Thomas Joseph Ford
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Thomas Joseph Ford has a total of 514 co-authors. Here are the top co-authors by number of shared publications:
- Colin Berry
BHF Glasgow Cardiovascular Research Centre, University of Glasgow, Glasgow, UK
24 shared publications Margaret McEntegart
Department of Cardiology, Columbia University, New York, New York, USA
16 shared publicationsColin Berry
West of Scotland Regional Heart and Lung Centre, Golden Jubilee National Hospital, Clydebank, United Kingdom; British Heart Foundation Glasgow Cardiovascular Research Centre, University of Glasgow, Glasgow, United Kingdom
12 shared publicationsPaul Rocchiccioli
Cardiology Department, Golden Jubilee National Hospital, Glasgow, United Kingdom
12 shared publicationsAadil Shaukat
West of Scotland Regional Heart & Lung Centre, Golden Jubilee National Hospital , Agamemnon Street, Clydebank, G81 4DY, UK
11 shared publicationsDavid Corcoran
British Heart Foundation Glasgow Cardiovascular Research Center, University of Glasgow, Glasgow, United Kingdom
11 shared publications
Latest Publications
- Open Access
- 23 September 2026
- Published by Elsevier in SSRN Electronic Journal
Streamlined Functional Coronary Angiography: Intracoronary Bolus Adenosine Is Associated With Shorter Procedure Time While Preserving Diagnostic Performance
Background: Invasive coronary function testing (CFT) identifies coronary vasomotor disorders in patients with suspected ischaemia with non-obstructive coronary arteries (INOCA), but intravenous adenosine protocols may increase procedural complexity. We evaluated whether a streamlined intracoronary bolus adenosine protocol was associated with shorter procedure duration and compared diagnostic yield and identified endotypes between protocols.Methods: We performed a two-centre cohort study of 166 patients undergoing CFT after angiographically confirmed non-obstructive coronary disease. Patients received a streamlined intracoronary bolus protocol (n=93) or standard intravenous-based care (n=73) according to operator preference. The primary endpoint was procedure duration. Secondary endpoints included heparin dose, diagnostic yield, coronary microvascular dysfunction (CMD), vasospasm, mixed endotype and complications. Multivariable regression adjusted for age, sex, hospital, proceduralist and acetylcholine testing.Results: Procedure duration was shorter with the streamlined protocol (median 21 [IQR 16–30] vs 32 [25–39] minutes; adjusted difference −4.8 minutes, 95% CI −7.5 to −2.1, p=0.0005), as was heparin dose (median 5000 [4000–5000] vs 6000 [5000–7000] IU; adjusted difference −562 IU, 95% CI −1115 to −8, p=0.047). Diagnostic yield (69% vs 59%, p=0.20) and CMD (38% vs 37%) did not differ significantly. Among acetylcholine-tested patients, vasospasm (45% vs 45%) and mixed endotype (9.5% vs 17.5%) also did not differ significantly.Conclusions: A streamlined intracoronary adenosine protocol was associated with shorter procedure duration and lower heparin dose during CFT. No statistically significant differences were detected in diagnostic yield, identified endotypes or acetylcholine-related complications. Larger randomised trials are warranted.
- 23 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessStreamlined Functional Coronary Angiography: Intracoronary Bolus Adenosine Is Associated With Shorter Procedure Time While Preserving Diagnostic Performance
Background: Invasive coronary function testing (CFT) identifies coronary vasomotor disorders in patients with suspected ischaemia with non-obstructive coronary arteries (INOCA), but intravenous adenosine protocols may increase procedural complexity. We evaluated whether a streamlined intracoronary bolus adenosine protocol was associated with shorter procedure duration and compared diagnostic yield and identified endotypes between protocols.Methods: We performed a two-centre cohort study of 166 patients undergoing CFT after angiographically confirmed non-obstructive coronary disease. Patients received a streamlined intracoronary bolus protocol (n=93) or standard intravenous-based care (n=73) according to operator preference. The primary endpoint was procedure duration. Secondary endpoints included heparin dose, diagnostic yield, coronary microvascular dysfunction (CMD), vasospasm, mixed endotype and complications. Multivariable regression adjusted for age, sex, hospital, proceduralist and acetylcholine testing.Results: Procedure duration was shorter with the streamlined protocol (median 21 [IQR 16–30] vs 32 [25–39] minutes; adjusted difference −4.8 minutes, 95% CI −7.5 to −2.1, p=0.0005), as was heparin dose (median 5000 [4000–5000] vs 6000 [5000–7000] IU; adjusted difference −562 IU, 95% CI −1115 to −8, p=0.047). Diagnostic yield (69% vs 59%, p=0.20) and CMD (38% vs 37%) did not differ significantly. Among acetylcholine-tested patients, vasospasm (45% vs 45%) and mixed endotype (9.5% vs 17.5%) also did not differ significantly.Conclusions: A streamlined intracoronary adenosine protocol was associated with shorter procedure duration and lower heparin dose during CFT. No statistically significant differences were detected in diagnostic yield, identified endotypes or acetylcholine-related complications. Larger randomised trials are warranted.
