Luciana Paulo Gomes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Luciana Paulo Gomes has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Marcelo Oliveira Caetano
Universidade do Vale do Rio dos Sinos, Brazil
18 shared publications - Luis Alcides Schiavo Miranda
Unisinos- São Leopoldo - Rio Grande do Sul - Brasil
5 shared publications - Amanda Gonçalves Kieling
Universidade do Vale do Rio dos Sinos, São Leopoldo, RS
4 shared publications - Carlos Alberto Mendes Moraes
Universidade do Vale do Rio dos Sinos
4 shared publications - Léa Beatriz Dai-Prá
Civil Engineering Post-Graduation Program, UNISINOS, São Leopoldo, Brazil
4 shared publications Vinicius Martins Marques
3 shared publications
Latest Publications
- Open Access
- 2 September 2025
- Published by RGSA- Revista de Gestao Social e Ambiental in Revista de Gestão Social e Ambiental
- Vol. 19 (9) , e013319
Electrolytic Treatment to Remove Apparent Color in Landfill Leachate
Introduction: The aim of this paper was to study the viability of to use the electrocoagulation in the treatment of landfill leachate to remove apparent color. The bench tests were performed using aluminum electrodes arranged as monopolar in parallel. The electric current, current density and electrical voltage were respectively set at 4,5; 300A/m² and 3,2V. To determinate the influence of monitoring time and ph on the treatment electrolytic efficiency was evaluated the the apparent color, electrical conductivity and turbity parametres. For this research step the results showed a better apparent color removal efficiency at ph = 5 (92.5%). From this choice, the ph 5 sample was analyzed for the concentration of ammoniacal nitrogen, total coliforms and COD. The leachate remotion was 58.75% of COD, 47.24% of total coliforms and no remotion in ammoniacal nitrogen. The treatment cost, considering the consumption of electric energy and aluminum electrodes, was estimated at US$ 3,00/m³ of treated leachate. Objective: The aim of this study was to evaluate the efficiency of landfill leachate treatment using electrocoagulation technology. Theoretical Framework: This section presents the main concepts and theories underlying the research. Highlights include the diagnosis of urban solid waste generation and disposal in Brazil. The theoretical framework also addresses leachate treatment technologies and landfills, as well as studies using electroflocculation as a potential wastewater treatment technology. Method: The methodology adopted for this research involves bench tests using aluminum electrodes arranged in a parallel monopolar arrangement. To evaluate the leachate treatment from the São Leopoldo/RS landfill, the influence of monitoring time and pH on the efficiency of the electrolytic treatment was assessed, considering the decreases in apparent color, turbidity, total coliform, COD, and ammonia nitrogen. Results and Discussion: The best leachate treatment efficiencies were obtained at pH = 5. The reductions obtained were 92.5%, 58.75%, and 47.24% for apparent color, COD, and total coliforms, respectively. The treatment cost was estimated at US$3.00/m³ of treated leachate. Research Implications: The practical and theoretical implications of this research are discussed, providing a practical basis for the use of electroflocculation technology for leachate treatment in landfills. This is a little-used treatment alternative for effluents, with advantages related to reduced chemical use and good efficiency. Originality/Value: The relevance and value of this research are briefly related to: the difficulty of treating landfill leachate, which is reflected in one of the highest operational costs of this operation, and the potential for using an underexplored technology in effluent treatment.
