Kris Wolfs
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kris Wolfs has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Erwin Adams
Department of Pharmaceutical and Pharmacological Sciences, Pharmaceutical Analysis, KU Leuven, 3000 Leuven, Belgium
24 shared publications - Ann Van Schepdael
Pharmaceutical Analysis, Department of Pharmaceutical and Pharmacological Sciences, KU Leuven—University of Leuven, Herestraat 49, O&N2, PB 923, 3000 Leuven, Belgium
21 shared publications Jos Hoogmartens
Faculteit Farmaceutische Wetenschappen KU Leuven Belgium
10 shared publicationsNiels van Boxtel
Pharmaceutical Analysis Group, Department of Pharmaceutical and Pharmacological Sciences, University of Leuven, Leuven, Belgium
4 shared publicationsWard D’autry
Laboratory for Pharmaceutical Analysis, Faculty of Pharmaceutical Sciences, Katholieke Universiteit Leuven, Leuven, Belgium
3 shared publicationsAdissu Alemayehu Asfaw
KU Leuven - University of Leuven, Department of Pharmaceutical and Pharmacological Sciences, Pharmaceutical Analysis, Herestraat 49, O&N2, PB 923, 3000, Leuven, Belgium
2 shared publications
Latest Publications
- 20 June 2026
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1418
An automated dual-mode platform for affinity-based screening of natural products using a pressure-driven strategy
- 20 June 2026
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1418
An automated dual-mode platform for affinity-based screening of natural products using a pressure-driven strategy
- 18 August 2025
- Published by Elsevier in Journal of Chromatography A
- Vol. 1760, 466300
Influence of the transfer segment between thermal desorber and gas chromatograph applied to essential oil samples
- 18 August 2025
- Published by Elsevier in Journal of Chromatography A
- Vol. 1760, 466300
Influence of the transfer segment between thermal desorber and gas chromatograph applied to essential oil samples
- 24 February 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1719, 464770
Impact of diluents on the calibration of direct dynamic thermal desorption prior to gas chromatography
- 24 February 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1719, 464770
Impact of diluents on the calibration of direct dynamic thermal desorption prior to gas chromatography
- Open Access
Determination of Inorganic Ions in Parenteral Nutrition Solutions by Ion Chromatography
A new, simple and sensitive ion chromatography (IC) method for the determination of sodium, potassium, magnesium, calcium and chloride in a parenteral nutrition (PN) solution was developed and validated. Before sample analysis, a sample pretreatment by calcination was applied which could totally remove interference from other constituents of the PN solution. Methanesulfonic acid (MSA) and sodium hydroxide were used as the mobile phase for the determination of cations and anions, respectively. The calibration curves showed good correlation between analyte peak area and concentration (r2 > 0.999). Detection limits ranged from 0.0001 to 0.02 mg/L and quantification limits from 0.0002 to 0.06 mg/L. Relative standard deviation (RSD) values for repeatability and inter-day precision did not exceed 1.0% and the recoveries for all analytes were between 99.1–101.1%. The robustness was verified by using an experimental design.
Open AccessDetermination of Inorganic Ions in Parenteral Nutrition Solutions by Ion Chromatography
A new, simple and sensitive ion chromatography (IC) method for the determination of sodium, potassium, magnesium, calcium and chloride in a parenteral nutrition (PN) solution was developed and validated. Before sample analysis, a sample pretreatment by calcination was applied which could totally remove interference from other constituents of the PN solution. Methanesulfonic acid (MSA) and sodium hydroxide were used as the mobile phase for the determination of cations and anions, respectively. The calibration curves showed good correlation between analyte peak area and concentration (r2 > 0.999). Detection limits ranged from 0.0001 to 0.02 mg/L and quantification limits from 0.0002 to 0.06 mg/L. Relative standard deviation (RSD) values for repeatability and inter-day precision did not exceed 1.0% and the recoveries for all analytes were between 99.1–101.1%. The robustness was verified by using an experimental design.
