Muhammad Aamir
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Muhammad Aamir has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Saad Mekhilef
Swinburne University of Technology
3 shared publications Kafeel Ahmed Kalwar
2 shared publicationsAbida Shaheen
1 shared publicationAbu Buker
1 shared publication- Asad Waqar
Bahria University,Department of Electrical Engineering,Islamabad,Pakistan
1 shared publication - Azhar Ul-Haq
Department of Electrical Engineering, College of EME, National University of Sciences and Technology (NUST), Islamabad, Pakistan
1 shared publication
Latest Publications
- 20 November 2026
- Published by Elsevier in Journal of Power Sources
- Vol. 700
Performance improvement of lead-acid battery capacity testing using machine learning-based early prediction
- 20 November 2026
- Published by Elsevier in Journal of Power Sources
- Vol. 700
Performance improvement of lead-acid battery capacity testing using machine learning-based early prediction
- Open Access
- 18 May 2023
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 2 (3) , 100794
C-9 | Outcomes of Extracorporeal Membrane Oxygenation in COVID-19: Updated Meta-Analysis
- 18 May 2023
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 2 (3) , 100794
Open AccessC-9 | Outcomes of Extracorporeal Membrane Oxygenation in COVID-19: Updated Meta-Analysis
- Open Access
- 6 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 60177-60188
Second-Order Rotating Sliding Mode Control With Composite Reaching Law for Two Level Single Phase Voltage Source Inverters
In the recent past, the integration of distributed generation via power electronic interface like voltage source inverter (VSI) allows attaining the desired voltage quality by adopting appropriate control law. This paper presents sliding mode control (SMC) with composite reaching law technique for regulating output voltage under variable load conditions for single phase VSI. Inherent properties of SMC like robustness are achieved usually at the cost of chattering along the sliding surface. To handle this trade-off, optimal sliding surface selection mechanism is applied with adoptive reaching law based on state variables magnitude to set the value of control gain. The novelty of the proposed technique is related to composite reaching law that overcomes constraints associated with SMC. The proposed reaching law is a combination of exponential, power, and difference function. The intelligent mix of these functions makes the suggested reaching law more effective in achieving a high-speed convergence rate of system states and significant chattering reduction. Moreover, the sliding surface is chosen using a time-varying slope based on error variables. Comparative study of SMC with cosine exponential reaching law (Cos-ERL) results, fractional power rate reaching law (FPRRL) and proposed composite reaching law with rotating sliding surface(C-RL-RSS) applied on single phase voltage source inverter under variable load conditions validates the effectiveness of the proposed C-RL-RSS based SMC. It is revealed that the proposed C-RL-RSS based SMC is proficient in achieving very low %THD in the output voltage along with reduced chattering and minimum tracking time.
- 6 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 60177-60188
Open AccessSecond-Order Rotating Sliding Mode Control With Composite Reaching Law for Two Level Single Phase Voltage Source Inverters
In the recent past, the integration of distributed generation via power electronic interface like voltage source inverter (VSI) allows attaining the desired voltage quality by adopting appropriate control law. This paper presents sliding mode control (SMC) with composite reaching law technique for regulating output voltage under variable load conditions for single phase VSI. Inherent properties of SMC like robustness are achieved usually at the cost of chattering along the sliding surface. To handle this trade-off, optimal sliding surface selection mechanism is applied with adoptive reaching law based on state variables magnitude to set the value of control gain. The novelty of the proposed technique is related to composite reaching law that overcomes constraints associated with SMC. The proposed reaching law is a combination of exponential, power, and difference function. The intelligent mix of these functions makes the suggested reaching law more effective in achieving a high-speed convergence rate of system states and significant chattering reduction. Moreover, the sliding surface is chosen using a time-varying slope based on error variables. Comparative study of SMC with cosine exponential reaching law (Cos-ERL) results, fractional power rate reaching law (FPRRL) and proposed composite reaching law with rotating sliding surface(C-RL-RSS) applied on single phase voltage source inverter under variable load conditions validates the effectiveness of the proposed C-RL-RSS based SMC. It is revealed that the proposed C-RL-RSS based SMC is proficient in achieving very low %THD in the output voltage along with reduced chattering and minimum tracking time.
