SHStirling Howieson

Stirling Howieson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Stirling Howieson has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Improving indoor air quality using dynamic insulation and activated carbon in an air permeable ceiling

    by Mohd Firrdhaus Mohd Sahabuddin, Stirling Howieson

    Indoor air pollution has proven negative impacts on the urban population in many developing countries. In Kuala Lumpur, high-rise housing programmes are not addressing IAQ and thermal comfort. As household incomes rise, residents are resorting to retro-fitting wall mounted split, air conditioning units; a strategy that is neither cost nor carbon effective. This paper reports on the results of computer modelling in conjunction with scale model trials (1:5) of a ‘Dynamic-Hybrid Air Permeable Ceiling’ (DHAPC) designed to filter, cool and dehumidify, the incoming air mass. This filter membrane, when combined with activated charcoal, reduced carbon monoxide, sulphur dioxide, benzene and particulate levels by up to 90%. These techniques now require to be replicated at 1:1 scale; however, the initial data suggest that such an approach, could make a major contribution to improving indoor air quality and thermal comfort with a much reduced carbon penalty. Practical application: Air pollution is now being recognised as having major negative impacts on public health. The use of insulation, as a large area and volume air filter, would appear to be a highly effective technique to reduce particulate matter, and when combined with activated charcoal that absorbs/adsorbs toxic gasses, can significantly improve indoor air quality in cities across the world that are presently exceeding WHO air quality guidelines.


  • Displacing air conditioning in Kingdom of Saudi Arabia: An evaluation of ‘fabric first’ design integrated with hybrid night radiant and ground pipe cooling systems

    by Jamil Hijazi, Stirling Howieson

    This paper presents an investigation into the viability of ‘fabric first’ intelligent architectural design measures, in combination with a hybrid cooling system.The specific aim is to displace air conditioning (AC) and reduce carbon dioxide, while maintaining thermal comfort, in a typical housing block in KSA. The results of thermal modelling and prototype field trials suggest that passive design measures combined with night radiant cooling and supply ventilation via ground pipes, can negate the requirement for a standard AC system. Such a strategy may also have a remarkably short payback period when energy savings, in use, are set against the additional capital costs associated with improved building fabric performance. Practical application: This study suggests that a significant proportion of AC cooling energy can be displaced by improving building fabric performance in combination with supply ventilation via ground pipes. As radiometer readings fell as low as 2.8℃ when the night sky is clear, roof-mounted high emissivity hydronic radiant panels can also provide a significant opportunity for additional heat flushing. In hybrid combination, these strategies have the potential to lower the carbon footprint of a typical housing block in KSA by over 80% and these measures and strategies will be equally applicable and cost-effective in all geographic regions of the world where cooling loads represent the predominant domestic energy use.


  • Open Access

    The Great Scottish Housing Disaster: The Impacts of Feudalism, Modernism, Energy Efficiency and Vapour Barriers on Indoor Air Quality, Asthma and Public Health

    by Stirling Howieson

    This paper represents 30 years of research into the arena of housing and health. It brings together the conclusions of three books and the findings of multiple research papers undertaken by the author and published by medical, engineering and social policy journals. This work aims to highlight the links and connections between the diverse arenas of urban form, building design, energy efficiency, indoor air quality, respiratory medicine and immunology, all within the socio-economic framework of a small damp country on the fringe of northern Europe.


  • Open Access

    Occupant Interactions and Effectiveness of Natural Ventilation Strategies in Contemporary New Housing in Scotland, UK