- 1 May 2018
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 153, 193-198
Determination of residual dimethylsulphoxide in drug loaded gelatin using thermal desorber – gas chromatography
- 1 May 2018
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 153, 193-198
Determination of residual dimethylsulphoxide in drug loaded gelatin using thermal desorber – gas chromatography
- 31 August 2017
- Published by Wiley in Journal of Separation Science
- Vol. 40 (20) , 4004-4011
Comprehensive headspace gas chromatographic analysis of denaturants in denatured ethanol
To discourage consumption, ethanol is often denatured using both volatile (e.g., methyl ethyl ketone and isopropanol) and nonvolatile (e.g., denatonium benzoate) chemical substances. As a result, the analysis of denatured ethanol samples is usually performed by multiple techniques such as gas chromatography for the volatile denaturants and liquid chromatography for the nonvolatile ones. However, the need for multiple techniques increases the cost of analysis and forms a severe obstruction for on‐site product control. Using the full evaporation technique combined with gas chromatography and flame ionization detection, only one analytical methodology has to be used here to determine both volatile and nonvolatile denaturants in denatured ethanol. Denatonium benzoate is determined as benzyl chloride following an in‐vial reaction. Compared to conventional techniques, the novel method performs equally well, but it is simpler to apply. At the same time, drawbacks of alternative methods are circumvented such as equilibration issues and alterations to the stationary phase when using liquid chromatography with ion pairing agents or matrix effects when applying static headspace gas chromatography. The developed method showed good linearity, repeatability, and recovery toward all analytes and was applied to the analysis of commercial denatured ethanol for disinfection and ethanol‐based windscreen washer fluids.
- 31 August 2017
- Published by Wiley in Journal of Separation Science
- Vol. 40 (20) , 4004-4011
Comprehensive headspace gas chromatographic analysis of denaturants in denatured ethanol
To discourage consumption, ethanol is often denatured using both volatile (e.g., methyl ethyl ketone and isopropanol) and nonvolatile (e.g., denatonium benzoate) chemical substances. As a result, the analysis of denatured ethanol samples is usually performed by multiple techniques such as gas chromatography for the volatile denaturants and liquid chromatography for the nonvolatile ones. However, the need for multiple techniques increases the cost of analysis and forms a severe obstruction for on‐site product control. Using the full evaporation technique combined with gas chromatography and flame ionization detection, only one analytical methodology has to be used here to determine both volatile and nonvolatile denaturants in denatured ethanol. Denatonium benzoate is determined as benzyl chloride following an in‐vial reaction. Compared to conventional techniques, the novel method performs equally well, but it is simpler to apply. At the same time, drawbacks of alternative methods are circumvented such as equilibration issues and alterations to the stationary phase when using liquid chromatography with ion pairing agents or matrix effects when applying static headspace gas chromatography. The developed method showed good linearity, repeatability, and recovery toward all analytes and was applied to the analysis of commercial denatured ethanol for disinfection and ethanol‐based windscreen washer fluids.
- 11 August 2017
- Published by American Chemical Society (ACS) in Molecular Pharmaceutics
- Vol. 14 (12) , 4202-4208
Gastric and Duodenal Ethanol Concentrations after Intake of Alcoholic Beverages in Postprandial Conditions
This study determined intraluminal ethanol concentrations (stomach and duodenum) in fed healthy volunteers after the consumption of common alcoholic beverages (beer, wine, and whisky). The results of this study were compared with a previous study in fasted volunteers. Five healthy volunteers were recruited in a crossover study. The fed state was simulated by ingestion of 250 mL of Nutridrink Compact Neutral. Volunteers subsequently consumed two standard units of beer (Stella Artois, 500 mL, 5.2% ethanol), wine (Blanc du Blanc, 200 mL, 11% ethanol), or whisky (Gallantry Whisky, 80 mL, 40% ethanol). Gastric and duodenal fluids were aspirated through two catheters over time and analyzed for ethanol content by head space gas chromatography. The capability of ethanol to permeate gastric and duodenal rat mucosa was examined in an Ussing chambers setup. A similar average gastric Cmax was observed in the beer and the wine conditions: 3.3% and 3.7% ethanol, respectively. The gastric Cmax in the whisky condition amounted to 8.5% ethanol. Lower ethanol concentrations were observed in the duodenum compared to the stomach. The duodenal Cmax was similar in all three conditions: 1.3%, 1.2%, and 1.6% ethanol for beer, wine, and whisky, respectively. Compared to the fasted state (reported in a previous study), higher gastric ethanol concentrations were observed during a longer time period. In the beer and wine conditions, similar concentrations were observed in the intestine regardless of the prandial state. After intake of whisky, however, the ethanol concentration was lower in the fed intestine. Alcohol was observed to permeate both gastric and duodenal rat mucosa. Higher intragastric ethanol concentrations were maintained for a longer period of time in fed compared to fasted state conditions. However, the observed concentration profiles were not in line with current FDA guidelines for alcohol resistance testing of formulations, stating that in vitro tests should investigate the impact of up to 40% ethanol for 2 h. The presented intraluminal ethanol concentrations may serve as reference data for the further development of relevant in vitro models to assess ethanol effects on formulation performance.
