Leticia López-Martínez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Leticia López-Martínez has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
- Nancy Ornelas-Soto
Laboratorio de Nanotecnología Ambiental, Escuela de Ingeniería y Ciencias, Tecnológico de Monterrey, Monterrey 64849, Mexico
7 shared publications - Judith Amador-Hernández
Universidad Autónoma de Coahuila
6 shared publications Pedro Luis López-De-Alba
Instituto de Investigaciones Cientı́ficas, Universidad de Guanajuato, Cerro de la Venada s/n, L. de Retana No. 5, Guanajuato 36000, Gto., Mexico
6 shared publications- Jorge Luis Guzmán-Mar
Facultad de Ciencias Químicas, Universidad Autónoma de Nuevo León (UANL), Ave. Universidad s/n, Cd. Universitaria, San Nicolás de los Garza 66455, Nuevo León, Mexico
5 shared publications Kazimierz Wróbel
5 shared publicationsP. L. López-De-Alba
Univ. de Guanajuato (Mexico)
5 shared publications
Latest Publications
- Open Access
- 29 March 2017
- Published by David Publishing Company in Journal of Food Science and Engineering
- Vol. 7 (3)
Effect of Chia Seed on Physicochemical and Sensory Characteristics of Common Carp Restructured as Functional Food
- 29 March 2017
- Published by David Publishing Company in Journal of Food Science and Engineering
- Vol. 7 (3)
Open AccessEffect of Chia Seed on Physicochemical and Sensory Characteristics of Common Carp Restructured as Functional Food
- 15 August 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8011, 80112
Quantitative analysis of metformin in antidiabetic tablets by laser-induced breakdown spectroscopy
Nowadays the production of counterfeit and low quality drugs affects human health and generates losses to pharmaceutical industries and tax revenue losses to government. Currently there are several methods for pharmaceutical product analysis; nevertheless, most of them depend on complex and time consuming steps such as sample preparation. In contrast to conventional methods, Laser-induced breakdown spectroscopy (LIBS) is evaluated as a potential analytical technique for the rapid screening and quality control of anti-diabetic solid formulations. In this paper authors propose a simple method to analyze qualitatively and quantitatively Active Pharmaceutical Ingredients (APIs) such as Metformin hydrochloride. The authors used ten nanosecond duration pulses (FWHM) from a Nd:YAG laser produces the induced breakdown for the analysis. Light is collected and focused into a Cerny-Turner spectrograph and dispersed into an ICCD camera for its detection. We used atomic emissions from Chlorine atoms present only in APIs as analyte signal. The analysis was improved using Bromine as internal standard. Linear calibration curves from synthetic samples were prepared achieving linearity higher than 99%. Our results were compared with HPLC results and validation was performed by statistical methods. The validation analysis suggests that both methods have no significant differences i.e., the proposed method can be implemented for monitoring the pharmaceutical production process in-situ in real time or for inspection and recognition of authenticity.© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
- 15 August 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8011, 80112
Quantitative analysis of metformin in antidiabetic tablets by laser-induced breakdown spectroscopy
Nowadays the production of counterfeit and low quality drugs affects human health and generates losses to pharmaceutical industries and tax revenue losses to government. Currently there are several methods for pharmaceutical product analysis; nevertheless, most of them depend on complex and time consuming steps such as sample preparation. In contrast to conventional methods, Laser-induced breakdown spectroscopy (LIBS) is evaluated as a potential analytical technique for the rapid screening and quality control of anti-diabetic solid formulations. In this paper authors propose a simple method to analyze qualitatively and quantitatively Active Pharmaceutical Ingredients (APIs) such as Metformin hydrochloride. The authors used ten nanosecond duration pulses (FWHM) from a Nd:YAG laser produces the induced breakdown for the analysis. Light is collected and focused into a Cerny-Turner spectrograph and dispersed into an ICCD camera for its detection. We used atomic emissions from Chlorine atoms present only in APIs as analyte signal. The analysis was improved using Bromine as internal standard. Linear calibration curves from synthetic samples were prepared achieving linearity higher than 99%. Our results were compared with HPLC results and validation was performed by statistical methods. The validation analysis suggests that both methods have no significant differences i.e., the proposed method can be implemented for monitoring the pharmaceutical production process in-situ in real time or for inspection and recognition of authenticity.© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
