Simanto Saha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Simanto Saha has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Khawza Iftekhar Uddin Ahmed
Department of Electrical and Electronic Engineering, United International University, Dhaka 1212, Bangladesh
11 shared publications - Ahsan Habib Khandoker
Department of Biomedical Engineering and Biotechnology Khalifa University Abu Dhabi United Arab Emirates
7 shared publications Raqibul Mostafa
School of Electrical and Electronic Engineering, The University of Adelaide, Adelaide, SA, Australia
7 shared publications- Mathias Baumert
Discipline of Biomedical Engineering, School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide, Australia
5 shared publications - Herbert Franz Jelinek
Department of Medical Sciences, Khalifa University, Abu Dhabi, United Arab Emirates
4 shared publications - Nayeefa Chowdhury
School of Psychological Sciences, Faculty of Medicine, Nursing and Health Sciences, Monash University, Clayton, Australia
4 shared publications
Latest Publications
- Open Access
- 5 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. PP, 1
Time-Domain Versus Frequency-Embedded EEG Sequences for Sensorimotor BCI Using 1D−CNN
This study proposed a motor imagery (MI) classification pipeline featuring a 1−dimensional convolutional neural network (1D-CNN) with different time/frequency feature representation techniques. The objective was to classify right hand (RH) versus right foot (RF) MI tasks in both intra- and inter-subject (pairwise and pooled) BCI settings using a 1D-CNN architecture trained on time-domain bandpass filtered electroencephalography (EEG) signals, frequency-embedded power spectral density (PSD) and cross-power spectral density (CPSD) sequences. The EEG signals were bandpass filtered with 4 Hz and 32 Hz cut-off frequencies, and PSD/CPSD sequences were estimated in the same frequency range. Thus, the number of input channels for 1D-CNN was N, N or N ×N for EEG signals, PSD or CPSD sequences. We used dataset IVa from BCI Competition III in 5−fold cross-validation settings to evaluate intra-subject, inter-subject (pairwise) and inter-subject (pooled) BCI classification accuracies. We compared the performance of the proposed methods with classification algorithms featuring common spatial patterns (CSP) for benchmarking. The best overall classification accuracies (%) for intra-subject, inter-subject (pairwise) and inter-subject (pooled) BCIs were 86.57±11.69, 70.80±9.21 and 76.61±12.37 using 1D−CNN with time-domain EEG signals. The average classification accuracies using 1D-CNN with frequency-embedded PSD sequences were 82.57±10.20, 69.32±7.46 and 71.32±7.96 for intra-subject, inter-subject (pairwise) and inter-subject (pooled) BCIs. The proposed time/frequency feature representation techniques with 1D-CNN outperformed CSP-based algorithms (p-value < 0.05). The comparative results suggest the utility of the proposed methods for MI classification, especially for a fully zero-training inter-subject BCI.
- 5 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. PP, 1
Open AccessTime-Domain Versus Frequency-Embedded EEG Sequences for Sensorimotor BCI Using 1D−CNN
This study proposed a motor imagery (MI) classification pipeline featuring a 1−dimensional convolutional neural network (1D-CNN) with different time/frequency feature representation techniques. The objective was to classify right hand (RH) versus right foot (RF) MI tasks in both intra- and inter-subject (pairwise and pooled) BCI settings using a 1D-CNN architecture trained on time-domain bandpass filtered electroencephalography (EEG) signals, frequency-embedded power spectral density (PSD) and cross-power spectral density (CPSD) sequences. The EEG signals were bandpass filtered with 4 Hz and 32 Hz cut-off frequencies, and PSD/CPSD sequences were estimated in the same frequency range. Thus, the number of input channels for 1D-CNN was N, N or N ×N for EEG signals, PSD or CPSD sequences. We used dataset IVa from BCI Competition III in 5−fold cross-validation settings to evaluate intra-subject, inter-subject (pairwise) and inter-subject (pooled) BCI classification accuracies. We compared the performance of the proposed methods with classification algorithms featuring common spatial patterns (CSP) for benchmarking. The best overall classification accuracies (%) for intra-subject, inter-subject (pairwise) and inter-subject (pooled) BCIs were 86.57±11.69, 70.80±9.21 and 76.61±12.37 using 1D−CNN with time-domain EEG signals. The average classification accuracies using 1D-CNN with frequency-embedded PSD sequences were 82.57±10.20, 69.32±7.46 and 71.32±7.96 for intra-subject, inter-subject (pairwise) and inter-subject (pooled) BCIs. The proposed time/frequency feature representation techniques with 1D-CNN outperformed CSP-based algorithms (p-value < 0.05). The comparative results suggest the utility of the proposed methods for MI classification, especially for a fully zero-training inter-subject BCI.
