Lingjie Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lingjie Wu has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Zebin Xiao
Cultivation and Construction Site of the State Key Laboratory of Intelligent Imaging and Interventional Medicine, Department of Radiology, Zhongda Hospital, Medical School of Southeast University, Nanjing, China
3 shared publications - Zuohua Tang
Department of Radiology, Eye & ENT Hospital, Fudan University, Shanghai, China
3 shared publications - Haitao Wu
ENT institute and Department of Otorhinolaryngology, Eye & ENT Hospital, Fudan University, Shanghai, China
2 shared publications Jie Wang
Department of Radiotherapy, Eye & ENT Hospital of Shanghai Medical School, Fudan University, Shanghai, 200031, China
2 shared publications- Lei Zhang
Academy for Engineering and Technology, Fudan University, Shanghai 200433, China
2 shared publications Lixin Jin
Siemens Ltd. Healthcare sector, Shanghai, 201318, China
2 shared publications
Latest Publications
- 4 August 2025
- Published by Wiley in The Laryngoscope
- Vol. 136 (1) , 351-359
Pathological Grading Determines the Clinical Efficacy of Outpatient KTP Laser Treatment for Vocal Fold Leukoplakia
Objective: Vocal fold leukoplakia is commonly managed with outpatient potassium titanyl phosphate (KTP) laser therapy; however, limited data exist on the impact of different pathological grades on long‐term efficacy. This study retrospectively analyzed the treatment outcomes, identified prognostic factors, and provided insights to improve disease characterization and clinical management. Study Design: Retrospective study (2017–2024). Methods: Ninety two patients with vocal fold leukoplakia treated in Fudan Eye and ENT hospital (FD‐EENT) were included. The mean follow‐up period after the last treatment was 20.53 ± 17.32 months. Disease control was assessed by lesion regression using ImageJ analysis. Acoustic outcomes were evaluated using the Voice Handicap Index‐30 (VHI‐30), GRBAS scale, and other acoustic parameters. Results: Patients underwent a mean of 1.6 treatment sessions. Following the last treatment, the lesion regression rates were 90.1% for no dysplasia, 81.75% for mild dysplasia, and 86.83% for moderate dysplasia, compared to 51.0% for severe dysplasia and 32.9% for carcinoma in situ (CIS). Patients with pathological grades of severe dysplasia and CIS showed significantly poorer treatment outcomes than those with milder dysplasia (*** p = 0.0001). Conclusion: Outpatient KTP laser effectively controls disease progression in vocal fold leukoplakia, with efficacy linked to the degree of dysplasia. KTP laser is an effective treatment for milder pathological dysplasia, but its efficacy diminishes in more severe stages. The treatment should be carefully considered for patients with severe dysplasia and CIS, with close follow‐up, and biopsy should be performed to monitor malignant transformation and prevent delayed treatment. Level of Evidence: 4.
- 4 August 2025
- Published by Wiley in The Laryngoscope
- Vol. 136 (1) , 351-359
Pathological Grading Determines the Clinical Efficacy of Outpatient KTP Laser Treatment for Vocal Fold Leukoplakia
Objective: Vocal fold leukoplakia is commonly managed with outpatient potassium titanyl phosphate (KTP) laser therapy; however, limited data exist on the impact of different pathological grades on long‐term efficacy. This study retrospectively analyzed the treatment outcomes, identified prognostic factors, and provided insights to improve disease characterization and clinical management. Study Design: Retrospective study (2017–2024). Methods: Ninety two patients with vocal fold leukoplakia treated in Fudan Eye and ENT hospital (FD‐EENT) were included. The mean follow‐up period after the last treatment was 20.53 ± 17.32 months. Disease control was assessed by lesion regression using ImageJ analysis. Acoustic outcomes were evaluated using the Voice Handicap Index‐30 (VHI‐30), GRBAS scale, and other acoustic parameters. Results: Patients underwent a mean of 1.6 treatment sessions. Following the last treatment, the lesion regression rates were 90.1% for no dysplasia, 81.75% for mild dysplasia, and 86.83% for moderate dysplasia, compared to 51.0% for severe dysplasia and 32.9% for carcinoma in situ (CIS). Patients with pathological grades of severe dysplasia and CIS showed significantly poorer treatment outcomes than those with milder dysplasia (*** p = 0.0001). Conclusion: Outpatient KTP laser effectively controls disease progression in vocal fold leukoplakia, with efficacy linked to the degree of dysplasia. KTP laser is an effective treatment for milder pathological dysplasia, but its efficacy diminishes in more severe stages. The treatment should be carefully considered for patients with severe dysplasia and CIS, with close follow‐up, and biopsy should be performed to monitor malignant transformation and prevent delayed treatment. Level of Evidence: 4.