- Open Access
- 9 September 2026
- Published by Wiley in Catheterization and Cardiovascular Interventions
Diagnostic Accuracy and Feasibility of Quantitative Flow Ratio at Low Frame Rate Angiography: The Prospective Multicentre Australian AVALON Study
Background: Quantitative Flow Ratio (QFR) is a well‐established, non‐hyperemic, angiographic, wire‐free predictor of ischemia when compared to Fractional Flow Reserve (FFR). However, its diagnostic accuracy at low frame rates (< 10 frames/second), commonly used in contemporary practice to minimize radiation exposure, has not been evaluated. Aims: To assess the diagnostic accuracy of QFR when acquired at lower frame rates in line with contemporary practice. Methods: The AVALON trial—a prospective, multi‐center, Australian study—included patients undergoing invasive coronary angiography (ICA) and FFR assessment for stable coronary artery disease (CAD). QFR analysis was performed using Medis QAngio XA QFR 2.2.2.4 software. Significant QFR and FFR were defined as < 0.80. Results: Among 1054 patients (66.8 ± 10.4 years, 585 males, 797 vessels), the mean FFR was 0.81 ± 0.10, with 312 vessels (39%) classified as FFR significant. The mean QFR was 0.81 ± 0.10, and 352 vessels (44%) were QFR significant. QFR demonstrated strong diagnostic performance in predicting significant FFR with AUC of 0.92 ( p < 0.001). It exhibited sensitivity of 85%, specificity 89%, positive predictive value (PPV) 83%, negative predictive value (NPV) 90%, and diagnostic accuracy 87%. Interobserver reliability for QFR was excellent (ICC = 0.92, p < 0.001). Using the established QFR‐FFR hybrid approach, where FFR was performed only if QFR ranged between 0.77 and 0.87, FFR could be safely deferred in 58% of cases, achieving a diagnostic accuracy of 93.8%. Conclusion: QFR remains highly accurate in predicting significant FFR, even when angiography is acquired at low frame rates. The QFR‐FFR hybrid approach effectively minimizes the need for invasive FFR measurements, with the potential to enhance clinical efficiency while maintaining high diagnostic precision.
- 9 September 2026
- Published by Wiley in Catheterization and Cardiovascular Interventions
Open AccessDiagnostic Accuracy and Feasibility of Quantitative Flow Ratio at Low Frame Rate Angiography: The Prospective Multicentre Australian AVALON Study
Background: Quantitative Flow Ratio (QFR) is a well‐established, non‐hyperemic, angiographic, wire‐free predictor of ischemia when compared to Fractional Flow Reserve (FFR). However, its diagnostic accuracy at low frame rates (< 10 frames/second), commonly used in contemporary practice to minimize radiation exposure, has not been evaluated. Aims: To assess the diagnostic accuracy of QFR when acquired at lower frame rates in line with contemporary practice. Methods: The AVALON trial—a prospective, multi‐center, Australian study—included patients undergoing invasive coronary angiography (ICA) and FFR assessment for stable coronary artery disease (CAD). QFR analysis was performed using Medis QAngio XA QFR 2.2.2.4 software. Significant QFR and FFR were defined as < 0.80. Results: Among 1054 patients (66.8 ± 10.4 years, 585 males, 797 vessels), the mean FFR was 0.81 ± 0.10, with 312 vessels (39%) classified as FFR significant. The mean QFR was 0.81 ± 0.10, and 352 vessels (44%) were QFR significant. QFR demonstrated strong diagnostic performance in predicting significant FFR with AUC of 0.92 ( p < 0.001). It exhibited sensitivity of 85%, specificity 89%, positive predictive value (PPV) 83%, negative predictive value (NPV) 90%, and diagnostic accuracy 87%. Interobserver reliability for QFR was excellent (ICC = 0.92, p < 0.001). Using the established QFR‐FFR hybrid approach, where FFR was performed only if QFR ranged between 0.77 and 0.87, FFR could be safely deferred in 58% of cases, achieving a diagnostic accuracy of 93.8%. Conclusion: QFR remains highly accurate in predicting significant FFR, even when angiography is acquired at low frame rates. The QFR‐FFR hybrid approach effectively minimizes the need for invasive FFR measurements, with the potential to enhance clinical efficiency while maintaining high diagnostic precision.
