ABAngelo Balestrazzi

Angelo Balestrazzi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Angelo Balestrazzi has a total of 59 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Tectonic Keratoplasty to Restore the Bulbar Wall after Block Excision of Benign and Malignant Intraocular Tumors

    by Emilio Balestrazzi, Luigi Mosca, Maria Antonietta Blasi, Maria Ilaria Giannico, Angelo Balestrazzi

    Purpose. To report the surgical treatment and follow-up of tumors of the anterior uvea and epithelial cysts of the anterior chamber in 4 patients submitted to block excision and tectonic corneal graft between 2008 and 2012. Methods. This is a retrospective, nonrandomized case series. Two patients were affected by anterior uveal malignant melanoma, and 2 patients were referred to us for large epithelial iris cysts with anterior chamber angle involvement and partial corneal failure. A simultaneous block removal of the lesion and adjacent iris, cornea (when necessary), ciliary body, and sclera was performed; the resulting defect was covered by a tectonic whole thickness corneal graft. Follow-up ranged from 2 to 7 years (mean time: 5 ± 1.6 MD). Results. Local control of malignant melanoma was observed during the follow-up, but cataract surgery was planned in both patients and pars plana vitrectomy for vitreous hemorrhage occurred in one case. No recurrence of cysts was detected. After iris cysts excision, a planned second-time surgery was necessary in one patient: optical penetrating keratoplasty, centered on the visual axis, implantation of one refractive IOL (intraocular lens) in the bag, and one cosmetic IOL in the sulcus, to restore the iris diaphragm. Conclusions. Block excision followed by the tectonic corneal graft seems to be the treatment of choice for selected cases of epithelial cysts of the anterior chamber and anterior uvea melanomas with epibulbar extension. Further surgery, as a second step, could be required to improve functional results of this challenging technique.


  • Open Access

    Diagnosis, Clinical Trend, and Treatment of Diffuse Lamellar Keratitis after Femtosecond Laser-Assisted in situ Keratomileusis: A Case Report

    by Angelo Balestrazzi, Alessandra Balestrazzi, Maria Ilaria Giannico, Paolo Michieletto, Emilio Balestrazzi

    We report a severe case of diffuse lamellar keratitis (DLK) following femtosecond laser-assisted in situ keratomileusis (femto-LASIK). A 25-year-old man was submitted to 150 kHz iFS® IntraLase-assisted LASIK in both eyes for compound myopic astigmatism. The day after surgery, clinical examination showed a diffuse whitish granular cell reaction particularly in the right eye. High-dose dexamethasone eyedrops with topical antibiotic and artificial tears were prescribed. Five days after surgery, a central corneal opacity with convergent striae was detected at biomicroscopy. The suspicion of DLK was confirmed. Additional therapy based on hyperosmolar ophthalmological solution, oral doxycycline, and topical 10% sodium citrate was prescribed. Treatment was continued and tapered for over 3 months. Improvement in corneal transparency were obtained 2 weeks after the systemic therapy had been started. Uncorrected visual acuity improved from 20/32 to 20/20 at 1-year follow-up. DLK represents an infrequent complication after femto-LASIK. It should resolve without sequelae if promptly diagnosed and treated, without necessity of corneal flap lifting.


  • Femtosecond laser-assisted in situ keratomileusis for the correction of residual ametropia after deep anterior lamellar keratoplasty: a pilot investigation

