Karlo Nad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Karlo Nad has a total of 125 co-authors. Here are the top co-authors by number of shared publications:
Robert Kollar
Advanced Energy Ltd., Zagreb, Croatia
16 shared publicationsD. Sudac
15 shared publicationsV. Valkovic
13 shared publicationsVladivoj Valkovic
Analysis & Control Technologies, A.C.T.d.o.o., Prilesje 4, Zagreb, Croatia
10 shared publicationsJasmina Obhodas
Ruder Bošković Institute, Zagreb, Croatia
8 shared publications- Visnja Orescanin
Oreščanin Ltd
8 shared publications
Latest Publications
- 23 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (6) , 2287-2296
Onboard ROV Detection of Explosives and Narcotics Using Pulsed Fast Neutron Beams
This paper presents the Concealed Material Identification Module (CMIM), a novel system for real-time, underwater detection and identification of explosives and narcotics. CMIM is a Remotely Operated Vehicle (ROV) attachable module that utilizes a pulsed neutron generator for neutron activation analysis. It has been developed as part of the EU Horizon UnderSec project, which focuses on a multi-layered strategy for underwater threat detection. The system determines the elemental composition of potential threats by analysing (1) prompt inelastic scattering gamma rays during pulses, (2) prompt radiative capture gamma rays between pulses, and (3) delayed deactivation gamma rays, either between pulses, after the decrease of the capture gamma-ray signal, or after irradiation. CMIM specifically targets the high nitrogen content characteristic of many explosives and narcotics. The high penetrating power of fast neutrons enables identification of these hazardous materials, even when they are immersed in water, concealed or aged. This research details the CMIM's design and methodology, followed by an analysis of laboratory experiments conducted in a water basin to simulate realistic operational conditions. The results clearly show that the system is capable of detecting and distinguishing various concealed explosives and narcotic substances based on their unique elemental composition. The findings underscore CMIM's significant potential as a tool for rapid in-situ assessment of underwater and hull-borne threats in maritime security operations. In the next phase of the project, the module will be tested in a real operational environment.
- 23 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (6) , 2287-2296
Onboard ROV Detection of Explosives and Narcotics Using Pulsed Fast Neutron Beams
This paper presents the Concealed Material Identification Module (CMIM), a novel system for real-time, underwater detection and identification of explosives and narcotics. CMIM is a Remotely Operated Vehicle (ROV) attachable module that utilizes a pulsed neutron generator for neutron activation analysis. It has been developed as part of the EU Horizon UnderSec project, which focuses on a multi-layered strategy for underwater threat detection. The system determines the elemental composition of potential threats by analysing (1) prompt inelastic scattering gamma rays during pulses, (2) prompt radiative capture gamma rays between pulses, and (3) delayed deactivation gamma rays, either between pulses, after the decrease of the capture gamma-ray signal, or after irradiation. CMIM specifically targets the high nitrogen content characteristic of many explosives and narcotics. The high penetrating power of fast neutrons enables identification of these hazardous materials, even when they are immersed in water, concealed or aged. This research details the CMIM's design and methodology, followed by an analysis of laboratory experiments conducted in a water basin to simulate realistic operational conditions. The results clearly show that the system is capable of detecting and distinguishing various concealed explosives and narcotic substances based on their unique elemental composition. The findings underscore CMIM's significant potential as a tool for rapid in-situ assessment of underwater and hull-borne threats in maritime security operations. In the next phase of the project, the module will be tested in a real operational environment.
- 15 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (5) , 1109-1115
Development of a Neutron-Based Method for Onsite Fuel Inspection
Up to 20% of ethanol, base oil, or gas condensates are sometimes illegally added with the purpose to produce a cheaper fuel at the expense of its quality. Fuels are more expensive compared to the additives mentioned above due to the excise taxes and duties levied. Common customs procedures include random fuel sampling, where the tanks of trucks are opened at border crossings to verify that the cargo complies with customs declarations. Although some rapid on-site testing is available, very often more detailed laboratory analysis of fuel samples is required, the results of which may not be available for several days. We have investigated the possibility of using a neutron-based system to determine the elemental composition and density of gasoline, diesel, and various fuel blends such as gasoline/ethanol, diesel/base oil, and diesel/gas condensate. It has been shown that using the associate particle imaging method (API), it is possible to analyze elemental composition and density of different fuel types and various kinds of fuel blends on-site, without opening fuel tanks and slowing down border traffic. These analyses can be performed in addition to the already well-developed API method for on-site cargo inspection of illicit materials such as narcotics and explosives.
