menor micromovimento, melhor manutenção do torque e menor perda óssea marginal quando comparadas às conexões não cônicas. Evidências histológicas, clínicas e biomecânicas mostraram comportamento peri-implantar mais favorável em implantes posicionados subcrestalmente, especialmente em sistemas do tipo morse taper, incluindo redução do microgap e do pumping effect, maior estabilidade protética e melhor preservação óssea peri-implantar. Além disso, a literatura demonstrou que fatores como conicidade da interface, profundidade de assentamento e retenção friccional influenciam diretamente o comportamento biomecânico e funcional das reabilitações em longo prazo. Estudos clínicos longitudinais relataram taxas de sobrevivência superiores a 98% associadas à mínima ou ausente perda óssea marginal peri-implantar, mesmo em implantes instalados em posição subcrestal. Conclusão: as conexões protéticas cônicas consolidaram-se como um dos principais avanços biomecânicos e biológicos da Implantodontia contemporânea. A estabilidade da interface implante-pilar, associada à redução do microgap, melhor selamento bacteriano, preservação óssea peri-implantar e previsibilidade clínica longitudinal, contribuiu para a ampla adoção desses sistemas nas reabilitações implantossuportadas modernas. Ao longo das últimas quatro décadas, as evidências biomecânicas, histológicas e clínicas passaram progressivamente a validar o papel das conexões cônicas na estabilidade funcional e biológica em longo prazo. Palavras-chave – Implantes dentários; Interface implante-pilar; Desenho de implantes dentários; Fenômenos biomecânicos; Perda óssea alveolar.

  • Open Access

    Periosteum-Derived Osteo-like Cells and Their Lyophilized Conditioned Medium Improve Bone Microarchitecture and Mineralized Tissue in Ovariectomized Rats: A Preliminary Proof-of-Concept Study

    by Raul Canal, José Ricardo Muniz Ferreira, Sergio Alexandre Gehrke, André Ferrão Vargas, João Pedro Grandini Zeferino, Daniel Navarro da Rocha, Fernanda Carla Bombaldi de Souza, Renata Francielle Bombaldi de Souza, Paulo Henrique Orlato Rossetti, Antonio Carlos Aloise, et al.

    Periosteum-derived osteo-like cells (PDOCs) and their lyophilized conditioned medium are promising tools for bone regeneration, but their therapeutic potential for osteoporosis remains unknown. This study evaluated the effects of PDOCs and their lyophilized conditioned medium on bone mineralization and microarchitecture in ovariectomized rats. Eighteen ovariectomized rats (six animals per group) received PBS (negative control group—NCG), PDOCs (periosteum osteo-like cell group—POCG), or a PDOC lyophilized conditioned medium (periosteum osteo-like lyophilized conditioned medium Group—POCM). All animals were euthanized after 42 days, and the femurs were submitted to microCT and histomorphometric analysis to determine: (1) thickness of the cortical bone; (2) number of trabeculae; (3) percentage of mineralized tissue; (4) percentage of collagen fibers; and (5) percentage of medullary spaces. The thickness of the cortical bone was statistically higher in POCG and POCM than in NCG animals (p < 0.05). The trabecular number was higher in POCG and POCM than in NCG rats (p < 0.05). The percentage of mineralized tissue was higher in POCG and POCM than in NCG animals (p < 0.05). No statistically significant difference was observed for collagen fibers or percentage of medullary spaces among groups. The use of PDOCs and their lyophilized conditioned medium improved cortical bone thickness, the number of trabeculae, and the level of mineralized tissue, suggesting that tissue engineering approaches with PDOCs and their lyophilized conditioned medium have potential use for the treatment of osteoporosis.

  • Open Access

    Periosteum-Derived Osteo-Like Cells and Their Lyophilized Conditioned Medium Improve Bone Microarchitecture and Mineralized Tissue in Ovariectomized Rats: A Proof-of-Concept Study

    by Raul Canal, José Ricardo Muniz Ferreira, Sérgio Alexandre Gehrke, André Ferrão Vargas, João Pedro Grandini Zeferino, Daniel Navarro da Rocha, Fernanda Carla Bombaldi de Souza, Renata Francielle Bombaldi de Souza, Paulo Henrique Orlato Rossetti, Antonio Carlos Aloise, et al.

