Tomohiro Kaneta

Tomohiro Kaneta

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tomohiro Kaneta has a total of 63 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Image Clarity Paradox: Higher CZT SPECT Contrast Does Not Always Translate to Diagnostic Accuracy for Alzheimer’s Disease

    by Kiyotaka Nemoto, Bryan J. Mathis, Akemi Iwasaka, Kenjiro Nakayama, Tomohiro Kaneta, Tetsuaki Arai

    Background: Recent advances in single-photon emission computed tomography (SPECT) technology, particularly cadmium–zinc–telluride (CZT) detectors, have improved spatial resolution and contrast in cerebral blood flow imaging. This study aimed to investigate whether these improvements translate to enhanced diagnostic accuracy for Alzheimer’s disease (AD). Methods: We compared conventional SPECT (eCAM) with CZT SPECT in 29 patients (mean age 60.9 ± 17.6 years, 69% female) with suspected neurodegenerative diseases. Results: Gray matter/white matter contrast was significantly higher in CZT SPECT compared to eCAM (1.615 ± 0.096 vs. 1.458 ± 0.068, p < 0.001). However, diagnostic accuracy for AD did not improve with CZT SPECT. For the participating psychiatrist, sensitivity decreased from 0.750 (eCAM) to 0.625 (CZT), while for the radiologist, specificity dropped from 0.571 (eCAM) to 0.429 (CZT). Overall accuracy slightly decreased for both readers. Conclusions: These findings suggest that while CZT SPECT offers superior image quality, it may not immediately translate to improved diagnostic accuracy for AD. The study highlights the importance of specialized training for clinicians in interpreting higher-resolution CZT SPECT images to fully leverage their potential in neurodegenerative disease diagnosis. Future research should focus on developing standardized training protocols and larger, multi-center studies to validate these findings.

  • Open Access

    A case report of forensic personal identification by transposed teeth and dental treatment marks using multidetector row computed tomography

    by Yuka Sasaki, Akihito Usui, Hayato Odagiri, Toshihiko Suzuki, Tomohiro Kaneta, Masato Funayama


  • PET and SPECT imaging of the brain: a review on the current status of nuclear medicine in Japan

    by Tomohiro Kaneta

    Radiolabeled tracers allow visualization of not only perfusion, but receptors, function, and metabolism as well. Although spatial resolution is lower than that of computed tomography and magnetic resonance imaging, positron emission tomography (PET) and single photon emission computed tomography (SPECT) have great potential for target-specific imaging. In this review, we discuss several SPECT and PET tracers used in brain imaging, specifically focusing on tracers currently available, or developed, in Japan. Several important and sophisticated methods exist for analysis of brain PET and SPECT images. Two of them, quantitative cerebral blood flow measurement and voxel-based statistical analysis are discussed in this review. The former method, which employs acetazolamide loading, is useful for evaluation of the brain perfusion reserve for ischemic brain diseases. The latter is useful in diagnosing dementing diseases. Additionally, great strides have been made in the development of the technology used in the scanners. New SPECT systems based on cadmium–zinc–telluride, PET/MRI, and semiconductor PET/CT may provide higher spatial resolution with an acquisition time shorter than ever before. Such developments of both tracers and scanners can be integrated for unprecedented imagery of the brain, providing valuable insight into underlying causes of some fatal brain disorders.


  • Open Access

    Early assessment with 18F-2-fluoro-2-deoxyglucose positron emission tomography/computed tomography to predict short-term outcome in clear cell renal carcinoma treated with nivolumab

    by Tadashi Tabei, Noboru Nakaigawa, Tomohiro Kaneta, Ichiro Ikeda, Keiichi Kondo, Kazuhide Makiyama, Hisashi Hasumi, Narihiko Hayashi, Takashi Kawahara, Koji Izumi, et al.

