Jeffrey H. Warner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jeffrey H. Warner has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
- Ani Khachatrian
U.S. Naval Research Laboratory, Washington, DC, USA
14 shared publications - Stephen P. Buchner
U.S. Naval Research Laboratory, Washington, DC, USA
11 shared publications Dale McMorrow
U.S. Naval Research Laboratory (NRL), Washington, DC 20052 USA
10 shared publications- Zachary E. Fleetwood
School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332-0250 USA
9 shared publications - Adrian Ildefonso
U.S. Naval Research Laboratory, Washington, DC, USA
7 shared publications John D. Cressler
6 shared publications
Latest Publications
- 21 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (7) , 1521-1529
Tradeoffs Between RF Performance and SET Robustness in Low-Noise Amplifiers in a Complementary SiGe BiCMOS Platform
Low-Noise amplifiers (LNAs) are necessary components for any communications system. Single-event transients (SET) induced by energetic particles in space can corrupt the data in an RF receiver. Using pnp SiGe HBTs, instead of their more common npn counterparts, has been shown to be an effective mitigation technique in digital, analog and RF circuits. Since pnp SiGe HBTs tend to have lower performance than npn SiGe HBTs, the tradeoffs between performance and SET robustness have been evaluated in the present work through the use of simulations. Two LNAs were designed using an algorithmic design technique, one using only npn SiGe HBTs, and the other only pnp devices. The npn LNA had higher peak gain and lower noise figure at the center frequency of 5 GHz when compared to the pnp LNA, by 3.2 dB and 0.4 dB, respectively. However, the npn LNA also produced transients with amplitudes twice as large as the pnp LNA across all simulated linear energy transfers. Although the pnp LNA has lower overall performance, it is also more robust to SETs. Thus, the choice between using npn and pnp SiGe HBTs for an RF design will depend on application requirements.
- 21 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (7) , 1521-1529
Tradeoffs Between RF Performance and SET Robustness in Low-Noise Amplifiers in a Complementary SiGe BiCMOS Platform
Low-Noise amplifiers (LNAs) are necessary components for any communications system. Single-event transients (SET) induced by energetic particles in space can corrupt the data in an RF receiver. Using pnp SiGe HBTs, instead of their more common npn counterparts, has been shown to be an effective mitigation technique in digital, analog and RF circuits. Since pnp SiGe HBTs tend to have lower performance than npn SiGe HBTs, the tradeoffs between performance and SET robustness have been evaluated in the present work through the use of simulations. Two LNAs were designed using an algorithmic design technique, one using only npn SiGe HBTs, and the other only pnp devices. The npn LNA had higher peak gain and lower noise figure at the center frequency of 5 GHz when compared to the pnp LNA, by 3.2 dB and 0.4 dB, respectively. However, the npn LNA also produced transients with amplitudes twice as large as the pnp LNA across all simulated linear energy transfers. Although the pnp LNA has lower overall performance, it is also more robust to SETs. Thus, the choice between using npn and pnp SiGe HBTs for an RF design will depend on application requirements.
