GBGlenn Barest

Glenn Barest

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Glenn Barest has a total of 161 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Subretinal and Retrolaminar Migration of Intraocular Silicone Oil Detected on CT

    by M. Abdalkader, K. Takumi, M.N. Chapman, G.D. Barest, C. Peeler, O. Sakai

    BACKGROUND AND PURPOSE: Intraocular silicone oil injection has been used to treat complicated retinal detachments, and recently its retrolaminar and intracranial migration has been reported. The purpose of this study was to document the prevalence of posterior migration of intraocular silicone oil on head CT and describe the clinical and radiologic findings. MATERIALS AND METHODS: This retrospective study included 57 patients with intraocular silicone oil injection who underwent unenhanced head CT between November 2008 and July 2018. All images were visually evaluated for subretinal and retrolaminar migration of intraocular silicone oil involving the anterior visual pathway (optic nerve, optic chiasm, and optic tract) and the ventricular system. Attenuation values of those structures were measured and compared with those of the contralateral or adjacent normal structures. RESULTS: We detected subretinal and retrolaminar silicone oil migration in 7 of the 57 patients (12%), noting silicone oil at the optic nerve head (n = 2), retrolaminar optic nerve (n = 5), optic chiasm (n = 3), optic tract (n = 3), and in the lateral ventricles (n = 1). Attenuation values of the structures with silicone oil migration were significantly higher than those of the control regions (optic nerve head, 69.2 ± 12.4 vs 29.8 ± 10.2 HU, P < .001; retrolaminar optic nerve, 59.9 ± 11.6 vs 30.9 ± 8.6 HU, P < .001; optic chiasm, 74.2 ± 11.0 vs 25.6 ± 6.9 HU, P < .001; optic tract, 70.1 ± 4.7 vs 28.7 ± 7.2 HU, P < .001). No significant ophthalmic or neurologic complications were documented in the patients with silicone oil migration. CONCLUSIONS: Subretinal and retrolaminar migration of intraocular silicone oil is common. Although there were no apparent complications associated with silicone oil migration, the radiologist and clinician should be aware of this phenomenon.


  • Is bone density associated with intervertebral disc pressure in healthy and degenerated discs?

    by Paul M. Fein, Alexander DelMonaco, Timothy M. Jackman, Cameron Curtiss, Ali Guermazi, Glenn D. Barest, Elise F. Morgan


  • Open Access

    Spontaneous Resolution of Post-Traumatic Direct Carotid-Cavernous Fistula

    by Varun Naragum, Glenn Barest, Mohamad AbdalKader, Katharine M. Cronk, Thanh N. Nguyen

    Post-traumatic carotid-cavernous fistulas are due to a tear in the wall of the cavernous carotid artery, leading to shunting of blood into the cavernous sinus. These are generally high-flow fistula and rarely resolve spontaneously. Most cases require endovascular embolization. We report a case of Barrow type A carotid-cavernous fistula which resolved spontaneously.


  • Elastic Anisotropy of Trabecular Bone in the Elderly Human Vertebra

    by Ginu U. Unnikrishnan, John A. Gallagher, Amira I. Hussein, Glenn D. Barest, Elise F. Morgan