- Open Access
- 27 February 2025
- Published by Elsevier in Construction and Building Materials
- Vol. 470, 140516
Pulverised CFRP waste and reclaimed carbon fibre for cement-based sensors: Investigating electrical resistivity and piezoresistivity under varying environmental conditions
- 27 February 2025
- Published by Elsevier in Construction and Building Materials
- Vol. 470, 140516
Open AccessPulverised CFRP waste and reclaimed carbon fibre for cement-based sensors: Investigating electrical resistivity and piezoresistivity under varying environmental conditions
- Open Access
- 9 January 2025
- Published by Elsevier in Computers in Human Behavior Reports
- Vol. 17
Opinions on neural implants for children with cerebral palsy: A survey of the Australian cerebral palsy community
- 9 January 2025
- Published by Elsevier in Computers in Human Behavior Reports
- Vol. 17
Open AccessOpinions on neural implants for children with cerebral palsy: A survey of the Australian cerebral palsy community
- 14 November 2023
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 15 (1) , 52-64
Overcoming Uncertainties in Electrogram-Based Atrial Fibrillation Mapping: A Review
In clinical rhythmology, intracardiac bipolar electrograms (EGMs) play a critical role in investigating the triggers and substrates inducing and perpetuating atrial fibrillation (AF). However, the interpretation of bipolar EGMs is ambiguous due to several aspects of electrodes, mapping algorithms and wave propagation dynamics, so it requires several variables to describe the effects of these uncertainties on EGM analysis. In this narrative review, we critically evaluate the potential impact of such uncertainties on the design of cardiac mapping tools on AF-related substrate characterization. Literature suggest uncertainties are due to several variables, including the wave propagation vector, the wave’s incidence angle, inter-electrode spacing, electrode size and shape, and tissue contact. The preprocessing of the EGM signals and mapping density will impact the electro-anatomical representation and the features extracted from the local electrical activities. The superposition of multiple waves further complicates EGM interpretation. The inclusion of these uncertainties is a nontrivial problem but their consideration will yield a better interpretation of the intra-atrial dynamics in local activation patterns. From a translational perspective, this review provides a concise but complete overview of the critical variables for developing more precise cardiac mapping tools.
- 14 November 2023
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 15 (1) , 52-64
Overcoming Uncertainties in Electrogram-Based Atrial Fibrillation Mapping: A Review
In clinical rhythmology, intracardiac bipolar electrograms (EGMs) play a critical role in investigating the triggers and substrates inducing and perpetuating atrial fibrillation (AF). However, the interpretation of bipolar EGMs is ambiguous due to several aspects of electrodes, mapping algorithms and wave propagation dynamics, so it requires several variables to describe the effects of these uncertainties on EGM analysis. In this narrative review, we critically evaluate the potential impact of such uncertainties on the design of cardiac mapping tools on AF-related substrate characterization. Literature suggest uncertainties are due to several variables, including the wave propagation vector, the wave’s incidence angle, inter-electrode spacing, electrode size and shape, and tissue contact. The preprocessing of the EGM signals and mapping density will impact the electro-anatomical representation and the features extracted from the local electrical activities. The superposition of multiple waves further complicates EGM interpretation. The inclusion of these uncertainties is a nontrivial problem but their consideration will yield a better interpretation of the intra-atrial dynamics in local activation patterns. From a translational perspective, this review provides a concise but complete overview of the critical variables for developing more precise cardiac mapping tools.
- Top Cited PapersOpen Access
- 25 February 2021
- Published by Frontiers Media SA in Frontiers in Systems Neuroscience
- Vol. 15
Progress in Brain Computer Interface: Challenges and Opportunities
Brain computer interfaces (BCI) provide a direct communication link between the brain and a computer or other external devices. They offer an extended degree of freedom either by strengthening or by substituting human peripheral working capacity and have potential applications in various fields such as rehabilitation, affective computing, robotics, gaming, and neuroscience. Significant research efforts on a global scale have delivered common platforms for technology standardization and help tackle highly complex and non-linear brain dynamics and related feature extraction and classification challenges. Time-variant psycho-neurophysiological fluctuations and their impact on brain signals impose another challenge for BCI researchers to transform the technology from laboratory experiments to plug-and-play daily life. This review summarizes state-of-the-art progress in the BCI field over the last decades and highlights critical challenges.
