Ofer Barnea
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ofer Barnea has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Oded Luria
Tel Aviv University
4 shared publicationsGabriel Gillon
Department of Urology, Rabin Medical Center—Beilinson Campus and The Sackler School of Medicine, Tel Aviv University, Israel
3 shared publicationsAbraham Golan
Edith Wolfson Medical Center
2 shared publications- Amit Gefen
School of Biomedical Engineering, Faculty of Engineering Tel Aviv University Tel Aviv Israel
2 shared publications - Ani Amar
Bar-Ilan University
2 shared publications Jacob Bar
Edith Wolfson Medical Center
2 shared publications
Latest Publications
- Open Access
- 17 January 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (1) , e0191238
Mechano-electric feedback effects in a three-dimensional (3D) model of the contracting cardiac ventricle
Mechano-electric feedback affects the electrophysiological and mechanical function of the heart and the cellular, tissue, and organ properties. To determine the main factors that contribute to this effect, this study investigated the changes in the action potential characteristics of the ventricle during contraction. A model of stretch-activated channels was incorporated into a three-dimensional multiscale model of the contracting ventricle to assess the effect of different preload lengths on the electrophysiological behavior. The model describes the initiation and propagation of the electrical impulse, as well as the passive (stretch) and active (contraction) changes in the cardiac mechanics. Simulations were performed to quantify the relationship between the cellular activation and recovery patterns as well as the action potential durations at different preload lengths in normal and heart failure pathological conditions. The simulation results showed that heart failure significantly affected the excitation propagation parameters compared to normal condition. The results showed that the mechano-electrical feedback effects appear to be most important in failing hearts with low ejection fraction.
- 17 January 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (1) , e0191238
Open AccessMechano-electric feedback effects in a three-dimensional (3D) model of the contracting cardiac ventricle
Mechano-electric feedback affects the electrophysiological and mechanical function of the heart and the cellular, tissue, and organ properties. To determine the main factors that contribute to this effect, this study investigated the changes in the action potential characteristics of the ventricle during contraction. A model of stretch-activated channels was incorporated into a three-dimensional multiscale model of the contracting ventricle to assess the effect of different preload lengths on the electrophysiological behavior. The model describes the initiation and propagation of the electrical impulse, as well as the passive (stretch) and active (contraction) changes in the cardiac mechanics. Simulations were performed to quantify the relationship between the cellular activation and recovery patterns as well as the action potential durations at different preload lengths in normal and heart failure pathological conditions. The simulation results showed that heart failure significantly affected the excitation propagation parameters compared to normal condition. The results showed that the mechano-electrical feedback effects appear to be most important in failing hearts with low ejection fraction.
- 5 October 2015
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 6 (4) , 401-411
Multiscale Interactions in a 3D Model of the Contracting Ventricle
A biophysical detailed multiscale model of the myocardium is presented. The model was used to study the contribution of interrelated cellular mechanisms to global myocardial function. The multiscale model integrates cellular electrophysiology, excitation propagation dynamics and force development models into a geometrical fiber based model of the ventricle. The description of the cellular electrophysiology in this study was based on the Ten Tusscher–Noble–Noble–Panfilov heterogeneous model for human ventricular myocytes. A four-state model of the sarcomeric control of contraction developed by Negroni and Lascano was employed to model the intracellular mechanism of force generation. The propagation of electrical excitation was described by a reaction–diffusion equation. The 3D geometrical model of the ventricle, based on single fiber contraction was used as a platform for the evaluation of proposed models. The model represents the myocardium as an anatomically oriented array of contracting fibers with individual fiber parameters such as size, spatial location, orientation and mechanical properties. Moreover, the contracting ventricle model interacts with intraventricular blood elements linking the contractile elements to the heart’s preload and afterload, thereby producing the corresponding pressure–volume loop. The results show that the multiscale ventricle model is capable of simulating mechanical contraction, pressure generation and load interactions as well as demonstrating the individual contribution of each ion current.