- Open Access
- 17 March 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (6) , 1151
A Novel Framework of Manifold Learning Cascade-Clustering for the Informative Frame Selection
Narrow band imaging is an established non-invasive tool used for the early detection of laryngeal cancer in surveillance examinations. Most images produced from the examination are useless, such as blurred, specular reflection, and underexposed. Removing the uninformative frames is vital to improve detection accuracy and speed up computer-aided diagnosis. It often takes a lot of time for the physician to manually inspect the informative frames. This issue is commonly addressed by a classifier with task-specific categories of the uninformative frames. However, the definition of the uninformative categories is ambiguous, and tedious labeling still cannot be avoided. Here, we show that a novel unsupervised scheme is comparable to the current benchmarks on the dataset of NBI-InfFrames. We extract feature embedding using a vanilla neural network (VGG16) and introduce a new dimensionality reduction method called UMAP that distinguishes the feature embedding in the lower-dimensional space. Along with the proposed automatic cluster labeling algorithm and cost function in Bayesian optimization, the proposed method coupled with UMAP achieves state-of-the-art performance. It outperforms the baseline by 12% absolute. The overall median recall of the proposed method is currently the highest, 96%. Our results demonstrate the effectiveness of the proposed scheme and the robustness of detecting the informative frames. It also suggests the patterns embedded in the data help develop flexible algorithms that do not require manual labeling.
- 17 March 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (6) , 1151
Open AccessA Novel Framework of Manifold Learning Cascade-Clustering for the Informative Frame Selection
Narrow band imaging is an established non-invasive tool used for the early detection of laryngeal cancer in surveillance examinations. Most images produced from the examination are useless, such as blurred, specular reflection, and underexposed. Removing the uninformative frames is vital to improve detection accuracy and speed up computer-aided diagnosis. It often takes a lot of time for the physician to manually inspect the informative frames. This issue is commonly addressed by a classifier with task-specific categories of the uninformative frames. However, the definition of the uninformative categories is ambiguous, and tedious labeling still cannot be avoided. Here, we show that a novel unsupervised scheme is comparable to the current benchmarks on the dataset of NBI-InfFrames. We extract feature embedding using a vanilla neural network (VGG16) and introduce a new dimensionality reduction method called UMAP that distinguishes the feature embedding in the lower-dimensional space. Along with the proposed automatic cluster labeling algorithm and cost function in Bayesian optimization, the proposed method coupled with UMAP achieves state-of-the-art performance. It outperforms the baseline by 12% absolute. The overall median recall of the proposed method is currently the highest, 96%. Our results demonstrate the effectiveness of the proposed scheme and the robustness of detecting the informative frames. It also suggests the patterns embedded in the data help develop flexible algorithms that do not require manual labeling.