- 25 February 2021
- Published by Frontiers Media SA in Frontiers in Systems Neuroscience
- Vol. 15
Top Cited PapersOpen AccessProgress in Brain Computer Interface: Challenges and Opportunities
Brain computer interfaces (BCI) provide a direct communication link between the brain and a computer or other external devices. They offer an extended degree of freedom either by strengthening or by substituting human peripheral working capacity and have potential applications in various fields such as rehabilitation, affective computing, robotics, gaming, and neuroscience. Significant research efforts on a global scale have delivered common platforms for technology standardization and help tackle highly complex and non-linear brain dynamics and related feature extraction and classification challenges. Time-variant psycho-neurophysiological fluctuations and their impact on brain signals impose another challenge for BCI researchers to transform the technology from laboratory experiments to plug-and-play daily life. This review summarizes state-of-the-art progress in the BCI field over the last decades and highlights critical challenges.
- Top Cited PapersOpen Access
- 21 January 2020
- Published by Frontiers Media SA in Frontiers in Computational Neuroscience
- Vol. 13, 87
Intra- and Inter-subject Variability in EEG-Based Sensorimotor Brain Computer Interface: A Review
Brain computer interfaces (BCI) for the rehabilitation of motor impairments exploit sensorimotor rhythms (SMR) in the electroencephalogram (EEG). However, the neurophysiological processes underpinning the SMR often vary over time and across subjects. Inherent intra- and inter-subject variability causes covariate shift in data distributions that impede the transferability of model parameters amongst sessions/subjects. Transfer learning includes machine learning-based methods to compensate for inter-subject and inter-session (intra-subject) variability manifested in EEG-derived feature distributions as a covariate shift for BCI. Besides transfer learning approaches, recent studies have explored psychological and neurophysiological predictors as well as inter-subject associativity assessment, which may augment transfer learning in EEG-based BCI. Here, we highlight the importance of measuring inter-session/subject performance predictors for generalized BCI frameworks for both normal and motor-impaired people, reducing the necessity for tedious and annoying calibration sessions and BCI training.
- 21 January 2020
- Published by Frontiers Media SA in Frontiers in Computational Neuroscience
- Vol. 13, 87
Top Cited PapersOpen AccessIntra- and Inter-subject Variability in EEG-Based Sensorimotor Brain Computer Interface: A Review
Brain computer interfaces (BCI) for the rehabilitation of motor impairments exploit sensorimotor rhythms (SMR) in the electroencephalogram (EEG). However, the neurophysiological processes underpinning the SMR often vary over time and across subjects. Inherent intra- and inter-subject variability causes covariate shift in data distributions that impede the transferability of model parameters amongst sessions/subjects. Transfer learning includes machine learning-based methods to compensate for inter-subject and inter-session (intra-subject) variability manifested in EEG-derived feature distributions as a covariate shift for BCI. Besides transfer learning approaches, recent studies have explored psychological and neurophysiological predictors as well as inter-subject associativity assessment, which may augment transfer learning in EEG-based BCI. Here, we highlight the importance of measuring inter-session/subject performance predictors for generalized BCI frameworks for both normal and motor-impaired people, reducing the necessity for tedious and annoying calibration sessions and BCI training.
- 30 December 2019
- Published by Computing in Cardiology
A Ventricular Far-field Artefact Filtering Technique for Atrial Electrograms
- 30 December 2019
- Published by Computing in Cardiology
A Ventricular Far-field Artefact Filtering Technique for Atrial Electrograms
- 1 October 2019
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 40 (Supplement)
P2843Impact of bipolar vector orientation and inter-electrode spacing on electrograms during human atrial fibrillation
Background: In patients with atrial fibrillation (AF), local atrial bipolar electrograms (EGM) are clinically used to determine peak-to-peak voltage (Vpp), dominant frequency (DF) and Shannon Entropy (ShEn) for electroanatomical substrate characterization and substrate-based ablation. The effect of bipolar vector orientation and inter-electrode spacing on these EGM-derived measures during AF is unclear. Methods: To quantify the impact of bipolar vector orientation and inter-electrode spacing, bipolar EGM (10,496 and 20,968 atrial sites, respectively) were reconstructed from unipolar EGM recorded with an array of 18 electrodes in 14 patients with persistent AF. We compared Vpp, DF and ShEn between any two adjacent bipolar vectors with a difference of 45 degree. Vpp, DF and ShEn values were ranked into different classes from highest to lowest value. To quantify the effect of inter-electrode spacing, bipolar EGM were constructed from electrodes spaced 4mm, 8mm, and 12mm apart, respectively. Results: First, bipolar vector orientation significantly impacts Vpp (maximal difference: 1.341±2.169 mV vs. 0.595±0.652 mV; p<0.01) and the percentage of atrial low voltage areas (Vpp<0.05mV) (maximal difference: 62.31% vs. 32.54%). Bipolar vector orientation also influences DF (maximal difference: 8.547±2.971 Hz vs. 6.360±1.077 Hz; p<0.01) and ShEn (maximal difference: 4.898±0.488 vs. 4.120±0.650; p<0.01) measurements. Second, inter-electrode spacing affects Vppincreasing from 0.854±1.299 mV to 1.013±1.302 mV for 4mm, and 12mm, respectively (p<0.01). The percentage of atrial low voltage areas differed between 53.77% and 42.03% for 4mm and 12mm, respectively. Furthermore, inter-electrode spacing alters DF (maximal difference: 7.316±2.239 Hz vs. 7.234±2.124 Hz; p<0.01) and ShEn (maximal difference: 4.364±0.714 vs. 4.514±0.624; p<0.01) measurements. Conclusions: Bipolar vector orientation and inter-electrode spacing both significantly affect bipolar EGM-derived measures that may result in significant uncertainty around the electroanatomical substrate characterization in AF patients, which should be considered in the development of future mapping catheter tools and algorithms.