- Open Access
- 30 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 26676-26700
Comparative Analysis of Photovoltaic Faults and Performance Evaluation of its Detection Techniques
Faults detection and analysis in PV system are considered critical for ensuring safety and increasing output power of PV arrays. PV faults do not only reduce output power and efficiency but also lessen the working life time of a system. Most common and chronic PV faults are line to line, line to ground, shadowing fault, and arc fault while less common and acute faults are hotspot, degradation, bypass diode, and connection faults. Event of PV fault detection failures, such as most recent in Mount Holly, USA in 2011 evinced the improvement in current fault detection and mitigation techniques to shrink such failures. There are various limitations in the existing fault detection techniques, as identified in this paper, which may cause misdetection of the faults. This paper is focused on mathematical formulation of various PV faults and lead to the latter’s critical analysis in terms of efficiency, accuracy, complexity, and reliability. The presented work also helps to identify nature and causes of occurrence of a PV fault. This research work serves as a special set of references and recommendations for researchers and PV manufacturing industry to improve fault detection prospects in solar PV systems.
- 30 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 26676-26700
Open AccessComparative Analysis of Photovoltaic Faults and Performance Evaluation of its Detection Techniques
Faults detection and analysis in PV system are considered critical for ensuring safety and increasing output power of PV arrays. PV faults do not only reduce output power and efficiency but also lessen the working life time of a system. Most common and chronic PV faults are line to line, line to ground, shadowing fault, and arc fault while less common and acute faults are hotspot, degradation, bypass diode, and connection faults. Event of PV fault detection failures, such as most recent in Mount Holly, USA in 2011 evinced the improvement in current fault detection and mitigation techniques to shrink such failures. There are various limitations in the existing fault detection techniques, as identified in this paper, which may cause misdetection of the faults. This paper is focused on mathematical formulation of various PV faults and lead to the latter’s critical analysis in terms of efficiency, accuracy, complexity, and reliability. The presented work also helps to identify nature and causes of occurrence of a PV fault. This research work serves as a special set of references and recommendations for researchers and PV manufacturing industry to improve fault detection prospects in solar PV systems.
- 1 March 2018
- Published by Elsevier in Measurement
- Vol. 118, 237-245
A design method for developing a high misalignment tolerant wireless charging system for electric vehicles
- 1 March 2018
- Published by Elsevier in Measurement
- Vol. 118, 237-245
A design method for developing a high misalignment tolerant wireless charging system for electric vehicles
- Open Access
- 30 April 2017
- Published by NADIA in International Journal of Control and Automation
- Vol. 10 (4) , 71-84
Motion Simulation Table Control Using Improved ZPETC Approach
- 30 April 2017
- Published by NADIA in International Journal of Control and Automation
- Vol. 10 (4) , 71-84
Open AccessMotion Simulation Table Control Using Improved ZPETC Approach
- 1 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2289-2295
New single stage AC/DC converter with high frequency link isolation for high power application
Single stage AC/DC converter with DC isolation has wide industrial applications such as electric vehicles battery charging, home appliances etc. Unlike the existing single stage AC/DC converter operating in discontinuous conduction mode (DCM), a new single stage AC/DC converter with minimum semiconductor count, operating in continuous conduction mode (CCM) has been presented for high power applications. The proposed AC/DC converter integrates the half bridge pulse width modulation (PWM) rectifier with PWM half bridge DC/DC converter. AC/DC converter operating in continuous conduction mode (CCM), with high input power factor, and least semiconductor devices count reduces the conduction losses of the circuit considerable. All the switches operate under zero voltage switching (ZVS) condition, results in reducing the switching losses, EMI losses, and increase the overall efficiency of the circuit. Finally 800W experimental prototype has been designed to verify the theoretical analysis and performance of the circuit.
- 1 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2289-2295
New single stage AC/DC converter with high frequency link isolation for high power application
Single stage AC/DC converter with DC isolation has wide industrial applications such as electric vehicles battery charging, home appliances etc. Unlike the existing single stage AC/DC converter operating in discontinuous conduction mode (DCM), a new single stage AC/DC converter with minimum semiconductor count, operating in continuous conduction mode (CCM) has been presented for high power applications. The proposed AC/DC converter integrates the half bridge pulse width modulation (PWM) rectifier with PWM half bridge DC/DC converter. AC/DC converter operating in continuous conduction mode (CCM), with high input power factor, and least semiconductor devices count reduces the conduction losses of the circuit considerable. All the switches operate under zero voltage switching (ZVS) condition, results in reducing the switching losses, EMI losses, and increase the overall efficiency of the circuit. Finally 800W experimental prototype has been designed to verify the theoretical analysis and performance of the circuit.
- 1 May 2016
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 58, 1395-1410
Review: Uninterruptible Power Supply (UPS) system
- 1 May 2016
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 58, 1395-1410
Review: Uninterruptible Power Supply (UPS) system