    by A Balestrazzi, F Menicacci, G Cartocci, P Michieletto, E Balestrazzi

    PurposeTo evaluate the refractive and visual results of one-stage laser-assisted in situ keratomileusis with femtosecond laser (Femto-LASIK) for the correction of residual ametropia after deep anterior lamellar keratoplasty (DALK).MethodsThis retrospective study included 13 eyes of 12 patients, who underwent corneal Femto-LASIK to correct refractive errors after DALK. IntraLase FS150 was used to create a lamellar flap and excimer laser ablation for refractive correction was performed using the Star S4 IR Excimer Laser in eight cases and the Technolas 217z Excimer Laser in Tissue Saving mode in five cases. Perioperative variables of interest included uncorrected (UDVA) and corrected (CDVA) distance visual acuities, manifest refraction and corneal topography.ResultsThe mean spherical equivalent preoperatively was -4.85±2.82 (range, -9.5 to 0 D). At the last visit the mean postoperative spherical equivalent (SE) was -0.44±0.67 D (P<0.05). The mean postoperative UDVA was 0.12±0.12 logMAR. There was a statistically significant increase in CDVA 6 months after Femto-LASIK (P<0.05). Intraoperative and postoperative complications did not develop in this series of eyes.ConclusionsCorrecting the preoperative manifest refractive error with Femto-LASIK led to a significant improvement in the UDVA and CDVA without surgical complications.


  • Open Access

    Mini-incision cataract surgery and toric lens implantation for the reduction of high myopic astigmatism in patients with pellucid marginal degeneration

    by A Balestrazzi, S Baiocchi, G Cartocci, G M Tosi, G Martone, P Michieletto

    To evaluate the clinical outcomes, safety, and efficacy of cataract surgery with the implantation of a toric intraocular lens (IOL) in eyes with stable pellucid marginal degeneration (PMD). Eleven eyes (eight patients) diagnosed as stable PMD and cataract underwent mini-incision 2.2 mm cataract surgery followed by the implantation of hydrophobic toric aspheric IOL (AcrySof IQ Toric IOL, Alcon, Fort Worth, TX, USA). Perioperative variables of interest included uncorrected (UDVA) and corrected (CDVA) distance visual acuities, manifest refraction, and corneal topography. Paired samples t-tests were used to analyze preoperative and postoperative visual acuity, astigmatism, and spherical equivalent (SE) parameters. Follow-up was 6 months. The mean CDVA was 0.62±0.26 logMAR preoperatively and 0.07±0.07 logMAR postoperatively. The mean preoperative sphere and cylinder was -3.14±3.58D and -4.84±2.02D, respectively. The mean postoperative manifest refractive sphere and cylinder was -0.30±0.51D and -0.81±1.51D, respectively. There was a significant reduction in refractive astigmatism after toric IOL implantation (P<0.002). The toric IOL axis rotation was <5° in all cases at the final follow-up. Implantation of hydrophobic toric IOL was a safe and effective surgical procedure to correct mild to moderate stable PMD.


  • Improving Boston Type 1 Keratoprosthesis Procedure: One-Touch Femtosecond-Assisted Preparation and Centration of Donor Carrier Tissue

    by Alex Malandrini, Angelo Balestrazzi, Annalisa Canovetti, Francesca Rossi, Letizia Cortesini, Chiara Lenzetti, Roberto Pini, Luca Menabuoni

    Purpose: We describe a technique to avoid decentration of the visual axis of the Boston type 1 keratoprosthesis (Kpro), performing 2 concentric trephinations with femtosecond laser. Methods: Two concentric side cuts were performed in a donor cornea using the 150-kHz Intralase™ FS laser. Within the same applanation procedure, an 8.5-mm-diameter anterior side cut was performed, followed by a concentric 3-mm-diameter anterior side cut. Results: The technique was successfully replicated in 7 cases. Conclusions: Femtosecond laser-assisted double trephination results in a correctly prepared donor cornea, and in an inner side precisely matched with the prosthesis. At the end of the surgery, the Kpro was correctly centered.