- 5 October 2015
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 6 (4) , 401-411
Multiscale Interactions in a 3D Model of the Contracting Ventricle
A biophysical detailed multiscale model of the myocardium is presented. The model was used to study the contribution of interrelated cellular mechanisms to global myocardial function. The multiscale model integrates cellular electrophysiology, excitation propagation dynamics and force development models into a geometrical fiber based model of the ventricle. The description of the cellular electrophysiology in this study was based on the Ten Tusscher–Noble–Noble–Panfilov heterogeneous model for human ventricular myocytes. A four-state model of the sarcomeric control of contraction developed by Negroni and Lascano was employed to model the intracellular mechanism of force generation. The propagation of electrical excitation was described by a reaction–diffusion equation. The 3D geometrical model of the ventricle, based on single fiber contraction was used as a platform for the evaluation of proposed models. The model represents the myocardium as an anatomically oriented array of contracting fibers with individual fiber parameters such as size, spatial location, orientation and mechanical properties. Moreover, the contracting ventricle model interacts with intraventricular blood elements linking the contractile elements to the heart’s preload and afterload, thereby producing the corresponding pressure–volume loop. The results show that the multiscale ventricle model is capable of simulating mechanical contraction, pressure generation and load interactions as well as demonstrating the individual contribution of each ion current.
- 8 November 2013
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 5 (1) , 82-95
Optimization of Oxygen Delivery in Fluid Resuscitation for Hemorrhagic Shock: A Computer Simulation Study
- 8 November 2013
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 5 (1) , 82-95
Optimization of Oxygen Delivery in Fluid Resuscitation for Hemorrhagic Shock: A Computer Simulation Study
- 31 May 2013
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 5 (2) , 202-216
Inverse Solution of the Fetal-Circulation Model Based on Ultrasound Doppler Measurements
- 31 May 2013
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 5 (2) , 202-216
Inverse Solution of the Fetal-Circulation Model Based on Ultrasound Doppler Measurements
- 1 November 2011
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 14 (11) , 957-968
A computational method for developing hierarchical large deformation viscoelastic models of the contracting heart
In this study, a new computational method for modelling the contracting heart is described. Using this method, the cardiac wall is constructed from basic, repeating contractile units that represent individual myocardial units and collagen, each with its own set of parameters, including orientation, passive and active behaviour and stimulation propagation. The method allows individual control of each structural unit (e.g. at the level of a single myocardial unit). Feasibility of modelling dynamic heart contraction using this method is demonstrated using 2D cross-sections and simplified 3D geometries. Effects of non-contractile scar and myopathic tissue were also tested in these geometrical configurations. Results from the 2D and 3D simulations were, overall, in agreement with well-established physiological data. The present method holds promise for modelling complex heart pathologies, abnormal mechanical properties (e.g. myocardial infarcts) and electrical conduction properties (branch blocks), and their spatial distributions across the myocardial tissues.
- 1 November 2011
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 14 (11) , 957-968
A computational method for developing hierarchical large deformation viscoelastic models of the contracting heart
In this study, a new computational method for modelling the contracting heart is described. Using this method, the cardiac wall is constructed from basic, repeating contractile units that represent individual myocardial units and collagen, each with its own set of parameters, including orientation, passive and active behaviour and stimulation propagation. The method allows individual control of each structural unit (e.g. at the level of a single myocardial unit). Feasibility of modelling dynamic heart contraction using this method is demonstrated using 2D cross-sections and simplified 3D geometries. Effects of non-contractile scar and myopathic tissue were also tested in these geometrical configurations. Results from the 2D and 3D simulations were, overall, in agreement with well-established physiological data. The present method holds promise for modelling complex heart pathologies, abnormal mechanical properties (e.g. myocardial infarcts) and electrical conduction properties (branch blocks), and their spatial distributions across the myocardial tissues.