    by Tim Sharpe, Paul Farren, Stirling Howieson, Paul Tuohy, Jonathan McQuillan

    The need to reduce carbon emissions and fuel poverty has led to increased building envelope air tightness, intended to reduce uncontrolled ventilation heat losses. Ventilation strategies in dwellings still allow the use of trickle ventilators in window frames for background ventilation. The extent to which this results in “healthy” Indoor Air Quality (IAQ) in recently constructed dwellings was a concern of regulators in Scotland. This paper describes research to explore this. First a review of literature was conducted, then data on occupant interactions with ventilation provisions (windows, doors, trickle vents) gathered through an interview-based survey of 200 recently constructed dwellings, and measurements made on a sample of 40 of these. The main measured parameter discussed here is CO2 concentration. It was concluded after the literature review that 1000 ppm absolute was a reasonable threshold to use for “adequate” ventilation. The occupant survey found that there was very little occupant interaction with the trickle ventilators e.g., in bedrooms 63% were always closed, 28% always open, and in only 9% of cases occupants intervened to make occasional adjustments. In the measured dwellings average bedroom CO2 levels of 1520 ppm during occupied (night time) hours were observed. Where windows were open the average bedroom CO2 levels were 972 ppm. With windows closed, the combination of “trickle ventilators open plus doors open” gave an average of 1021 ppm. “Trickle ventilators open” gave an average of 1571 ppm. All other combinations gave averages of 1550 to 2000 ppm. Ventilation rates and air change rates were estimated from measured CO2 levels, for all dwellings calculated ventilation rate was less than 8 L/s/p, in 42% of cases calculated air change rate was less than 0.5 ach. It was concluded that trickle ventilation as installed and used is ineffective in meeting desired ventilation rates, evidenced by high CO2 levels reported across the sampled dwellings. Potential implications of the results are discussed.


  • Decreased FEV1% in asthmatic adults in Scottish homes with high Environmental Relative Moldiness Index values

    by C. McSharry, S. Vesper, L. Wymer, S. Howieson, R. Chaudhuri, G. R. Wright, N. C. Thomson

    Summary: Background: Exposures to indoor biological contaminants have been implicated in asthma's aetiology but their effect on lung function is not well quantified.Objective: The aim of this cross‐sectional study of non‐smoking, asthmatic adults in Scotland was to determine the correlation between the results from a standard spirometry test, forced expiratory volume in one‐second percent (FEV1%), and quantitative estimates of some biological exposures.Methods: A population (n = 55) of non‐smoking, adult asthmatics in Scotland was included in this study and each completed a questionnaire that allowed the determination of the Asthma Control Questionnaire scores (ACQ) and St. George's Respiratory Questionnaire scores (SGRQ), as well as corticosteroid use. Spirometry testing was completed and the pre‐bronchodilator FEV1% value calculated. At about the same time, floor dust samples were collected in the living room and in the bedroom. These dust samples were analysed for mould contamination, as described by the Environmental Relative Moldiness Index (ERMI) values and by (1, 3)‐β‐D‐glucan concentrations, for endotoxin, and for dust mite, cat, and dog allergen concentrations. The asthmatics' FEV1% values were tested for correlation (Pearson) to questionnaire‐based estimates of health. Also, each biological exposure was tested for correlation (Pearson) to the FEV1% values.Results: FEV1% results were correlated with ACQ scores (ρ −0.586, P < 0.001), SGRQ scores (ρ −0.313, P = 0.020), and weakly with corticosteroid use (ρ −0.221, P = 0.105). The ERMI values in the homes (average 5.3) were significantly correlated with FEV1% values (ρ −0.378, P = 0.004). There was no correlation between FEV1% and concentrations of endotoxin, (1, 3)‐β‐D‐glucan, or any of the allergens.Conclusion and clinical relevance: Although these results do not prove that mould exposures caused the deficit in lung function observed in this study, it might be advisable for asthmatics to avoid high ERMI environments.


  • Are our homes making us ill? The impact of energy efficiency on indoor air quality

    by Stirling Howieson

    The World Health Organization estimates that over 100,000 people die every year from conditions resulting from occupational exposure to asbestos. Similar to this, a significant proportion of asthma and related ill health is driven by poor indoor air quality. Stirling Howieson, Senior Lecturer in Architecture at the University of Strathclyde, takes a look at the increasing prevalence of asthma and asks the question, are our homes making us ill


  • Effect of improved home ventilation on asthma control and house dust mite allergen levels

    by G. R. Wright, S. Howieson, C. McSharry, A. D. McMahon, R. Chaudhuri, J. Thompson, I. Donnelly, R. G. Brooks, A. Lawson, L. Jolly, et al.