- 1 October 2019
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 40 (Supplement)
P2843Impact of bipolar vector orientation and inter-electrode spacing on electrograms during human atrial fibrillation
Background: In patients with atrial fibrillation (AF), local atrial bipolar electrograms (EGM) are clinically used to determine peak-to-peak voltage (Vpp), dominant frequency (DF) and Shannon Entropy (ShEn) for electroanatomical substrate characterization and substrate-based ablation. The effect of bipolar vector orientation and inter-electrode spacing on these EGM-derived measures during AF is unclear. Methods: To quantify the impact of bipolar vector orientation and inter-electrode spacing, bipolar EGM (10,496 and 20,968 atrial sites, respectively) were reconstructed from unipolar EGM recorded with an array of 18 electrodes in 14 patients with persistent AF. We compared Vpp, DF and ShEn between any two adjacent bipolar vectors with a difference of 45 degree. Vpp, DF and ShEn values were ranked into different classes from highest to lowest value. To quantify the effect of inter-electrode spacing, bipolar EGM were constructed from electrodes spaced 4mm, 8mm, and 12mm apart, respectively. Results: First, bipolar vector orientation significantly impacts Vpp (maximal difference: 1.341±2.169 mV vs. 0.595±0.652 mV; p<0.01) and the percentage of atrial low voltage areas (Vpp<0.05mV) (maximal difference: 62.31% vs. 32.54%). Bipolar vector orientation also influences DF (maximal difference: 8.547±2.971 Hz vs. 6.360±1.077 Hz; p<0.01) and ShEn (maximal difference: 4.898±0.488 vs. 4.120±0.650; p<0.01) measurements. Second, inter-electrode spacing affects Vppincreasing from 0.854±1.299 mV to 1.013±1.302 mV for 4mm, and 12mm, respectively (p<0.01). The percentage of atrial low voltage areas differed between 53.77% and 42.03% for 4mm and 12mm, respectively. Furthermore, inter-electrode spacing alters DF (maximal difference: 7.316±2.239 Hz vs. 7.234±2.124 Hz; p<0.01) and ShEn (maximal difference: 4.364±0.714 vs. 4.514±0.624; p<0.01) measurements. Conclusions: Bipolar vector orientation and inter-electrode spacing both significantly affect bipolar EGM-derived measures that may result in significant uncertainty around the electroanatomical substrate characterization in AF patients, which should be considered in the development of future mapping catheter tools and algorithms.
- Open Access
- 23 July 2019
- Published by Frontiers Media SA in Frontiers in Neuroinformatics
- Vol. 13, 47
Wavelet Entropy-Based Inter-subject Associative Cortical Source Localization for Sensorimotor BCI
We propose event-related cortical sources estimation from subject-independent electroencephalography (EEG) recordings for motor imagery brain computer interface (BCI). By using wavelet-based maximum entropy on the mean (wMEM), task-specific EEG channels are selected to predict right hand and right foot sensorimotor tasks, employing common spatial pattern (CSP) and regularized common spatial pattern (RCSP). EEG from five healthy individuals (Dataset IVa, BCI Competition III) were evaluated by a cross-subject paradigm. Prediction performance was evaluated via a two-layer feed-forward neural network, where the classifier was trained and tested by data from two subjects independently. On average, the overall mean prediction accuracies obtained using all 118 channels are (55.98±6.53) and (71.20±5.32) in cases of CSP and RCSP, respectively, which are slightly lower than the accuracies obtained using only the selected channels, i.e., (58.95±6.90) and (71.41±6.65), respectively. The highest mean prediction accuracy achieved for a specific subject pair by using selected EEG channels was on average (90.36±5.59) and outperformed that achieved by using all available channels (86.07 ± 10.71). Spatially projected cortical sources approximated using wMEM may be useful for capturing inter-subject associative sensorimotor brain dynamics and pave the way toward an enhanced subject-independent BCI.
