Allen F. Jordan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Allen F. Jordan has a total of 201 co-authors. Here are the top co-authors by number of shared publications:
- Dale F. Hurst
Cooperative Institute for Research in Environmental Sciences, University of Colorado Boulder, Boulder, CO 80309, USA
16 shared publications - Emrys Hall
NOAA Global Monitoring Laboratory, 325 Broadway, Boulder, CO, 80305, USA
15 shared publications Bryan J. Johnson
Global Monitoring Division, NOAA/ESRL, Boulder, Colorado, USA
6 shared publications- Anne Mee Thompson
Earth Sciences Division, NASA Goddard Space Flight Center, Greenbelt, Maryland, USA
5 shared publications - Jacquelyn Cecile Witte
National Center for Atmospheric Research
5 shared publications - Samuel J. Oltmans
Global Monitoring Laboratory Earth System Research Laboratory, NOAA, Boulder, CO, 80305 USA
5 shared publications
Latest Publications
- Open Access
- 28 March 2022
- Published by Copernicus GmbH
Stratospheric Aerosol and Gas Experiment III on the International Space Station(SAGE III/ISS): Continuing the Legacy of SAGE Data Products
The Stratospheric Aerosol and Gas Experiment III (SAGE III) instrument installed on the International Space Station (ISS) has completed almost half of a decade of data collection and production of science data products. The SAGE III/ISS is a solar and lunar occultation instrument that scans the light from the Sun and Moon through the limb of the Earth’s atmosphere to produce vertical profiles of aerosol, ozone, water vapor, and other trace gases. It continues the legacy of previous SAGE instruments dating back to the 1970s to provide data continuity of stratospheric constituents critical for assessing trends in the ozone layer. This presentation shows how SAGE III/ISS aerosol and gas vertical profiles continue to benefit a worldwide database of in situ and satellite data for climate observation.
- 28 March 2022
- Published by Copernicus GmbH
Open AccessStratospheric Aerosol and Gas Experiment III on the International Space Station(SAGE III/ISS): Continuing the Legacy of SAGE Data Products
The Stratospheric Aerosol and Gas Experiment III (SAGE III) instrument installed on the International Space Station (ISS) has completed almost half of a decade of data collection and production of science data products. The SAGE III/ISS is a solar and lunar occultation instrument that scans the light from the Sun and Moon through the limb of the Earth’s atmosphere to produce vertical profiles of aerosol, ozone, water vapor, and other trace gases. It continues the legacy of previous SAGE instruments dating back to the 1970s to provide data continuity of stratospheric constituents critical for assessing trends in the ozone layer. This presentation shows how SAGE III/ISS aerosol and gas vertical profiles continue to benefit a worldwide database of in situ and satellite data for climate observation.
- Open Access
- 21 October 2021
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 14 (10) , 6795-6819
UAS Chromatograph for Atmospheric Trace Species (UCATS) – a versatile instrument for trace gas measurements on airborne platforms
UCATS (the UAS Chromatograph for Atmospheric Trace Species) was designed and built for observations of important atmospheric trace gases from unmanned aircraft systems (UAS) in the upper troposphere and lower stratosphere (UTLS). Initially it measured major chlorofluorocarbons (CFCs) and the stratospheric transport tracers nitrous oxide (N2O) and sulfur hexafluoride (SF6), using gas chromatography with electron capture detection. Compact commercial absorption spectrometers for ozone (O3) and water vapor (H2O) were added to enhance its capabilities on platforms with relatively small payloads. UCATS has since been reconfigured to measure methane (CH4), carbon monoxide (CO), and molecular hydrogen (H2) instead of CFCs and has undergone numerous upgrades to its subsystems. It has served as part of large payloads on stratospheric UAS missions to probe the tropical tropopause region and transport of air into the stratosphere; in piloted aircraft studies of greenhouse gases, transport, and chemistry in the troposphere; and in 2021 is scheduled to return to the study of stratospheric ozone and halogen compounds, one of its original goals. Each deployment brought different challenges, which were largely met or resolved. The design, capabilities, modifications, and some results from UCATS are shown and described here, including changes for future missions.