- Open Access
- 3 March 2026
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 15 (5) , e042260
Spontaneous Coronary Artery Dissection: Sex Differences in Clinical Presentation and Outcomes From the Australian New Zealand Registry
Background: Spontaneous coronary artery dissection (SCAD) predominantly affects women with limited data in men. We aimed to determine sex differences in SCAD presentation, associated conditions, and major adverse cardiovascular events (MACE). Methods: Cohort study of 23 ANZ‐SCAD sites (Australian/New Zealand Registry, data previously published) with core laboratory confirmed SCAD. Descriptive statistics for sex differences. Interaction analysis with Cox proportional hazards model assessed the effect of sex on previously published independent predictors of MACE. Results: Of a total of 527 patients with SCAD, 468 (88.8%) were female. Mean age was similar, at 53.5±10.6 in women and 52.2±10.7 in men. Women had higher rates of hypertension (30.6% versus 16.9% men, P =0.044). Emotional stress as a SCAD precipitant was documented in the medical records in more women (16.0% versus 2.9% men, P =0.042) with no difference when self‐reported (60.6% women versus 54.2% men, P =0.715). Women were more likely to have moderate/severe coronary tortuosity (55.0% versus 34.6% men, P =0.009). Fibromuscular dysplasia (FMD) was detected in 24.2% versus 16.7% ( P =0.612) and non‐FMD vascular abnormalities in 4.0% versus 16.7% ( P =0.027) of women versus men screened. There was no sex difference in 3‐year MACE; 8.2% women, 11.9% men (log‐rank P =0.2). There was no interaction by sex (all P values >0.05) with variables associated with increased MACE, namely oral anticoagulation, dual antiplatelet therapy comprising aspirin and ticagrelor, FMD, and previous stroke. Conclusions: Women with SCAD had higher rates of hypertension, coronary tortuosity, and FMD, whereas men had more non‐FMD vascular abnormalities. Self‐reported emotional stress was common, equally prevalent in women and men. Anticoagulation, dual antiplatelet therapy, FMD, and previous stroke were independent predictors of MACE in both women and men. Registration: URL: https://anzctr.org.au/ ; Unique Identifier: 12621000824864.
