Naureen S. Suteria
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Naureen S. Suteria has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Siva A. Vanapalli
Department of Chemical Engineering, Texas Tech University, Lubbock, TX, USA
3 shared publications - Nekouei
Department of Chemical Engineering, Texas Tech University, Lubbock, USA
1 shared publication Rajesh Potineni
Measurement Science, PepsiCo Global Functions Governance and Compliance, Hawthorne, USA
1 shared publication- Shamim M. Ahmmed
Department of Chemical Engineering, Texas Tech University, Lubbock, Texas 79409, USA
1 shared publication Siddhartha Gupta
Department of Chemical Engineering, Texas Tech University, Lubbock, USA
1 shared publicationStefan K. Baier
Measurement Science, PepsiCo Global Functions Governance and Compliance, Hawthorne, USA
1 shared publication
Latest Publications
- 20 May 2019
- Published by Springer Nature in Rheologica Acta
- Vol. 58 (6-7) , 403-417
eCapillary: a disposable microfluidic extensional viscometer for weakly elastic polymeric fluids
- 20 May 2019
- Published by Springer Nature in Rheologica Acta
- Vol. 58 (6-7) , 403-417
eCapillary: a disposable microfluidic extensional viscometer for weakly elastic polymeric fluids
- Open Access
- 1 January 2018
- Published by AIP Publishing in Biomicrofluidics
- Vol. 12 (1) , 014114
Hydrodynamic mobility of confined polymeric particles, vesicles, and cancer cells in a square microchannel
The transport of deformable objects, including polymer particles, vesicles, and cells, has been a subject of interest for several decades where the majority of experimental and theoretical studies have been focused on circular tubes. Due to advances in microfluidics, there is a need to study the transport of individual deformable particles in rectangular microchannels where corner flows can be important. In this study, we report measurements of hydrodynamic mobility of confined polymeric particles, vesicles, and cancer cells in a linear microchannel with a square cross-section. Our operating conditions are such that the mobility is measured as a function of geometric confinement over the range 0.3 < λ < 1.5 and at specified particle Reynolds numbers that are within 0.1 < Rep < 2.5. The experimental mobility data of each of these systems is compared with the circular-tube theory of Hestroni, Haber, and Wacholder [J. Fluid Mech. 41, 689–705 (1970)] with modifications made for a square cross-section. For polymeric particles, we find that the mobility data agrees well over a large confinement range with the theory but under predicts for vesicles. The mobility of vesicles is higher in a square channel than in a circular tube, and does not depend significantly on membrane mechanical properties. The mobility of cancer cells is in good agreement with the theory up to λ ≈ 0.8, after which it deviates. Comparison of the mobility data of the three systems reveals that cancer cells have higher mobility than rigid particles but lower than vesicles, suggesting that the cell membrane frictional properties are in between a solid-like interface and a fluid bilayer. We explain further the differences in the mobility of the three systems by considering their shape deformation and surface flow on the interface. The results of this study may find potential applications in drug delivery and biomedical diagnostics.
- 1 January 2018
- Published by AIP Publishing in Biomicrofluidics
- Vol. 12 (1) , 014114
Open AccessHydrodynamic mobility of confined polymeric particles, vesicles, and cancer cells in a square microchannel
The transport of deformable objects, including polymer particles, vesicles, and cells, has been a subject of interest for several decades where the majority of experimental and theoretical studies have been focused on circular tubes. Due to advances in microfluidics, there is a need to study the transport of individual deformable particles in rectangular microchannels where corner flows can be important. In this study, we report measurements of hydrodynamic mobility of confined polymeric particles, vesicles, and cancer cells in a linear microchannel with a square cross-section. Our operating conditions are such that the mobility is measured as a function of geometric confinement over the range 0.3 < λ < 1.5 and at specified particle Reynolds numbers that are within 0.1 < Rep < 2.5. The experimental mobility data of each of these systems is compared with the circular-tube theory of Hestroni, Haber, and Wacholder [J. Fluid Mech. 41, 689–705 (1970)] with modifications made for a square cross-section. For polymeric particles, we find that the mobility data agrees well over a large confinement range with the theory but under predicts for vesicles. The mobility of vesicles is higher in a square channel than in a circular tube, and does not depend significantly on membrane mechanical properties. The mobility of cancer cells is in good agreement with the theory up to λ ≈ 0.8, after which it deviates. Comparison of the mobility data of the three systems reveals that cancer cells have higher mobility than rigid particles but lower than vesicles, suggesting that the cell membrane frictional properties are in between a solid-like interface and a fluid bilayer. We explain further the differences in the mobility of the three systems by considering their shape deformation and surface flow on the interface. The results of this study may find potential applications in drug delivery and biomedical diagnostics.