- 21 October 2021
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 14 (10) , 6795-6819
Open AccessUAS Chromatograph for Atmospheric Trace Species (UCATS) – a versatile instrument for trace gas measurements on airborne platforms
UCATS (the UAS Chromatograph for Atmospheric Trace Species) was designed and built for observations of important atmospheric trace gases from unmanned aircraft systems (UAS) in the upper troposphere and lower stratosphere (UTLS). Initially it measured major chlorofluorocarbons (CFCs) and the stratospheric transport tracers nitrous oxide (N2O) and sulfur hexafluoride (SF6), using gas chromatography with electron capture detection. Compact commercial absorption spectrometers for ozone (O3) and water vapor (H2O) were added to enhance its capabilities on platforms with relatively small payloads. UCATS has since been reconfigured to measure methane (CH4), carbon monoxide (CO), and molecular hydrogen (H2) instead of CFCs and has undergone numerous upgrades to its subsystems. It has served as part of large payloads on stratospheric UAS missions to probe the tropical tropopause region and transport of air into the stratosphere; in piloted aircraft studies of greenhouse gases, transport, and chemistry in the troposphere; and in 2021 is scheduled to return to the study of stratospheric ozone and halogen compounds, one of its original goals. Each deployment brought different challenges, which were largely met or resolved. The design, capabilities, modifications, and some results from UCATS are shown and described here, including changes for future missions.
- Open Access
- 16 February 2021
- Published by Copernicus GmbH
- p. 1-30
Comment on amt-2020-496
UCATS (the UAS Chromatograph for Atmospheric Trace Species) was designed and built for observations of important atmospheric trace gases from unmanned aircraft systems (UAS) in the upper troposphere and lower stratosphere (UT/LS). Initially it measured major chlorofluorocarbons (CFCs) and the stratospheric transport tracers nitrous oxide (N2O) and sulfur hexafluoride (SF6), using gas chromatography with electron capture detection. Compact ozone (O3) and water vapor (H2O) instruments were added to enhance science missions on platforms with relatively small payloads. Over the past decade, UCATS has been reconfigured to measure methane (CH4), carbon monoxide (CO), and molecular hydrogen (H2) instead of CFCs and has undergone numerous upgrades to its subsystems. It has served as part of large payloads on stratospheric UAS missions to probe the tropical tropopause region and transport of air into the stratosphere, in piloted aircraft studies of greenhouse gases, transport, and chemistry in the troposphere, and will soon return to the study of stratospheric ozone depletion, one of the original goals for UCATS. Each deployment brought different challenges, which were largely met or resolved. The design, capabilities, modifications and some results from UCATS are shown and described here, including changes for upcoming missions.
- 16 February 2021
- Published by Copernicus GmbH
- p. 1-30
Open AccessComment on amt-2020-496
UCATS (the UAS Chromatograph for Atmospheric Trace Species) was designed and built for observations of important atmospheric trace gases from unmanned aircraft systems (UAS) in the upper troposphere and lower stratosphere (UT/LS). Initially it measured major chlorofluorocarbons (CFCs) and the stratospheric transport tracers nitrous oxide (N2O) and sulfur hexafluoride (SF6), using gas chromatography with electron capture detection. Compact ozone (O3) and water vapor (H2O) instruments were added to enhance science missions on platforms with relatively small payloads. Over the past decade, UCATS has been reconfigured to measure methane (CH4), carbon monoxide (CO), and molecular hydrogen (H2) instead of CFCs and has undergone numerous upgrades to its subsystems. It has served as part of large payloads on stratospheric UAS missions to probe the tropical tropopause region and transport of air into the stratosphere, in piloted aircraft studies of greenhouse gases, transport, and chemistry in the troposphere, and will soon return to the study of stratospheric ozone depletion, one of the original goals for UCATS. Each deployment brought different challenges, which were largely met or resolved. The design, capabilities, modifications and some results from UCATS are shown and described here, including changes for upcoming missions.
