HKHans Kottkamp

Hans Kottkamp

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hans Kottkamp has a total of 62 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Pulsed field ablation: The pitfall of remote stunning or the importance of contact and contiguity

    by Hans Kottkamp, Carlos Felipe Antepara Amador, Lea Melki, Laura Shenavai, Burghard Schumacher


  • Global multielectrode contact‐mapping plus ablation with a single catheter in patients with atrial fibrillation: Global AF study

    by Hans Kottkamp, Gerhard Hindricks, Christian Pönisch, Livio Bertagnolli, Fabian Moser, Sebastian Hilbert, Andreas Rieger, Philipp Sommer

    Introduction: The critical question for technological advancement of catheter ablation of atrial fibrillation (AF) is whether a creative new concept can combine and even improve the options of single‐tip catheters with the simplicity of the use of balloon catheters. Herein are described the results from the first clinical study of a new multielectrode contact‐mapping plus ablation array (Globe) offering such a complete solution.Methods and Results: The multielectrode Globe array consists of 16 flat ribs with 122 gold‐plated electrodes. Each electrode can record electrograms, ablate, pace, and can measure tissue contact and temperature. Single‐shot pulmonary vein isolation (PVI) is possible with temperature‐guided ablation of up to 24 electrodes simultaneously with automatic, individual power control of every electrode. Sixty patients with symptomatic AF underwent PVI using the Globe. In all sixty patients, acute PVI was achieved in 232 of 234 attempted PVs (99.1%). In 34 patients treated with “single‐hot‐shot” ablation, PVI was achieved in 136 of 136 PVs (100%). Single‐procedure 12‐month freedom from AF off antiarrhythmic drugs in the “single‐hot‐shot” group was 75.5% and freedom from AF/atrial tachycardia 72.3%. In two patients, pericardial tamponade was observed, one after a transseptal puncture, and one during array insertion with an over‐advanced sheath. There were no other device‐related serious adverse events, including stroke, PV stenosis, esophageal perforation, or phrenic nerve palsy.Conclusions: In this first clinical series, the Globe catheter was found to be an easy‐to‐use system for single‐shot PVI. The continuously updated multielectrode voltage and activation mapping data indicate future options for mapping and ablation beyond PVI.


  • On the Atrial Fibrillation Substrate

    by Hans Kottkamp


  • A novel ablation approach in atrial fibrillation patients undergoing fibrotic‐based substrate modification: Targeting the Bachmann's bundle?

    by Fabian Moser, Andreas Rieger, Christian Pönisch, Hans Kottkamp

    Introduction: Box isolation of fibrotic areas (BIFA) is a promising ablation approach for atrial fibrillation (AF) patients. However, complete isolation of fibrotic anteroseptal left atrial area, where Bachmann's bundle is blending into the left atrial myocardium, is very specific and complex.Methods and results: In 34 AF patients with anteroseptal fibrosis, circumferential BIFA was performed in addition to pulmonary vein isolation. In 8 of 34 patients, complete isolation of the fibrotic area was achieved with BIFA alone. In 26 of 34 patients, a decrease in voltage amplitude with or without conduction delay was observed after box ablation but no complete isolation. Activation mapping and characteristic unipolar potentials revealed earliest activation inside the box from one (73%), two (15%), or three (12%) remaining inputs, in the region of Bachmann's bundle insertion. Focal ablation inside the box (mean radiofrequency impulses: 1.7 ± 0.4, mean radiofrequency time: 70 ± 19 seconds) led to complete isolation of the fibrotic area in 25 of 26 patients. Overall, 97% of anteroseptal boxes were completely isolated with additional focal ablation in the study group compared to 21% in the control group with BIFA alone (33/34 vs. 7/34, P < 0.001). Time of left atrial activation decreased significantly by 25% after complete box isolation (P < 0.001). After a single procedure, 12‐month arrhythmia‐free survival was 82% with additional focal ablation compared to 71% in the control group (P = 0.2).Conclusion: Targeted and focal ablation in the region of Bachmann's bundle is a novel and feasible technique to achieve complete isolation of the left atrial anteroseptal fibrotic area.


  • Open Access

    Box Isolation of fibrotic areas: A substrate modification approach in atrial fibrillation patients

    by Fabian Moser, Doreen Schreiber, Andreas Rieger, Monica Trofin, Christian Pönisch, Hans Kottkamp


  • Global multielectrode contact mapping plus ablation with a single catheter: Preclinical and preliminary experience in humans with atrial fibrillation

    by Hans Kottkamp, Fabian Moser, Andreas Rieger, Doreen Schreiber, Christian Pönisch, Monica Trofin

    Introduction: One question for the technological advancement of catheter ablation of atrial fibrillation (AF) is whether a creative new concept can combine and even improve the diagnostic mapping options of single‐tip and basket catheters with the simplicity of the use of balloon catheters for ablation. Herein, we describe the first in‐human experience with a single catheter offering such a complete solution.Methods and results: A new catheter (Globe®) with a distal multielectrode array consisting of 16 ribs with 122 gold‐plated electrodes was used. Each electrode can ablate, pace, and can measure tissue contact, temperature, current, and intracardiac electrograms. The Globe was deployed and removed without difficulty in all 3 patients. Complete pulmonary vein isolation (PVI) was achieved in all 12 veins. In 10 veins, PVI was achieved with a single placement in front of the respective vein (“single circle isolation”). In one subject, the device was repositioned due to the esophagus location. In the other subject, a single gap was observed after circumferential ablation of the right inferior PV. After precise gap identification, the device was adjusted slightly for improved contact at that region, and reablation resulted in immediate PVI.Conclusions: PVI isolation could be performed with the new multielectrode array Globe in all 12 PVs offering the option for easy handling and fast “single‐shot” PVI. Several continuously updated mapping types from 122 electrodes even in real time during ablation demonstrate the capability to go beyond PVI for voltage mapping plus substrate modification, and for rotor mapping plus rotor ablation.


