ABAnneloes E. Bohte

Anneloes E. Bohte

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Anneloes E. Bohte has a total of 64 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Imaging in rhabdomyosarcoma: a patient journey

    by Isabelle S A de Vries, Roelof van Ewijk, Laura M E Adriaansen, Anneloes E Bohte, Arthur J A T Braat, Raquel Dávila Fajardo, Laura S Hiemcke-Jiwa, Marinka L F Hol, Simone A J Ter Horst, Bart de Keizer, et al.

    Rhabdomyosarcoma, although rare, is the most frequent soft tissue sarcoma in children and adolescents. It can present as a mass at nearly any site in the body, with most common presentations in the head and neck, genitourinary tract and extremities. The optimal diagnostic approach and management of rhabdomyosarcoma require a multidisciplinary team with multimodal treatment, including chemotherapy and local therapy. Survival has improved over the last decades; however, further improvement in management is essential with current 5-year overall survival ranging from 35% to 100%, depending on disease and patient characteristics. In the full patient journey, from diagnosis, staging, management to follow-up after therapy, the paediatric radiologist and nuclear physician are essential members of the multidisciplinary team. Recently, guidelines of the European paediatric Soft tissue sarcoma Study Group, the Cooperative Weichteilsarkom Studiengruppe and the Oncology Task Force of the European Society of Paediatric Radiology (ESPR), in an ongoing collaboration with the International Soft-Tissue Sarcoma Database Consortium, provided guidance for high-quality imaging. In this educational paper, given as a lecture during the 2022 postgraduate ESPR course, the multi-disciplinary team of our national paediatric oncology centre presents the journey of two patients with rhabdomyosarcoma and discusses the impact on and considerations for the clinical (paediatric) radiologist and nuclear physician. The key learning points of the guidelines and their implementation in clinical practice are highlighted and up-to-date insights provided for all aspects from clinical suspicion of rhabdomyosarcoma and its differential diagnosis, to biopsy, staging, risk stratification, treatment response assessment and follow-up.


  • Open Access

    Imaging features of hepatic sinusoidal obstruction syndrome or veno-occlusive disease in children

    by Anneloes E. Bohte, Miranda P. Dierselhuis, Max M. van Noesel, Maarten H. Lequin

    Hepatic sinusoidal obstruction syndrome, also known as veno-occlusive disease, can occur as a complication of myeloablative chemotherapy, as a result of low-intensity chemotherapy-related liver toxicity or radiotherapy of the liver. Symptoms of sinusoidal obstruction syndrome can range from asymptomatic to liver dysfunction or severe disease with life-threatening acute multi-organ failure. Imaging features can suggest or support this clinical diagnosis. Familiarity with the imaging spectrum of sinusoidal obstruction syndrome is therefore important for both radiologists and clinical oncologists. Here, multi-modality radiologic appearances of sinusoidal obstruction syndrome in pediatric patients are illustrated, including outcome after follow-up.


  • Correction to: Neonatal bacterial meningitis versus ventriculitis: a cohort-based overview of clinical characteristics, microbiology and imaging

    by Thomas Peros, Joost van Schuppen, Anneloes Bohte, Caspar Hodiamont, Eleonora Aronica, Timo R. de Haan

  • Open Access

    Neonatal bacterial meningitis versus ventriculitis: a cohort-based overview of clinical characteristics, microbiology and imaging

    by Thomas Peros, Joost van Schuppen, Anneloes Bohte, Caspar Hodiamont, Eleonora Aronica, Timo de Haan

    Central nervous system (CNS) infections are potentially life threatening in neonates and can lead to the ill-defined diagnosis of ventriculitis. With this study we aimed to explore and describe ventriculitis regarding clinical, microbiological and ultrasonographic characteristics. We performed a retrospective cohort study including all neonates with a culture-proven CNS infection admitted to our tertiary NICU over a 12-year period (2004–2016). For each case clinical data was gathered, and three timed cranial ultrasounds were anonymized and retrospectively reviewed and assessed for signs of ventriculitis. Forty-five patients were included with 9 (20%) diagnosed with ventriculitis. Mortality in both ventriculitis and non-ventriculitis cases was one-third. Patients with pre-existing conditions as post-haemorrhagic hydrocephalus are at risk of developing ventriculitis. Most common pathogens were gram negative bacteria (68.9%). Ultrasonographic signs of ventriculitis developed over time, and interrater agreement was substantial.Conclusion: Neonatal ventriculitis is a serious entity in the continuum of meningitis. Early and correct diagnoses of ventriculitis are both important because of possible persisting or newly developing hydrocephalus or seizures. Sequential imaging should be performed. What is Known:• CNS infections in neonates lead to high mortality and morbidity.• Ventriculitis is a severe complication of meningitis. What is New:• High morbidity; the majority of ventriculitis patients have pre-existing PHVD and develop seizures and hydrocephalus.• Interrater agreement is good; bedside CUS is a useful tool for reaching a sustainable diagnosis of ventriculitis.