- 3 March 2026
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 15 (5) , e042260
Open AccessSpontaneous Coronary Artery Dissection: Sex Differences in Clinical Presentation and Outcomes From the Australian New Zealand Registry
Background: Spontaneous coronary artery dissection (SCAD) predominantly affects women with limited data in men. We aimed to determine sex differences in SCAD presentation, associated conditions, and major adverse cardiovascular events (MACE). Methods: Cohort study of 23 ANZ‐SCAD sites (Australian/New Zealand Registry, data previously published) with core laboratory confirmed SCAD. Descriptive statistics for sex differences. Interaction analysis with Cox proportional hazards model assessed the effect of sex on previously published independent predictors of MACE. Results: Of a total of 527 patients with SCAD, 468 (88.8%) were female. Mean age was similar, at 53.5±10.6 in women and 52.2±10.7 in men. Women had higher rates of hypertension (30.6% versus 16.9% men, P =0.044). Emotional stress as a SCAD precipitant was documented in the medical records in more women (16.0% versus 2.9% men, P =0.042) with no difference when self‐reported (60.6% women versus 54.2% men, P =0.715). Women were more likely to have moderate/severe coronary tortuosity (55.0% versus 34.6% men, P =0.009). Fibromuscular dysplasia (FMD) was detected in 24.2% versus 16.7% ( P =0.612) and non‐FMD vascular abnormalities in 4.0% versus 16.7% ( P =0.027) of women versus men screened. There was no sex difference in 3‐year MACE; 8.2% women, 11.9% men (log‐rank P =0.2). There was no interaction by sex (all P values >0.05) with variables associated with increased MACE, namely oral anticoagulation, dual antiplatelet therapy comprising aspirin and ticagrelor, FMD, and previous stroke. Conclusions: Women with SCAD had higher rates of hypertension, coronary tortuosity, and FMD, whereas men had more non‐FMD vascular abnormalities. Self‐reported emotional stress was common, equally prevalent in women and men. Anticoagulation, dual antiplatelet therapy, FMD, and previous stroke were independent predictors of MACE in both women and men. Registration: URL: https://anzctr.org.au/ ; Unique Identifier: 12621000824864.
- Open Access
- 28 January 2026
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 107 (5) , 1389-1392
The “Skipping Rope” Technique: A Novel Strategy for Distal Burr Entrapment During Rotational Atherectomy
We describe the “skipping rope technique” for managing burr entrapment during rotational atherectomy. Sequential counterclockwise rotational force is applied to the drive shaft, generating alternative torque dynamics. This maneuver provides a safe method to disengage a stuck rotaburr, offering operators an additional strategy for this challenging complication.
- 28 January 2026
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 107 (5) , 1389-1392
Open AccessThe “Skipping Rope” Technique: A Novel Strategy for Distal Burr Entrapment During Rotational Atherectomy
We describe the “skipping rope technique” for managing burr entrapment during rotational atherectomy. Sequential counterclockwise rotational force is applied to the drive shaft, generating alternative torque dynamics. This maneuver provides a safe method to disengage a stuck rotaburr, offering operators an additional strategy for this challenging complication.
- 27 December 2025
- Published by Elsevier in Heart, Lung and Circulation
- Vol. 35 (2) , 249-258
Safety and Workflow Using Rotational Atherectomy in Non-Surgical Centres—The SWAN Study
- 27 December 2025
- Published by Elsevier in Heart, Lung and Circulation
- Vol. 35 (2) , 249-258
Safety and Workflow Using Rotational Atherectomy in Non-Surgical Centres—The SWAN Study
- 15 June 2025
- Published by Springer Nature
- p. 163-169
Hand Function
- Open Access
- 7 January 2025
- Published by Elsevier in JACC: Asia
- Vol. 5 (1) , 56-58
Perforations in Complex PCI
- 7 January 2025
- Published by Elsevier in JACC: Asia
- Vol. 5 (1) , 56-58
Open AccessPerforations in Complex PCI
- Open Access
Coronary microvascular function and atherosclerotic plaque burden in ischaemia and no obstructive coronary arteries: a secondary analysis of the CorMicA trial
Background The relationship between atherosclerosis and endotypes of myocardial ischaemia with no obstructive coronary artery disease (INOCA) is unclear. We investigated potential associations between cumulative atherosclerotic plaque burden quantified using the Gensini score, novel invasive indices of coronary microvascular function (microvascular resistance reserve (MRR); resistive reserve ratio (RRR)) and related INOCA endotypes. Methods Coronary angiography and invasive coronary function tests were simultaneously acquired in the CorMicA cohort. A comprehensive physiological assessment was performed using both a thermodilution-based diagnostic guidewire and intracoronary acetylcholine provocation testing. Angiograms were examined for luminal stenosis in each segment of the SYNTAX coronary model. Cumulative plaque burden was quantified using the Gensini score, which incorporated both the number of diseased coronary segments and stenosis severity. Results were compared with indices of microvascular function and INOCA endotypes. Angiographic analyses were performed blind to coronary physiology findings. Results In 151 participants (median age 61 years; 73.5% female) without flow-limiting coronary artery disease, medical history included 41.7% smoking, 63.6% hypertension and 19.2% diabetes mellitus. The left anterior descending artery underwent diagnostic guidewire testing in 85.4%, and 55.0% of participants had abnormal coronary flow reserve (CFR) and/or Index of Microcirculatory Resistance (IMR). The median Gensini score was 6.0 (IQR 2.5–11.0). CFR (p=0.012), MRR (p=0.026) and RRR (p=0.026), but not IMR (p=0.445), were univariably associated with raised Gensini scores. These significant effects persisted in multivariable models controlling for potential confounders. Considering INOCA endotypes, Gensini scores differed among participants with microvascular angina (MVA) (7.0 (2.5–11.0)), vasospastic angina (VSA) (4.5 (2.0–10.0)), mixed MVA/VSA (9.0 (5.0–11.5)) and non-cardiac symptoms (3.5 (1.5–8.0)); Kruskal-Wallis p=0.030. Conclusions Reduced CFR, MRR and RRR, and MVA were associated with increased coronary atherosclerotic plaque burden, as evidenced by higher Gensini scores. These novel findings provide a mechanistic link between INOCA and cardiovascular events, reinforcing the importance of antiatherosclerosis therapy in patients with MVA.