    We reported previously the usefulness of 18F-2-fluoro-2-deoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) to predict prognosis of renal cell carcinoma (RCC) treated with molecular targeted agents. Herein we describe a preliminary research of nine patients who underwent FDG-PET/CT before and after initiation of nivolumab. Patients with metastatic RCC who were treated by nivolumab from October 2016 to March 2017 were enrolled in this study. All patients underwent FDG-PET/CT at baseline and 1 month as a first response assessment, and contrast-enhanced or non-contrast-enhanced CT scan at 4 month as a second response assessment. Logistic regression analysis was performed to assess the association of potential predictors, including age, gender, baseline diameter, baseline maximum standardized uptake value (SUVmax), lung or not lung metastasis, elevation of SUVmax at 1st assessment, and decrease in diameter at 1st assessment with the response at 2nd assessment (decrease in the diameter ≥ 30% or not). There were 9 patients and 30 lesions. Mean days of first assessment with FDG-PET/CT and second assessment by CT scan from initiation of treatment were 32.3 ± 6.4, 115.5 ± 14.9, respectively. Lesions whose diameter decreased ≥30% at second assessment were defined as responding, and lesions whose diameter did not decrease ≥30% were defined as non-responding. There were 18 responding lesions, and 12 non-responding lesions. We compared change in diameter and SUVmax at first assessment with FDG-PET/CT, respectively. All lesions with decreased diameter and elevated SUVmax at first assessment with FDG-PET/CT showed responding at second assessment by CT scan, while most lesions with increased diameter and declined SUVmax at first assessment showed non-responding at second assessment. The multivariate logistic regression analyses revealed that only the elevation of SUVmax at 1 month was an independent predictor (P = 0.025, OR: 13.087, 95%CI: 1.373–124.716). Our findings suggest that the early assessment using FDG-PET/CT can be effective to predict the response of RCC to nivolumab. However, larger prospective studies are needed to confirm these preliminary results. Registered in University Hospital Medical Information Network in JAPAN [ UMIN0000008141 ], registration date: 11 Jun 2012.


  • Open Access

    Use of count-based image reconstruction to evaluate the variability and repeatability of measured standardised uptake values

    by Tomohiro Kaneta, Hiromitsu Daisaki, Matsuyoshi Ogawa, En-Tao Liu, Hitoshi Iizuka, Tetsu Arisawa, Ayako Hino-Shishikura, Keisuke Yoshida, Tomio Inoue

    Standardized uptake values (SUVs) are the most widely used quantitative imaging biomarkers in PET. It is important to evaluate the variability and repeatability of measured SUVs. Phantom studies seem to be essential for this purpose; however, repetitive phantom scanning is not recommended due to the decay of radioactivity. In this study, we performed count-based image reconstruction to avoid the influence of decay using two different PET/CT scanners. By adjusting the ratio of 18F-fluorodeoxyglucose solution to tap water, a NEMA IEC body phantom was set for SUVs of 4.0 inside six hot spheres. The PET data were obtained using two scanners (Aquiduo and Celesteion; Toshiba Medical Systems, Tochigi, Japan). We set the start time for image reconstruction when the total radioactivity in the phantom was 2.53 kBq/cc, and employed the counts of the first 2-min acquisition as the standard. To maintain the number of counts for each image, we set the acquisition time for image reconstruction depending on the decay of radioactivity. We obtained 50 images, and calculated the SUVmax and SUVpeak of all six spheres in each image. The average values of the SUVmax were used to calculate the recovery coefficients to compare those measured by the two different scanners. Bland-Altman analyses of the SUVs measured by the two scanners were also performed. The measured SUVs using the two scanners exhibited a 10–30% difference, and the standard deviation (SD) of the measured SUVs was between 0.1–0.2. The Celesteion always exhibited higher values than the Aquiduo. The smaller sphere exhibited a larger SD, and the SUVpeak had a smaller SD than the SUVmax. The Bland-Altman analyses showed poor agreement between the SUVs measured by the two scanners. The recovery coefficient curves obtained from the two scanners were considerably different. The Celesteion exhibited higher recovery coefficients than the Aquiduo, especially at approximately 20-mm-diameter. Additionally, the curves were lower than those calculated from the standard 30-min acquisition images. We propound count-based image reconstruction to evaluate the variability and repeatability of measured SUVs. These results are also applicable for the standardization and harmonization of SUVs in multi-institutional studies.


    • 1 November 2017
      • Vol. 7  (5) , 204-211

    Variation and repeatability of measured standardized uptake values depending on actual values: a phantom study.

    by Tomohiro Kaneta, Na Sun, Matsuyoshi Ogawa, Hitoshi Iizuka, Tetsu Arisawa, Ayako Hino-Shishikura, Keisuke Yoshida, Tomio Inoue