  • Breast magnetic resonance elastography: a review of clinical work and future perspectives

    by A.E. Bohte, J.L. Nelissen, J.H. Runge, O. Holub, S.A. Lambert, L. de Graaf, S. Kolkman, S. van der Meij, J. Stoker, G.J. Strijkers, et al.

    This review on magnetic resonance elastography (MRE) of the breast provides an overview of available literature and describes current developments in the field of breast MRE, including new transducer technology for data acquisition and multi‐frequency‐derived power‐law behaviour of tissue. Moreover, we discuss the future potential of breast MRE, which goes beyond its original application as an additional tool in differentiating benign from malignant breast lesions. These areas of ongoing and future research include MRE for pre‐operative tumour delineation, staging, monitoring and predicting response to treatment, as well as prediction of the metastatic potential of primary tumours.


  • Non-invasive evaluation of liver fibrosis: a comparison of ultrasound-based transient elastography and MR elastography in patients with viral hepatitis B and C

    by Anneloes E. Bohte, Annikki de Niet, Louis Jansen, Shandra Bipat, Aart J. Nederveen, Joanne Verheij, Valeska Terpstra, Ralph Sinkus, Karin M. J. van Nieuwkerk, Rob J. de Knegt, et al.

    To compare the diagnostic accuracy of TE and MRE and establish cutoff levels and diagnostic strategies for both techniques, enabling selection of patients for liver biopsy. One hundred three patients with chronic hepatitis B or C and liver biopsy were prospectively included. Areas under curves (AUROC) were compared for TE and MRE for METAVIR fibrosis grade ≥ F2 and ≥F3. We defined cutoff values for selection of patients with F0–F1 (sensitivity >95 %) and for significant fibrosis F2–F4 (specificity >95 %). Following exclusions, 85 patients were analysed (65 CHB, 19 CHC, 1 co-infected). Fibrosis stages were F0 (n = 3), F1 (n = 53), F2 (n = 15), F3 (n = 8) and F4 (n = 6). TE and MRE accuracy were comparable [AUROCTE ≥ F2: 0.914 (95 % CI: 0.857–0.972) vs. AUROCMRE ≥ F2: 0.909 (0.840–0.977), P = 0.89; AUROCTE ≥ F3: 0.895 (0.816–0.974) vs. AUROCMRE ≥ F3: 0.928 (0.874–0.982), P = 0.42]. Cutoff values of TE and MRE have comparable accuracy for detecting significant fibrosis, which was reliably detected or excluded in two-thirds of patients. A conditional strategy further increased diagnostic yield to 80 %. • Both ultrasound-based transient elastography and magnetic resonance elastography can assess hepatic fibrosis. • Both have comparable accuracy for detecting liver fibrosis in viral hepatitis. • The individual techniques reliably detect or exclude significant liver fibrosis in 66 %. • A conditional strategy for inconclusive findings increases the number of correct diagnoses.


  • Ultrasonography is not more reliable than anthropometry for assessing visceral fat in obese children

    by B. G. P. Koot, R. Westerhout, A. E. Bohte, S. Vinke, T. H. Pels Rijcken, A. J. Nederveen, M. W. A. Caan, O. H. van der Baan‐Slootweg, M. P. Merkus, J. Stoker, et al.

    Visceral fat accumulation is a risk factor for obesity-related complications. Waist circumference is used in clinical practice to assess visceral adiposity. Ultrasound is not superior to waist circumference for assessing visceral obesity in obese children. The optimal site for measuring waist circumference in obese children is at the smallest body circumference between xiphisternum and umbilicus. Visceral fat accumulation is a well-established risk factor for obesity-related complications. In children, it has not been determined whether ultrasonography is superior to waist measurement for assessing visceral fat. Moreover, the optimal site for waist measurement has not been determined. In a prospective cohort of 92 severely obese children and adolescents (age 13.9 ± 2.2 years, body mass index z-score 3.29 ± 0.33), we evaluated the performance of ultrasonography and two different methods of waist circumference measurement, using magnetic resonance imaging as the reference standard. Waist circumference, defined as the smallest body circumference between xiphisternum and umbilicus had the strongest correlation with visceral fat quantity (r = 0.69 all, r = 0.68 girls, r = 0.64 boys). It was not outperformed by ultrasonography (r = 0.60 all, r = 0.62 girls, r = 0.50 boys) and correlated significantly better than the World Health Organization standard for waist measurement, midway between lower margin of the last rib and the crest of the ilium, (r = 0.51 all, r = 0.39 girls, r = 0.46 boys). Waist circumference measurement, defined as the smallest body circumference between xiphisternum and umbilicus, is the preferred non-invasive technique for daily clinical practice to assess visceral fat accumulation in severely obese children and adolescents. There is no place for ultrasonography for the quantification of visceral fat in this grou


