ALAdam Lanzarotta

Adam Lanzarotta

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Adam Lanzarotta has a total of 114 co-authors. Here are the top co-authors by number of shared publications:

  • Lisa Lorenz

    Joint Intelligence National Threat Response – El Paso Illicit Drug (INTREPID) Laboratory Fort Bliss Texas USA

    7 shared publications
  • JaCinta Batson

    Joint Intelligence National Threat Response – El Paso Illicit Drug (INTREPID) Laboratory Fort Bliss Texas USA

    6 shared publications
  • JaCinta S. Batson

    US Food and Drug Administration Forensic Chemistry Center Cincinnati OH USA

    5 shared publications
  • Mark R. Witkowski

    Forensic Chemistry Center, Office of Regulatory Science, Office of Regulatory Affairs, US Food & Drug Administration, Cincinnati, OH 45237, USA

    4 shared publications
  • Mark Witkowski

    Joint Intelligence National Threat Response – El Paso Illicit Drug (INTREPID) Laboratory Fort Bliss Texas USA

    4 shared publications
  • Martin M. Kimani

    Forensic Chemistry Center, Office of Regulatory Science, Office of Regulatory Affairs, US Food & Drug Administration, Cincinnati, OH 45237, USA

    4 shared publications

Latest Publications

  • Detection of furosemide, sibutramine, and/or fluoxetine adulteration in “all natural” weight loss consumer products at an international mail facility satellite laboratory using handheld/portable rapid screening instruments

    by Michael D. Thatcher, Hannah E. Hill, Marie Marseille, Allison M. Reimer, Anvi Patel, Caroline M. Kelley, Brian L. Boyd, Christina Fernandez, Cierra D. Bell, Daurice J. McClain, et al.

    A total of 97 consumer products claiming to be “all natural” or providing label graphics indicating potential weight‐loss effects, were examined by a US Food and Drug Administration (FDA) National Forensic Chemistry Center (NFCC) International Mail Facility (IMF) satellite laboratory. All products were examined using a toolkit consisting of a handheld Raman spectrometer, portable Fourier‐transform infrared (FT‐IR) spectrometer, portable ambient ionization direct analysis in real‐time mass spectrometer (DART‐MS), and/or portable gas chromatography–mass spectrometry (GC–MS) instrument. Conclusive results were achieved for 89 out of 97 products using the satellite laboratory toolkit only. The remaining eight products were sent to the NFCC full‐service laboratory for additional analysis using liquid chromatography with mass spectrometry (LC–MS). All 97 products were found to be adulterated with active pharmaceutical ingredients (APIs), with each containing at least two of the following drugs: furosemide, sibutramine, and/or fluoxetine. Furosemide and fluoxetine are only available with a prescription and sibutramine is a Schedule IV controlled substance. Furthermore, sibutramine, fluoxetine, and furosemide are all under the scope of section 801(u) of the Federal Food, Drug, and Cosmetic Act (FD&C Act) and therefore have been identified by FDA as a significant public health risk. Overall, the results of this study helped prevent over 24,000 adulterated consumer product capsules from reaching unsuspecting American consumers during a two‐year timeframe.

  • The INTREPID program: Linking illicit fentanyl‐containing tablets and powders seized at US borders to a common origin by combining physical/chemical identifiers and machine learning

    by Adam Lanzarotta, Douglas Albright, JaCinta Batson, Brian Boyd, Jessica Carlotti, Terra Dassau, Jonathan C. Dumke, Larry Fluty, Hannah Godschalk, Meredith Goebel, et al.

    Three US government agencies, the Drug Enforcement Administration (DEA), Customs and Border Protection (CBP), and Food and Drug Administration (FDA), established a collaborative program to leverage each agency's expertise and capabilities to characterize illicit fentanyl‐containing tablets and powders collected at US ports of entry (POEs) for attribution and sourcing purposes. The Intelligence National Threat Response–El Paso Illicit Drug (INTREPID) program employed a proof‐of‐concept pilot study that combined physical and chemical analytical techniques with machine learning to establish comprehensive sample profiles. Samples were analyzed using complementary techniques including color imaging, three‐dimensional surface analysis, and multi‐technique chemical profiling (Raman, FT‐IR, GC–MS, LC–MS, ICP‐MS, 1 H NMR). Machine learning models were employed solely as screening tools to prioritize samples for detailed human analysis; all conclusions were based on direct analytical comparison, not on machine learning results. Physical analyses plausibly linked fentanyl tablet seizures from two different ports of entry collected 8 weeks apart based on consistent color characteristics and three‐dimensional debossing patterns. Chemical analyses plausibly linked fentanyl powder seizures from the same port of entry collected 3 h apart with identical qualitative profiles and minimal quantitative variation (16.7% concentration error). Although alternative explanations for the similarities observed between these sample pairs cannot be excluded, these findings demonstrate the feasibility of using combined physical and chemical data within a forensic intelligence framework to generate actionable leads for law enforcement investigations of illicit fentanyl trafficking networks.