- 3 March 2023
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 44 (5) , 1036-1042
An Accurate and Individualized Preoperative Estimation Method for the Linear Insertion Depth of Cochlear Implant Electrode Arrays Based on Computed Tomography
Objectives: Cochlear implantation or auditory brainstem implantation is currently the only accepted method for improving severe or profound sensorineural hearing loss. The length of the electrodes implanted during cochlear implantation is closely related to the degree of hearing improvement of hearing after the surgery. We aimed to explore new methods to accurately estimate the electrode array (EA) linear insertion depth based on computed tomography (CT) images prior surgery, which could help surgeons select the appropriate EA length for each patient. Design: Previous studies estimated the linear insertion depth by measuring the length of the lateral wall of the cochlea rather than the electrode’s path in the cochlea duct. Here, we determined the actual position of the EA on the CT image after cochlear surgery in order to predict the path of the EA, and the length of the predicted EA path was measured by the contouring technique (CoT) to estimate the linear insertion depth of the EA. Because CoT can only measure the length of the estimated EA path on a two-dimensional plane, we further modified the measurement by weighting the height of the cochlea and the length of the EA tail (the length of the last stimulating electrode to the end, which cannot be displayed on the CT image), which we termed the modified CoT + height + tail (MCHT) measurement. Results: Based on our established method, MCHT could reduce the error to the submillimeter range (0.67 ± 0.37 mm) when estimating the linear insertion depth of various kinds of EAs compared with the actual implant length. The correlation coefficient between the linear insertion depth as predicted by MCHT and the actual was 0.958. The linear insertion depth estimated by this method was more accurate than that estimated using the classical CoT technique (R = 0.442) and using the modified Escudé’s method (R = 0.585). Conclusions: MCHT is a method based on CT images that can accurately predict the linear insertion depth of cochlear implants preoperatively. This is the first report that we are aware of a method for predicting linear insertion depth before cochlear implantation with only submillimeter errors and that is tailored to different types of EAs.
- 3 March 2023
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 44 (5) , 1036-1042
An Accurate and Individualized Preoperative Estimation Method for the Linear Insertion Depth of Cochlear Implant Electrode Arrays Based on Computed Tomography
Objectives: Cochlear implantation or auditory brainstem implantation is currently the only accepted method for improving severe or profound sensorineural hearing loss. The length of the electrodes implanted during cochlear implantation is closely related to the degree of hearing improvement of hearing after the surgery. We aimed to explore new methods to accurately estimate the electrode array (EA) linear insertion depth based on computed tomography (CT) images prior surgery, which could help surgeons select the appropriate EA length for each patient. Design: Previous studies estimated the linear insertion depth by measuring the length of the lateral wall of the cochlea rather than the electrode’s path in the cochlea duct. Here, we determined the actual position of the EA on the CT image after cochlear surgery in order to predict the path of the EA, and the length of the predicted EA path was measured by the contouring technique (CoT) to estimate the linear insertion depth of the EA. Because CoT can only measure the length of the estimated EA path on a two-dimensional plane, we further modified the measurement by weighting the height of the cochlea and the length of the EA tail (the length of the last stimulating electrode to the end, which cannot be displayed on the CT image), which we termed the modified CoT + height + tail (MCHT) measurement. Results: Based on our established method, MCHT could reduce the error to the submillimeter range (0.67 ± 0.37 mm) when estimating the linear insertion depth of various kinds of EAs compared with the actual implant length. The correlation coefficient between the linear insertion depth as predicted by MCHT and the actual was 0.958. The linear insertion depth estimated by this method was more accurate than that estimated using the classical CoT technique (R = 0.442) and using the modified Escudé’s method (R = 0.585). Conclusions: MCHT is a method based on CT images that can accurately predict the linear insertion depth of cochlear implants preoperatively. This is the first report that we are aware of a method for predicting linear insertion depth before cochlear implantation with only submillimeter errors and that is tailored to different types of EAs.