- 2 September 2025
- Published by RGSA- Revista de Gestao Social e Ambiental in Revista de Gestão Social e Ambiental
- Vol. 19 (9) , e013319
Open AccessElectrolytic Treatment to Remove Apparent Color in Landfill Leachate
Introduction: The aim of this paper was to study the viability of to use the electrocoagulation in the treatment of landfill leachate to remove apparent color. The bench tests were performed using aluminum electrodes arranged as monopolar in parallel. The electric current, current density and electrical voltage were respectively set at 4,5; 300A/m² and 3,2V. To determinate the influence of monitoring time and ph on the treatment electrolytic efficiency was evaluated the the apparent color, electrical conductivity and turbity parametres. For this research step the results showed a better apparent color removal efficiency at ph = 5 (92.5%). From this choice, the ph 5 sample was analyzed for the concentration of ammoniacal nitrogen, total coliforms and COD. The leachate remotion was 58.75% of COD, 47.24% of total coliforms and no remotion in ammoniacal nitrogen. The treatment cost, considering the consumption of electric energy and aluminum electrodes, was estimated at US$ 3,00/m³ of treated leachate. Objective: The aim of this study was to evaluate the efficiency of landfill leachate treatment using electrocoagulation technology. Theoretical Framework: This section presents the main concepts and theories underlying the research. Highlights include the diagnosis of urban solid waste generation and disposal in Brazil. The theoretical framework also addresses leachate treatment technologies and landfills, as well as studies using electroflocculation as a potential wastewater treatment technology. Method: The methodology adopted for this research involves bench tests using aluminum electrodes arranged in a parallel monopolar arrangement. To evaluate the leachate treatment from the São Leopoldo/RS landfill, the influence of monitoring time and pH on the efficiency of the electrolytic treatment was assessed, considering the decreases in apparent color, turbidity, total coliform, COD, and ammonia nitrogen. Results and Discussion: The best leachate treatment efficiencies were obtained at pH = 5. The reductions obtained were 92.5%, 58.75%, and 47.24% for apparent color, COD, and total coliforms, respectively. The treatment cost was estimated at US$3.00/m³ of treated leachate. Research Implications: The practical and theoretical implications of this research are discussed, providing a practical basis for the use of electroflocculation technology for leachate treatment in landfills. This is a little-used treatment alternative for effluents, with advantages related to reduced chemical use and good efficiency. Originality/Value: The relevance and value of this research are briefly related to: the difficulty of treating landfill leachate, which is reflected in one of the highest operational costs of this operation, and the potential for using an underexplored technology in effluent treatment.
- Open Access
- 4 June 2025
- Published by RGSA- Revista de Gestao Social e Ambiental in Revista de Gestão Social e Ambiental
- Vol. 19 (6) , e012713
Application of the Sustainable Construction Approach in the Design and Construction Phases: A Case Study
Objective: The objective of this study is to investigate the potential application of sustainable construction principles in the design and construction phases of a high-standard residential condominium, with the aim of proposing improvements that enhance its environmental, social, and economic feasibility, promoting the reduction of environmental impacts and strengthening sustainability in the construction sector. Theoretical Framework: This section presents the main concepts and theories that underpin the research. Notable among them are the principles of sustainable construction defined by Kibert (2020), such as reducing resource consumption, reusing materials, using renewable sources, protecting nature, eliminating toxic components, applying life cycle cost analysis, and focusing on quality. Additionally, the guidelines of Agenda 21 applied to the construction sector (Motta, 2009) and the assessment model based on the three dimensions of sustainability—environmental, social, and economic—are also considered. Method: The methodology adopted for this research comprises a qualitative case study focused on assessing the environmental sustainability of a residential project located in Canoas (RS), still in the pre-construction phase. The architectural, plumbing, electrical, and earthworks projects were analyzed, along with the descriptive memorial and site inspections. Data collection was carried out through the application of a checklist developed based on the principles of sustainable construction, considering aspects such as energy efficiency, use of sustainable materials, water and waste management, and environmental and economic impacts. Results and Discussion: The results revealed that the original project design presents several shortcomings in relation to sustainability criteria. Identified gaps include the absence of erosion control strategies, reliance on non-renewable energy sources, lack of individual water metering, and lack of specifications regarding the origin of construction materials. In the discussion, these results were contextualized based on the theoretical framework, highlighting the need for reformulating sustainable practices and guidelines in the sector. Limitations such as the project's early development stage and the lack of mandatory sustainability policies were also considered. Research Implications: The practical and theoretical implications of this research are discussed, providing insights into how the results may be applied or influence practices in the field of sustainable construction. These implications may encompass the development of public policies, financial incentives for sustainable projects, training of construction professionals, and restructuring of project design and urban planning guidelines. Originality/Value: This study contributes to the literature by demonstrating, through a concrete case study, how environmental sustainability criteria can be applied during the pre-construction phase, even in projects that did not initially include them. The originality lies in the practical approach using a customized checklist for assessment and improvement proposals. The relevance and value of this research are evidenced by its potential to guide future developments toward sustainable practices and by showcasing the economic, environmental, and social benefits of such an approach.