    Background:  The warm, humid environment in modern homes favours the dust mite population, but the effect of improved home ventilation on asthma control has not been established. We tested the hypothesis that a domestic mechanical heat recovery ventilation system (MHRV), in addition to allergen avoidance measures, can improve asthma control by attenuating re‐colonization rates.Methods:  We conducted a randomized double‐blind placebo‐controlled parallel group trial of the installation of MHRV activated in half the homes of 120 adults with asthma, allergic to Dermatophagoides pteronyssinus. All homes had carpets steam cleaned and new bedding and mattress covers at baseline. The primary outcome was morning peak expiratory flow (PEF) at 12 months.Results:  At 12 months, the primary end‐point; change in mean morning PEF as compared with baseline, did not differ between the MHRV group and the control group (mean difference 13.5 l/min, 95% CI: −2.6 to 29.8, P = 0.10). However, a secondary end‐point; evening mean PEF, was significantly improved in the MHRV group (mean difference 24.5 l/min, 95% CI: 8.9–40.1, P = 0.002). Indoor relative humidity was reduced in MHRV homes, but there was no difference between the groups in Der p 1 levels, compared with baseline.Conclusions:  The addition of MHRV to house dust mite eradication strategies did not achieve a reduction in mite allergen levels, but did improve evening PEF.


  • Housing and Asthma

    by Stirling Howieson

    Asthma is on the rise in a number of countries, in this volume Howieson asks what role the built environment has to play and what the construction industry can do to either slow the increase or reverse the trend. Based on the findings of a six-year research project, this book considers all aspects of housing to develop new strategies for dealing with the asthma pandemic in Britain and beyond. With the focus on the design and use pattern of our dwellings, the book looks at tackling the problems inherent in existing housing as well as forging guiding principles for the design of new dwellings, together with a financial assessment of the proposals.


  • Multiple deprivation and excess winter deaths in Scotland

    by Stirling G Howieson, M Hogan

    The recent publication of the Scottish Index of Multiple Deprivation (SIMD) has allowed some tentative statistical correlations to be undertaken to assess the impact poverty may have on mortality and morbidity. During the period 1989 to 2001, Scotland registered around 51,600 excess winter deaths (EWDs). An EWD is taken as the additional deaths during December to March than occurred in the preceding and subsequent four-month periods. Almost all of these EWDs were in the population aged over 65. This represents 50 more deaths per day in January than in July. The SIMD measured five criteria by region: income; employment; health and disability; education, skills and training; and geographical access to services. Glasgow was the most deprived region with an SIMD score of 46.88 and East Dunbartonshire, the least deprived region, with a score of 9.07. For the over 65s, the chance of becoming an EWD in Glasgow is one in 36, rising to one in 68 for North Ayrshire. The SIMD is positively correlated with EWD by region (0.35 at the 5% confidence level). This correlation appears to go against the influence of climatic variations, house type, energy efficiency and access to the gas network which favours urban areas. Although some of the additional winter deaths have been ascribed to outdoor cold exposure - exacerbated by inappropriate clothing or culturally determined behaviour - the majority of EWDs are premature and essentially preventable if the elderly can be kept warm in their homes during the winter months.


  • Domestic ventilation rates, indoor humidity and dust mite allergens: are our homes causing the asthma pandemic?

    by S G Howieson, A Lawson, C McSharry, G Morris, E McKenzie, J Jackson

    This paper is concerned with historical changes in domestic ventilation rates, relative humidity and the associated risk of house dust mite colonization. A controlled trial evaluated allergen and water vapour control measures on the level of house dust mite (HDM) Der p1 allergen and indoor humidity, concurrently with changes in lung function in 54 subjects who completed the protocol. Mechanical heat recovery ventilation units significantly reduced moisture content in the active group, while HDM allergen reservoirs in carpets and beds were reduced by circa 96%. Self reported health status confirmed a significant clinical improvement in the active group. The study can form the basis for assessing minimum winter ventilation rates that can suppress RH below the critical ambient equilibrium humidity of 60% and thus inhibit dust mite colonization and activity in temperate and maritime in‘ uenced climatic regions.