FGFan Gao

Fan Gao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Fan Gao has a total of 20 co-authors. Here are the top co-authors by number of shared publications:

  • Susan Kapp

    UT Southwestern Medical Center at Dallas, Dallas, TX, USA

    2 shared publications
  • Bill Carlton

    Prosthetics-Orthotics Program, Department of Health Care Sciences, School of Health Professions, UT Southwestern Medical Center at Dallas, Dallas, USA

    1 shared publication
  • Borui Dong

    Cancer Hospital of Dalian University of Technology, Dalian, China

    1 shared publication
  • Dario Villarreal

    The University of Texas at Dallas, Richardson, TX, USA

    1 shared publication
  • Fan Zhang

    Biomedical Engineering Department, University of Rhode Island, Kingston, RI 02881 USA

    1 shared publication
  • Gary G. Co Bedard

    FAN GAO, PhD, is affiliated with the Department of Health Care Sciences, UT Southwestern Medical Center, Dallas, Texas

    1 shared publication

Latest Publications

  • A Computational Method to Identify Optimal Functional Muscle Synergies From Estimated Muscle Activations

    by Yaru Chen, Yongxuan Wang, Fan Gao, Borui Dong, Wenqian Chen, Rong Liu

    Achieving reliable muscle synergies (MSs) is critical for optimizing motor control in neuromusculoskeletal robotics. Existing MS extraction approaches are limited by traditional electromyography (EMG) acquisition constraints, variability due to methodological differences, and difficulty in assessing the contribution of deep and small muscle groups to optimal MSs. To overcome these challenges, we developed the Determination of Optimal Functional MSs from Estimated Muscle Activations (DOMSn-EMAs), a novel computational approach elucidating the impact of high-density estimated muscle activations (EMAs) on optimal functional MSs under specific biomechanical task constraints. DOMSn-EMAs comprises three key steps: (1) computing high-density EMAs through measured human motion data and high-fidelity musculoskeletal modeling with a modified computed muscle control algorithm, constrained by limited surface EMG tracking; (2) extracting sparse MS properties using sparse non-negative matrix factorization (SNMF) to improve reconstruction accuracy and repeatability; and (3) introducing a composite reliability index for optimal MS number identification. Validation on a publicly available dataset from 10 subjects confirms DOMSn-EMAs’ reliability. The results identify five optimal MSs from 43 EMAs, with an independent MS involving deep and small muscle groups during the early swing phase. This approach corroborates the similarity between EMG-derived and EMAs-derived synergies while identifying EMAs’ potential influence on optimal functional MSs. DOMSn-EMAs provides a pioneering and practical approach for synergy analysis, ensuring more reliable and sophisticated MSs than previous modular architectures for robotics applications.


  • Evaluation of transradial body-powered prostheses using a robotic simulator

    by Rafi Ayub, Dario Villarreal, Robert D Gregg, Fan Gao

    Transradial body-powered prostheses are extensively used by upper-limb amputees. This prosthesis requires large muscle forces and great concentration by the patient, often leading to discomfort, muscle fatigue, and skin breakdown, limiting the capacity of the amputee to conduct daily activities. Since body-powered prostheses are commonplace, understanding their optimal operation to mitigate these drawbacks would be clinically meaningful. To find the optimal operation of the prosthesis where the activation force is minimized and the grip force is maximized. Experimental design. A computer-controlled robotic amputee simulator capable of rapidly testing multiple elbow, shoulder, and scapular combinations of the residual human arm was constructed. It was fitted with a transradial prosthesis and used to systematically test multiple configurations. We found that increased shoulder flexion, scapular abduction, elbow extension, and the placement of the ring harness near the vertebra C7 correlate with higher gripper operation efficiency, defined as the ratio of grip force to cable tension. We conclude that force transmission efficiency is closely related to body posture configuration. These results could help guide practitioners in clinical practice as well as motivate future studies in optimizing the operation of a body-powered prosthesis. The results from this study suggest that clinicians ought to place the ring harness inferior and to the sound side of the vertebra prominens in order to maximize grip efficiency. The results will also help clinicians better instruct patients in body posture during prosthesis operation to minimize strain.


  • Open Access

    Advances in Rehabilitation and Assistive Robots for Restoring Limb Function in Persons with Movement Disorders

    by Fan Gao, Guanglin Li, Huapeng Wu, Qining Wang, Jie Liu, Justin Keogh

  • An experimental apparatus to simulate body-powered prosthetic usage

    by Fan Gao, Johanan Rodriguez, Susan Kapp

    Harness fitting in the body-powered prosthesis remains more art than science due to a lack of consistent and quantitative evaluation. The aim of this study was to develop a mechanical, human-body-shaped apparatus to simulate body-powered upper limb prosthetic usage and evaluate its capability of quantitative examination of harness configuration. The apparatus was built upon a torso of a wooden mannequin and integrated major mechanical joints to simulate terminal device operation. Sensors were used to register cable tension, cable excursion, and grip force simultaneously. The apparatus allowed the scapula to move up to 127 mm laterally and the load cell can measure the cable tension up to 445 N. Our preliminary evaluation highlighted the needs and importance of investigating harness configurations in a systematic and controllable manner. The apparatus allows objective, systematic, and quantitative evaluation of effects of realistic harness configurations and will provide insightful and working knowledge on harness fitting in upper limb amputees using body-powered prosthesis.