    Standardized uptake values (SUVs) are the most widely used quantitative imaging biomarkers in positron emission tomography (PET); however, little is known about the changes in variation and repeatability of SUVs depending on the magnitude of the values. We hypothesized that low SUVs have larger variations than high SUVs, and attempted various kinds of experimental PET scans using a phantom. By adjusting the ratio of F-18 solution to tap water, a NEMA IEC body phantom was set for SUVs of 2.0, 4.0, and 8.0 inside six hot spheres. PET data were obtained for 4 hours, and the data reconstructed every 2 min. The SUVmax and SUVpeak of the spheres in all images were recorded. The relative SUVs were calculated by dividing the measured SUV by actual SUV, and used for the Bland-Altman plots. Some variation was observed for the measured SUVs. The measured SUVs for the actual SUV of 2.0 showed the largest variation among those of 2.0, 4.0, and 8.0, and those of 8.0 showed the smallest. Similarly, the relative SUVs showed significantly larger variations for lower values. In addition, the relative SUVmax showed larger variation and value than the relative SUVpeak. The Bland-Altman plots showed considerable variation and little agreement, but the degree of variation decreased as the measured value increased. We demonstrated some variation of the measured SUVs, which decreased for larger measured values. Clinicians should consider the inaccuracy of low SUVs not only in daily practice, but also for multi-institutional studies.


  • Open Access

    Initial evaluation of the Celesteion large-bore PET/CT scanner in accordance with the NEMA NU2-2012 standard and the Japanese guideline for oncology FDG PET/CT data acquisition protocol version 2.0

    by Tomohiro Kaneta, Matsuyoshi Ogawa, Nobutoku Motomura, Hitoshi Iizuka, Tetsu Arisawa, Ayako Hino-Shishikura, Keisuke Yoshida, Tomio Inoue

    The goal of this study was to evaluate the performance of the Celesteion positron emission tomography/computed tomography (PET/CT) scanner, which is characterized by a large-bore and time-of-flight (TOF) function, in accordance with the NEMA NU-2 2012 standard and version 2.0 of the Japanese guideline for oncology fluorodeoxyglucose PET/CT data acquisition protocol. Spatial resolution, sensitivity, count rate characteristic, scatter fraction, energy resolution, TOF timing resolution, and image quality were evaluated according to the NEMA NU-2 2012 standard. Phantom experiments were performed using 18F-solution and an IEC body phantom of the type described in the NEMA NU-2 2012 standard. The minimum scanning time required for the detection of a 10-mm hot sphere with a 4:1 target-to-background ratio, the phantom noise equivalent count (NECphantom), % background variability (N 10mm), % contrast (Q H,10mm), and recovery coefficient (RC) were calculated according to the Japanese guideline. The measured spatial resolution ranged from 4.5- to 5-mm full width at half maximum (FWHM). The sensitivity and scatter fraction were 3.8 cps/kBq and 37.3%, respectively. The peak noise-equivalent count rate was 70 kcps in the presence of 29.6 kBq mL−1 in the phantom. The system energy resolution was 12.4% and the TOF timing resolution was 411 ps at FWHM. Minimum scanning times of 2, 7, 6, and 2 min per bed position, respectively, are recommended for visual score, noise-equivalent count (NEC)phantom, N 10mm, and the Q H,10mm to N 10mm ratio (QNR) by the Japanese guideline. The RC of a 10-mm-diameter sphere was 0.49, which exceeded the minimum recommended value. The Celesteion large-bore PET/CT system had low sensitivity and NEC, but good spatial and time resolution when compared to other PET/CT scanners. The QNR met the recommended values of the Japanese guideline even at 2 min. The Celesteion is therefore thought to provide acceptable image quality with 2 min/bed position acquisition, which is the most common scan protocol in Japan.


  • Open Access

    Head-to-Head Visual Comparison between Brain Perfusion SPECT and Arterial Spin-Labeling MRI with Different Postlabeling Delays in Alzheimer Disease

    by T. Kaneta, O. Katsuse, T. Hirano, M. Ogawa, K. Yoshida, T. Odawara, Y. Hirayasu, T. Inoue

    BACKGROUND AND PURPOSE: Arterial spin-labeling MR imaging has been recently developed as a noninvasive technique with magnetically labeled arterial blood water as an endogenous contrast medium for the evaluation of CBF. Our aim was to compare arterial spin-labeling MR imaging and SPECT in the visual assessment of CBF in patients with Alzheimer disease. MATERIALS AND METHODS: In 33 patients with Alzheimer disease or mild cognitive impairment due to Alzheimer disease, CBF images were obtained by using both arterial spin-labeling–MR imaging with a postlabeling delay of 1.5 seconds and 2.5 seconds (PLD1.5 and PLD2.5, respectively) and brain perfusion SPECT. Twenty-two brain regions were visually assessed, and the diagnostic confidence of Alzheimer disease was recorded. RESULTS: Among all arterial spin-labeling images, 84.9% of PLD1.5 and 9% of PLD2.5 images showed the typical pattern of advanced Alzheimer disease (ie, decreased CBF in the bilateral parietal, temporal, and frontal lobes). PLD1.5, PLD2.5, and SPECT imaging resulted in obviously different visual assessments. PLD1.5 showed a broad decrease in CBF, which could have been due to an early perfusion. In contrast, PLD2.5 did not appear to be influenced by an early perfusion but showed fewer pathologic findings than SPECT. CONCLUSIONS: The distinctions observed by us should be carefully considered in the visual assessments of Alzheimer disease. Further studies are required to define the patterns of change in arterial spin-labeling–MR imaging associated with Alzheimer disease.