  • US Cannot Be Used to Predict the Presence or Severity of Hepatic Steatosis in Severely Obese Adolescents

    by Anneloes E. Bohte, Bart G. P. Koot, Olga H. van der Baan-Slootweg, Tammo H. Pels Rijcken, Jochem R. van Werven, Shandra Bipat, Aart J. Nederveen, Peter L. M. Jansen, Marc A. Benninga, Jaap Stoker

    To evaluate the diagnostic accuracy of ultrasonography (US) for the assessment of hepatic steatosis in severely obese adolescents, with proton magnetic resonance (MR) spectroscopy as the reference standard, and to provide insight on the influence of prevalence on predictive values by calculating positive and negative posttest probabilities. This prospective study was institutional review board approved. All participants, and/or their legal representatives, gave written informed consent. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for the overall presence of steatosis and for the presence of substantial (moderate to severe) steatosis. Positive and negative posttest probabilities were calculated and plotted against prevalence. A total of 104 children (47 male, 57 female) were prospectively included. Mean age was 14.5 years (range, 8.3-18.9 years) and mean age-adjusted standard deviation body mass index (BMI) score (BMI z score) was 3.3 (range, 2.6-4.1). The overall prevalence of hepatic steatosis was 46.2% (48 of 104). Sensitivity of US was 85.4% (41 of 48), specificity was 55.4% (31 of 56), PPV was 62.1% (41 of 66), and NPV was 81.6% (31 of 38). The prevalence of substantial steatosis was 15.4% (16 of 104), with US sensitivity of 75.0% (12 of 16) and specificity of 87.5% (77 of 88). PPV was 52.2% (12 of 23) and NPV was 95.1% (77 of 81). Plotting of posttest probabilities against prevalence for both disease degrees demonstrated how disease prevalence influences US accuracy. Positive US results in severely obese adolescents cannot be used to accurately predict the presence and severity of hepatic steatosis, and additional imaging is required. Negative US results exclude the presence of substantial steatosis with acceptable accuracy. Steatosis prevalence differs among specific populations, strongly influencing posttest probabilities.


  • Top Cited Papers
    Open Access

    The diagnostic accuracy of US, CT, MRI and 1H-MRS for the evaluation of hepatic steatosis compared with liver biopsy: a meta-analysis

    by Anneloes E. Bohte, Jochem R. van Werven, Shandra Bipat, Jaap Stoker

    Objective To meta-analyse the diagnostic accuracy of US, CT, MRI and 1H-MRS for the evaluation of hepatic steatosis. Methods From a comprehensive literature search in MEDLINE, EMBASE, CINAHL and Cochrane (up to November 2009), articles were selected that investigated the diagnostic performance imaging techniques for evaluating hepatic steatosis with histopathology as the reference standard. Cut-off values for the presence of steatosis on liver biopsy were subdivided into four groups: (1) >0, >2 and >5% steatosis; (2) >10, >15 and >20%; (3) >25, >30 and >33%; (4) >50, >60 and >66%. Per group, summary estimates for sensitivity and specificity were calculated. The natural-logarithm of the diagnostic odds ratio (lnDOR) was used as a single indicator of test performance. Results 46 articles were included. Mean sensitivity estimates for subgroups were 73.3–90.5% (US), 46.1–72.0% (CT), 82.0–97.4% (MRI) and 72.7–88.5% (1H-MRS). Mean specificity ranges were 69.6–85.2% (US), 88.1–94.6% (CT), 76.1–95.3% (MRI) and 92.0–95.7% (1H-MRS). Overall performance (lnDOR) of MRI and 1H-MRS was better than that for US and CT for all subgroups, with significant differences in groups 1 and 2. Conclusion MRI and 1H-MRS can be considered techniques of choice for accurate evaluation of hepatic steatosis.