JZJiazi Zhang

Jiazi Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jiazi Zhang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A VSC-HVDC-Assisted Black-Start Strategy in Bulk Power Systems a Case Study in San Diego

    by Xiaofei Wang, Jiazi Zhang, Leonardo Rese, Mingjian Tuo, Hongfei Sun

    With the worldwide growth in deploying high-voltage direct current (HVDC) transmission systems, their ability to facilitate black-start (BS) restoration has been a research topic of interest. In this context, voltage source converter (VSC)-HVDC is regarded as a BS resource, and this paper proposes a VSC-HVDC-assisted parallel BS restoration strategy in bulk power systems. The proposed strategy consists of two stages: 1) determination of the VSC and generator startup sequence and 2) load restoration simulation. In the first stage, the entire blackout system is sectionalized into multiple subsystems. Each subsystem includes a VSC-HVDC station or traditional BS unit, it independently determines its generator startup timeline and the energization timelines for buses and lines. The second stage involves load restoration, conceptualized as a modified unit commitment problem, with the timelines established in the first stage work as critical inputs. The proposed BS restoration strategy is tested on the San Diego power system to simulate the 2011 Southwest blackout. The simulation results validate the effectiveness of using VSC-HVDC links as a BS resource which not only speeds up the restoration process but also reduces both energy and economic losses.


  • Open Access

    Data Availability and Integrity Attacks for Power Systems via Nonlinear Spatial-Temporal Modeling

    by Hongfei Sun, Dongliang Duan, Hongming Zhang, Seong Lok Choi, Jiazi Zhang, Xiaofei Wang, Haonan Wang, Jie Luo, Liuqing Yang

    Cybersecurity has become critical for modern power systems as they increasingly rely on digital communication and computational frameworks. Among cyber-attacks, Data Availability and Integrity Attacks (DAIA)—comprising availability attacks such as Denial-of-Service (DoS) and integrity attacks like replay attack—pose severe risks by degrading the reliability and usability of measurement data essential for operational decisionmaking. This paper presents a data-driven model using the Volterra series to address DAIA in complex power systems. The proposed model effectively captures spatial-temporal relationships, integrating multiple data sources with varying sampling rates while addressing nonlinear dynamics introduced by renewable energy integration. We develop a scalable anomaly detection framework that identifies such attack patterns, including replay attacks leveraging training data. Extensive simulations on the 240-bus WECC system demonstrate the model’s superior performance, achieving robust detection and accurate data recovery with practical computational requirements. Our work provides actionable insights and configuration guidelines for ensuring power system resilience against evolving cyber threats.


  • $N-1$ Reliability Makes It Difficult for False Data Injection Attacks to Cause Physical Consequences

    by Zhigang Chu, Jiazi Zhang, Oliver Kosut, Lalitha Sankar

    This paper demonstrates that false data injection (FDI) attacks are extremely limited in their ability to cause physical consequences on N-1 reliable power systems operating with real-time contingency analysis (RTCA) and security constrained economic dispatch (SCED). Prior work has shown that FDI attacks can be designed via an attacker-defender bi-level linear program (ADBLP) to cause physical overflows after re-dispatch using DCOPF. In this paper, it is shown that attacks designed using DCOPF fail to cause overflows on N-1 reliable systems because the system response modeled is inaccurate. An ADBLP that accurately models the system response is proposed to find the worst-case physical consequences, thereby modeling a strong attacker with system level knowledge. Simulation results on the synthetic Texas system with 2000 buses show that even with the new enhanced attacks, for systems operated conservatively due to N-1 constraints, the designed attacks only lead to post-contingency overflows. Moreover, the attacker must control a large portion of measurements and physically create a contingency in the system to cause consequences. Therefore, it is conceivable but requires an extremely sophisticated attacker to cause physical consequences on N-1 reliable power systems operated with RTCA and SCED.


  • Can Attackers With Limited Information Exploit Historical Data to Mount Successful False Data Injection Attacks on Power Systems?

    by Jiazi Zhang, Zhigang Chu, Lalitha Sankar, Oliver Kosut

    This paper studies physical consequences of unobservable false data injection (FDI) attacks designed only with information inside a subnetwork of the power system. The goal of this attack is to overload a chosen target line without being detected via measurements. To overcome the limited information, a multiple linear regression model is developed to learn the relationship between the external network and the attack subnetwork from historical data. The worst possible consequences of such FDI attacks are evaluated by solving a bi-level optimization problem wherein the first level models the limited attack resources, while the second level formulates the system response to such attacks via dc optimal power flow (OPF). The attack model with limited information is reflected in the dc OPF formulation that only takes into account the system information for the attack subnetwork. The vulnerability of this attack model is illustrated on the IEEE 24-bus reliability test system and the IEEE 118-bus systems.