  • Phacoemulsificator and Sterile Drapes Contamination during Cataract Surgery: A Microbiological Study

    by Angelo Balestrazzi, Alex Malandrini, Francesca Montagnani, Ghislaine Laure Nguisseu Chegoua, Leonardo Ciompi, Alessandra Zanchi, Gian Marco Tosi, Gian Luca Martone, Ilaria Motolese, Mario Fruschelli

    Purpose: To determine the microbial contamination of the irrigating fluids at the time of phacoemulsification after the use of topical povidone-iodine and antibiotics prophylaxis. Methods: A total of 119 patients undergoing cataract surgery were enrolled in this prospective study. All patients received 5 mg/mL levofloxacin starting from the day prior to surgery and topical and 5% povidone-iodine drops starting from 30 minutes before the surgery. At the end of each surgery, 2 samples of drainage liquids were sterilely collected from the drainage bags (DBL) and from the peristaltic pump single-cassettes (PCL) of the phacoemulsification machine. Search for aerobic and anaerobic bacteria and fungi was performed. Results: Seventy-five patients (31.5%) revealed a growth of at least one microbial species (53 DBL and 22 PCL, 44.5% vs 18.5%; p<0.001). Sixty-six patients (55.5%) had at least one positive intraoperative solution. Overall, 111 microbial strains were collected: 82 (74%) Gram-positive bacteria, 20 (18%) fungi, and 9 (8%) Gram-negative bacteria. Thirteen staphylococcal isolates from PCL, compared with 52 out of DBL (11% vs 43.7%, p<0.001), fungi were essentially isolated from PCL. No significant correlation was found between microbial isolation and risk factors. No postsurgical infective complication occurred in the follow-up. Conclusions: Evaluation of intraoperative fluids can provide evidence on sources or vehicles of postsurgical infections. Antibiotic prophylaxis and topical povidone-iodine can significantly contribute to minimize the risk of endophthalmitis.


  • In Vivo Confocal Microscopy and Anterior Segment Optical Coherence Tomography in a Case of Alternaria Keratitis

    by Gianluca Martone, Patrizia Pichierri, Rossella Franceschini, Antonio Moramarco, Leonardo Ciompi, Gian Marco Tosi, Angelo Balestrazzi

    PURPOSE: To report a case of Alternaria alternata keratitis analyzed with in vivo confocal microscopy (IVCM) and anterior segment optical coherence tomography (OCT). METHODS: A 68-year-old man with unilateral keratitis was evaluated using IVCM (Heidelberg Retina Tomograph II; Heidelberg, Germany) and anterior segment OCT (Visante OCT; Carl Zeiss Meditec, Dublin, CA). RESULTS: IVCM demonstrated the presence of small, round, hyperreflective cells surrounded by hyporeflective irregular areas and highly reflective dendritic shaped cells at the level of the epithelium. Stromal examination revealed many hypereflective filamentous structures, and some hyporeflective perpendicular lines and hyperreflective oval bodies were clearly visible along the filaments. Anterior segment OCT examination demonstrated a thickened cornea due to diffuse edema and an irregular corneal surface corresponding to the ulcer. There were hyperreflective areas beneath the epithelium representing the infiltrate. Microbiological examination of corneal scrapings demonstrated the presence of Alternaria alternata. After 1 month of antifungal treatment, IVCM demonstrated a significant reduction of the inflammatory cells and a hyperreflective scar-like tissue. Branching hyphal infiltrates were no longer present. OCT also documented the healing process and the complete recovery of the central and peripheral stromal thickness. CONCLUSIONS: IVCM and anterior segment OCT could be useful for the early diagnosis and treatment of fungal keratitis


  • Spontaneous in-the-Bag Intraocular Lens Luxation into the Vitreous Cavity: Last-Stage Complication of Pseudoexfoliative Syndrome after Phacoemulsification

    by A. Balestrazzi, G.M. Tosi, M. Alegente, C. Mazzotta, P.L. Esposti, E. Berni, P. Michieletto, T. Caporossi

    Purpose: We describe 8 cases of late spontaneous in-the-bag intraocular lens (IOL) luxation into the vitreous cavity, which occurred at the Department of Ophthalmology and Neurosurgery of the University of Siena between January and December 2006. Methods: In this interventional case series, the medical records of all patients with posterior luxation of in-the-bag IOLs – who had undergone a pars plana vitrectomy with IOL removal and scleral fixation IOL implantation between January and December 2007 at the Department of Ophthalmology and Neurosurgery of Siena, Italy – were retrospectively reviewed. Results: The final post- operative visual acuity was 20/30 or better in 6 patients, while myopic macular degeneration and total retinal detachment limited visual acuity in the remaining 2 patients. Conclusion: The high prevalence of pseudoexfoliation (PEX) in the patients who had been operated for cataract phacoemulsification in our department could explain the occurrence of 8 posterior luxations of in-the-bag IOLs in only 1 year. Our study suggests that for the next years we will expect an increase in occurrence of spontaneous in-the- bag IOL luxations in the vitreous cavity. This condition could represent the last stage of PEX syndrome.