  • Rapid Authenticity Testing of Alprazolam and Oxycodone Tablets Using Cloud-Based Portable Near-Infrared Technology

    by Hervé Rais, Lyndsay Kissell, Megan Sterling, Adam Lanzarotta, Olivier DelémOnt, Pierre Esseiva

    This study evaluated a low-cost hand-held near-infrared (NIR) spectrometer for rapid, nondestructive authenticity screening of seized tablets. Spectra were acquired from 225 tablets across four alprazolam and two oxycodone finished dosage forms, comprising 57 authentic or consistent with authentic (CWA) tablets and 168 not consistent with authentic (NCWA) tablets. The spectra were preprocessed using second-derivative Savitzky-Golay and Standard Normal Variate (SNV), then analyzed using Euclidean distance metrics, and additionally, supervised partial least-squares-discriminant analysis (PLS-DA) and one-class SIMCA models. Authentic and CWA tablets exhibited consistently low spectral intravariability, whereas NCWA tablets showed markedly higher intervariability, enabling complete separation for all six imprints. Under tablet-level leave-one-tablet-out cross-validation, conservative distance thresholds gave 100% correct classification. Taking the falsified tablet as the positive class, PLS-DA achieved 99.4% sensitivity and 100% specificity, while one-class SIMCA achieved 100% sensitivity and 98.2% specificity. The method delivers a definitive CWA versus NCWA decision in under 1 min without sample preparation, offering law enforcement, customs, forensic laboratories, and harm-reduction services a first-line tool to triage high-risk falsified opioids and benzodiazepines.

  • Leveraging Hydrogen Bond-Induced Peak Shifting to Determine Alcohol Concentration in Suspect Gel Hand Sanitizers Using Portable Infrared and Handheld Raman Spectrometers

    by Hannah LaRoy, Michael Thatcher, Lisa Lorenz, Martin Kimani, Merrie Jackson, Adam Lanzarotta

    This study assessed the feasibility of using portable infrared and handheld Raman devices for the rapid screening of alcohol-based gel hand sanitizers to detect potential adulteration or misbranding. Alcohol potency was estimated by analyzing the concentration-dependent hydrogen bond-induced peak shifting characteristic of alcohol–water mixtures. Specifically, alcohol concentration in water (v/v%) was plotted as a function of the ratio of two characteristic peak positions affected by this shifting, yielding linear responses between 30%–100% for infrared spectroscopy and 40%–100% for Raman spectroscopy. Calibration equations derived from these curves were applied to estimate alcohol concentration, resulting in average errors (± standard deviations) of 1.6% (1.2%) for infrared spectroscopy and 2.4% (1.7%) for Raman spectroscopy, compared to gas chromatography with flame ionization detection (GC-FID). A total of 24 products were analyzed using this screening workflow, with results used to prioritize samples for further analysis via official compendial methods. All 21 samples identified as violative or presumptively violative by the rapid screening devices were confirmed as violative using GC-FID, while all three samples classified as presumptively non-violative were confirmed as non-violative. This method may be suitable for field deployment at locations such as mail facilities, points of entry, and express courier hubs, where expedited screening of these products is beneficial. Its implementation could enhance regulatory enforcement efforts and support consumer safety by identifying non-compliant products more efficiently.

  • Analysis of unknown (unlabeled/mislabeled) drug products for active pharmaceutical ingredients and related substances by an international mail facility satellite laboratory equipped with rapid screening devices

    by Adam Lanzarotta, Sara Kern, JaCinta Batson, Melissa Collins, Anvi Patel, Muhammad Altaf, Julio Arrecis, Brian Boyd, Fernando Gonzalez Illan, Kelsey M. Griffin, et al.

    Two chemists employed a three‐device rapid screening “toolkit” consisting of a handheld Raman spectrometer, transportable mass spectrometer, and portable Fourier transform infrared (FT‐IR) spectrometer at an international mail facility (IMF) satellite laboratory to examine unknown (unlabeled/mislabeled) products for the presence of active pharmaceutical ingredients (APIs). Phase I of this project previously demonstrated that this toolkit was the most effective collection of instruments for identifying APIs in product types collected at IMFs during a nationwide mail blitz and Phase II of this project previously demonstrated that results generated using the toolkit during a satellite laboratory pilot program were as reliable as those generated by a full‐service library when two or more of these instruments identify an API. This study (Phase III) described the results of the satellite laboratory toolkit during production mode and encompassed the period ranging from June 2021 through December 2022. During this study, a total of 858 products were examined on‐site at the IMF. The satellite laboratory yielded conclusive results for 726 (84.6%) products, which were used to support regulatory action, and identified 132 (15.4%) products that required additional full‐service laboratory analyses due to inconclusive results. The satellite and full‐service laboratory verified/confirmed at least one API/related substance in 617 (71.9%) products. A total of 709 APIs/related substances were found in the 617 products, and 202 of these 709 compounds were unique/different. Overall, during Phases I through III of this program, 350 different substances have been identified in products collected at IMFs.