- Open Access
- 25 January 2021
- Published by Copernicus GmbH in EGUsphere
- Vol. 2021, 1-30
UAS Chromatograph for Atmospheric Trace Species (UCATS) – a versatile instrument for trace gas measurements on airborne platforms
UCATS (the UAS Chromatograph for Atmospheric Trace Species) was designed and built for observations of important atmospheric trace gases from unmanned aircraft systems (UAS) in the upper troposphere and lower stratosphere (UT/LS). Initially it measured major chlorofluorocarbons (CFCs) and the stratospheric transport tracers nitrous oxide (N2O) and sulfur hexafluoride (SF6), using gas chromatography with electron capture detection. Compact ozone (O3) and water vapor (H2O) instruments were added to enhance science missions on platforms with relatively small payloads. Over the past decade, UCATS has been reconfigured to measure methane (CH4), carbon monoxide (CO), and molecular hydrogen (H2) instead of CFCs and has undergone numerous upgrades to its subsystems. It has served as part of large payloads on stratospheric UAS missions to probe the tropical tropopause region and transport of air into the stratosphere, in piloted aircraft studies of greenhouse gases, transport, and chemistry in the troposphere, and will soon return to the study of stratospheric ozone depletion, one of the original goals for UCATS. Each deployment brought different challenges, which were largely met or resolved. The design, capabilities, modifications and some results from UCATS are shown and described here, including changes for upcoming missions.
- 25 January 2021
- Published by Copernicus GmbH in EGUsphere
- Vol. 2021, 1-30
Open AccessUAS Chromatograph for Atmospheric Trace Species (UCATS) – a versatile instrument for trace gas measurements on airborne platforms
UCATS (the UAS Chromatograph for Atmospheric Trace Species) was designed and built for observations of important atmospheric trace gases from unmanned aircraft systems (UAS) in the upper troposphere and lower stratosphere (UT/LS). Initially it measured major chlorofluorocarbons (CFCs) and the stratospheric transport tracers nitrous oxide (N2O) and sulfur hexafluoride (SF6), using gas chromatography with electron capture detection. Compact ozone (O3) and water vapor (H2O) instruments were added to enhance science missions on platforms with relatively small payloads. Over the past decade, UCATS has been reconfigured to measure methane (CH4), carbon monoxide (CO), and molecular hydrogen (H2) instead of CFCs and has undergone numerous upgrades to its subsystems. It has served as part of large payloads on stratospheric UAS missions to probe the tropical tropopause region and transport of air into the stratosphere, in piloted aircraft studies of greenhouse gases, transport, and chemistry in the troposphere, and will soon return to the study of stratospheric ozone depletion, one of the original goals for UCATS. Each deployment brought different challenges, which were largely met or resolved. The design, capabilities, modifications and some results from UCATS are shown and described here, including changes for upcoming missions.
- Open Access
- 12 February 2019
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 19 (3) , 1853-1865
Detection and classification of laminae in balloon-borne ozonesonde profiles: application to the long-term record from Boulder, Colorado
We quantify ozone variability in the upper troposphere and lower stratosphere (UTLS) by investigating lamination features in balloon measurements of ozone mixing ratio and potential temperature. Laminae are defined as stratified variations in ozone that meet or exceed a 10 % threshold for deviations from a basic state vertical profile of ozone. The basic state profiles are derived for each sounding using smoothing methods applied within a vertical coordinate system relative to the World Meteorological Organization (WMO) tropopause. We present results of this analysis for the 25-year record of ozonesonde measurements from Boulder, Colorado. The mean number of ozone laminae identified per sounding is about 9±2 (1 σ ). The root-mean-square relative amplitude is 20 %, and laminae with much larger amplitudes (>40 %) are seen in ∼ 2 % of the profiles. The vertical scale of detected ozone laminae typically ranges between 0.5 and 1.2 km. The lamina occurrence frequency varies significantly with altitude and is largest within ∼2 km of the tropopause. Overall, ozone laminae identified in our analysis account for more than one-third of the total intra-seasonal variability in ozone. A correlation technique between ozone and potential temperature is used to classify the subset of ozone laminae that are associated with gravity wave (GW) phenomena, which accounts for 28 % of all laminar ozone features. The remaining 72 % of laminae arise from non-gravity wave (NGW) phenomena. There are differences in both the vertical distribution and seasonality of GW versus NGW ozone laminae that are linked to the contrast in main generating mechanisms for each laminae type.
