Utku Baran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Utku Baran has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Ruikang K. Wang
University of Washington
26 shared publications Yuandong Li
Department of Bioengineering, University of Washington, Seattle, WA, USA
10 shared publicationsHakan Urey
Koç University, Istanbul, Turkey
5 shared publicationsWan Qin
Department of Bioengineering, University of Washington, Seattle, WA, USA
5 shared publicationsDean Brown
Microvision Inc, Redmond, WA, USA
4 shared publicationsSven Holmstrom
Koç University, Istanbul, Turkey
4 shared publications
Latest Publications
- 22 May 2017
- Published by Wiley in Skin Research and Technology
- Vol. 24 (1) , 152-155
OCT‐based microangiography for reactive hyperaemia assessment within residual limb skin of people with lower limb loss
- 22 May 2017
- Published by Wiley in Skin Research and Technology
- Vol. 24 (1) , 152-155
OCT‐based microangiography for reactive hyperaemia assessment within residual limb skin of people with lower limb loss
- 1 December 2016
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 274, 164-171
Optical coherence tomography based microangiography provides an ability to longitudinally image arteriogenesis in vivo
- 1 December 2016
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 274, 164-171
Optical coherence tomography based microangiography provides an ability to longitudinally image arteriogenesis in vivo
- 1 December 2016
- Published by Wolters Kluwer Health in Stroke
- Vol. 47 (12) , 3014-3021
Impaired Collateral Flow Compensation During Chronic Cerebral Hypoperfusion in the Type 2 Diabetic Mice
Background and Purpose—: The presence of collaterals is associated with a reduced risk of stroke and transient ischemic attack in patients with steno-occlusive carotid artery disease. Although metabolic syndrome negatively impacts collateral status, it is unclear whether and to what extent type 2 diabetes mellitus affects cerebral collateral flow regulation during hypoperfusion. Methods—: We examined the spatial and temporal changes of the leptomeningeal collateral flow and the flow dynamics of the penetrating arterioles in the distal middle cerebral artery and anterior cerebral artery branches over 2 weeks after unilateral common carotid artery occlusion (CCAO) using optical coherent tomography in db/+ and db/db mice. We also assessed the temporal adaptation of the circle of Willis after CCAO by measuring circle of Willis vessel diameters. Results—: After unilateral CCAO, db/db mice exhibited diminished leptomeningeal collateral flow compensation compared with db /+ mice, which coincided with a reduced dilation of distal anterior cerebral artery branches, leading to reduced flow not only in pial vessels but also in penetrating arterioles bordering the distal middle cerebral artery and anterior cerebral artery. However, no apparent cell death was detected in either strain of mice during the first week after CCAO. db/db mice also experienced a more severe early reduction in the vessel diameters of several ipsilateral main feeding arteries in the circle of Willis, in addition to a delayed post-CCAO adaptive response by 1 to 2 weeks, compared with db/+ mice. Conclusions—: Type 2 diabetes mellitus is an additional risk factor for hemodynamic compromise during cerebral hypoperfusion, which may increase the severity and the risk of stroke or transient ischemic attack.
- 1 December 2016
- Published by Wolters Kluwer Health in Stroke
- Vol. 47 (12) , 3014-3021
Impaired Collateral Flow Compensation During Chronic Cerebral Hypoperfusion in the Type 2 Diabetic Mice
Background and Purpose—: The presence of collaterals is associated with a reduced risk of stroke and transient ischemic attack in patients with steno-occlusive carotid artery disease. Although metabolic syndrome negatively impacts collateral status, it is unclear whether and to what extent type 2 diabetes mellitus affects cerebral collateral flow regulation during hypoperfusion. Methods—: We examined the spatial and temporal changes of the leptomeningeal collateral flow and the flow dynamics of the penetrating arterioles in the distal middle cerebral artery and anterior cerebral artery branches over 2 weeks after unilateral common carotid artery occlusion (CCAO) using optical coherent tomography in db/+ and db/db mice. We also assessed the temporal adaptation of the circle of Willis after CCAO by measuring circle of Willis vessel diameters. Results—: After unilateral CCAO, db/db mice exhibited diminished leptomeningeal collateral flow compensation compared with db /+ mice, which coincided with a reduced dilation of distal anterior cerebral artery branches, leading to reduced flow not only in pial vessels but also in penetrating arterioles bordering the distal middle cerebral artery and anterior cerebral artery. However, no apparent cell death was detected in either strain of mice during the first week after CCAO. db/db mice also experienced a more severe early reduction in the vessel diameters of several ipsilateral main feeding arteries in the circle of Willis, in addition to a delayed post-CCAO adaptive response by 1 to 2 weeks, compared with db/+ mice. Conclusions—: Type 2 diabetes mellitus is an additional risk factor for hemodynamic compromise during cerebral hypoperfusion, which may increase the severity and the risk of stroke or transient ischemic attack.