- 11 August 2017
- Published by American Chemical Society (ACS) in Molecular Pharmaceutics
- Vol. 14 (12) , 4202-4208
Gastric and Duodenal Ethanol Concentrations after Intake of Alcoholic Beverages in Postprandial Conditions
This study determined intraluminal ethanol concentrations (stomach and duodenum) in fed healthy volunteers after the consumption of common alcoholic beverages (beer, wine, and whisky). The results of this study were compared with a previous study in fasted volunteers. Five healthy volunteers were recruited in a crossover study. The fed state was simulated by ingestion of 250 mL of Nutridrink Compact Neutral. Volunteers subsequently consumed two standard units of beer (Stella Artois, 500 mL, 5.2% ethanol), wine (Blanc du Blanc, 200 mL, 11% ethanol), or whisky (Gallantry Whisky, 80 mL, 40% ethanol). Gastric and duodenal fluids were aspirated through two catheters over time and analyzed for ethanol content by head space gas chromatography. The capability of ethanol to permeate gastric and duodenal rat mucosa was examined in an Ussing chambers setup. A similar average gastric Cmax was observed in the beer and the wine conditions: 3.3% and 3.7% ethanol, respectively. The gastric Cmax in the whisky condition amounted to 8.5% ethanol. Lower ethanol concentrations were observed in the duodenum compared to the stomach. The duodenal Cmax was similar in all three conditions: 1.3%, 1.2%, and 1.6% ethanol for beer, wine, and whisky, respectively. Compared to the fasted state (reported in a previous study), higher gastric ethanol concentrations were observed during a longer time period. In the beer and wine conditions, similar concentrations were observed in the intestine regardless of the prandial state. After intake of whisky, however, the ethanol concentration was lower in the fed intestine. Alcohol was observed to permeate both gastric and duodenal rat mucosa. Higher intragastric ethanol concentrations were maintained for a longer period of time in fed compared to fasted state conditions. However, the observed concentration profiles were not in line with current FDA guidelines for alcohol resistance testing of formulations, stating that in vitro tests should investigate the impact of up to 40% ethanol for 2 h. The presented intraluminal ethanol concentrations may serve as reference data for the further development of relevant in vitro models to assess ethanol effects on formulation performance.
- 1 June 2017
- Published by Elsevier in Journal of Chromatography A
- Vol. 1500, 160-166
Thermal desorption—Gas chromatographic methodology for the determination of residual solvents in mesoporous silica
- 1 June 2017
- Published by Elsevier in Journal of Chromatography A
- Vol. 1500, 160-166
Thermal desorption—Gas chromatographic methodology for the determination of residual solvents in mesoporous silica
- 1 December 2016
- Published by Elsevier in Journal of Chromatography A
- Vol. 1476, 105-113
Headspace gas chromatography based methodology for the analysis of aromatic substituted quaternary ammonium salts
- 1 December 2016
- Published by Elsevier in Journal of Chromatography A
- Vol. 1476, 105-113
Headspace gas chromatography based methodology for the analysis of aromatic substituted quaternary ammonium salts