- 4 June 2025
- Published by RGSA- Revista de Gestao Social e Ambiental in Revista de Gestão Social e Ambiental
- Vol. 19 (6) , e012713
Open AccessApplication of the Sustainable Construction Approach in the Design and Construction Phases: A Case Study
Objective: The objective of this study is to investigate the potential application of sustainable construction principles in the design and construction phases of a high-standard residential condominium, with the aim of proposing improvements that enhance its environmental, social, and economic feasibility, promoting the reduction of environmental impacts and strengthening sustainability in the construction sector. Theoretical Framework: This section presents the main concepts and theories that underpin the research. Notable among them are the principles of sustainable construction defined by Kibert (2020), such as reducing resource consumption, reusing materials, using renewable sources, protecting nature, eliminating toxic components, applying life cycle cost analysis, and focusing on quality. Additionally, the guidelines of Agenda 21 applied to the construction sector (Motta, 2009) and the assessment model based on the three dimensions of sustainability—environmental, social, and economic—are also considered. Method: The methodology adopted for this research comprises a qualitative case study focused on assessing the environmental sustainability of a residential project located in Canoas (RS), still in the pre-construction phase. The architectural, plumbing, electrical, and earthworks projects were analyzed, along with the descriptive memorial and site inspections. Data collection was carried out through the application of a checklist developed based on the principles of sustainable construction, considering aspects such as energy efficiency, use of sustainable materials, water and waste management, and environmental and economic impacts. Results and Discussion: The results revealed that the original project design presents several shortcomings in relation to sustainability criteria. Identified gaps include the absence of erosion control strategies, reliance on non-renewable energy sources, lack of individual water metering, and lack of specifications regarding the origin of construction materials. In the discussion, these results were contextualized based on the theoretical framework, highlighting the need for reformulating sustainable practices and guidelines in the sector. Limitations such as the project's early development stage and the lack of mandatory sustainability policies were also considered. Research Implications: The practical and theoretical implications of this research are discussed, providing insights into how the results may be applied or influence practices in the field of sustainable construction. These implications may encompass the development of public policies, financial incentives for sustainable projects, training of construction professionals, and restructuring of project design and urban planning guidelines. Originality/Value: This study contributes to the literature by demonstrating, through a concrete case study, how environmental sustainability criteria can be applied during the pre-construction phase, even in projects that did not initially include them. The originality lies in the practical approach using a customized checklist for assessment and improvement proposals. The relevance and value of this research are evidenced by its potential to guide future developments toward sustainable practices and by showcasing the economic, environmental, and social benefits of such an approach.
- Open Access
- 2 May 2025
- Published by Brazilian Journals in REVISTA DELOS
- Vol. 18 (67) , e5019
Presence of 17β-estradiol, Bisphenol A and Caffeine in surface waters in the Guaiba Hydrographic Region (South of Brazil)
The aim of this article is to detect 03 micropollutants (17β-estradiol, Bisphenol A (BPA) and Caffeine) in surface water in the Guaiba Hydrographic Region, in south Brazil. In total, 10 sampling campaigns were executed in 03 different areas. To determine the concentration of micropollutants, solid phase extraction (SPE) and liquid chromatography coupled to a single quadruple mass spectrum detector with electrospray ionization (ESI) were used. The results showed the presence of high concentrations of these micropollutants in water, with values of 6,127.99 ng.L-1; 16,120.73 ng.L-1; and 2,110.24 ng.L-1 for 17β-estradiol, BPA, and Caffeine respectively. In this region, Sinos River has presented the highest concentrations compared to Gravatai River and São João Stream, for all micropollutants evaluated in this article. These high concentrations show us the need to monitor these levels, as they are sources of drinking water for public supply to the cities.
- 2 May 2025
- Published by Brazilian Journals in REVISTA DELOS
- Vol. 18 (67) , e5019
Open AccessPresence of 17β-estradiol, Bisphenol A and Caffeine in surface waters in the Guaiba Hydrographic Region (South of Brazil)
The aim of this article is to detect 03 micropollutants (17β-estradiol, Bisphenol A (BPA) and Caffeine) in surface water in the Guaiba Hydrographic Region, in south Brazil. In total, 10 sampling campaigns were executed in 03 different areas. To determine the concentration of micropollutants, solid phase extraction (SPE) and liquid chromatography coupled to a single quadruple mass spectrum detector with electrospray ionization (ESI) were used. The results showed the presence of high concentrations of these micropollutants in water, with values of 6,127.99 ng.L-1; 16,120.73 ng.L-1; and 2,110.24 ng.L-1 for 17β-estradiol, BPA, and Caffeine respectively. In this region, Sinos River has presented the highest concentrations compared to Gravatai River and São João Stream, for all micropollutants evaluated in this article. These high concentrations show us the need to monitor these levels, as they are sources of drinking water for public supply to the cities.