- 23 July 2019
- Published by Frontiers Media SA in Frontiers in Neuroinformatics
- Vol. 13, 47
Open AccessWavelet Entropy-Based Inter-subject Associative Cortical Source Localization for Sensorimotor BCI
We propose event-related cortical sources estimation from subject-independent electroencephalography (EEG) recordings for motor imagery brain computer interface (BCI). By using wavelet-based maximum entropy on the mean (wMEM), task-specific EEG channels are selected to predict right hand and right foot sensorimotor tasks, employing common spatial pattern (CSP) and regularized common spatial pattern (RCSP). EEG from five healthy individuals (Dataset IVa, BCI Competition III) were evaluated by a cross-subject paradigm. Prediction performance was evaluated via a two-layer feed-forward neural network, where the classifier was trained and tested by data from two subjects independently. On average, the overall mean prediction accuracies obtained using all 118 channels are (55.98±6.53) and (71.20±5.32) in cases of CSP and RCSP, respectively, which are slightly lower than the accuracies obtained using only the selected channels, i.e., (58.95±6.90) and (71.41±6.65), respectively. The highest mean prediction accuracy achieved for a specific subject pair by using selected EEG channels was on average (90.36±5.59) and outperformed that achieved by using all available channels (86.07 ± 10.71). Spatially projected cortical sources approximated using wMEM may be useful for capturing inter-subject associative sensorimotor brain dynamics and pave the way toward an enhanced subject-independent BCI.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2019, 4254-4257
Beamforming-inspired Spatial Filtering Technique for Intracardiac Electrograms
Bipolar electrograms (EGM) are widely used to assess intracardiac electrical activity and to find the atrial fibrillation-related sources. However, the interpretation of bipolar EGM is not straightforward. Variables including bipolar lead (vector) orientation relative to the wave propagation dynamics significantly impact the EGM and EGM-derived measures, which are clinically used to select target sources for catheter ablation. In this study, left atrial unipolar EGM were recorded using a 4 × 4 grid of 16 unipolar electrodes. A set (node) of 4 unipolar EGM were used to construct possible 6 bipolar EGM to evaluate the measurement uncertainty within a particular node. A novel beamforming-inspired spatial filtering (BiSF) method is proposed to reduce the potential measurement uncertainty inevitable in bipolar EGM. A set of three bipolar lead orientations that were constructed using a common unipolar electrode towards three different directions at 45°s, were added to form beamforming EGM. Finally, two beamforming EGM were intertwined to acquire BiSF EGM for a node. Results show greater signal power gain (at least around 10dB) for all BiSF EGM with better or similar signal-to-noise ratio as compared to their respective bipolar counterparts. In conclusion, reduced uncertainty in BiSF EGM improve the interpretation of EGM and EGM-derived measures used in clinical practice after further validation on a larger dataset.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2019, 4254-4257
Beamforming-inspired Spatial Filtering Technique for Intracardiac Electrograms
Bipolar electrograms (EGM) are widely used to assess intracardiac electrical activity and to find the atrial fibrillation-related sources. However, the interpretation of bipolar EGM is not straightforward. Variables including bipolar lead (vector) orientation relative to the wave propagation dynamics significantly impact the EGM and EGM-derived measures, which are clinically used to select target sources for catheter ablation. In this study, left atrial unipolar EGM were recorded using a 4 × 4 grid of 16 unipolar electrodes. A set (node) of 4 unipolar EGM were used to construct possible 6 bipolar EGM to evaluate the measurement uncertainty within a particular node. A novel beamforming-inspired spatial filtering (BiSF) method is proposed to reduce the potential measurement uncertainty inevitable in bipolar EGM. A set of three bipolar lead orientations that were constructed using a common unipolar electrode towards three different directions at 45°s, were added to form beamforming EGM. Finally, two beamforming EGM were intertwined to acquire BiSF EGM for a node. Results show greater signal power gain (at least around 10dB) for all BiSF EGM with better or similar signal-to-noise ratio as compared to their respective bipolar counterparts. In conclusion, reduced uncertainty in BiSF EGM improve the interpretation of EGM and EGM-derived measures used in clinical practice after further validation on a larger dataset.