Open AccessCoronary microvascular function and atherosclerotic plaque burden in ischaemia and no obstructive coronary arteries: a secondary analysis of the CorMicA trial
Background The relationship between atherosclerosis and endotypes of myocardial ischaemia with no obstructive coronary artery disease (INOCA) is unclear. We investigated potential associations between cumulative atherosclerotic plaque burden quantified using the Gensini score, novel invasive indices of coronary microvascular function (microvascular resistance reserve (MRR); resistive reserve ratio (RRR)) and related INOCA endotypes. Methods Coronary angiography and invasive coronary function tests were simultaneously acquired in the CorMicA cohort. A comprehensive physiological assessment was performed using both a thermodilution-based diagnostic guidewire and intracoronary acetylcholine provocation testing. Angiograms were examined for luminal stenosis in each segment of the SYNTAX coronary model. Cumulative plaque burden was quantified using the Gensini score, which incorporated both the number of diseased coronary segments and stenosis severity. Results were compared with indices of microvascular function and INOCA endotypes. Angiographic analyses were performed blind to coronary physiology findings. Results In 151 participants (median age 61 years; 73.5% female) without flow-limiting coronary artery disease, medical history included 41.7% smoking, 63.6% hypertension and 19.2% diabetes mellitus. The left anterior descending artery underwent diagnostic guidewire testing in 85.4%, and 55.0% of participants had abnormal coronary flow reserve (CFR) and/or Index of Microcirculatory Resistance (IMR). The median Gensini score was 6.0 (IQR 2.5–11.0). CFR (p=0.012), MRR (p=0.026) and RRR (p=0.026), but not IMR (p=0.445), were univariably associated with raised Gensini scores. These significant effects persisted in multivariable models controlling for potential confounders. Considering INOCA endotypes, Gensini scores differed among participants with microvascular angina (MVA) (7.0 (2.5–11.0)), vasospastic angina (VSA) (4.5 (2.0–10.0)), mixed MVA/VSA (9.0 (5.0–11.5)) and non-cardiac symptoms (3.5 (1.5–8.0)); Kruskal-Wallis p=0.030. Conclusions Reduced CFR, MRR and RRR, and MVA were associated with increased coronary atherosclerotic plaque burden, as evidenced by higher Gensini scores. These novel findings provide a mechanistic link between INOCA and cardiovascular events, reinforcing the importance of antiatherosclerosis therapy in patients with MVA.