- 15 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (5) , 1109-1115
Development of a Neutron-Based Method for Onsite Fuel Inspection
Up to 20% of ethanol, base oil, or gas condensates are sometimes illegally added with the purpose to produce a cheaper fuel at the expense of its quality. Fuels are more expensive compared to the additives mentioned above due to the excise taxes and duties levied. Common customs procedures include random fuel sampling, where the tanks of trucks are opened at border crossings to verify that the cargo complies with customs declarations. Although some rapid on-site testing is available, very often more detailed laboratory analysis of fuel samples is required, the results of which may not be available for several days. We have investigated the possibility of using a neutron-based system to determine the elemental composition and density of gasoline, diesel, and various fuel blends such as gasoline/ethanol, diesel/base oil, and diesel/gas condensate. It has been shown that using the associate particle imaging method (API), it is possible to analyze elemental composition and density of different fuel types and various kinds of fuel blends on-site, without opening fuel tanks and slowing down border traffic. These analyses can be performed in addition to the already well-developed API method for on-site cargo inspection of illicit materials such as narcotics and explosives.
- 7 May 2022
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 200
Temporal and spatial resolution of the neutron probe for C/O nuclear well logging
- 7 May 2022
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 200
Temporal and spatial resolution of the neutron probe for C/O nuclear well logging
- 13 February 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 62 (2) , 407-414
New Neutron Log for Small Scale Variations in Carbon/Oxygen Ratio
The aim of the research reported here is the development of a methodology for the measurement of small scale variations in chemical elements concentrations, in particular of carbon to oxygen ratio. Knowledge of the C/O ratio is of importance to many problems in various fields. Here we single out the application in obtaining important information about the oilfields. The most fundamental reservoir parameters-oil, gas and water content-are critical factors in determining how each oilfield should be developed. It is well established that carbon to oxygen ratio log yields accurate and repeatable data that can be used to identify and monitor reserves depletion. Recent improvements in neutron generator and gamma detector technologies resulted in small devices which allowed through-tubing measurements. Although the ratio of carbon and oxygen yields is a measure of the amount of oil around the tool it should be realized that a carbon signal can originate from several sources including the borehole, the cement behind the casing, the formation rock and the formation fluid. In order to evaluate these contributions individually we are proposing the modification of the neutron generator by insertion of segmented associated alpha particle detector. From the measurement of neutron time of flight spectra (alpha particle detector-start signal; gamma ray detector-stop signal) it would be possible to determine the location of gamma-ray production voxel and in such a way to determine radial variations in chemical elements concentrations, in particular of C/O ratio.
- 13 February 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 62 (2) , 407-414
New Neutron Log for Small Scale Variations in Carbon/Oxygen Ratio
The aim of the research reported here is the development of a methodology for the measurement of small scale variations in chemical elements concentrations, in particular of carbon to oxygen ratio. Knowledge of the C/O ratio is of importance to many problems in various fields. Here we single out the application in obtaining important information about the oilfields. The most fundamental reservoir parameters-oil, gas and water content-are critical factors in determining how each oilfield should be developed. It is well established that carbon to oxygen ratio log yields accurate and repeatable data that can be used to identify and monitor reserves depletion. Recent improvements in neutron generator and gamma detector technologies resulted in small devices which allowed through-tubing measurements. Although the ratio of carbon and oxygen yields is a measure of the amount of oil around the tool it should be realized that a carbon signal can originate from several sources including the borehole, the cement behind the casing, the formation rock and the formation fluid. In order to evaluate these contributions individually we are proposing the modification of the neutron generator by insertion of segmented associated alpha particle detector. From the measurement of neutron time of flight spectra (alpha particle detector-start signal; gamma ray detector-stop signal) it would be possible to determine the location of gamma-ray production voxel and in such a way to determine radial variations in chemical elements concentrations, in particular of C/O ratio.
- 5 May 2014
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 49 (9) , 1007-1014
Removal of arsenic, phosphates and ammonia from well water using electrochemical/chemical methods and advanced oxidation: A pilot plant approach
The purpose of this work was to develop a pilot plant purification system and apply it to groundwater used for human consumption, containing high concentrations of arsenic and increased levels of phosphates, ammonia, mercury and color. The groundwater used was obtained from the production well in the Vinkovci County (Eastern Croatia). Due to a complex composition of the treated water, the purification system involved a combined electrochemical treatment, using iron and aluminum electrode plates with simultaneous ozonation, followed by a post-treatment with UV, ozone and hydrogen peroxide. The removal of the contaminant with the waste sludge collected during the electrochemical treatment was also tested. The combined electrochemical and advanced oxidation treatment resulted in the complete removal of arsenic, phosphates, color, turbidity, suspended solids and ammonia, while the removal of other contaminants of interest was up to 96.7%. Comparable removal efficiencies were obtained by using waste sludge as a coagulant.