- 12 February 2019
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 19 (3) , 1853-1865
Open AccessDetection and classification of laminae in balloon-borne ozonesonde profiles: application to the long-term record from Boulder, Colorado
We quantify ozone variability in the upper troposphere and lower stratosphere (UTLS) by investigating lamination features in balloon measurements of ozone mixing ratio and potential temperature. Laminae are defined as stratified variations in ozone that meet or exceed a 10 % threshold for deviations from a basic state vertical profile of ozone. The basic state profiles are derived for each sounding using smoothing methods applied within a vertical coordinate system relative to the World Meteorological Organization (WMO) tropopause. We present results of this analysis for the 25-year record of ozonesonde measurements from Boulder, Colorado. The mean number of ozone laminae identified per sounding is about 9±2 (1 σ ). The root-mean-square relative amplitude is 20 %, and laminae with much larger amplitudes (>40 %) are seen in ∼ 2 % of the profiles. The vertical scale of detected ozone laminae typically ranges between 0.5 and 1.2 km. The lamina occurrence frequency varies significantly with altitude and is largest within ∼2 km of the tropopause. Overall, ozone laminae identified in our analysis account for more than one-third of the total intra-seasonal variability in ozone. A correlation technique between ozone and potential temperature is used to classify the subset of ozone laminae that are associated with gravity wave (GW) phenomena, which accounts for 28 % of all laminar ozone features. The remaining 72 % of laminae arise from non-gravity wave (NGW) phenomena. There are differences in both the vertical distribution and seasonality of GW versus NGW ozone laminae that are linked to the contrast in main generating mechanisms for each laminae type.
- Open Access
- 8 February 2019
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 12 (2) , 873-890
Tropospheric water vapor profiles obtained with FTIR: comparison with balloon-borne frost point hygrometers and influence on trace gas retrievals
Retrievals of vertical profiles of key atmospheric gases provide a critical long-term record from ground-based Fourier transform infrared (FTIR) solar absorption measurements. However, the characterization of the retrieved vertical profile structure can be difficult to validate, especially for gases with large vertical gradients and spatial–temporal variability such as water vapor. In this work, we evaluate the accuracy of the most common water vapor isotope (H216O, hereafter WV) FTIR retrievals in the lower and upper troposphere–lower stratosphere. Coincident high-quality vertically resolved WV profile measurements obtained from 2010 to 2016 with balloon-borne NOAA frost point hygrometers (FPHs) are used as reference to evaluate the performance of the retrieved profiles at two sites: Boulder (BLD), Colorado, and at the mountaintop observatory of Mauna Loa (MLO), Hawaii. For a meaningful comparison, the spatial–temporal variability has been investigated. We present results of comparisons among FTIR retrievals with unsmoothed and smoothed FPH profiles to assess WV vertical gradients. Additionally, we evaluate the quantitative impact of different a priori profiles in the retrieval of WV. An orthogonal linear regression analysis shows the best correlation among tropospheric layers using ERA-Interim (ERA-I) a priori profiles and biases are lower for unsmoothed comparisons. In Boulder, we found a negative bias of 0.02±1.9 % (r = 0.95) for the 1.5–3 km layer. A larger negative bias of 11.1±3.5 % (r = 0.97) was found in the lower free troposphere layer of 3–5 km attributed to rapid vertical change of WV, which is not always captured by the retrievals. The bias improves in the 5–7.5 km layer (1.0±5.3 %, r = 0.94). The bias remains at about 13 % for layers above 7.5 km but below 13.5 km. At MLO the spatial mismatch is significantly larger due to the launch of the sonde being farther from the FTIR location. Nevertheless, we estimate a negative bias of 5.9±4.6 % (r = 0.93) for the 3.5–5.5 km layer and 9.9±3.7 % (r = 0.93) for the 5.5–7.5 km layer, and we measure positive biases of 6.2±3.6 % (r = 0.95) for the 7.5–10 km layer and 12.6 % and greater values above 10 km. The agreement for the first layer is significantly better at BLD because the air masses are similar for both FTIR and FPH. Furthermore, for the first time we study the influence of different WV a priori profiles in the retrieval of selected gas profiles. Using NDACC standard retrievals we present results for hydrogen cyanide (HCN), carbon monoxide (CO), and ethane (C2H6) by taking NOAA FPH profiles as the ground truth and evaluating the impact of other WV profiles. We show that the effect is minor for C2H6 (bias < 0.5 % for all WV sources) among all vertical layers. However, for HCN we found significant biases between 6 % for layers close to the surface and 2 % for the upper troposphere depending on the WV profile source. The best results (reduced bias and precision and r values closer to unity) are always found for pre-retrieved WV. Therefore, we recommend first retrieving WV to use in subsequent retrieval of gases.