    Periosteum-derived osteo-like cells (PDOCs) and their lyophilized conditioned medium are promising tools for bone regeneration, but their therapeutic potential for osteoporosis remains unknown. This study evaluated the effects of PDOCs and their lyophilized conditioned medium on bone mineralization and microarchitecture in ovariectomized rats. Eighteen ovariectomized rats (6 animals per group) received PBS (Negative Control Group–NCG); PDOCs (Periosteum Osteolike Cell Group - POCG), or PDOCs lyophilized conditioned medium (Periosteum Osteolike lyophilized conditioned medium Group - POCM). All animals were euthanized after 42 days, and the femurs submitted to microCT and histomorphometric analysis to determine: (1) thickness of the cortical bone; (2) number of trabeculae; (3) percentage of mineralized tissue; (4) percentage of collagen fibers; and (5) percentage of medullary spaces. The thickness of the cortical bone was statistically higher in POCG and POCM than in NCG animals (p<0.05). The trabecular number was higher in POCG and POCM than in NCG rats (p<0.05). The percentage of mineralized tissue was higher in POCG and POCM than in NCG animals (p<0.05), and no statistically significant difference was observed for collagen fibers and percentage of medullary spaces among groups. The use of PDOCs and their lyophilized conditioned medium improved cortical bone thickness, the number of trabeculae and the level of mineralized tissue, suggesting that tissue engineering approaches with PDOC and their lyophilized conditioned medium have potential use for the treatment of osteoporosis.

  • Zirconium Oxide Three-Unit Fixed Partial Denture Frameworks Supported by Dental Implants in Acceptable and Reduced Interocclusal Space Possibilities: Pilot In Vitro Fracture Strength and Fractographic Analyses

    by Sérgio Gehrke, Wellington Bonachela, Jéssica Moreno, Paulo Rossetti, Guillermo Cortellari, Berenice Dedavid, José Calvo-Guirado

    This study investigated the effect of fracture strength and fracture mode characteristics related to reduced interocclusal space on computer-aided design/computer-aided manufacturing (CAD/CAM). ZrO2 fixed partial denture (FPD) frameworks subjected to quasi-static loads. First, two dental implants (4 × 10 mm) were positioned simulating a three-unit FPD (second premolar and second molar abutments). The implants were distributed into two groups: control group (n = 10), positioned at the same level; and the test group (n = 10), where the interocclusal space corresponding to the second molar was reduced by 3 mm in relation to the second premolar to simulate a clinical situation. After FPD wax-up (25-mm long; connector height = 5 mm; connector width = 3 mm, proximal and lingual collar reinforcement), casting was made in a Co-Cr alloy to serve as a prototype. Upon scanning, screw-retained CAD/CAM ZrO2 FPDs were fabricated for each group. Then, FPDs were subjected to quasi-static axial loading until fracture in the mid-occlusal pontic area using a universal testing machine at the crosshead speed of 0.5 mm/min. Next, the samples were analyzed by scanning electronic microscopy (SEM) to describe the fracture characteristics. The mean fracture strength values for the control group (1,747.4 ± 122.3 N) and test group (1,817.7 ± 158.9 N) showed no significant difference (Student t test, P < .124). The SEM images of the fracture sites revealed two cleavage areas in the test group, providing representative sites with increased fracture energy storage in this group compared with the control group. Within the limitations of this study, the results showed that reduced interocclusal space and reduced length did not decrease the fracture strength of the ZrO2 FPD frameworks.


  • Stability and Crestal Bone Behavior Following Simultaneous Placement of Multiple Dental Implants (Two or More) with the Bone Splitting Technique: A Clinical and Radiographic Evaluation

    by Sergio Alexandre Gehrke, José Eduardo Maté Sánchez de Val, Maria Piedad Ramírez Fernández, Jamil Awad Shibli, Paulo Henrique Orlato Rossetti, José Luis Calvo Guirado

    Purpose: The present study aimed to measure the implant stability quotient (ISQ) values at three different time points after surgical procedures and crestal bone behavior in multiple implants (two or more) installed simultaneously with the bone splitting technique.Materials and Methods: For this study, 45 patients with different edentulous areas in the maxilla were selected, and a total of 114 dental implants were installed. Implant stability was measured by resonance frequency analysis immediately following implant placement to assess immediate stability (time 1) and stability at 90 days (time 2), and 150 days (time 3). Crestal bone height was measured in peri‐apical radiographs at 90 and 150 days after implantation in relation to each implant shoulder, given that the implants were installed at the level of the crestal bone.Results: Six implants were not osseointegrated. Overall, the means and standard deviations of the ISQ values were 60.3 ± 4.94 (95% confidence interval [CI], 44–69) at baseline, 66.6 ± 5.28 (95% CI, 49–75) at 90 days, and 72.1 ± 4.28 (95% CI, 59–79) at 150 days (p < 0.0001). The mean marginal bone loss of the implants was 1.11 ± 0.61 mm on the mesial side and 1.17 ± 0.61 mm on the distal side at time 2, and 1.73 ± 0.68 mm on the mesial side and 1.79 ± 0.70 mm on the distal side at time 3. A strong positive correlation between implant stability and bone loss was detected (p < 0.0001).Conclusions: Within the limits of this study, the bone splitting technique with simultaneous implant installation exhibited a good success rate with respect to the osseointegration index but requires attention with respect to crestal bone behavior.