- 5 May 2014
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 49 (9) , 1007-1014
Removal of arsenic, phosphates and ammonia from well water using electrochemical/chemical methods and advanced oxidation: A pilot plant approach
The purpose of this work was to develop a pilot plant purification system and apply it to groundwater used for human consumption, containing high concentrations of arsenic and increased levels of phosphates, ammonia, mercury and color. The groundwater used was obtained from the production well in the Vinkovci County (Eastern Croatia). Due to a complex composition of the treated water, the purification system involved a combined electrochemical treatment, using iron and aluminum electrode plates with simultaneous ozonation, followed by a post-treatment with UV, ozone and hydrogen peroxide. The removal of the contaminant with the waste sludge collected during the electrochemical treatment was also tested. The combined electrochemical and advanced oxidation treatment resulted in the complete removal of arsenic, phosphates, color, turbidity, suspended solids and ammonia, while the removal of other contaminants of interest was up to 96.7%. Comparable removal efficiencies were obtained by using waste sludge as a coagulant.
- 5 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 61 (4) , 2195-2203
Improved System for Inspecting Minefields and Residual Explosives
A next generation system, as an upgrade of a robotic mobile system for anti-personnel landmine clearance, was considered. In contrast to the first generation system where the fast neutron activation method and the associated alpha particle imaging (API) was supposed to be used for finding the residual explosives and/or landmines, in the next generation system fast neutrons (FN) was considered to be used only for the confirmation of the explosive in the suspected object previously found by the ground penetrating radar (GPR), metal detector (MD) and infrared imaging (IR). Such system is expected to have the acceptable price and the optimal demining vehicle speed of 10 cm/s. In contrast to the previous system only one neutron generator (NG) is needed. In order to study the possibility of FN to confirm the presence of TNT explosive in the real environment the tests were made with the soil of different moisture contents. Comparative study was done by using the 7.62 cm × 7.62 cm BGO, 7.62 cm × 7.62 cm LaBr 3 : Ce and 7.62 cm × 7.62 cm NaI(Tl) gamma-ray detectors. Although nitrogen was easily detected in larger amount of TNT explosive, its signal was weak in detection of Anti-Personal (AP) mine like DLM2.4. The presences of soil additionally diminish the possibility of nitrogen detection even in the Anti-Tank mines (AT).
- 5 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 61 (4) , 2195-2203
Improved System for Inspecting Minefields and Residual Explosives
A next generation system, as an upgrade of a robotic mobile system for anti-personnel landmine clearance, was considered. In contrast to the first generation system where the fast neutron activation method and the associated alpha particle imaging (API) was supposed to be used for finding the residual explosives and/or landmines, in the next generation system fast neutrons (FN) was considered to be used only for the confirmation of the explosive in the suspected object previously found by the ground penetrating radar (GPR), metal detector (MD) and infrared imaging (IR). Such system is expected to have the acceptable price and the optimal demining vehicle speed of 10 cm/s. In contrast to the previous system only one neutron generator (NG) is needed. In order to study the possibility of FN to confirm the presence of TNT explosive in the real environment the tests were made with the soil of different moisture contents. Comparative study was done by using the 7.62 cm × 7.62 cm BGO, 7.62 cm × 7.62 cm LaBr 3 : Ce and 7.62 cm × 7.62 cm NaI(Tl) gamma-ray detectors. Although nitrogen was easily detected in larger amount of TNT explosive, its signal was weak in detection of Anti-Personal (AP) mine like DLM2.4. The presences of soil additionally diminish the possibility of nitrogen detection even in the Anti-Tank mines (AT).