- 8 February 2019
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 12 (2) , 873-890
Open AccessTropospheric water vapor profiles obtained with FTIR: comparison with balloon-borne frost point hygrometers and influence on trace gas retrievals
Retrievals of vertical profiles of key atmospheric gases provide a critical long-term record from ground-based Fourier transform infrared (FTIR) solar absorption measurements. However, the characterization of the retrieved vertical profile structure can be difficult to validate, especially for gases with large vertical gradients and spatial–temporal variability such as water vapor. In this work, we evaluate the accuracy of the most common water vapor isotope (H216O, hereafter WV) FTIR retrievals in the lower and upper troposphere–lower stratosphere. Coincident high-quality vertically resolved WV profile measurements obtained from 2010 to 2016 with balloon-borne NOAA frost point hygrometers (FPHs) are used as reference to evaluate the performance of the retrieved profiles at two sites: Boulder (BLD), Colorado, and at the mountaintop observatory of Mauna Loa (MLO), Hawaii. For a meaningful comparison, the spatial–temporal variability has been investigated. We present results of comparisons among FTIR retrievals with unsmoothed and smoothed FPH profiles to assess WV vertical gradients. Additionally, we evaluate the quantitative impact of different a priori profiles in the retrieval of WV. An orthogonal linear regression analysis shows the best correlation among tropospheric layers using ERA-Interim (ERA-I) a priori profiles and biases are lower for unsmoothed comparisons. In Boulder, we found a negative bias of 0.02±1.9 % (r = 0.95) for the 1.5–3 km layer. A larger negative bias of 11.1±3.5 % (r = 0.97) was found in the lower free troposphere layer of 3–5 km attributed to rapid vertical change of WV, which is not always captured by the retrievals. The bias improves in the 5–7.5 km layer (1.0±5.3 %, r = 0.94). The bias remains at about 13 % for layers above 7.5 km but below 13.5 km. At MLO the spatial mismatch is significantly larger due to the launch of the sonde being farther from the FTIR location. Nevertheless, we estimate a negative bias of 5.9±4.6 % (r = 0.93) for the 3.5–5.5 km layer and 9.9±3.7 % (r = 0.93) for the 5.5–7.5 km layer, and we measure positive biases of 6.2±3.6 % (r = 0.95) for the 7.5–10 km layer and 12.6 % and greater values above 10 km. The agreement for the first layer is significantly better at BLD because the air masses are similar for both FTIR and FPH. Furthermore, for the first time we study the influence of different WV a priori profiles in the retrieval of selected gas profiles. Using NDACC standard retrievals we present results for hydrogen cyanide (HCN), carbon monoxide (CO), and ethane (C2H6) by taking NOAA FPH profiles as the ground truth and evaluating the impact of other WV profiles. We show that the effect is minor for C2H6 (bias < 0.5 % for all WV sources) among all vertical layers. However, for HCN we found significant biases between 6 % for layers close to the surface and 2 % for the upper troposphere depending on the WV profile source. The best results (reduced bias and precision and r values closer to unity) are always found for pre-retrieved WV. Therefore, we recommend first retrieving WV to use in subsequent retrieval of gases.
