Rosanne Zerafa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rosanne Zerafa has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Owen Falzon
Department of Podiatry, University of Malta, Msida MSD 2080, Malta
7 shared publications - Tracey Camilleri
Department of Systems and Control Engineering, Faculty of Engineering, University of Malta, Msida, Malta
7 shared publications - Kenneth P. Camilleri
Centre for Biomedical Cybernetics, University of Malta, Msida, Malta
5 shared publications Kenneth P. Camilleri
University of Malta
2 shared publications- Esther Monge-Pereira
Isaúde Research Group, Facultade de Fisioterapia, Universidade de Vigo, 36005 Pontevedra, Spain
1 shared publication - Irma Nayeli Angulo-Sherman
Vicerrectoría de Ciencias de la Salud
1 shared publication
Latest Publications
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2021, 959-962
SAT: A Switch-And-Train Framework for Real-Time Training of SSVEP-based BCIs
Reducing the training time for brain computer interfaces based on steady state evoked potentials, is essential to develop practical applications. We propose to eliminate the training required by the user before using the BCI with a switch-and-train (SAT) framework. Initially the BCI uses a training-free detection algorithm, and once sufficient training data is collected online, the BCI switches to a subject-specific training-based algorithm. Furthermore, the training-based algorithm is continuously re-trained in real-time. The performance of the SAT framework reached that of training-based algorithms for 8 out of 10 subjects after an average of 179 s ±33 s, an overall improvement over the training-free algorithm of 8.06%.
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2021, 959-962
SAT: A Switch-And-Train Framework for Real-Time Training of SSVEP-based BCIs
Reducing the training time for brain computer interfaces based on steady state evoked potentials, is essential to develop practical applications. We propose to eliminate the training required by the user before using the BCI with a switch-and-train (SAT) framework. Initially the BCI uses a training-free detection algorithm, and once sufficient training data is collected online, the BCI switches to a subject-specific training-based algorithm. Furthermore, the training-based algorithm is continuously re-trained in real-time. The performance of the SAT framework reached that of training-based algorithms for 8 out of 10 subjects after an average of 179 s ±33 s, an overall improvement over the training-free algorithm of 8.06%.
- 30 March 2021
- Published by Springer Nature
- p. 263-288
Idle State Detection with an Autoregressive Multiple Model Probabilistic Framework in SSVEP-Based Brain-Computer Interfaces
- 30 March 2021
- Published by Springer Nature
- p. 263-288
Idle State Detection with an Autoregressive Multiple Model Probabilistic Framework in SSVEP-Based Brain-Computer Interfaces
- 1 April 2019
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 5 (3) , 035031
The effect of distractors on SSVEP-based brain-computer interfaces
Objective. This study analyses the effect of distractors on steady-state visually evoked potentials (SSVEP) to establish how these nuisance signals, typically present in the real-world, would effect an SSVEP-based brain-computer interface (BCI). The distractors introduced to the SSVEP-based experiments are auditory, visual and movement distractors, specifically selected to reflect the use of various BCIs outside the laboratory. Approach. An assessment on the influence of these nuisance signals on SSVEP data as compared to SSVEP data with no distractors is presented. This is done by examining the frequency spectrum of the SSVEP responses followed by the implementation of feature extraction techniques, specifically canonical correlation analysis (CCA) and power spectral density analysis (PSDA), and a statistical analysis on the results obtained. As an added contribution, this study is designed to have each subject repeat the same experiments on different days such that the variation in performance with and without distractors may be investigated longitudinally. Main results. The results revealed that the spectra and the classification performance of the auditory distractors condition are comparable with the no distractors condition. On the other hand, there is a decrease in the signal-to-noise ratios (SNRs) of the visual and movement distractors conditions. This is reflected with a significant decrease in the SSVEP performance of 4.29% and 12.14% for the two distractor conditions respectively compared to the no distractors condition. A significant above-chance level SSVEP performance could still be obtained with all the distractor conditions. The longitudinal analysis revealed that the difference in performance between the SSVEP experimental conditions was consistent across sessions. Significance. This study provides a comparison on the performance of an SSVEP-based BCI with various external distractors. This analysis is necessary for the transition of BCI applications to be used every day in uncontrolled environments.