    Knowledge of the nature of the elastic symmetry of trabecular bone is fundamental to the study of bone adaptation and failure. Previous studies have classified human vertebral trabecular bone as orthotropic or transversely isotropic but have typically obtained samples from only selected regions of the centrum. In this study, the elastic symmetry of human vertebral trabecular bone was characterized using microfinite element (μFE) analyses performed on 1019 cubic regions of side length equal to 5 mm, obtained via thorough sampling of the centrums of 18 human L1 vertebrae (age = 81.17 ± 7.7 yr; eight males and ten females). An optimization procedure was used to find the closest orthotropic representation of the resulting stiffness tensor for each cube. The orthotropic elastic constants and orientation of the principal elastic axes were then recorded for each cube and were compared to the constants predicted from Cowin's fabric-based constitutive model (Cowin, 1985, “The Relationship Between the Elasticity Tensor and the Fabric Tensor,” Mech. Mater., 4(2), pp. 137–147.) and the orientation of the principal axes of the fabric tensor, respectively. Deviations from orthotropy were quantified by the “orthotropic error” (van Rietbergen et al., 1996, “Direct Mechanics Assessment of Elastic Symmetries and Properties of Trabecular Bone Architecture,” J. Biomech., 29(12), pp. 1653–1657), and deviations from transverse isotropy were determined by statistical comparison of the secondary and tertiary elastic moduli. The orthotropic error was greater than 50% for nearly half of the cubes, and the secondary and tertiary moduli differed from one another (p < 0.0001). Both the orthotropic error and the difference between secondary and tertiary moduli decreased with increasing bone volume fraction (BV/TV; p ≤ 0.007). Considering only the cubes with an orthotropic error less than 50%, only moderate correlations were observed between the fabric-based and the μFE-computed elastic moduli (R2 ≥ 0.337; p < 0.0001). These results indicate that when using a criterion of 5 mm for a representative volume element (RVE), transverse isotropy or orthotropy cannot be assumed for elderly human vertebral trabecular bone. Particularly at low values of BV/TV, this criterion does not ensure applicability of theories of continuous media. In light of the very sparse and inhomogeneous microstructure found in the specimens analyzed in this study, further work is needed to establish guidelines for selecting a RVE within the aged vertebral centrum.


  • Open Access

    Duplication of the Posterior Cerebral Artery and the ‘True Fetal' Variant

    by Hesham Masoud, Thanh N. Nguyen, Joshua Thatcher, Glenn Barest, Alexander M. Norbash

    We present a rare case of bilateral posterior cerebral artery variant anatomy seen in a patient presenting with acute ischemic stroke. An embryological explanation of the variant configuration is discussed along with demonstrative radiologic images and a display of the vascular territory supplied.


  • “Dazed and diffused”: making sense of diffusion abnormalities in neurologic pathologies

    by K M O'COnnor, G Barest, T Moritani, O Sakai, A Mian

    To review diffusion abnormalities seen in diffusion-weighted MRI in neurological pathologies. We examine the clinical significance of the abnormalities in a broad spectrum of neurological diseases and highlight our current understanding of their causes. Diffusion abnormalities seen on diffusion-weighted MRI can play an important role in the diagnosis and follow-up of a broad spectrum of neurological diseases. A thorough understanding of the appearance and significance of these abnormalities is critical in patient management.


  • Effect of Specimen-Specific Anisotropic Material Properties in Quantitative Computed Tomography-Based Finite Element Analysis of the Vertebra

    by Ginu U. Unnikrishnan, Glenn D. Barest, David B. Berry, Amira I. Hussein, Elise F. Morgan

    Intra- and inter-specimen variations in trabecular anisotropy are often ignored in quantitative computed tomography (QCT)-based finite element (FE) models of the vertebra. The material properties are typically estimated solely from local variations in bone mineral density (BMD), and a fixed representation of elastic anisotropy (“generic anisotropy”) is assumed. This study evaluated the effect of incorporating specimen-specific, trabecular anisotropy on QCT-based FE predictions of vertebral stiffness and deformation patterns. Orthotropic material properties estimated from microcomputed tomography data (“specimen-specific anisotropy”), were assigned to a large, columnar region of the L1 centrum (n = 12), and generic-anisotropic material properties were assigned to the remainder of the vertebral body. Results were compared to FE analyses in which generic-anisotropic properties were used throughout. FE analyses were also performed on only the columnar regions. For the columnar regions, the axial stiffnesses obtained from the two categories of material properties were uncorrelated with each other (p = 0.604), and the distributions of minimum principal strain were distinctly different (p ≤ 0.022). In contrast, for the whole vertebral bodies in both axial and flexural loading, the stiffnesses obtained using the two categories of material properties were highly correlated (R2 > 0.82, p < 0.001) with, and were no different (p > 0.359) from, each other. Only moderate variations in strain distributions were observed between the two categories of material properties. The contrasting results for the columns versus vertebrae indicate a large contribution of the peripheral regions of the vertebral body to the mechanical behavior of this bone. In companion analyses on the effect of the degree of anisotropy (DA), the axial stiffnesses of the trabecular column (p < 0.001) and vertebra (p = 0.007) increased with increasing DA. These findings demonstrate the need for accurate modeling of the peripheral regions of the vertebral body in analyses of the mechanical behavior of the vertebra.