- Open Access
- 1 January 2011
- Published by Hindawi Limited in The Scientific World Journal
- Vol. 11, 1005-1016
Treatment of a Textile Effluent from Dyeing with Cochineal Extracts UsingTrametes versicolorFungus
Trametes versicolor(Tv) fungus can degrade synthetic dyes that contain azo groups, anthraquinone, triphenylmethane polymers, and heterocyclic groups. However, no references have been found related to the degradation of natural dyes, such as the carminic acid that is contained in the cochineal extract. Experiments to determine the decolorization of the effluent used in the cotton dyeing process with cochineal extract by means of Tv fungus were done. Treatments to determine decolorization in the presence or absence of Kirk's medium, glucose, and fungus, with an addition of 50% (v v-1) of nonsterilized effluent were performed. Physicochemical characterization was performed at the start and end of the treatment. Degradation kinetics were determined. A direct relationship was found between the dry weight of fungi, pH, and the decolorization system, with higher decolorization at lower pH levels (pH ~4.3). High decolorization (81% ± 0.09; 88% ± 0.17; and 99% ± 0.04) for three of the eight treatments (Kirk's medium without glucose, Kirk's medium with glucose, and without medium with glucose, respectively) was found. Toxicity tests determined an increase in the initial effluent toxicity (7.33 TU) compared with the final treatment (47.73 TU) in a period of 11 days. For this system, a degradation sequence of the carminic acid structure present in the effluent by the Tv fungus is suggested, in which it is seen that metabolites still containing aromatic structures are generated.
- 1 January 2011
- Published by Hindawi Limited in The Scientific World Journal
- Vol. 11, 1005-1016
Open AccessTreatment of a Textile Effluent from Dyeing with Cochineal Extracts UsingTrametes versicolorFungus
Trametes versicolor(Tv) fungus can degrade synthetic dyes that contain azo groups, anthraquinone, triphenylmethane polymers, and heterocyclic groups. However, no references have been found related to the degradation of natural dyes, such as the carminic acid that is contained in the cochineal extract. Experiments to determine the decolorization of the effluent used in the cotton dyeing process with cochineal extract by means of Tv fungus were done. Treatments to determine decolorization in the presence or absence of Kirk's medium, glucose, and fungus, with an addition of 50% (v v-1) of nonsterilized effluent were performed. Physicochemical characterization was performed at the start and end of the treatment. Degradation kinetics were determined. A direct relationship was found between the dry weight of fungi, pH, and the decolorization system, with higher decolorization at lower pH levels (pH ~4.3). High decolorization (81% ± 0.09; 88% ± 0.17; and 99% ± 0.04) for three of the eight treatments (Kirk's medium without glucose, Kirk's medium with glucose, and without medium with glucose, respectively) was found. Toxicity tests determined an increase in the initial effluent toxicity (7.33 TU) compared with the final treatment (47.73 TU) in a period of 11 days. For this system, a degradation sequence of the carminic acid structure present in the effluent by the Tv fungus is suggested, in which it is seen that metabolites still containing aromatic structures are generated.
- 15 November 2009
- Published by Springer Nature in Microchimica Acta
- Vol. 167 (3-4) , 273-280
Coupled multisyringe flow injection/reactor tank for the spectrophotometric detection of azinphos methyl in water samples
- 15 November 2009
- Published by Springer Nature in Microchimica Acta
- Vol. 167 (3-4) , 273-280
Coupled multisyringe flow injection/reactor tank for the spectrophotometric detection of azinphos methyl in water samples
- 26 September 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7499, 74990
Spectroscopic analysis of pharmaceutical formulations through the use of chemometric tools
In this work, fast and reliable spectroscopic methods in combination with chemometric tools were developed for simultaneous determination of Acetylsalicylic Acid, Acetaminophen and Caffeine in commercial formulations. For the first-order multivariate calibration method (PLS-1), calibration and validation sets were constructed with 23 and 10 samples respectively according to a central composite design. The Micro-Raman, FTIR-HATR and UV absorption spectra in the region of 100-2000 cm-1, 400-4400 cm-1 and 200-350 nm, respectively, were recorded. The % REP's (Percentage of relative error of prediction) was less than 18 for all used spectroscopic techniques. Subsequently, commercial pharmaceutical samples were analyzed with percentage of recovery between 90 and 117% for the three compounds.