- Open Access
- 17 October 2018
- Published by Copernicus GmbH in EGUsphere
- Vol. 2018, 1-26
Tropospheric water vapor profiles obtained with FTIR: comparison with balloon-borne frost point hygrometers and influence on trace gas retrievals
Retrievals of vertical profiles of key atmospheric gases provide a critical long-term data record from ground-based Fourier Transform InfraRed (FTIR) solar absorption measurements. However, the characterization of the retrieved vertical profile structure can be difficult to validate, especially for gases with large vertical gradients and spatial-temporal variability such as water vapor. In this work, we evaluate the accuracy of the most common water vapor isotope (H216O, hereafter WV) FTIR retrievals in the lower and upper troposphere – lower stratosphere. Coincident high-quality vertically resolved WV profile measurements obtained from 2010 to 2016 with balloon-borne NOAA Frost Point Hygrometers (FPH) are used as reference to evaluate the performance of the retrieved profiles at two sites: Boulder, Colorado and in the mountain top observatory of Mauna Loa, Hawaii. For a meaningful comparison, the spatial-temporal variability has been investigated. Additionally, we evaluate the quantitative impact of different a priori profiles in the retrieval of WV vertical profiles using un-smoothed comparisons. An orthogonal linear regression analysis shows the best correlation among all layers using ERA-Interim (ERA-I) a priori profiles. In Boulder, we found a negative bias of 0.02 ± 1.9 % and precision of 3.7 % (r = 0.95) for the 1.5–3 km layer. A larger negative bias of 11.1 ± 3.5 % and precision of 7.0 % was found in the lower free troposphere layer of 3–5 km (r = 0.97) attributed to rapid vertical change of WV, which is not always captured by the retrievals. The bias improves in the 5–7.5 km layer (1.0 ± 5.3 %) and the precision worsens to about 10 %. The bias remains at about 13 % and the precision remains to about 10 % for layers above 7.5 km but below 13.5 km. At MLO the spatial mismatch is significantly larger due to the launch of the sonde being farther from the FTIR location. Nevertheless, we estimate a negative biases of 5.9 ± 4.6 % for the 3.5–5.5 km layer (r = 0.93) and 9.9 ± 3.7 % for the 5.5–7.5 km layer (r = 0.93), and positive biases of 6.2 ± 3.6 % for the 7.5–10 km layer (r = 0.95), and 12.6 % and greater values above 10 km. The agreement for the first layer is significantly better at BLD likely that the air masses are similar for both FTIR and FPH. Furthermore, for the first time we study the influence of different sources of WV profiles in the retrieval of selected gas profiles. Using NDACC standard retrievals we present results for hydrogen cyanide (HCN), carbon monoxide (CO), and ethane (C2H6) by taking NOAA FPH profiles as the ground-truth and evaluate the impact of other WV profile sources. We show that the effect is minor for C2H6 (bias < 0.5 % for all WV sources) among all vertical layers. However, for HCN we found significant biases between 6 % for layers close to the surface to 2 % for upper troposphere depending on WV profile source. The best results (lowest bias/precision and r-values closer to unity) are always found for pre-retrieved WV. Therefore, we recommend to first retrieve WV to use in subsequent retrieval of gases.
- 17 October 2018
- Published by Copernicus GmbH in EGUsphere
- Vol. 2018, 1-26
Open AccessTropospheric water vapor profiles obtained with FTIR: comparison with balloon-borne frost point hygrometers and influence on trace gas retrievals
Retrievals of vertical profiles of key atmospheric gases provide a critical long-term data record from ground-based Fourier Transform InfraRed (FTIR) solar absorption measurements. However, the characterization of the retrieved vertical profile structure can be difficult to validate, especially for gases with large vertical gradients and spatial-temporal variability such as water vapor. In this work, we evaluate the accuracy of the most common water vapor isotope (H216O, hereafter WV) FTIR retrievals in the lower and upper troposphere – lower stratosphere. Coincident high-quality vertically resolved WV profile measurements obtained from 2010 to 2016 with balloon-borne NOAA Frost Point Hygrometers (FPH) are used as reference to evaluate the performance of the retrieved profiles at two sites: Boulder, Colorado and in the mountain top observatory of Mauna Loa, Hawaii. For a meaningful comparison, the spatial-temporal variability has been investigated. Additionally, we evaluate the quantitative impact of different a priori profiles in the retrieval of WV vertical profiles using un-smoothed comparisons. An orthogonal linear regression analysis shows the best correlation among all layers using ERA-Interim (ERA-I) a priori profiles. In Boulder, we found a negative bias of 0.02 ± 1.9 % and precision of 3.7 % (r = 0.95) for the 1.5–3 km layer. A larger negative bias of 11.1 ± 3.5 % and precision of 7.0 % was found in the lower free troposphere layer of 3–5 km (r = 0.97) attributed to rapid vertical change of WV, which is not always captured by the retrievals. The bias improves in the 5–7.5 km layer (1.0 ± 5.3 %) and the precision worsens to about 10 %. The bias remains at about 13 % and the precision remains to about 10 % for layers above 7.5 km but below 13.5 km. At MLO the spatial mismatch is significantly larger due to the launch of the sonde being farther from the FTIR location. Nevertheless, we estimate a negative biases of 5.9 ± 4.6 % for the 3.5–5.5 km layer (r = 0.93) and 9.9 ± 3.7 % for the 5.5–7.5 km layer (r = 0.93), and positive biases of 6.2 ± 3.6 % for the 7.5–10 km layer (r = 0.95), and 12.6 % and greater values above 10 km. The agreement for the first layer is significantly better at BLD likely that the air masses are similar for both FTIR and FPH. Furthermore, for the first time we study the influence of different sources of WV profiles in the retrieval of selected gas profiles. Using NDACC standard retrievals we present results for hydrogen cyanide (HCN), carbon monoxide (CO), and ethane (C2H6) by taking NOAA FPH profiles as the ground-truth and evaluate the impact of other WV profile sources. We show that the effect is minor for C2H6 (bias < 0.5 % for all WV sources) among all vertical layers. However, for HCN we found significant biases between 6 % for layers close to the surface to 2 % for upper troposphere depending on WV profile source. The best results (lowest bias/precision and r-values closer to unity) are always found for pre-retrieved WV. Therefore, we recommend to first retrieve WV to use in subsequent retrieval of gases.