  • Prevalence of Peri-implantitis in Medically Compromised Patients and Smokers: A Systematic Review

    by Alberto Turri, Paulo Rossetti, Luigi Canullo, Maria Grusovin, Christer Dahlin

    Alberto Turri, DDS/Paulo Henrique Orlato Rossetti, DDS/Luigi Canullo, DDS, PhD/ Maria Gabriella Grusovin, DDS/Christer Dahlin, DDS, PhD: Purpose: To verify whether the diversity of systemic medical conditions and smoking act as biologic associated factors for peri-implantitis. Materials and Methods: The PICO question was: ?In patients with osseointegrated dental implants, does the presence of smoking habits or a compromised medical status influence the occurrence of peri-implantitis compared with the presence of good general health?? Smoking and systemic conditions such as type 2 diabetes mellitus, cardiovascular diseases, rheumatoid arthritis, lung diseases, obesity, cancer, deep depression, and osteoporosis were screened. Selection criteria included at least 10 patients per condition, 1 year of follow-up after implant loading, and strict cutoff levels (probing pocket depth [PPD], bleeding on probing [BOP] and/or pus, marginal bone loss) to define peri-implantitis. Results: From the 1,136 records initially retrieved, 57 were selected after title and abstract analyses. However, only six papers were considered for qualitative evaluation. No randomized controlled clinical trial was found. Smoking was associated with peri-implantitis in only one out of four studies. Poorly controlled type 2 diabetes accentuated only PPD and radiographic marginal bone level prevalence rates in peri-implant patients (one study). Cardiovascular disease was considered a risk (one out of two studies). The chance of peri-implant patients harboring the Epstein-Barr virus was threefold in one report. No associations were found for rheumatoid arthritis. Conclusion: Data from existing studies point to smoking and diabetes as biologic associated factors for peri-implantitis. However, the body of evidence is still immature, and the specific contribution of general health problems to peri-implantitis requires additional robust epidemiologic and clinical investigations.


  • Microbiologic and Clinical Findings of Implants in Healthy Condition and with Peri-Implantitis

    by Luigi Canullo, David Peñarrocha-Oltra, Ugo Covani, Paulo Rossetti

    Luigi Canullo, DDS, PhD/David Pe?arrocha-Oltra, DDS, MSc, PhD/Ugo Covani, MD, DDS, PhD/Paulo Henrique Orlato Rossetti, DDS, MSc, PhD: Purpose: To compare implants in healthy conditions and implants with peri-implantitis with regard to their clinical parameters and the microbiologic composition at the peri-implant sulcus, inside the implant connection, and the gingival sulcus of neighboring teeth. Materials and Methods: A cross-sectional study was performed including consecutive patients with implants in healthy conditions and with peri-implantitis. Clinical parameters for which patients were screened included bleeding on probing, pocket depth, and plaque index at six sites. Samples for microbiologic analysis were obtained from three locations: the peri-implant sulcus, inside the implant connection, and the gingival sulcus of neighboring teeth. Quantitative real-time polymerase chain reaction (PCR) was carried out for total counts of 10 microorganisms: Aggregatibacter actinomycetemcomitans, Porphyromona gingivalis, Tanerella forsythia, Tanerella denticola, Prevotela intermedia, Peptostreptococcus micros, Fusobacterium nucleatum, Campylobacter rectus, Eikenella corrodens, and Candida albicans. The response variables were the percentage of positive sites and total bacterial counts. Results: One hundred twenty-two implants in 57 patients were analyzed in the healthy group and 113 implants in 53 patients in the peri-implantitis group. Differences between the groups were statistically significant for bruxism, probing pocket depth, bleeding on probing, and radiographic bone level. Orange complex species (P intermedia, P micros, F nucleatum) were the most prevalent in the three types of sites for both groups, and prevalence values were higher in the peri-implantitis group. Differences in prevalence between groups were more marked inside the connection than in the peri-implant sulcus. Absolute loads of most microbes and total bacterial counts were higher for the peri-implantitis group in the three locations. Again, differences were bigger inside the connection than at the peri-implant sulcus. Significant interactions were found for prevalence and absolute microbial loads between groups and locations, and for the interaction of group  location. Conclusion: Clinical and microbiologic differences were observed between healthy subjects and those with peri-implantitis. Microbiologic differences between groups were more marked inside the connection than in the peri-implant sulcus. The potential role of the implant connection as a microbial reservoir for peri-implant diseases and in the outcome of their treatment should be confirmed with further studies.