- 26 September 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7499, 74990
Spectroscopic analysis of pharmaceutical formulations through the use of chemometric tools
In this work, fast and reliable spectroscopic methods in combination with chemometric tools were developed for simultaneous determination of Acetylsalicylic Acid, Acetaminophen and Caffeine in commercial formulations. For the first-order multivariate calibration method (PLS-1), calibration and validation sets were constructed with 23 and 10 samples respectively according to a central composite design. The Micro-Raman, FTIR-HATR and UV absorption spectra in the region of 100-2000 cm-1, 400-4400 cm-1 and 200-350 nm, respectively, were recorded. The % REP's (Percentage of relative error of prediction) was less than 18 for all used spectroscopic techniques. Subsequently, commercial pharmaceutical samples were analyzed with percentage of recovery between 90 and 117% for the three compounds.
- 1 August 2009
- Published by Elsevier in Water Research
- Vol. 43 (14) , 3593-3603
Development of a TiO2 modified optical fiber electrode and its incorporation into a photoelectrochemical reactor for wastewater treatment
- 1 August 2009
- Published by Elsevier in Water Research
- Vol. 43 (14) , 3593-3603
Development of a TiO2 modified optical fiber electrode and its incorporation into a photoelectrochemical reactor for wastewater treatment
- 12 June 2009
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 281 (3) , 433-439
Multisyringe flow injection spectrophotometric determination of uranium in water samples
- 12 June 2009
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 281 (3) , 433-439
Multisyringe flow injection spectrophotometric determination of uranium in water samples
- 18 April 2008
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 391 (4) , 1119-1127
Determination of anticarcinogenic and rescue therapy drugs in urine by photoinduced spectrofluorimetry using multivariate calibration: comparison of several second-order methods
This paper shows the potential of excitation–emission fluorescence spectroscopy and several second-order methods, such as parallel factor analysis (PARAFAC), multiway partial least-squares (N-PLS) or bilinear least-squares (BLLS), as a multicalibration technique for the analysis of leucovorin (LV) and irinotecan (CPT-11). Although CPT-11 presents native fluorescence, leucovorin has little native fluorescence; however, under irradiation with short-wavelength UV light in the presence of traces of hydrogen peroxide, leucovorin was converted into a highly fluorescent compound. This reaction has been used for the sensitive and selective determination of both compounds. The convenience of analysing the total luminescence spectrum information when using multivariate calibration methods on fluorescence data is demonstrated. Direct determination of mixtures of both drugs in urine was accomplished on the basis of excitation–emission matrices (EEMs) and the three-way multivariate methods.
- 18 April 2008
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 391 (4) , 1119-1127
Determination of anticarcinogenic and rescue therapy drugs in urine by photoinduced spectrofluorimetry using multivariate calibration: comparison of several second-order methods
This paper shows the potential of excitation–emission fluorescence spectroscopy and several second-order methods, such as parallel factor analysis (PARAFAC), multiway partial least-squares (N-PLS) or bilinear least-squares (BLLS), as a multicalibration technique for the analysis of leucovorin (LV) and irinotecan (CPT-11). Although CPT-11 presents native fluorescence, leucovorin has little native fluorescence; however, under irradiation with short-wavelength UV light in the presence of traces of hydrogen peroxide, leucovorin was converted into a highly fluorescent compound. This reaction has been used for the sensitive and selective determination of both compounds. The convenience of analysing the total luminescence spectrum information when using multivariate calibration methods on fluorescence data is demonstrated. Direct determination of mixtures of both drugs in urine was accomplished on the basis of excitation–emission matrices (EEMs) and the three-way multivariate methods.
- 1 March 2008
- Published by Elsevier in Analytica Chimica Acta
- Vol. 611 (2) , 182-186
An environmental friendly method for the automatic determination of hypochlorite in commercial products using multisyringe flow injection analysis
- 1 March 2008
- Published by Elsevier in Analytica Chimica Acta
- Vol. 611 (2) , 182-186
An environmental friendly method for the automatic determination of hypochlorite in commercial products using multisyringe flow injection analysis