  • Optical Aberrations in Pseudophakic Eyes After 2.5-mm Nd:YAG Laser Capsulotomy for Posterior Capsule Opacification

    by Fabrizio Casprini, Angelo Balestrazzi, Gian Marco Tosi, Marco Lazzarotto, Alex Malandrini, Francesca Lepri, Gianluca Martone, Tomaso Caporossi, Aldo Caporossi

    Purpose: To evaluate aberrometric outcomes in eyes with posterior capsule opacification after 2.5-mm Nd: YAG laser capsulotomy compared to pseudophakic eyes without posterior capsule opacification. Methods: Photographic image analysis of posterior capsule opacification was performed on 36 eyes that showed advanced posterior capsule opacification (case group) and on 36 eyes which showed absence of posterior capsule opacification (control group). Best spectacle-corrected visual acuity (BSCVA) and wavefront analysis were performed in the control group and in the case group after 2.5-mm capsulotomy. Results: Mean BSCVA in the case group after treatment was significantly higher than before treatment ( P <.05) and similar to the BSCVA in the control group ( P >.1). Aberrometric analysis was performed on the control group, but light scattering prevented the analysis in posterior capsule opacification before capsulotomy, which was then performed after the intervention in 18 (50%) eyes. Mean total high order aberrations and 3rd order aberrations were significantly higher in the case group than in the control group ( P <.05). Fourth and 5th order aberration values were similar between the case and control groups ( P >.06). Conclusions: Our wavefront results can detect a deterioration of visual quality in patients that underwent a 2.5-mm Nd:YAG capsulotomy compared to pseudophakic patients not affected by posterior capsule opacification. This difference cannot be detected by standard visual acuity examination. Further study is needed to clarify whether our high order aberration findings were related to small, 2.5-mm capsulotomies and whether aberrometry may be indicative for mild to moderate posterior capsule opacification. [ J Refract Surg. 2008;24:702–706.]


  • A randomized prospective study comparing trabeculectomy with and without the use of a new removable suture

    by A. Caporossi, A. Balestrazzi, A. Malandrini, G. M. Tosi, T. Caporossi, P. Frezzotti, Luca Lomurno

    Introduction The aim of this prospective study is to verify, in terms of both early postoperative complications and intraocular pressure (IOP) outcomes, the performance of a scleral flap removable suture. Materials and Methods Sixty-six patients that underwent trabeculectomy were randomly divided into two groups: in the first group (group A, 33 eyes) a standard fornix-based trabeculectomy was performed by using a conjunctival chain suture. In the second group (group B, 33 eyes) the same technique was performed with the additional employment of a new removable suture to the scleral flap. The patients were followed-up for 12 months. Results After 1 year the mean IOP was 16.58 mmHg (±3.73 mmHg) in group A, and 16.12 mmHg (±4.21 mmHg) in group B; statistical analysis did not show significant differences between the two groups (P = 0.19). Early postoperative hypotony and shallowing of the anterior chamber were significantly more frequent after standard trabeculectomy than after trabeculectomy using the removable suture (P < 0.02). Conclusions The employment of a fornix-based conjunctival chain suture for the flap allows the use of the removable scleral flap suture, which has proved very effective in preventing insufficient flap resistance with aqueous overdrainage and hypotony, and which is also easy to apply and to remove. Compared with standard trabeculectomy, this device has proved to have similar IOP-lowering efficacy, together with a lower rate of early postoperative complications.