- Open Access
- 4 October 2018
- Published by Copernicus GmbH in EGUsphere
- Vol. 2018, 1-25
Detection and Classification of Laminae in Balloon-borne Ozonesonde Profiles: Application to the Long Term Record from Boulder, Colorado
We quantify ozone variability in the upper troposphere and lower stratosphere (UTLS) by investigating lamination features in balloon measurements of ozone mixing ratio and potential temperature. Laminae are defined as stratified variations in ozone that meet or exceed a 10 % threshold for deviations from a basic state vertical profile of ozone. The basic state profiles are derived for each sounding using smoothing methods applied within a vertical coordinate system relative to the WMO tropopause. We present results of this analysis for the 25-year record of ozonesonde measurements from Boulder, Colorado. The mean number of ozone laminae identified per sounding is about 9±2 (1σ). The root-mean-square relative amplitude is 20 %, and laminae with much larger amplitudes (> 40 %) are seen in ~ 2 % of the profiles. The vertical scale of detected ozone laminae typically ranges between 0.5 and 1.2 km. The lamina occurrence frequency varies significantly with altitude and is largest within ~ 2 km of the tropopause. Overall, ozone laminae identified in our analysis account for more than one third of the total intraseasonal variability in ozone. A correlation technique between ozone and potential temperature is used to classify the subset of ozone laminae that are associated with gravity wave (GW) phenomena, which accounts for 28 % of all laminar ozone features. The remaining 72 % of laminae arise from non-gravity wave (NGW) phenomena. There are differences in the both the vertical distribution and seasonality of GW versus NGW ozone laminae that are linked to the contrast in main generating mechanisms for each laminae type.
- 4 October 2018
- Published by Copernicus GmbH in EGUsphere
- Vol. 2018, 1-25
Open AccessDetection and Classification of Laminae in Balloon-borne Ozonesonde Profiles: Application to the Long Term Record from Boulder, Colorado
We quantify ozone variability in the upper troposphere and lower stratosphere (UTLS) by investigating lamination features in balloon measurements of ozone mixing ratio and potential temperature. Laminae are defined as stratified variations in ozone that meet or exceed a 10 % threshold for deviations from a basic state vertical profile of ozone. The basic state profiles are derived for each sounding using smoothing methods applied within a vertical coordinate system relative to the WMO tropopause. We present results of this analysis for the 25-year record of ozonesonde measurements from Boulder, Colorado. The mean number of ozone laminae identified per sounding is about 9±2 (1σ). The root-mean-square relative amplitude is 20 %, and laminae with much larger amplitudes (> 40 %) are seen in ~ 2 % of the profiles. The vertical scale of detected ozone laminae typically ranges between 0.5 and 1.2 km. The lamina occurrence frequency varies significantly with altitude and is largest within ~ 2 km of the tropopause. Overall, ozone laminae identified in our analysis account for more than one third of the total intraseasonal variability in ozone. A correlation technique between ozone and potential temperature is used to classify the subset of ozone laminae that are associated with gravity wave (GW) phenomena, which accounts for 28 % of all laminar ozone features. The remaining 72 % of laminae arise from non-gravity wave (NGW) phenomena. There are differences in the both the vertical distribution and seasonality of GW versus NGW ozone laminae that are linked to the contrast in main generating mechanisms for each laminae type.