  • Evaluation of “Toolkit” consisting of handheld and portable analytical devices for detecting active pharmaceutical ingredients in drug products collected during a simultaneous nation-wide mail blitz

    by Adam Lanzarotta, Sara Kern, JaCinta Batson, Travis M. Falconer, Moseley Fulcher, Kirk W. Gaston, Martin M. Kimani, Lisa Lorenz, Flavia Morales-Garcia, Nicola Ranieri, et al.


  • Open Access

    Simultaneous Temperature Measurements and Aerosol Collection During Vaping for the Analysis of Δ9-Tetrahydrocannabinol and Vitamin E Acetate Mixtures in Ceramic Coil Style Cartridges

    by John Lynch, Lisa Lorenz, Jana L. Brueggemeyer, Adam Lanzarotta, Travis M. Falconer, Robert A. Wilson

    Incidence of e-cigarette, or vaping, product use-associated lung injury (EVALI) has been linked to the vaping of tetrahydrocannabinol (THC) products to which vitamin E acetate (VEA) has been added. In this work we vaped THC/VEA mixtures at elevated power levels using a variety of ceramic coil vaping cartridges and a commercially available vaping device, while simultaneously measuring temperature and collecting the vaporized condensate. The collected vapor condensate was analyzed for evidence of VEA decomposition by GC/MS, GC/FT-IR/MS, and LC-APCI-HRMS/MS. Mean temperature maxima for all examined cartridges at the selected power exceeded 430°C, with a range of 375–569°C, well beyond that required for thermal decomposition of VEA. The percent recovery of VEA and Δ9-THC from the vaporized mixture in six cartridges ranged from 71.5 to 101% and from 56.4 to 88.0%, respectively. Analysis of the condensed vaporized material identified VEA decomposition products duroquinone (DQ), 1-pristene, and durohydroquinone monoacetate (DHQMA); a compound consistent with 4-acetoxy-2,3,5-trimethyl-6-methylene-2,4-cyclohexadienone (ATMMC) was also detected. The concentration of DQ produced from vaporization of the THC/VEA mixture in one cartridge was found to be 4.16 ± 0.07 μg per mg of vapor condensate.


  • Rapid determination of eight benzodiazepines in suspected counterfeit pharmaceuticals using surface‐enhanced Raman scattering with handheld Raman spectrometers

    by Martin M. Kimani, Adam Lanzarotta, JaCinta S. Batson

    The excessive prescription of benzodiazepines is putting more people at risk of dependence on these drugs and is exacerbating the fatal overdose toll of opioids. A rapid and sensitive SERS method has been developed for trace detection of select benzodiazepines in low‐dosage suspect counterfeit tablets, capsules, and injectable solutions using two different portable handheld Raman spectrometers equipped with either a 785‐nm laser or a 1064‐nm laser. A total of 169 samples and blanks were examined using five handheld Raman spectrometers, which provided data set of 729 examinations. The extraction/SERS procedures yielded true positive rates above 90% for alprazolam, diazepam, and midazolam using the 1064‐nm device and yielded true positive rates above 95% for alprazolam, clonazepam, diazepam, estazolam, midazolam, and temazepam using the 785‐nm device; however, the extraction/SERS procedures yielded true positive rates below 60% for lorazepam and triazolam. The minimum concentration (Cmin) of the benzodiazepine standards that reproducibly yielded a positive match ranged from 1 to 10 μg/ml using the 1064‐nm laser device and from 0.5 to 50 μg/ml using the 785‐nm laser device. For the analysis of authentic and suspect counterfeit tablets containing these benzodiazepines, the measured Cmin ranged between 10 and 15 µg per tablet or capsule for 1064‐nm laser device and 1–100 µg per tablet or capsule for 785‐nm laser device. The developed methods are simple, rapid, and ideal for screening suspect benzodiazepine‐containing pharmaceutical products at satellite laboratories located within or near international mail facilities and express courier hubs.


  • Evaluation of four field portable devices for the rapid detection of mitragynine in suspected kratom products

    by Sarah E. Voelker, Sara E. Kern, Travis M. Falconer, Michael D. Thatcher, David M. Skelton, Kirk W. Gaston, Adam C. Lanzarotta, Lisa M. Lorenz, JaCinta S. Batson, Jonathan J. Litzau