- Open Access
- 7 September 2016
- Published by Wiley in Journal of Biophotonics
- Vol. 10 (11) , 1421-1429
Tail artifact removal in OCT angiography images of rodent cortex
Optical coherence tomography angiography (OCTA) is a surging non‐invasive, label‐free, in vivo volumetric imaging method, currently being translated to clinical ophthalmology and becoming popular in neuroscience. Despite its attractiveness, there is an inherent issue of using OCT angiograms for quantitative cerebrovascular studies: The dynamic scattering of moving erythrocytes within pial vasculature creates tail‐like artifacts that shadow the capillary vessels in the deeper layers of cortex. This false flow effect is relatively benign for qualitative visualization purposes, but it might have a significant impact on quantitative interpretation of angiographic results. In this work, we propose a simple image processing method to remove these tail artifacts in depth‐resolved OCTA images using an adaptive enface mask generated with OCT structural images. We demonstrate the effectiveness of our method by comparing vessel densities and vessel similarities of depth‐resolved OCT angiograms in a stroke study in a rodent model, in vivo. Thanks to the ability of seeing through the tails of pial vessels, capillary vessels beneath these vessels could be recovered to some extend in the deeper layers of mouse cerebral cortex, leading to a more accurate quantification. Tail artifact removed enface OCT angiogram of deeper layer in vivo mouse cortex. magnified image Tail artifact removed enface OCT angiogram of deeper layer in vivo mouse cortex.
- 7 September 2016
- Published by Wiley in Journal of Biophotonics
- Vol. 10 (11) , 1421-1429
Open AccessTail artifact removal in OCT angiography images of rodent cortex
Optical coherence tomography angiography (OCTA) is a surging non‐invasive, label‐free, in vivo volumetric imaging method, currently being translated to clinical ophthalmology and becoming popular in neuroscience. Despite its attractiveness, there is an inherent issue of using OCT angiograms for quantitative cerebrovascular studies: The dynamic scattering of moving erythrocytes within pial vasculature creates tail‐like artifacts that shadow the capillary vessels in the deeper layers of cortex. This false flow effect is relatively benign for qualitative visualization purposes, but it might have a significant impact on quantitative interpretation of angiographic results. In this work, we propose a simple image processing method to remove these tail artifacts in depth‐resolved OCTA images using an adaptive enface mask generated with OCT structural images. We demonstrate the effectiveness of our method by comparing vessel densities and vessel similarities of depth‐resolved OCT angiograms in a stroke study in a rodent model, in vivo. Thanks to the ability of seeing through the tails of pial vessels, capillary vessels beneath these vessels could be recovered to some extend in the deeper layers of mouse cerebral cortex, leading to a more accurate quantification. Tail artifact removed enface OCT angiogram of deeper layer in vivo mouse cortex. magnified image Tail artifact removed enface OCT angiogram of deeper layer in vivo mouse cortex.