- 31 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (1) , 71-80
Comparison of Single-Event Transients in SiGe HBTs on Bulk and Thick-Film SOI
A comparison of heavy-ion-induced single-event transients (SETs) in silicon-germanium heterojunction bipolar transistors (SiGe HBTs) fabricated on both bulk and silicon-on-insulator (SOI) substrates is presented. Experimental heavy-ion data show a reduction of sensitive volume of $\approx 350\times $ for the SiGe HBTs fabricated on SOI compared to those on a bulk substrate. Furthermore, the results indicate that the sensitive volume of the SOI SiGe HBTs is confined to the intrinsic device. These results have been confirmed using pulsed laser data and TCAD simulations. Limiting the charge collection depth of SiGe HBTs by fabricating them on SOI facilitates correlation of ion and laser results. The improved ease of correlation is a result of suppressing diffusive charge collection mechanisms that are difficult to replicate with the charge deposition profile generated by two-photon absorption using a tightly focused laser beam. However, a potential issue with pulsed laser testing is determining the loss of the pulse energy through the buried oxide, which requires detailed knowledge of the semiconductor platform. Overall, the reduction of sensitive volume for the SOI SiGe HBTs compared to those on a bulk substrate is a clear advantage from a single-event upset vulnerability perspective.- 31 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (1) , 71-80
Comparison of Single-Event Transients in SiGe HBTs on Bulk and Thick-Film SOI
A comparison of heavy-ion-induced single-event transients (SETs) in silicon-germanium heterojunction bipolar transistors (SiGe HBTs) fabricated on both bulk and silicon-on-insulator (SOI) substrates is presented. Experimental heavy-ion data show a reduction of sensitive volume of $\approx 350\times $ for the SiGe HBTs fabricated on SOI compared to those on a bulk substrate. Furthermore, the results indicate that the sensitive volume of the SOI SiGe HBTs is confined to the intrinsic device. These results have been confirmed using pulsed laser data and TCAD simulations. Limiting the charge collection depth of SiGe HBTs by fabricating them on SOI facilitates correlation of ion and laser results. The improved ease of correlation is a result of suppressing diffusive charge collection mechanisms that are difficult to replicate with the charge deposition profile generated by two-photon absorption using a tightly focused laser beam. However, a potential issue with pulsed laser testing is determining the loss of the pulse energy through the buried oxide, which requires detailed knowledge of the semiconductor platform. Overall, the reduction of sensitive volume for the SOI SiGe HBTs compared to those on a bulk substrate is a clear advantage from a single-event upset vulnerability perspective.- 7 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 66 (1) , 290-298
A Low-Power, Real-Time Displacement Damage Dosimeter
The Naval Research Laboratory has developed a low-power, real-time displacement damage dosimeter. RT3D consists of two components; one being the measurement electronics, and the second being the actual dosimeter (GaAs diode) exposed to the radiation source. RT3D accumulates displacement damage passively (without power) and the displacement damage dose (DDD) is measured at will with measurement electronics by measuring the GaAs diode dark current at one or more forward bias voltages. The displacement damage dose is subsequently determined in real-time from a calibration curve derived from ground based testing. The dosimeter is capable of measuring approximately 3 orders of magnitude in DDD. The dosage measurement range of the sensor can be modified by placing an absorber material over the sensor. Proton testing performed in situ yielded an error estimate determination to within 10% for simulated space use.
- 7 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 66 (1) , 290-298
A Low-Power, Real-Time Displacement Damage Dosimeter
The Naval Research Laboratory has developed a low-power, real-time displacement damage dosimeter. RT3D consists of two components; one being the measurement electronics, and the second being the actual dosimeter (GaAs diode) exposed to the radiation source. RT3D accumulates displacement damage passively (without power) and the displacement damage dose (DDD) is measured at will with measurement electronics by measuring the GaAs diode dark current at one or more forward bias voltages. The displacement damage dose is subsequently determined in real-time from a calibration curve derived from ground based testing. The dosimeter is capable of measuring approximately 3 orders of magnitude in DDD. The dosage measurement range of the sensor can be modified by placing an absorber material over the sensor. Proton testing performed in situ yielded an error estimate determination to within 10% for simulated space use.
- 13 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 66 (1) , 389-396
The Effects of Temperature on the Single-Event Transient Response of a High-Voltage (>30 V) Complementary SiGe-on-SOI Technology
- 13 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 66 (1) , 389-396
The Effects of Temperature on the Single-Event Transient Response of a High-Voltage (>30 V) Complementary SiGe-on-SOI Technology
- 29 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 66 (1) , 240-247
Best Practices for Using Electrostatic Discharge Protection Techniques for Single-Event Transient Mitigation
We provide “best practices” for single-event transient (SET) mitigation using electrostatic discharge (ESD) protection techniques. We investigate the correlation between SET suppression and RF performance when ESD protection circuits for SET mitigation are combined with various RF switches. The three different single-pole single-throw (SPST) switch configurations (conventional design, floating body, and floating body/n-well) were implemented to provide insight on how to best apply dc ESD protection techniques for also achieving robust SET mitigation. Based on two-photon absorption laser experiments and RF measurements, a conventional SPST switch configuration shows relatively poor RF performance but is effective for SET mitigation due to the SET discharge current path provided by ESD protection circuit. On the other hand, the combination of the SPST switch and the ESD circuit, which exhibits the best RF performance among the three configurations, is relatively vulnerable to SETs. Based on these results, strategies and methodologies for ESD protection techniques to effectively mitigate SET are proposed.