- Open Access
- 6 July 2018
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 11 (7) , 3969-3985
HOVERCAT: a novel aerial system for evaluation of aerosol–cloud interactions
Aerosols have a profound impact on cloud microphysics through their ability to serve as ice nucleating particles (INPs). As a result, cloud radiative properties and precipitation processes can be modulated by such aerosol–cloud interactions. However, one of the largest uncertainties associated with atmospheric processes is the indirect effect of aerosols on clouds. The need for more advanced observations of INPs in the atmospheric vertical profile is apparent, yet most ice nucleation measurements are conducted on the ground or during infrequent and intensive airborne field campaigns. Here, we describe a novel measurement platform that is less expensive and smaller (< 5 kg) when compared to traditional aircraft and tethered balloon platforms and that can be used for evaluating two modes of ice nucleation (i.e., immersion and deposition). HOVERCAT (Honing On VERtical Cloud and Aerosol properTies) flew during a pilot study in Colorado, USA, up to 2.6 km above mean sea level (1.1 km above ground level) and consists of an aerosol module that includes an optical particle counter for size distributions (0.38–17 µm in diameter) and a new sampler that collects up to 10 filter samples for offline ice nucleation and aerosol analyses on a launched balloon platform. During the May 2017 test flight, total particle concentrations were highest closest to the ground (up to 50 cm−3 at < 50 m above ground level) and up to 2 in 102 particles were ice nucleation active in the immersion mode (at −23 °C). The warmest temperature immersion and deposition mode INPs (observed up to −6 and −40.4 °C, respectively) were observed closest to the ground, but overall INP concentrations did not exhibit an inverse correlation with increasing altitude. HOVERCAT is a prototype that can be further modified for other airborne platforms, including tethered balloon and unmanned aircraft systems. The versatility of HOVERCAT affords future opportunities to profile the atmospheric column for more comprehensive evaluations of aerosol–cloud interactions. Based on our test flight experiences, we provide a set of recommendations for future deployments of similar measurement systems and platforms.
- 6 July 2018
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 11 (7) , 3969-3985
Open AccessHOVERCAT: a novel aerial system for evaluation of aerosol–cloud interactions
Aerosols have a profound impact on cloud microphysics through their ability to serve as ice nucleating particles (INPs). As a result, cloud radiative properties and precipitation processes can be modulated by such aerosol–cloud interactions. However, one of the largest uncertainties associated with atmospheric processes is the indirect effect of aerosols on clouds. The need for more advanced observations of INPs in the atmospheric vertical profile is apparent, yet most ice nucleation measurements are conducted on the ground or during infrequent and intensive airborne field campaigns. Here, we describe a novel measurement platform that is less expensive and smaller (< 5 kg) when compared to traditional aircraft and tethered balloon platforms and that can be used for evaluating two modes of ice nucleation (i.e., immersion and deposition). HOVERCAT (Honing On VERtical Cloud and Aerosol properTies) flew during a pilot study in Colorado, USA, up to 2.6 km above mean sea level (1.1 km above ground level) and consists of an aerosol module that includes an optical particle counter for size distributions (0.38–17 µm in diameter) and a new sampler that collects up to 10 filter samples for offline ice nucleation and aerosol analyses on a launched balloon platform. During the May 2017 test flight, total particle concentrations were highest closest to the ground (up to 50 cm−3 at < 50 m above ground level) and up to 2 in 102 particles were ice nucleation active in the immersion mode (at −23 °C). The warmest temperature immersion and deposition mode INPs (observed up to −6 and −40.4 °C, respectively) were observed closest to the ground, but overall INP concentrations did not exhibit an inverse correlation with increasing altitude. HOVERCAT is a prototype that can be further modified for other airborne platforms, including tethered balloon and unmanned aircraft systems. The versatility of HOVERCAT affords future opportunities to profile the atmospheric column for more comprehensive evaluations of aerosol–cloud interactions. Based on our test flight experiences, we provide a set of recommendations for future deployments of similar measurement systems and platforms.