- Open Access
- 19 November 2024
- Published by Wolters Kluwer Health in Circulation
- Vol. 150 (21) , 1671-1683
Zibotentan in Microvascular Angina: A Randomized, Placebo-Controlled, Crossover Trial
BACKGROUND: Microvascular angina is associated with dysregulation of the endothelin system and impairments in myocardial blood flow, exercise capacity, and health-related quality of life. The G allele of the noncoding single nucleotide polymorphism RS9349379 enhances expression of the endothelin-1 gene ( EDN1 ) in human vascular cells, potentially increasing circulating concentrations of Endothelin-1 (ET-1). Whether zibotentan, an oral ET-A receptor selective antagonist, is efficacious and safe for the treatment of microvascular angina is unknown. METHODS: Patients with microvascular angina were enrolled in this double-blind, placebo-controlled, sequential crossover trial of zibotentan (10 mg daily for 12 weeks). The trial population was enriched to ensure a G allele frequency of 50% for the RS9349379 single nucleotide polymorphism. Participants and investigators were blinded to genotype. The primary outcome was treadmill exercise duration (seconds) using the Bruce protocol. The primary analysis estimated the mean within-participant difference in exercise duration after treatment with zibotentan versus placebo. RESULTS: A total of 118 participants (mean±SD; years of age 63.5 [9.2]; 71 [60.2%] females; 25 [21.2%] with diabetes) were randomized. Among 103 participants with complete data, the mean exercise duration with zibotentan treatment compared with placebo was not different (between-treatment difference, −4.26 seconds [95% CI, −19.60 to 11.06] P =0.5871). Secondary outcomes showed no improvement with zibotentan. Zibotentan reduced blood pressure and increased plasma concentrations of ET-1. Adverse events were more common with zibotentan (60.2%) compared with placebo (14.4%; P <0.001). CONCLUSIONS: Among patients with microvascular angina, short-term treatment with a relatively high dose (10 mg daily) of zibotentan was not beneficial. Target-related adverse effects were common. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04097314.
- 19 November 2024
- Published by Wolters Kluwer Health in Circulation
- Vol. 150 (21) , 1671-1683
Open AccessZibotentan in Microvascular Angina: A Randomized, Placebo-Controlled, Crossover Trial
BACKGROUND: Microvascular angina is associated with dysregulation of the endothelin system and impairments in myocardial blood flow, exercise capacity, and health-related quality of life. The G allele of the noncoding single nucleotide polymorphism RS9349379 enhances expression of the endothelin-1 gene ( EDN1 ) in human vascular cells, potentially increasing circulating concentrations of Endothelin-1 (ET-1). Whether zibotentan, an oral ET-A receptor selective antagonist, is efficacious and safe for the treatment of microvascular angina is unknown. METHODS: Patients with microvascular angina were enrolled in this double-blind, placebo-controlled, sequential crossover trial of zibotentan (10 mg daily for 12 weeks). The trial population was enriched to ensure a G allele frequency of 50% for the RS9349379 single nucleotide polymorphism. Participants and investigators were blinded to genotype. The primary outcome was treadmill exercise duration (seconds) using the Bruce protocol. The primary analysis estimated the mean within-participant difference in exercise duration after treatment with zibotentan versus placebo. RESULTS: A total of 118 participants (mean±SD; years of age 63.5 [9.2]; 71 [60.2%] females; 25 [21.2%] with diabetes) were randomized. Among 103 participants with complete data, the mean exercise duration with zibotentan treatment compared with placebo was not different (between-treatment difference, −4.26 seconds [95% CI, −19.60 to 11.06] P =0.5871). Secondary outcomes showed no improvement with zibotentan. Zibotentan reduced blood pressure and increased plasma concentrations of ET-1. Adverse events were more common with zibotentan (60.2%) compared with placebo (14.4%; P <0.001). CONCLUSIONS: Among patients with microvascular angina, short-term treatment with a relatively high dose (10 mg daily) of zibotentan was not beneficial. Target-related adverse effects were common. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04097314.
- Open Access
- 30 June 2024
- Published by Elsevier in Heart, Lung and Circulation
- Vol. 33 (9) , 1287-1296
Protocol Variation in Functional Coronary Angiography Among Patients With Suspected Angina With Non-Obstructive Coronary Arteries: A Nationwide Snapshot of Current Practice Within Australia and New Zealand
- 30 June 2024
- Published by Elsevier in Heart, Lung and Circulation
- Vol. 33 (9) , 1287-1296
Open AccessProtocol Variation in Functional Coronary Angiography Among Patients With Suspected Angina With Non-Obstructive Coronary Arteries: A Nationwide Snapshot of Current Practice Within Australia and New Zealand