- 17 June 2016
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 270, 132-137
Automated segmentation and enhancement of optical coherence tomography-acquired images of rodent brain
- 17 June 2016
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 270, 132-137
Automated segmentation and enhancement of optical coherence tomography-acquired images of rodent brain
- 27 April 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9689, 96890
Optical coherence tomography based microangiography: A tool good for dermatology applications (Conference Presentation)
Optical coherence tomography (OCT) based microangiography (OMAG) is a new imaging technique enabling the visualization of blood flow within microcirculatory tissue beds in vivo with high resolution. In this talk, the concept and advantages of OMAG will be discussed and its potential clinical applications in the dermatology will be shown, demonstrating its usefulness in the clinical monitoring and therapeutic treatment of various skin pathologies, e.g. acne, port wine stain and wound healing. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
- 27 April 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9689, 96890
Optical coherence tomography based microangiography: A tool good for dermatology applications (Conference Presentation)
Optical coherence tomography (OCT) based microangiography (OMAG) is a new imaging technique enabling the visualization of blood flow within microcirculatory tissue beds in vivo with high resolution. In this talk, the concept and advantages of OMAG will be discussed and its potential clinical applications in the dermatology will be shown, demonstrating its usefulness in the clinical monitoring and therapeutic treatment of various skin pathologies, e.g. acne, port wine stain and wound healing. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
- 1 April 2016
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 55 (4) , 040503
Video-rate volumetric optical coherence tomography-based microangiography
Video-rate volumetric optical coherence tomography (vOCT) is relatively young in the field of OCT imaging but has great potential in biomedical applications. Due to the recent development of the MHz range swept laser sources, vOCT has started to gain attention in the community. Here, we report the first in vivo video-rate volumetric OCT-based microangiography (vOMAG) system by integrating an 18-kHz resonant microelectromechanical system (MEMS) mirror with a 1.6-MHz FDML swept source operating at wavelength. Because the MEMS scanner can offer an effective B-frame rate of 36 kHz, we are able to engineer vOMAG with a video rate up to 25 Hz. This system was utilized for real-time volumetric in vivo visualization of cerebral microvasculature in mice. Moreover, we monitored the blood perfusion dynamics during stimulation within mouse ear in vivo. We also discussed this system’s limitations. Prospective MEMS-enabled OCT probes with a real-time volumetric functional imaging capability can have a significant impact on endoscopic imaging and image-guided surgery applications.- 1 April 2016
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 55 (4) , 040503
Video-rate volumetric optical coherence tomography-based microangiography
Video-rate volumetric optical coherence tomography (vOCT) is relatively young in the field of OCT imaging but has great potential in biomedical applications. Due to the recent development of the MHz range swept laser sources, vOCT has started to gain attention in the community. Here, we report the first in vivo video-rate volumetric OCT-based microangiography (vOMAG) system by integrating an 18-kHz resonant microelectromechanical system (MEMS) mirror with a 1.6-MHz FDML swept source operating at wavelength. Because the MEMS scanner can offer an effective B-frame rate of 36 kHz, we are able to engineer vOMAG with a video rate up to 25 Hz. This system was utilized for real-time volumetric in vivo visualization of cerebral microvasculature in mice. Moreover, we monitored the blood perfusion dynamics during stimulation within mouse ear in vivo. We also discussed this system’s limitations. Prospective MEMS-enabled OCT probes with a real-time volumetric functional imaging capability can have a significant impact on endoscopic imaging and image-guided surgery applications.- Open Access
- 11 March 2016
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 21 (03) , 036005
Intervolume analysis to achieve four-dimensional optical microangiography for observation of dynamic blood flow
We demonstrate in vivo volumetric optical microangiography at by the use of 1.6 MHz Fourier domain mode-locking swept source optical coherence tomography and an effective 36 kHz microelectromechanical system (MEMS) scanner. We propose an intervolume analysis strategy to contrast the dynamic blood flow signal from the static tissue background. The proposed system is demonstrated by imaging cerebral blood flow in mice in vivo. For the first time, imaging speed, sensitivity, and temporal resolution become possible for a direct four-dimensional observation of microcirculations within live body parts.- 11 March 2016
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 21 (03) , 036005
Open AccessIntervolume analysis to achieve four-dimensional optical microangiography for observation of dynamic blood flow
We demonstrate in vivo volumetric optical microangiography at by the use of 1.6 MHz Fourier domain mode-locking swept source optical coherence tomography and an effective 36 kHz microelectromechanical system (MEMS) scanner. We propose an intervolume analysis strategy to contrast the dynamic blood flow signal from the static tissue background. The proposed system is demonstrated by imaging cerebral blood flow in mice in vivo. For the first time, imaging speed, sensitivity, and temporal resolution become possible for a direct four-dimensional observation of microcirculations within live body parts. - 9 March 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9690, 96900J-96900J-5
Application of optical coherence tomography based microangiography for cerebral imaging
- 9 March 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9690, 96900J-96900J-5
Application of optical coherence tomography based microangiography for cerebral imaging
- 8 March 2016
- Published by SPIE-Intl Soc Optical Eng
- p. 969725-969725-4
OCT-based in vivo tissue injury mapping
- 8 March 2016
- Published by SPIE-Intl Soc Optical Eng
- p. 969725-969725-4
OCT-based in vivo tissue injury mapping