- 1 April 2019
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 5 (3) , 035031
The effect of distractors on SSVEP-based brain-computer interfaces
Objective. This study analyses the effect of distractors on steady-state visually evoked potentials (SSVEP) to establish how these nuisance signals, typically present in the real-world, would effect an SSVEP-based brain-computer interface (BCI). The distractors introduced to the SSVEP-based experiments are auditory, visual and movement distractors, specifically selected to reflect the use of various BCIs outside the laboratory. Approach. An assessment on the influence of these nuisance signals on SSVEP data as compared to SSVEP data with no distractors is presented. This is done by examining the frequency spectrum of the SSVEP responses followed by the implementation of feature extraction techniques, specifically canonical correlation analysis (CCA) and power spectral density analysis (PSDA), and a statistical analysis on the results obtained. As an added contribution, this study is designed to have each subject repeat the same experiments on different days such that the variation in performance with and without distractors may be investigated longitudinally. Main results. The results revealed that the spectra and the classification performance of the auditory distractors condition are comparable with the no distractors condition. On the other hand, there is a decrease in the signal-to-noise ratios (SNRs) of the visual and movement distractors conditions. This is reflected with a significant decrease in the SSVEP performance of 4.29% and 12.14% for the two distractor conditions respectively compared to the no distractors condition. A significant above-chance level SSVEP performance could still be obtained with all the distractor conditions. The longitudinal analysis revealed that the difference in performance between the SSVEP experimental conditions was consistent across sessions. Significance. This study provides a comparison on the performance of an SSVEP-based BCI with various external distractors. This analysis is necessary for the transition of BCI applications to be used every day in uncontrolled environments.
- 2 October 2018
- Published by Taylor & Francis in Brain-Computer Interfaces
- Vol. 5 (4) , 121-131
A comparison of a broad range of EEG acquisition devices – is there any difference for SSVEP BCIs?
This study compared the signal quality of six commercially available electroencephalography (EEG) signal acquisition systems in order to evaluate their application in a brain-computer interface (BCI). This is one of the largest studies in terms of subjects and systems focusing on comparing different EEG systems, involving the whole variety in terms of amplifier (research grade, consumer grade), electrode type (gel-based, saline-based, dry, active, passive), transmission technique (wired, wireless), and cost. We established an approach to evaluate the signal quality by means of a steady-state visually evoked potentials (SSVEP) experiment. This demonstrated that although high-end traditional EEG equipment may be the best choice for clinical applications, low-end wireless research grade gel-based EEG systems are comparable in terms of signal quality and therefore may be an effective alternative to BCIs developed for real environments. Other factors, such as end user and application, should also be considered when deciding which EEG system is best suited for a BCI.
- 2 October 2018
- Published by Taylor & Francis in Brain-Computer Interfaces
- Vol. 5 (4) , 121-131
A comparison of a broad range of EEG acquisition devices – is there any difference for SSVEP BCIs?
This study compared the signal quality of six commercially available electroencephalography (EEG) signal acquisition systems in order to evaluate their application in a brain-computer interface (BCI). This is one of the largest studies in terms of subjects and systems focusing on comparing different EEG systems, involving the whole variety in terms of amplifier (research grade, consumer grade), electrode type (gel-based, saline-based, dry, active, passive), transmission technique (wired, wireless), and cost. We established an approach to evaluate the signal quality by means of a steady-state visually evoked potentials (SSVEP) experiment. This demonstrated that although high-end traditional EEG equipment may be the best choice for clinical applications, low-end wireless research grade gel-based EEG systems are comparable in terms of signal quality and therefore may be an effective alternative to BCIs developed for real environments. Other factors, such as end user and application, should also be considered when deciding which EEG system is best suited for a BCI.
- 2 July 2018
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 15 (5) , 051001
To train or not to train? A survey on training of feature extraction methods for SSVEP-based BCIs
Objective . Despite the vast research aimed at improving the performance of steady-state visually evoked potential (SSVEP)-based brain–computer interfaces (BCIs), several limitations exist that restrict the use of such applications for long-term users in the real-world. One of the main challenges has been to reduce training time while maintaining good BCI performance. In view of this challenge, this survey identifies and compares the different training requirements of feature extraction methods for SSVEP-based BCIs. Approach . This paper reviews the various state-of-the-art SSVEP feature extraction methods that have been developed and are most widely used in the literature. Main results . The main contributions compared to existing reviews are the following: (i) a detailed summary, including a brief mathematical description of each feature extraction algorithm, providing a guide to the basic concepts of the state-of-the-art techniques for SSVEP-based BCIs found in literature; (ii) a categorisation of the training requirements of SSVEP-based methods into three categories, defined as training-free methods, subject-specific and subject-independent training methods; (iii) a comparative review of the training requirements of SSVEP feature extraction methods, providing a reference for future work on SSVEP-based BCIs. Significance . This review highlights the strengths and weaknesses of the three categories of SSVEP training methods. Training-free systems are more practical but their performance is limited due to inter-subject variability resulting from the complex EEG activity. Feature extraction methods that incorporate some training data address this issue and in fact have outperformed training-free methods: subject-specific BCIs are tuned to the individual yielding the best performance at the cost of long, tiring training sessions making these methods unsuitable for everyday use; subject-independent BCIs that make use of training data from various subjects offer a good trade-off between training effort and performance, making these BCIs better suited for practical use.