  • Open Access

    Voxel-wise correlations between cognition and cerebral blood flow using arterial spin-labeled perfusion MRI in patients with Alzheimer’s disease: a cross-sectional study

    by Tomohiro Kaneta, Omi Katsuse, Takamasa Hirano, Matsuyoshi Ogawa, Ayako Shihikura-Hino, Keisuke Yoshida, Toshinari Odawara, Yoshio Hirayasu, Tomio Inoue

    To analyze voxel-wise correlation between cerebral blood flow (CBF) measured using ASL-MRI and cognition in patients with Alzheimer’s disease (AD). Forty-one patients diagnosed with AD or mild cognitive impairment due to AD were recruited for this study. CBF images were obtained using ASL-MRI (n = 41) with a post-labeling delay (PLD) of 1.5 and 2.5 s (PLD1.5 and PLD2.5, respectively) using a 3 T scanner, in addition to brain perfusion SPECT with N-isopropyl-4-[I-123]iodoamphetamine (n = 28). Voxel-based analyses were performed for ASL-MRI and SPECT using Mini-Mental State Examination (MMSE) scores as covariates. Differences in CBF between PLD1.5 and PLD2.5 were assessed using a paired t-test with SPM12. Significant positive correlations were observed between MMSE scores and CBF at PLD1.5 in the right posterior cingulate cortex (PCC), and both temporo-parietal association cortexes. At PLD2.5, significant positive correlations were determined for MMSE scores and CBF in the superior parietal lobule and the right temporo-parietal association cortex. SPECT showed significant positive correlations in the PCC and both temporo-parietal association cortexes (right-side dominant). PLD1.5 showed significantly higher CBF than PLD2.5 in the proximal areas of vascular territories of the anterior, middle, and posterior cerebral arteries. Significant positive correlations in CBF, measured with both ASL-MRI and SPECT, with cognition were found in the PCC and temporo-parietal association cortexes. PLD1.5 and PLD2.5 showed similar correlations with cognition, although the CBF images had significant differences.


  • Differences in sodium fluoride-18 uptake in the normal skeleton depending on the location and characteristics of the bone

    by Shintaro Nawata, Matsuyoshi Ogawa, Yoshinobu Ishiwata, Naomi Kobayashi, Ayako Shishikura-Hino, Keisuke Yoshida, Yutaka Inaba, Tomoyuki Saito, Tomio Inoue, Tomohiro Kaneta

    Aim: The aim of this study was to evaluate the normal distribution of sodium fluoride-18 (NaF-18) and to clarify the differences in uptake according to location and the type of the bone using positron emission tomography (PET) / computed tomography (CT). Methods: We retrospectively reviewed NaF-18 PET/CT images from 30 patients with hip joint disorders. PET/CT scans were performed 40 min after injection of approximately 185 MBq of NaF-18. To evaluate the relationship between the distribution of NaF-18 uptake and bone density, we compared the maximum standardised uptake values (SUVmax) on PET and the Hounsfield Units (HUs) on CT of the lumbar vertebra, ilium, and proximal and distal femurs. Regions of interests were defined both outside and inside the cortical bone to measure whole bone and cancellous bone only, respectively. Results: The distribution of NaF-18 differed according to the skeletal site. The lumbar vertebra showed the highest SUVmax for both whole bone and cancellous bone, followed by the ilium, proximal femur, and distal femur. The bones differed significantly in SUVmax. The distal femur showed the highest HU, followed by the proximal femur, ilium, and vertebra. Profile curve analyses demonstrated that the cancellous bones showed higher SUVmax and lower HU than the cortical bones. Conclusions: Our results demonstrate the difference in NaF-18 uptake between cancellous and cortical bones, which may explain differences in uptake by location. NaF-18 uptake does not appear to be strongly correlated with bone density, but rather with bone turnover and blood flow.