  • Stability of implants placed in fresh sockets versus healed alveolar sites: Early findings

    by Sergio Alexandre Gehrke, Ulisses Tavares da Silva Neto, Paulo Henrique Orlato Rossetti, Sidney Eiji Watinaga, Gabriela Giro, Jamil Awad Shibli

    Objectives: The present study measured implant stability quotient (ISQ) values at three different time points after surgical procedures to compare whether the stability values differed between implants placed in fresh extraction sockets versus healed alveolar sites.Materials and methods: To measure implant stability, resonance frequency analysis (RFA) was performed in 77 patients (53 women, 24 men) with a total of 120 dental implants. These implants were divided into two groups: Group 1 included 60 implants in healed alveolar sites (22 in the maxilla, 38 in the mandible), and Group 2 included 60 implants in fresh sockets (41 in the maxilla, 19 in the mandible). Implant stability was measured immediately at implant placement (baseline), 90, and 150 days later. Statistical analysis was made using a multivariate regression linear model at implant level (α = 0.05).Results: Overall, the means and standard deviations of the ISQ values were 62.7 ± 7.14 (95% confidence interval [CI], 39–88) at baseline, 70.0 ± 6.22 (95% CI, 46–88) at 90 days, and 73.4 ± 5.84 (95% CI, 58–88) at 150 days. In Group 1, the ISQs ranged between 64.3 ± 6.20 and 75.0 ± 5.69, while in Group 2, presented lower values that ranged between 61.2 ± 8.09 and 71.9 ± 5.99 (P = 0.002). Anatomic location and times periods were the only identified variables with an influence on ISQ values at implant level (P < 0.0001).Conclusions: The stabilities of the implants placed in the fresh sockets and in healed sites exhibited similar evolutions in ISQ values and thus osseointegration; however, the implants in the healed alveolar sites exhibited superior values at all time points.


  • Identification of Enterococcus Faecalis and Pseudomonas Aeruginosa on and in Implants in Individuals with Peri-implant Disease: A Cross-Sectional Study

    by Luigi Canullo, Paulo Rossetti, David Penarrocha

    Luigi Canullo, DDS, PhD/Paulo Henrique Orlato Rossetti, DDS, MSc, PhD/David Penarrocha, DDS, PhD: Purpose: To verify whether the parts of dental implants can be contaminated by opportunistic pathogens. Materials and Methods: In this cross-sectional study, 38 individuals (52 implants) were investigated. Samples for microbiologic analysis (for a total of 180 sites) were obtained from each individual, from three types of sites in the following order: (1) the peri-implant sulcus of each implant, (2) the gingival sulcus of adjacent teeth, and (3) inside the implant-abutment connection and the abutment of each implant. Swabs from the oral mucosa (cheeks, tongue, and pharynx) were also collected. Quantitative real-time polymerase chain reaction was carried out for total bacterial counts of Enterococcus faecalis and Pseudomonas aeruginosa. Two-way analysis of variance (sites, species) and Holm-Sidak tests were used for statistical analyses. Results: No opportunistic bacteria were found in the gingival sulcus specimens (38 sites). E faecalis was detected in the peri-implant sulcus (3 of 52 sites) and the inner connection/abutment portion (3 of 52 sites). P aeruginosa was identified only in the oral mucosa swabs (1 of 38 sites) and represented the highest bacterial number (3.5 ? 10⁶). Statistically significant differences were only found between species and in the peri-implant sulcus. Conclusion: Within the limitations of this study, significant differences in the presence and levels of nosocomial bacteria were detected in the peri-implant environment of diseased implants. From a clinical point of view, data from this study might suggest that, in patients affected by peri-implantitis, prostheses should be removed and the implant-abutment connection disinfected routinely, along with implant surface decontamination.


  • Systemic risk factors for peri-implant bone loss: a systematic review and meta-analysis

    by M. Clementini, P.H.O. Rossetti, D. Penarrocha, C. Micarelli, W.C. Bonachela, L. Canullo