- 1 December 2013
- Published by Elsevier in Radiation Measurements
- Vol. 59, 193-200
Monitoring of concrete structures by using the 14 MeV tagged neutron beams
- 1 December 2013
- Published by Elsevier in Radiation Measurements
- Vol. 59, 193-200
Monitoring of concrete structures by using the 14 MeV tagged neutron beams
- 26 June 2013
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 48 (12) , 1543-1547
Treatment of winery wastewater by electrochemical methods and advanced oxidation processes
The aim of this research was development of new system for the treatment of highly polluted wastewater (COD = 10240 mg/L; SS = 2860 mg/L) originating from vine-making industry. The system consisted of the main treatment that included electrochemical methods (electro oxidation, electrocoagulation using stainless steel, iron and aluminum electrode sets) with simultaneous sonication and recirculation in strong electromagnetic field. Ozonation combined with UV irradiation in the presence of added hydrogen peroxide was applied for the post-treatment of the effluent. Following the combined treatment, the final removal efficiencies of the parameters color, turbidity, suspended solids and phosphates were over 99%, Fe, Cu and ammonia approximately 98%, while the removal of COD and sulfates was 77% and 62%, respectively. A new approach combining electrochemical methods with ultrasound in the strong electromagnetic field resulted in significantly better removal efficiencies for majority of the measured parameters compared to the biological methods, advanced oxidation processes or electrocoagulation. Reduction of the treatment time represents another advantage of this new approach.
- 26 June 2013
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 48 (12) , 1543-1547
Treatment of winery wastewater by electrochemical methods and advanced oxidation processes
The aim of this research was development of new system for the treatment of highly polluted wastewater (COD = 10240 mg/L; SS = 2860 mg/L) originating from vine-making industry. The system consisted of the main treatment that included electrochemical methods (electro oxidation, electrocoagulation using stainless steel, iron and aluminum electrode sets) with simultaneous sonication and recirculation in strong electromagnetic field. Ozonation combined with UV irradiation in the presence of added hydrogen peroxide was applied for the post-treatment of the effluent. Following the combined treatment, the final removal efficiencies of the parameters color, turbidity, suspended solids and phosphates were over 99%, Fe, Cu and ammonia approximately 98%, while the removal of COD and sulfates was 77% and 62%, respectively. A new approach combining electrochemical methods with ultrasound in the strong electromagnetic field resulted in significantly better removal efficiencies for majority of the measured parameters compared to the biological methods, advanced oxidation processes or electrocoagulation. Reduction of the treatment time represents another advantage of this new approach.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Small scale variations in carbon oxygen ratio
The aim of the research reported here is the development of a methodology for the measurement of small scale variations in chemical elements concentrations, in particular of carbon - oxygen ratio. Knowledge of the C/O ratio is of importance to many problems in various fields. Here we single out the application in obtaining important information about the oilfields. The most fundamental reservoir parameters - oil, gas and water content - are critical factors in determining how each oilfield should be developed. It is well established that carbon to oxygen ratio log yields accurate and repeatable data that can be used to identify and monitor reserves depletion. Recent improvements in neutron generator and gamma detector technologies resulted in small devices which allowed through-tubing measurements. Although the ratio of carbon and oxygen yields is a measure of the ammount of oil arround the tool it should be realized that a carbon signal can originate from several sources including the borehole, the cement behind the casing, the formation rock and the formation fluid. In order to evaluate these contributions individualy we are proposing the modification of the neutron generator by insertion of segmented associated alpha particle detector. From the measurement of time of flight spectra (alpha particle detector - start signal; gamma ray detector - stop signal) it would be possible to determine the location of gamma ray producing voxel and in such a way to determine radial variations in several chemical elements concentrations, in particular of carbon to oxygen ratio.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Small scale variations in carbon oxygen ratio
The aim of the research reported here is the development of a methodology for the measurement of small scale variations in chemical elements concentrations, in particular of carbon - oxygen ratio. Knowledge of the C/O ratio is of importance to many problems in various fields. Here we single out the application in obtaining important information about the oilfields. The most fundamental reservoir parameters - oil, gas and water content - are critical factors in determining how each oilfield should be developed. It is well established that carbon to oxygen ratio log yields accurate and repeatable data that can be used to identify and monitor reserves depletion. Recent improvements in neutron generator and gamma detector technologies resulted in small devices which allowed through-tubing measurements. Although the ratio of carbon and oxygen yields is a measure of the ammount of oil arround the tool it should be realized that a carbon signal can originate from several sources including the borehole, the cement behind the casing, the formation rock and the formation fluid. In order to evaluate these contributions individualy we are proposing the modification of the neutron generator by insertion of segmented associated alpha particle detector. From the measurement of time of flight spectra (alpha particle detector - start signal; gamma ray detector - stop signal) it would be possible to determine the location of gamma ray producing voxel and in such a way to determine radial variations in several chemical elements concentrations, in particular of carbon to oxygen ratio.