- 29 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 66 (1) , 240-247
Best Practices for Using Electrostatic Discharge Protection Techniques for Single-Event Transient Mitigation
We provide “best practices” for single-event transient (SET) mitigation using electrostatic discharge (ESD) protection techniques. We investigate the correlation between SET suppression and RF performance when ESD protection circuits for SET mitigation are combined with various RF switches. The three different single-pole single-throw (SPST) switch configurations (conventional design, floating body, and floating body/n-well) were implemented to provide insight on how to best apply dc ESD protection techniques for also achieving robust SET mitigation. Based on two-photon absorption laser experiments and RF measurements, a conventional SPST switch configuration shows relatively poor RF performance but is effective for SET mitigation due to the SET discharge current path provided by ESD protection circuit. On the other hand, the combination of the SPST switch and the ESD circuit, which exhibits the best RF performance among the three configurations, is relatively vulnerable to SETs. Based on these results, strategies and methodologies for ESD protection techniques to effectively mitigate SET are proposed.
- 22 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 66 (1) , 359-367
Optimizing Optical Parameters to Facilitate Correlation of Laser- and Heavy-Ion-Induced Single-Event Transients in SiGe HBTs
- 22 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 66 (1) , 359-367
Optimizing Optical Parameters to Facilitate Correlation of Laser- and Heavy-Ion-Induced Single-Event Transients in SiGe HBTs
- 13 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (1) , 369-375
Correlation of the Spatial Variation of Single-Event Transient Sensitivity With Thermoreflectance Thermography in ${\text {Al}}_{x} {\text {Ga}}_{1-x}$ N/GaN HEMTsSpatial variations of single-event transient (SET) sensitivity in Al 0.25 Ga 0.75 N/GaN HEMTs are revealed using focused, pulsed UV laser light. SETs in regions of enhanced sensitivity have larger amplitudes and are termed “hot spots.” They are the same regions where large temperature changes are observed with thermoreflectance thermography. Both effects are attributed to the presence of material defects: SETs with enhanced amplitudes have reduced decay times due to thermally assisted detrapping; increased temperature is due to carrier scattering by the same defects.
- 13 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (1) , 369-375
Correlation of the Spatial Variation of Single-Event Transient Sensitivity With Thermoreflectance Thermography in ${\text {Al}}_{x} {\text {Ga}}_{1-x}$ N/GaN HEMTsSpatial variations of single-event transient (SET) sensitivity in Al 0.25 Ga 0.75 N/GaN HEMTs are revealed using focused, pulsed UV laser light. SETs in regions of enhanced sensitivity have larger amplitudes and are termed “hot spots.” They are the same regions where large temperature changes are observed with thermoreflectance thermography. Both effects are attributed to the presence of material defects: SETs with enhanced amplitudes have reduced decay times due to thermally assisted detrapping; increased temperature is due to carrier scattering by the same defects.
- 11 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (1) , 399-406
SiGe HBT Profiles With Enhanced Inverse-Mode Operation and Their Impact on Single-Event Transients
The doping profile of silicon-germanium heterojunction bipolar transistors (SiGe HBTs) are modified to enhance inverse-mode (IM) device operation. Device improvements are presented in this work, along with the impact the alterations have on the radiation effects response. This investigation represents the first published occurrence of a radiation-hardening-by-process (RHBP) approach in a SiGe HBT technology. Results show that improving IM performance can degrade the radiation tolerance of the structure. Total ionizing dose and single-event transient results are provided along with an analysis that utilizes TCAD simulation. An additional profile modification using an implanted vertical superjunction is included in this work to expand upon how non-radiation specific device modifications can impact singleevent transients.