- 21 June 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 147, 105763
Adaptive Cross Entropy for ultrasmall object detection in Computed Tomography with noisy labels
- 21 June 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 147, 105763
Adaptive Cross Entropy for ultrasmall object detection in Computed Tomography with noisy labels
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 123-128
Deep Convolutional Neural Networks for Accurate Diagnosis of Nasopharyngeal Carcinoma in pCLE Images
Objectives/Hypothesis: Probe-based confocal laser endomicroscopy(pCLE) can be used for the real-time cell-level optical biopsy of nasopharyngeal lesions in vivo. The development and validation of deep-learning-based automatic diagnosis of pCLE images are essential to the rapid screening and detection of nasopharyngeal carcinoma. Methods: From May 1, 2017, to November 30, 2017, the pCLE images were consecutively collected as samples in data sets from 31 patients with highly suspected NPC. The pCLE images were divided into training, cross-validation, and test sets to train, validate and test the proposed model. The proposed model's accuracy, sensitivity, and specificity are using pathological diagnosis as the gold standard. Analysis of the data is from May 15, 2019, to May 31, 2020. Results: The data set contains 3623 pCLE images in total. Eighty percent of the images were selected randomly as the training set, then another 10% as the validation set, and the last 10% as the test set. We proposed a deep learning model based on ResNet50. On the test data set, the model achieved an overall detection accuracy of 94.7%. The proposed model has higher accuracy, over 20.8%, compared to the best traditional supervised machine learning. Conclusions: Our algorithm automatically detected the nasopharyngeal carcinoma through screening images, which conduces to the otolaryngologists in their diagnosis. This deep-learning-based framework will be of great importance in the rapid screening and detecting of NPC.
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 123-128
Deep Convolutional Neural Networks for Accurate Diagnosis of Nasopharyngeal Carcinoma in pCLE Images
Objectives/Hypothesis: Probe-based confocal laser endomicroscopy(pCLE) can be used for the real-time cell-level optical biopsy of nasopharyngeal lesions in vivo. The development and validation of deep-learning-based automatic diagnosis of pCLE images are essential to the rapid screening and detection of nasopharyngeal carcinoma. Methods: From May 1, 2017, to November 30, 2017, the pCLE images were consecutively collected as samples in data sets from 31 patients with highly suspected NPC. The pCLE images were divided into training, cross-validation, and test sets to train, validate and test the proposed model. The proposed model's accuracy, sensitivity, and specificity are using pathological diagnosis as the gold standard. Analysis of the data is from May 15, 2019, to May 31, 2020. Results: The data set contains 3623 pCLE images in total. Eighty percent of the images were selected randomly as the training set, then another 10% as the validation set, and the last 10% as the test set. We proposed a deep learning model based on ResNet50. On the test data set, the model achieved an overall detection accuracy of 94.7%. The proposed model has higher accuracy, over 20.8%, compared to the best traditional supervised machine learning. Conclusions: Our algorithm automatically detected the nasopharyngeal carcinoma through screening images, which conduces to the otolaryngologists in their diagnosis. This deep-learning-based framework will be of great importance in the rapid screening and detecting of NPC.
- 27 August 2018
- Published by Wiley in The Laryngoscope
- Vol. 129 (4) , 897-902
Probe‐based confocal laser endomicroscopy for diagnosis of nasopharyngeal carcinoma in vivo
Objectives/Hypothesis: Probe‐based confocal laser endomicroscopy (pCLE) is a novel technique allowing real‐time evaluation of the histological features of tissues in vivo at the cellular level. This study aimed to evaluate the feasibility of using pCLE in the diagnosis of nasopharyngeal carcinoma (NPC).Study Design: Feasibility study.Methods: In this study, the pCLE images of the lesions, as well as the surrounding or contralateral normal mucosa of the lesions, were acquired in vivo from each patient after intravenous injecting of 2.5 mL fluorescein. Biopsy specimens were collected at the imaged sites followed by a histopathological diagnosis by the pathologists, which was used as the gold standard. The pCLE images were compared to histopathological diagnosis of visualized sites by using sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV).Results: Diagnoses based on pCLE images correlated well with the gold standard diagnoses based on tissue histology. The overall sensitivity, specificity, PPV, and NPV for diagnosis of carcinoma versus nondysplasia were 93.8% (67.7%‐99.7%), 90.5% (68.2%‐98.3%), 88.2% (62.3%‐97.9%), and 95.0% (73.1%‐99.7%), respectively, and the four indices for pCLE diagnosis of dysplasia versus nondysplasia were 60.0% (17.0%‐92.7%), 80.9% (57.4%‐93.7%), 42.9% (11.8%‐79.8%), and 89.5% (65.5%‐98.2%), respectively. The overall sensitivity for diagnosis of carcinoma versus dysplasia was 93.8% (67.7%‐99.7%), specificity was 40% (7.3%‐83.0%), PPV was 83.3% (57.7%‐95.6%), and the NPV was 66.7% (12.5%‐98.2%).Conclusions: CLE is a suitable and valid method for otolaryngologists to diagnose of NPC in vivo.Level of Evidence: NA Laryngoscope, 129:897–902, 2019
- 27 August 2018
- Published by Wiley in The Laryngoscope
- Vol. 129 (4) , 897-902
Probe‐based confocal laser endomicroscopy for diagnosis of nasopharyngeal carcinoma in vivo
Objectives/Hypothesis: Probe‐based confocal laser endomicroscopy (pCLE) is a novel technique allowing real‐time evaluation of the histological features of tissues in vivo at the cellular level. This study aimed to evaluate the feasibility of using pCLE in the diagnosis of nasopharyngeal carcinoma (NPC).Study Design: Feasibility study.Methods: In this study, the pCLE images of the lesions, as well as the surrounding or contralateral normal mucosa of the lesions, were acquired in vivo from each patient after intravenous injecting of 2.5 mL fluorescein. Biopsy specimens were collected at the imaged sites followed by a histopathological diagnosis by the pathologists, which was used as the gold standard. The pCLE images were compared to histopathological diagnosis of visualized sites by using sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV).Results: Diagnoses based on pCLE images correlated well with the gold standard diagnoses based on tissue histology. The overall sensitivity, specificity, PPV, and NPV for diagnosis of carcinoma versus nondysplasia were 93.8% (67.7%‐99.7%), 90.5% (68.2%‐98.3%), 88.2% (62.3%‐97.9%), and 95.0% (73.1%‐99.7%), respectively, and the four indices for pCLE diagnosis of dysplasia versus nondysplasia were 60.0% (17.0%‐92.7%), 80.9% (57.4%‐93.7%), 42.9% (11.8%‐79.8%), and 89.5% (65.5%‐98.2%), respectively. The overall sensitivity for diagnosis of carcinoma versus dysplasia was 93.8% (67.7%‐99.7%), specificity was 40% (7.3%‐83.0%), PPV was 83.3% (57.7%‐95.6%), and the NPV was 66.7% (12.5%‐98.2%).Conclusions: CLE is a suitable and valid method for otolaryngologists to diagnose of NPC in vivo.Level of Evidence: NA Laryngoscope, 129:897–902, 2019
- Open Access
- 25 January 2018
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 39 (3) , 538-546
Intravoxel Incoherent Motion MR Imaging in the Differentiation of Benign and Malignant Sinonasal Lesions: Comparison with Conventional Diffusion-Weighted MR Imaging
BACKGROUND AND PURPOSE: Intravoxel incoherent motion is a promising method for the differentiation of sinonasal lesions. This study aimed to evaluate the value of intravoxel incoherent motion in the differentiation of benign and malignant sinonasal lesions and to compare the diagnostic performance of intravoxel incoherent motion with that of conventional DWI. MATERIALS AND METHODS: One hundred thirty-one patients with histologically proved solid sinonasal lesions (56 benign and 75 malignant) who underwent conventional DWI and intravoxel incoherent motion were recruited in this study. The diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (f) values derived from intravoxel incoherent motion and ADC values derived from conventional DWI were measured and compared between the 2 groups using the Student t test. Receiver operating characteristic curve analysis, logistic regression analysis, and 10-fold cross-validation were performed to evaluate the diagnostic performance of single-parametric and multiparametric models. RESULTS: The mean ADC and D values were significantly lower in malignant sinonasal lesions than in benign sinonasal lesions (both P < .001). The mean f value was higher in malignant lesions than in benign lesions (P = .003). Multiparametric models can significantly improve the cross-validated areas under the curve for the differentiation of sinonasal lesions compared with single-parametric models (all corrected P < .05 except the D value). The model of D+f provided a better diagnostic performance than the ADC value (corrected P < .001). CONCLUSIONS: Intravoxel incoherent motion appears to be a more effective MR imaging technique than conventional DWI in the differentiation of benign and malignant sinonasal lesions.