- 14 December 2017
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 18 (2) , 343-355
Microfluidic bypass manometry: highly parallelized measurement of flow resistance of complex channel geometries and trapped droplets
Current lithography methods allow facile fabrication of microfluidic conduits where not only the shape of the bounding walls can be arbitrarily varied but also the internal conduit space can be laden with a variety of microstructures and wetting properties. This virtually infinite design space of microfluidic geometries brings in the challenge of how to quantify fluid resistance in a large number of microfluidic conduits, while maintaining operational simplicity. We report a versatile experimental technique referred to as microfluidic bypass manometry for measurement of pressure drop versus flow rate (ΔP–Q) relations in a parallelized manner. The technique involves introducing co-flowing laminar streams into a microfluidic network that contains a series of loops, where each loop is comprised of a test geometry and a bypass channel as a flow-rate sensing element. We optimize the network geometry and present operational considerations for microfluidic bypass manometry. To demonstrate the power of our technique, we used single-phase fluids and measured ΔP–Q relations simultaneously for forty test geometries ranging from linear to contraction–expansion to serpentine to pillar-laden microchannels. To expand the capabilities of the method, we measured ΔP–Q relations for similar-sized oil droplets trapped in microcavities where the cavity geometry spans from prisms of 3–10 sides to circular disks. We found in all cases, the ΔP–Q relation is nonlinear and the flow resistance of droplets is sensitive to confinement. At high flow rates, the drop resistance depends on the cavity geometry and is higher in a triangular prism compared to a circular disk. We compared the measured flow resistance of single-phase fluids and droplets in different microfluidic geometries to that from computational fluid dynamics simulations and found them to be in excellent agreement. Given the simplicity and versatility of the microfluidic bypass manometry method, we anticipate that it may find broad application in several areas including design of lab-on-chip devices, laminar drag reduction and mechanics of deformable particles.
- 14 December 2017
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 18 (2) , 343-355
Microfluidic bypass manometry: highly parallelized measurement of flow resistance of complex channel geometries and trapped droplets
Current lithography methods allow facile fabrication of microfluidic conduits where not only the shape of the bounding walls can be arbitrarily varied but also the internal conduit space can be laden with a variety of microstructures and wetting properties. This virtually infinite design space of microfluidic geometries brings in the challenge of how to quantify fluid resistance in a large number of microfluidic conduits, while maintaining operational simplicity. We report a versatile experimental technique referred to as microfluidic bypass manometry for measurement of pressure drop versus flow rate (ΔP–Q) relations in a parallelized manner. The technique involves introducing co-flowing laminar streams into a microfluidic network that contains a series of loops, where each loop is comprised of a test geometry and a bypass channel as a flow-rate sensing element. We optimize the network geometry and present operational considerations for microfluidic bypass manometry. To demonstrate the power of our technique, we used single-phase fluids and measured ΔP–Q relations simultaneously for forty test geometries ranging from linear to contraction–expansion to serpentine to pillar-laden microchannels. To expand the capabilities of the method, we measured ΔP–Q relations for similar-sized oil droplets trapped in microcavities where the cavity geometry spans from prisms of 3–10 sides to circular disks. We found in all cases, the ΔP–Q relation is nonlinear and the flow resistance of droplets is sensitive to confinement. At high flow rates, the drop resistance depends on the cavity geometry and is higher in a triangular prism compared to a circular disk. We compared the measured flow resistance of single-phase fluids and droplets in different microfluidic geometries to that from computational fluid dynamics simulations and found them to be in excellent agreement. Given the simplicity and versatility of the microfluidic bypass manometry method, we anticipate that it may find broad application in several areas including design of lab-on-chip devices, laminar drag reduction and mechanics of deformable particles.