- 25 August 2011
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 34 (3) , 364-369
The role of blood flow distribution in the regulation of cerebral oxygen availability in fetal growth restriction
Fetal growth restriction (FGR) elicits hemodynamic compensatory mechanisms in the fetal circulation. These mechanisms are complex and their effect on the cerebral oxygen availability is not fully understood. To quantify the contribution of each compensatory mechanism to the fetal cerebral oxygen availability, a mathematical model of the fetal circulation was developed. The model was based on cardiac-output distribution in the fetal circulation. The compensatory mechanisms of FGR were simulated and their effects on cerebral oxygen availability were analyzed. The mathematical analysis included the effects of cerebral vasodilation, placental resistance to blood flow, degree of blood shunting by the ductus venosus and the effect of maternal-originated placental insufficiency. The model indicated a unimodal dependency between placental blood flow and cerebral oxygen availability. Optimal cerebral oxygen availability was achieved when the placental blood flow was mildly reduced compared to the normal flow. This optimal ratio was found to increase as the hypoxic state of FGR worsens. The model indicated that cerebral oxygen availability is increasingly dependent on the cardiac output distribution as the fetus gains weight.
- 25 August 2011
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 34 (3) , 364-369
The role of blood flow distribution in the regulation of cerebral oxygen availability in fetal growth restriction
Fetal growth restriction (FGR) elicits hemodynamic compensatory mechanisms in the fetal circulation. These mechanisms are complex and their effect on the cerebral oxygen availability is not fully understood. To quantify the contribution of each compensatory mechanism to the fetal cerebral oxygen availability, a mathematical model of the fetal circulation was developed. The model was based on cardiac-output distribution in the fetal circulation. The compensatory mechanisms of FGR were simulated and their effects on cerebral oxygen availability were analyzed. The mathematical analysis included the effects of cerebral vasodilation, placental resistance to blood flow, degree of blood shunting by the ductus venosus and the effect of maternal-originated placental insufficiency. The model indicated a unimodal dependency between placental blood flow and cerebral oxygen availability. Optimal cerebral oxygen availability was achieved when the placental blood flow was mildly reduced compared to the normal flow. This optimal ratio was found to increase as the hypoxic state of FGR worsens. The model indicated that cerebral oxygen availability is increasingly dependent on the cardiac output distribution as the fetus gains weight.
- 1 August 2009
- Published by Wiley in Journal of Obstetrics and Gynaecology Research
- Vol. 35 (4) , 654-659
Relations between fetal head descent and cervical dilatation during individual uterine contractions in the active stage of labor
The relationship between instantaneous changes in fetal head station and cervical dilatation within the individual contraction during the active stage of labor were studied and an index of labor progress was suggested. Cervix dilatation and fetal head station were measured continuously in 30 nullipara women (mean age 27.5, standard deviation 4.8). The continuous measurements enabled the analysis of each variable and the analysis of the relations between these two variables. The relationship between the head station and the cervical dilatation were demonstrated by plotting one against the other during a contraction. This led to the definition of a contraction vector that integrates the interaction between the two variables. The angle of this vector, that indicates this relation, was plotted against mean head station to demonstrate change along the delivery process regardless of time to normalize the progress and allow comparison between different women with different labor durations. This plot showed a sharp change from almost zero into a steep curve at about zero head station. A zero angle indicates that the cervix dilates during a contraction with little effect on head station while a steep angle indicates a significant effect of cervical dilatation on head station during the contraction. The contraction‐vector angle reflects the changing intra‐contraction relationship between head station and cervical dilatation. The angle of this vector may serve as an indicator of labor progress.