- 25 January 2018
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 39 (3) , 538-546
Open AccessIntravoxel Incoherent Motion MR Imaging in the Differentiation of Benign and Malignant Sinonasal Lesions: Comparison with Conventional Diffusion-Weighted MR Imaging
BACKGROUND AND PURPOSE: Intravoxel incoherent motion is a promising method for the differentiation of sinonasal lesions. This study aimed to evaluate the value of intravoxel incoherent motion in the differentiation of benign and malignant sinonasal lesions and to compare the diagnostic performance of intravoxel incoherent motion with that of conventional DWI. MATERIALS AND METHODS: One hundred thirty-one patients with histologically proved solid sinonasal lesions (56 benign and 75 malignant) who underwent conventional DWI and intravoxel incoherent motion were recruited in this study. The diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (f) values derived from intravoxel incoherent motion and ADC values derived from conventional DWI were measured and compared between the 2 groups using the Student t test. Receiver operating characteristic curve analysis, logistic regression analysis, and 10-fold cross-validation were performed to evaluate the diagnostic performance of single-parametric and multiparametric models. RESULTS: The mean ADC and D values were significantly lower in malignant sinonasal lesions than in benign sinonasal lesions (both P < .001). The mean f value was higher in malignant lesions than in benign lesions (P = .003). Multiparametric models can significantly improve the cross-validated areas under the curve for the differentiation of sinonasal lesions compared with single-parametric models (all corrected P < .05 except the D value). The model of D+f provided a better diagnostic performance than the ADC value (corrected P < .001). CONCLUSIONS: Intravoxel incoherent motion appears to be a more effective MR imaging technique than conventional DWI in the differentiation of benign and malignant sinonasal lesions.
- 21 May 2017
- Published by Wiley in International Journal of Developmental Neuroscience
- Vol. 61 (1) , 12-20
Manganese‐enhanced MR imaging (MEMRI) combined with electrophysiology in the study of cross‐modal plasticity in binocularly blind rats
Our study aimed to determine and verify the establishment of visual to auditory cross-modal plasticity using manganese-enhanced MR imaging (MEMRI) combined with examinations of the visual evoked potential (VEP), auditory brainstem response (ABR) and bilateral visual cortex response to a bilateral auditory stimulus (AVR). Fourteen healthy male Sprague-Dawley newborn rats were randomly divided into 2 groups (n=7 per group). Optic nerve transection was performed in the 7 rats of Group A three weeks after birth to obtain binocularly blind models, and the 7 rats of Group B were maintained as the control group. The VEP was measured to ensure complete binocular blindness. Four months after the operation, MnCl was injected into the left inner ear perilymph of all rats, and an MRI examination was performed 24h after injection. Then, ABR and AVR were measured to detect the generation of auditory compensatory function. The results of the VEP have confirmed complete binocular blindness. The normalized signal intensity of the bilateral medial geniculate nucleus, auditory cortex, visual center (including the lateral geniculate nucleus, superior colliculus and visual cortex) and right hippocampus in binocularly blind rats was significantly increased compared with that in normal rats (P≤0.005), which was confirmed by measurement of the ABR and AVR. Our results suggested that MEMRI combined with electrophysiology can show changes in the auditory and visual pathways of binocularly blind rats and demonstrate the generation of an auditory compensatory pathway.