  • Catheter ablation of atrial fibrillation with box isolation of fibrotic areas: Lessons on fibrosis distribution and extent, clinical characteristics, and their impact on long‐term outcome

    by Doreen Schreiber, Andreas Rieger, Fabian Moser, Hans Kottkamp

    Introduction: The BIFA concept (box isolation of fibrotic areas) supplementing pulmonary vein isolation (PVI) was implemented in atrial fibrillation (AF) patients with fibrotic atrial cardiomyopathy (FACM) to improve catheter ablation outcomes.Methods and results: Ninety‐two patients with FACM underwent PVI + BIFA. We investigated patient characteristics (58 persistent/34 paroxysmal, 68 ± 8 years, LA 44 ± 7 mm, CHA2DS2‐VASc 2.6 ± 1.3, FACM I: 15.2%, II: 53.3%, III: 26.1%, IV: 5.4%), periprocedural data concerning fibrosis extent/distribution, and their impact on outcome.Based on severe fibrosis areas (SFAs) of 13.5 ± 13.9 cm2 detected by voltage mapping, 1.4 ± 0.5 boxes (n = 1–3, 2.2–35.3 cm2) were applied in the left atrium. With higher grade FACM, SFAs increased and maximum voltage decreased (I/IV: 6.29/3.18 mV). Anterior (ant.) SFAs were found to be more common and larger than posterior (post.) SFAs (58.3% vs. 42.6%, ant. 8.0 ± 8.0 vs. post. 4.7 ± 6.8 cm2). In 40 of 92 (43%) patients, both atrial walls were affected with rare cases of solely post. fibrosis (6 of 92, 6.6%).Women (39 of 92, 42%) showed FACM III+IV more often than men (P = 0.022) and can still present paroxysmal while persistent males are more likely to have FACM I‐II. Single and multiple procedure (1.2/patient) success was 69% and 83% after 16 ± 8 months with an unfavorable impact of large SFA size, both‐sided fibrosis and reduced maximum voltage, independently of patient characteristics and AF type.Conclusion: FACM patients are a challenging AF subgroup for catheter ablation. Women seem to show FACM III+IV more often than men. The distribution of left atrial fibrosis is variable but more pronounced anteriorly. Atrial disease is characterized by SFA size but also maximum voltage reduction, both with implications on ablation outcome. Using BIFA, success rates of patients without fibrosis can be approached but are limited in FACM III+IV.


  • Therapeutic Approaches to Atrial Fibrillation Ablation Targeting Atrial Fibrosis

    by Hans Kottkamp, Doreen Schreiber, Fabian Moser, Andreas Rieger


  • Box Isolation of Fibrotic Areas (BIFA): A Patient‐Tailored Substrate Modification Approach for Ablation of Atrial Fibrillation

    by Hans Kottkamp, Jan Berg, Roderich Bender, Andreas Rieger, Doreen Schreiber

    Substrate Modification BIFA in AF Ablation: Background: Catheter ablation strategies beyond pulmonary vein isolation (PVI) for treatment of atrial fibrillation (AF) are less well defined. Increasing clinical data indicate that atrial fibrosis is a critical common left atrial (LA) substrate in AF patients (pts).Objective: We applied a new substrate modification concept according to the individual fibrotic substrate as estimated from electroanatomic voltage mapping (EAVM) in 41 pts undergoing catheter ablation of AF.Results: First, EAVM during sinus rhythm was done in redo cases of 10 pts with paroxysmal AF despite durable PVI. Confluent low‐voltage areas (LVA) were found in all pts and were targeted with circumferential isolation, so‐called box isolation of fibrotic areas (BIFA). This strategy led to stable sinus rhythm in 9/10 pts and was transferred prospectively to first procedures of 31 pts with nonparoxysmal AF. In 13 pts (42%), no LVA (<0.5 mV) were identified, and only PVI was performed. In 18 pts (58%), additional BIFA strategies were applied (posterior box in 5, anterior box in 7, posterior plus anterior box in 5, no box in 1 due to diffuse fibrosis). Mean follow‐up was 12.5 ± 2.4 months. Single‐procedure freedom from AF/atrial tachycardia was achieved in 72.2% of pts and in 83.3% of pts with 1.17 procedures/patient.Conclusions: In approximately 40% of pts with nonparoxysmal AF, no substantial LVA were identified, and PVI alone showed high success rate. In pts with paroxysmal AF despite durable PVI and in approximately 60% of pts with nonparoxysmal AF, individually localized LVA were identified and could be targeted successfully with the BIFA strategy.