  • Effects of Materials, Reinforcement, and Heat Treatment on Thermoplastic Solid Ankle-Foot Orthosis Mechanical Properties

    by Fan Gao, Gary G. Co Bedard

    The mechanical properties of a solid ankle-foot orthosis (SAFO) are essential and can directly affect its capability of restricting ankle joint and impact the gait patterns in a population with movement disorders. A better understanding of the effects of materials, reinforcement techniques, and annealing on its mechanical properties will be useful and helpful for practitioners to improve the criteria of both design and prescription. The objective of this preliminary study was to provide quantitative outcomes regarding the mechanical properties of a SAFO with various materials, reinforcement techniques, and heat treatment. Eight SAFOs were fabricated with three types of thermoplastic materials (homopolymer polypropylene, copolymer polypropylene, and carbon-infused homopolymer polypropylene) and two reinforcement methods (corrugated and compcore). In addition, the homopolymer polypropylene SAFO without reinforcement was annealed at 185°F. A computer-controlled motorized test apparatus was used to load the SAFOs within 20 Nm resistance torques in both dorsiflexion and plantarflexion at 5°/s. The mechanical properties of the SAFOs, including range of motion, quasi-static stiffness at selected resistance torques, and index of hysteresis, were quantified based on the loading curves. Our preliminary results show that materials, reinforcement techniques, and heat treatment affect the mechanical properties of the fabricated SAFOs to different levels. Among the materials used, carbon-infused homopolymer polypropylene outperforms the other two popularly used polypropylenes. The compcore reinforcement technique is more favored than the corrugated reinforcement technique. Lastly, annealing has shown promising effects on improving the overall mechanical properties of homopolymer polypropylene SAFOs.


  • Power grip force is modulated in repeated elbow movement

    by Fan Gao

    The objective of this study was to quantitatively investigate the modulation of power grip force under repeated elbow movement and its relation to muscle cocontraction and potential risk of developing cumulative trauma disorders (CTD). Thirteen right-handed participants without any neuromuscular disorders were recruited. Participants were instructed to hold a digital dynamometer in the hand with three levels of grip forces (20%, 40% and 60% of the maximum grip force) and perform repeated arm movement in the sagittal plane at three speeds (slow, self-paced and fast) with the upper arm voluntarily held by side by the participant. With the increase of motion rate and target force level, the grip force fluctuation, finger flexor muscle activities, elbow muscles cocontraction and apparent stiffness were significantly increased (p < 0.01). This study suggests that the power grip coupled with fast arm movement be avoided as much as possible in the workplace. Practitioner Summary: Power grip is usually accompanied with arm movement in workplaces and the increased physical demand might result in higher muscle activities and potentially higher risk of repetitive musculoskeletal injuries.


  • Investigation of sit-to-stand and stand-to-sit in an above knee amputee

    by Fan Gao, Fan Zhang, He Huang

    The objective of this pilot study is twofold: 1) to extract key factors/features in sit-to-stand and stand-to-sit (STS) performed by an above knee (AK) amputee; 2) to propose a convenient way to quantify symmetry. One male unilateral transfemoral amputee participated in the pilot study. The subject was instructed to rise in a comfortable and natural manner and conduct a series of sit-to-stand, stand-to-sit. We simultaneously measured kinematics, kinetics and muscle activities. Principal component analysis (PCA) was used to reduce the dimension and identify modes and a convenient index of STS symmetry (slope of the major axis of the error ellipse) is proposed using the insole pressure sensors. Based on the preliminary results it is recommended that kinematics and kinetics in both the sagittal and frontal planes be considered for an AK amputee performing STS. The information might be useful for further research on amputee STS.


  • Open Access

    Effects of joint alignment and type on mechanical properties of thermoplastic articulated ankle-foot orthosis

    by Fan Gao, William Carlton, Susan Kapp

    Background: Articulated or hinged ankle-foot orthosis (AFO) allow more range of motion. However, quantitative investigation on articulated AFO is still sparse. Objective: The objective of the study was to quantitatively investigate effects of alignment and joint types on mechanical properties of the thermoplastic articulated AFO. Study design: Tamarack dorsiflexion assist flexure joints with three durometers (75, 85 and 95) and free motion joint were tested. The AFO joint was aligned with the center of the motor shaft (surrogate ankle joint), 10 mm superior, inferior, anterior and posterior with respect to the motor shaft center. Methods: The AFO was passively moved from 20° plantar flexion to 15° dorsiflexion at a speed of 10°/s using a motorized device. Mechanical properties including index of hysteresis, passive resistance torque and quasi-static stiffness (at neutral, 5°, 10° and 15° in plantar flexion) were quantified. Results: Significant effects of joint types and joint alignment on the mechanical properties of an articulated thermoplastic AFO were revealed. Specifically, center alignment showed minimum resistance and stiffness while anterior and posterior alignment showed significantly higher resistance and stiffness. The dorsiflexion assist torques at neutral position ranged from 0.69 ± 0.09 to 1.88 ± 0.10 Nm. Conclusions: Anterior and posterior alignment should be avoided as much as possible. Clinical relevance The current study suggested that anterior and posterior alignment be avoided as much as possible in clinical practice due to potential skin irritation and increase in stress around the ankle joint.