- 21 May 2017
- Published by Wiley in International Journal of Developmental Neuroscience
- Vol. 61 (1) , 12-20
Manganese‐enhanced MR imaging (MEMRI) combined with electrophysiology in the study of cross‐modal plasticity in binocularly blind rats
Our study aimed to determine and verify the establishment of visual to auditory cross-modal plasticity using manganese-enhanced MR imaging (MEMRI) combined with examinations of the visual evoked potential (VEP), auditory brainstem response (ABR) and bilateral visual cortex response to a bilateral auditory stimulus (AVR). Fourteen healthy male Sprague-Dawley newborn rats were randomly divided into 2 groups (n=7 per group). Optic nerve transection was performed in the 7 rats of Group A three weeks after birth to obtain binocularly blind models, and the 7 rats of Group B were maintained as the control group. The VEP was measured to ensure complete binocular blindness. Four months after the operation, MnCl was injected into the left inner ear perilymph of all rats, and an MRI examination was performed 24h after injection. Then, ABR and AVR were measured to detect the generation of auditory compensatory function. The results of the VEP have confirmed complete binocular blindness. The normalized signal intensity of the bilateral medial geniculate nucleus, auditory cortex, visual center (including the lateral geniculate nucleus, superior colliculus and visual cortex) and right hippocampus in binocularly blind rats was significantly increased compared with that in normal rats (P≤0.005), which was confirmed by measurement of the ABR and AVR. Our results suggested that MEMRI combined with electrophysiology can show changes in the auditory and visual pathways of binocularly blind rats and demonstrate the generation of an auditory compensatory pathway.
- 15 December 2016
- Published by Wiley in NMR in Biomedicine
- Vol. 30 (2)
Manganese‐enhanced MRI (ME MRI) in evaluation of the auditory pathway in an experimental rat model
This study aimed to explore the optimal dose and manner of administration for visualization of the auditory pathway on manganese‐enhanced MRI (ME MRI). Twenty‐four healthy male Sprague–Dawley rats were randomly divided into three experimental groups (n = 8 for Groups A, B and C). The rats in Groups A, B and C were subjected to MnCl2 injection through the tympanum, inner ear endolymph and perilymph, respectively (0.2 M for four rats and 0.4 M for the others in each group) and observed at 1, 2, 3, 4, 7 and 10 days after the operation with 3.0 T MRI. The signal intensity (SI) and dynamic changes of the auditory pathways at various times, and at two doses through three injection routes, were compared by statistical analysis. Administration of MnCl2 through the perilymph best showed the complete auditory pathway (P < 0.01), whereas administration though the tympanum only demonstrated part of the pathway. The SI was highest at 24 h after administration of the tracer and began to decline at 48 h. The SI of the auditory cortex was higher after the injection of 0.4 M MnCl2 than that of 0.2 M MnCl2. ME MRI best demonstrated the whole auditory pathway at 24 h after the injection of 0.4 M MnCl2 through the perilymph in the rat, which provided an optimal method for the study of ME MRI of the auditory pathway in the animal model.
- 15 December 2016
- Published by Wiley in NMR in Biomedicine
- Vol. 30 (2)
Manganese‐enhanced MRI (ME MRI) in evaluation of the auditory pathway in an experimental rat model
This study aimed to explore the optimal dose and manner of administration for visualization of the auditory pathway on manganese‐enhanced MRI (ME MRI). Twenty‐four healthy male Sprague–Dawley rats were randomly divided into three experimental groups (n = 8 for Groups A, B and C). The rats in Groups A, B and C were subjected to MnCl2 injection through the tympanum, inner ear endolymph and perilymph, respectively (0.2 M for four rats and 0.4 M for the others in each group) and observed at 1, 2, 3, 4, 7 and 10 days after the operation with 3.0 T MRI. The signal intensity (SI) and dynamic changes of the auditory pathways at various times, and at two doses through three injection routes, were compared by statistical analysis. Administration of MnCl2 through the perilymph best showed the complete auditory pathway (P < 0.01), whereas administration though the tympanum only demonstrated part of the pathway. The SI was highest at 24 h after administration of the tracer and began to decline at 48 h. The SI of the auditory cortex was higher after the injection of 0.4 M MnCl2 than that of 0.2 M MnCl2. ME MRI best demonstrated the whole auditory pathway at 24 h after the injection of 0.4 M MnCl2 through the perilymph in the rat, which provided an optimal method for the study of ME MRI of the auditory pathway in the animal model.