- 11 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (1) , 399-406
SiGe HBT Profiles With Enhanced Inverse-Mode Operation and Their Impact on Single-Event Transients
The doping profile of silicon-germanium heterojunction bipolar transistors (SiGe HBTs) are modified to enhance inverse-mode (IM) device operation. Device improvements are presented in this work, along with the impact the alterations have on the radiation effects response. This investigation represents the first published occurrence of a radiation-hardening-by-process (RHBP) approach in a SiGe HBT technology. Results show that improving IM performance can degrade the radiation tolerance of the structure. Total ionizing dose and single-event transient results are provided along with an analysis that utilizes TCAD simulation. An additional profile modification using an implanted vertical superjunction is included in this work to expand upon how non-radiation specific device modifications can impact singleevent transients.
- Open Access
- 13 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (1) , 239-248
Utilizing SiGe HBT Power Detectors for Sensing Single-Event Transients in RF Circuits
This paper demonstrates the use of an RF power detector to sense the occurrence of single-event transients (SETs) in RF circuits and systems. The detector was connected to a low-noise amplifier (LNA), and the relationship between the detector output and the LNA transients was investigated via two-photon absorption, pulsed-laser testing, together with mixed-mode TCAD simulations. The response of the detector shows a strong correlation with the RF power of the generated SET. An analytical expression for the detector output is derived and utilized to fit the data. The effects of parameters affecting circuit performance on the detector response to SETs are explored using calibrated TCAD mixed-mode simulations, and design tradeoffs are presented. Finally, a solution to distinguish between transients generated in the detector from those generated in the circuit being monitored is proposed and verified in simulation. The use of detectors to monitor SETs in RF systems could lead to judicious deployment of detection-driven SET mitigation techniques.
- 13 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (1) , 239-248
Open AccessUtilizing SiGe HBT Power Detectors for Sensing Single-Event Transients in RF Circuits
This paper demonstrates the use of an RF power detector to sense the occurrence of single-event transients (SETs) in RF circuits and systems. The detector was connected to a low-noise amplifier (LNA), and the relationship between the detector output and the LNA transients was investigated via two-photon absorption, pulsed-laser testing, together with mixed-mode TCAD simulations. The response of the detector shows a strong correlation with the RF power of the generated SET. An analytical expression for the detector output is derived and utilized to fit the data. The effects of parameters affecting circuit performance on the detector response to SETs are explored using calibrated TCAD mixed-mode simulations, and design tradeoffs are presented. Finally, a solution to distinguish between transients generated in the detector from those generated in the circuit being monitored is proposed and verified in simulation. The use of detectors to monitor SETs in RF systems could lead to judicious deployment of detection-driven SET mitigation techniques.
- 24 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 64 (5) , 1133-1136
Strong Correlation Between Experiment and Simulation for Two-Photon Absorption Induced Carrier Generation
This correspondence comments on the correlation between measured and simulated charge collection in two diode structures presented in [1]. In [1], results from pulsed-laser-induced charge deposition via two-photon absorption revealed reasonable correlation between experimental data and simulations in some aspects but showed lack of correlation in terms of the measured and predicted magnitudes of the collected charge. The source of this poor agreement has recently been determined, and is attributed to an incorrect pulse energy calibration used for those experiments. With the proper energy calibration applied, the agreement between simulation and experiment is nearly quantitative for all observables in both devices. These results significantly strengthen the validity of the nonlinear optical beam propagation method numerical approach for accurately predicting pulsed-laser-induced charge deposition.
- 24 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 64 (5) , 1133-1136
Strong Correlation Between Experiment and Simulation for Two-Photon Absorption Induced Carrier Generation
This correspondence comments on the correlation between measured and simulated charge collection in two diode structures presented in [1]. In [1], results from pulsed-laser-induced charge deposition via two-photon absorption revealed reasonable correlation between experimental data and simulations in some aspects but showed lack of correlation in terms of the measured and predicted magnitudes of the collected charge. The source of this poor agreement has recently been determined, and is attributed to an incorrect pulse energy calibration used for those experiments. With the proper energy calibration applied, the agreement between simulation and experiment is nearly quantitative for all observables in both devices. These results significantly strengthen the validity of the nonlinear optical beam propagation method numerical approach for accurately predicting pulsed-laser-induced charge deposition.