- 2 July 2018
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 15 (5) , 051001
To train or not to train? A survey on training of feature extraction methods for SSVEP-based BCIs
Objective . Despite the vast research aimed at improving the performance of steady-state visually evoked potential (SSVEP)-based brain–computer interfaces (BCIs), several limitations exist that restrict the use of such applications for long-term users in the real-world. One of the main challenges has been to reduce training time while maintaining good BCI performance. In view of this challenge, this survey identifies and compares the different training requirements of feature extraction methods for SSVEP-based BCIs. Approach . This paper reviews the various state-of-the-art SSVEP feature extraction methods that have been developed and are most widely used in the literature. Main results . The main contributions compared to existing reviews are the following: (i) a detailed summary, including a brief mathematical description of each feature extraction algorithm, providing a guide to the basic concepts of the state-of-the-art techniques for SSVEP-based BCIs found in literature; (ii) a categorisation of the training requirements of SSVEP-based methods into three categories, defined as training-free methods, subject-specific and subject-independent training methods; (iii) a comparative review of the training requirements of SSVEP feature extraction methods, providing a reference for future work on SSVEP-based BCIs. Significance . This review highlights the strengths and weaknesses of the three categories of SSVEP training methods. Training-free systems are more practical but their performance is limited due to inter-subject variability resulting from the complex EEG activity. Feature extraction methods that incorporate some training data address this issue and in fact have outperformed training-free methods: subject-specific BCIs are tuned to the individual yielding the best performance at the cost of long, tiring training sessions making these methods unsuitable for everyday use; subject-independent BCIs that make use of training data from various subjects offer a good trade-off between training effort and performance, making these BCIs better suited for practical use.
- 1 June 2017
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 3 (3) , 034001
Reducing the training time for the SSVEP-based music player application
This work focusses on reducing the training time required for a brain–computer interface (BCI) music player based on steady-state visually evoked potentials (SSVEPs). The music player is menu driven, featuring three different interfaces with up to six continuously flickering stimuli, similar to typical smart phone applications. This work investigates whether it is possible to go from a menu driven training approach to one which uses a single stimuli session only for training, or one which uses solely the data collected from the menu with the largest number of stimuli. Results show that the latter reduces the training time by 38.90%, specifically from 21 to 12.83 min without significant degradation in classification performance. Furthermore, promising results were also revealed when using a subject independent classifier which avoids individual training for new subjects by using training data from a database of other subjects. Although this work was targeted towards the brain controlled music player, the results are applicable to any SSVEP based BCI system having multiple interfaces with different number of flickering stimuli.
- 1 June 2017
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 3 (3) , 034001
Reducing the training time for the SSVEP-based music player application
This work focusses on reducing the training time required for a brain–computer interface (BCI) music player based on steady-state visually evoked potentials (SSVEPs). The music player is menu driven, featuring three different interfaces with up to six continuously flickering stimuli, similar to typical smart phone applications. This work investigates whether it is possible to go from a menu driven training approach to one which uses a single stimuli session only for training, or one which uses solely the data collected from the menu with the largest number of stimuli. Results show that the latter reduces the training time by 38.90%, specifically from 21 to 12.83 min without significant degradation in classification performance. Furthermore, promising results were also revealed when using a subject independent classifier which avoids individual training for new subjects by using training data from a database of other subjects. Although this work was targeted towards the brain controlled music player, the results are applicable to any SSVEP based BCI system having multiple interfaces with different number of flickering stimuli.
- 17 September 2016
- Published by Springer Nature
- p. 173-178
A Real-Time SSVEP-Based Brain-Computer Interface Music Player Application
- 17 September 2016
- Published by Springer Nature
- p. 173-178
A Real-Time SSVEP-Based Brain-Computer Interface Music Player Application
- 31 October 2015
- Published by Springer Nature
- p. 169-196
BCI Applied to Neurorehabilitation