  • The intravertebral distribution of bone density: correspondence to intervertebral disc health and implications for vertebral strength

    by A. I. Hussein, T. M. Jackman, S. R. Morgan, G. D. Barest, E. F. Morgan

    Summary This study's goal was to determine associations among the intravertebral heterogeneity in bone density, bone strength, and intervertebral disc (IVD) health. Results indicated that predictions of vertebral strength can benefit from considering the magnitude of the density heterogeneity and the congruence between the spatial distribution of density and IVD health. Introduction This study aims to determine associations among the intravertebral heterogeneity in bone density, bone strength, and IVD health Methods Regional measurements of bone density were performed throughout 30 L1 vertebral bodies using micro-computed tomography (μCT) and quantitative computed tomography (QCT). The magnitude of the intravertebral heterogeneity in density was defined as the interquartile range and quartile coefficient of variation in regional densities. The spatial distribution of density was quantified using ratios of regional densities representing different anatomical zones (e.g., anterior to posterior regional densities). Cluster analysis was used to identify groups of vertebrae with similar spatial distributions of density. Vertebral strength was measured in compression. IVD health was assessed using two scoring systems. Results QCT- and μCT-based measures of the magnitude of the intravertebral heterogeneity in density were strongly correlated with each other (p < 0.005). Accounting for the interquartile range in regional densities improved predictions of vertebral strength as compared to predictions based only on mean density (R 2 = 0.59 vs. 0.43; F-test p-value = 0.018). Specifically, after adjustment for mean density, vertebral bodies with greater heterogeneity in density exhibited higher strength. No single spatial distribution of density was associated with high vertebral strength. Analyses of IVD scores suggested that the health of the adjacent IVDs may modulate the effect of a particular spatial distribution of density on vertebral strength. Conclusions Noninvasive measurements of the intravertebral distribution of bone density, in conjunction with assessments of IVD health, can aid in predictions of bone strength and in elucidating biomechanical mechanisms of vertebral fracture.


  • Influence of Specimen-Specific Trabecular Anisotropy on QCT-Based Finite Element Analyses of Lumbar Vertebra

    by Ginu U. Unnikrishnan, Glenn D. Barest, David B. Berry, Amira I. Hussein, Elise F. Morgan

    Quantitative computed tomography (QCT)-based finite element (FE) models provide better predictions of vertebral strength compared to traditional methods currently used in clinical diagnosis [1]. In QCT-based FE models, the intra- and inter-specimen variations in trabecular anisotropy are often ignored, despite evidence that the biomechanical behavior of the vertebra depends on the architecture of the vertebral trabecular bone [2]. A realistic representation of the specimen-specific, trabecular anisotropy in the FE models of vertebrae would potentially improve predictions of vertebral failure. The overall goal of this study was to evaluate the importance of incorporating specimen-specific, trabecular anisotropy for QCT-based FE predictions of vertebral stiffness and deformation patterns. The major aims of this study were (a) to compare the QCT-based FE results obtained with a constant, anisotropic, material model (the “generic-anisotropic” model) for trabecular bone to those obtained with a specimen-specific, anisotropic, material model and (b) to study the influence of degree of anisotropy (DA) on the FE predictions of vertebral stiffness.

  • Asymmetric Posterior Reversible Encephalopathy Syndrome Complicating Hemodynamic Augmentation for Subarachnoid Hemorrhage-Associated Cerebral Vasospasm

    by Barbara Voetsch, Nicholas Tarlov, Thanh N. Nguyen, Christina DeFusco, Glenn D. Barest, Alexander Norbash, Deborah M. Green, Joseph D. Burns

    Posterior reversible encephalopathy syndrome (PRES) is a rare complication of hemodynamic augmentation for subarachnoid hemorrhage (SAH)-associated vasospasm. The roles of hyperperfusion and hypoperfusion in the genesis of PRES remain uncertain.