- 1 August 2009
- Published by Wiley in Journal of Obstetrics and Gynaecology Research
- Vol. 35 (4) , 654-659
Relations between fetal head descent and cervical dilatation during individual uterine contractions in the active stage of labor
The relationship between instantaneous changes in fetal head station and cervical dilatation within the individual contraction during the active stage of labor were studied and an index of labor progress was suggested. Cervix dilatation and fetal head station were measured continuously in 30 nullipara women (mean age 27.5, standard deviation 4.8). The continuous measurements enabled the analysis of each variable and the analysis of the relations between these two variables. The relationship between the head station and the cervical dilatation were demonstrated by plotting one against the other during a contraction. This led to the definition of a contraction vector that integrates the interaction between the two variables. The angle of this vector, that indicates this relation, was plotted against mean head station to demonstrate change along the delivery process regardless of time to normalize the progress and allow comparison between different women with different labor durations. This plot showed a sharp change from almost zero into a steep curve at about zero head station. A zero angle indicates that the cervix dilates during a contraction with little effect on head station while a steep angle indicates a significant effect of cervical dilatation on head station during the contraction. The contraction‐vector angle reflects the changing intra‐contraction relationship between head station and cervical dilatation. The angle of this vector may serve as an indicator of labor progress.
- 1 October 2007
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 21 (5) , 644-649
Right Atrial Effects on Right Ventricular Ejection Fraction Derived From Thermodilution Measurements
- 1 October 2007
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 21 (5) , 644-649
Right Atrial Effects on Right Ventricular Ejection Fraction Derived From Thermodilution Measurements
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2007 (1094687X) , 2697-2700
A Three Dimensional Heart Model Based on Anatomically Aligned Trusses
A new approach for modeling and simulating the contraction of the heart is presented. The model is based on anatomical images and accounts for cardiac muscle fibers and their orientation. The heart is modeled as a structure built of trusses, each representing a group of myofibers with calculated deformations using matrix structural analysis. Three elements are represented; these are the contractile cardiac muscle, the elastic passive collagen, and intracardiac blood interacting with the heart's preload and afterload. Incompressibility of each element is preserved. The conduction system is simulated in the model by transferring the activating signal from one element to another or by Purkinje fibers activation. The method was demonstrated using a three-dimensional one-layer geometrical ventricle with orthogonal fibers and with anatomically oriented fibers.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2007 (1094687X) , 2697-2700
A Three Dimensional Heart Model Based on Anatomically Aligned Trusses
A new approach for modeling and simulating the contraction of the heart is presented. The model is based on anatomical images and accounts for cardiac muscle fibers and their orientation. The heart is modeled as a structure built of trusses, each representing a group of myofibers with calculated deformations using matrix structural analysis. Three elements are represented; these are the contractile cardiac muscle, the elastic passive collagen, and intracardiac blood interacting with the heart's preload and afterload. Incompressibility of each element is preserved. The conduction system is simulated in the model by transferring the activating signal from one element to another or by Purkinje fibers activation. The method was demonstrated using a three-dimensional one-layer geometrical ventricle with orthogonal fibers and with anatomically oriented fibers.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2007 (1094687X) , 2992-2995
Fluid Resuscitation: Computer Simulation and Animal Experiments
The purpose of this study was to investigate the hemodynamic system in hemorrhagic shock and to estimate the effects of different infusion fluids and rates on the recovery of the bleeding patient. A mathematical model of the hemodynamic system was developed including fluid transfer to and from the interstitium for different types of fluids. The model was used to test different hemorrhagic shock conditions and different infusion conditions. To validate the model, a series of animal experiments was performed. The computer simulation followed successfully experimental data collected in five different experiments. Thus, it may now serve as an advanced tool for evaluating and analyzing effects of different fluids and optimize fluid regimen.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2007 (1094687X) , 2992-2995
Fluid Resuscitation: Computer Simulation and Animal Experiments
The purpose of this study was to investigate the hemodynamic system in hemorrhagic shock and to estimate the effects of different infusion fluids and rates on the recovery of the bleeding patient. A mathematical model of the hemodynamic system was developed including fluid transfer to and from the interstitium for different types of fluids. The model was used to test different hemorrhagic shock conditions and different infusion conditions. To validate the model, a series of animal experiments was performed. The computer simulation followed successfully experimental data collected in five different experiments. Thus, it may now serve as an advanced tool for evaluating and analyzing effects of different fluids and optimize fluid regimen.