- Open Access
- 5 March 2025
- Published by RGSA- Revista de Gestao Social e Ambiental in Revista de Gestão Social e Ambiental
- Vol. 19 (3) , e011611
Presence of 17β-Estradiol, Bisphenol A and Caffeine in the Treatment Stages of A Water Treatment Plant (WTP)
Objective: The objective of this study is to show an evaluation of the presence of 17β-Estradiol, BPA, and Caffeine, in different stages of treatment in a conventional WTP, located in the South of Brazil. Theoretical Framework: The presence of micropollutants (drugs, hormones, etc.) in water sources is identified. These contaminants, although in low concentrations, can cause negative impacts on the environment and the health of the population. In Brazil, there is an aggravation due to deficiencies in basic sanitation. The national conventional water treatment plants are not efficient in removing these micropollutants, as they are not designed and operated for this purpose. Method: The methodology involved the collection of water samples from different processes of a Conventional Water Treatment Plant Case Study. The presence of 17β-estradiol, Bisphenol A (BPA), and Caffeine was evaluated. To determine the concentrations of these micropollutants, the Solid Phase Extraction (SPE) and Liquid Chromatography technique was used. Results and Discussion: Concentrations for RW ranged from 2.084 ng.L-1 up to 3.174 ng.L-1 for 17β-Estradiol, 0.029 ng.L-1 up to 0.064 ng.L-1 for Caffeine, and 1.951 ng.L-1 up to 7.753 ng.L-1 for BPA. For TW, the concentrations of 17β-estradiol, Caffeine, and BPA were respectively, <DL up to 2.821 ng.L-1, <DL up to 0.078 ng.L-1, and 1.154 ng.L-1 up to 2.229 ng.L-1. Research Implications: The research showed that there is presence of 17β-estradiol, Caffeine, and BPA in all stages of water treatment of the case study plant. This result confirmed the hypothesis that conventional water treatment plants used in Brazil may not be removing micropollutants. Originality/Value: The presence and detection of micropollutants in environmental matrices is still not regulated in the vast majority of countries. As this is a relatively recent topic, many researchers are seeking to understand the concentrations and effects of these contaminants on the environment and health. Therefore, any research that contributes to this database is considered relevant. In the case of this work, the presence of 17β-Estradiol, BPA, Caffeine; Micropollutants in all stages of a conventional national Water Treatment Plant, including in the drinking water that is distributed to the population, stands out. In other words, there is a risk of serious impacts on the quality of the water that reaches the taps of homes.
- 5 March 2025
- Published by RGSA- Revista de Gestao Social e Ambiental in Revista de Gestão Social e Ambiental
- Vol. 19 (3) , e011611
Open AccessPresence of 17β-Estradiol, Bisphenol A and Caffeine in the Treatment Stages of A Water Treatment Plant (WTP)
Objective: The objective of this study is to show an evaluation of the presence of 17β-Estradiol, BPA, and Caffeine, in different stages of treatment in a conventional WTP, located in the South of Brazil. Theoretical Framework: The presence of micropollutants (drugs, hormones, etc.) in water sources is identified. These contaminants, although in low concentrations, can cause negative impacts on the environment and the health of the population. In Brazil, there is an aggravation due to deficiencies in basic sanitation. The national conventional water treatment plants are not efficient in removing these micropollutants, as they are not designed and operated for this purpose. Method: The methodology involved the collection of water samples from different processes of a Conventional Water Treatment Plant Case Study. The presence of 17β-estradiol, Bisphenol A (BPA), and Caffeine was evaluated. To determine the concentrations of these micropollutants, the Solid Phase Extraction (SPE) and Liquid Chromatography technique was used. Results and Discussion: Concentrations for RW ranged from 2.084 ng.L-1 up to 3.174 ng.L-1 for 17β-Estradiol, 0.029 ng.L-1 up to 0.064 ng.L-1 for Caffeine, and 1.951 ng.L-1 up to 7.753 ng.L-1 for BPA. For TW, the concentrations of 17β-estradiol, Caffeine, and BPA were respectively, <DL up to 2.821 ng.L-1, <DL up to 0.078 ng.L-1, and 1.154 ng.L-1 up to 2.229 ng.L-1. Research Implications: The research showed that there is presence of 17β-estradiol, Caffeine, and BPA in all stages of water treatment of the case study plant. This result confirmed the hypothesis that conventional water treatment plants used in Brazil may not be removing micropollutants. Originality/Value: The presence and detection of micropollutants in environmental matrices is still not regulated in the vast majority of countries. As this is a relatively recent topic, many researchers are seeking to understand the concentrations and effects of these contaminants on the environment and health. Therefore, any research that contributes to this database is considered relevant. In the case of this work, the presence of 17β-Estradiol, BPA, Caffeine; Micropollutants in all stages of a conventional national Water Treatment Plant, including in the drinking water that is distributed to the population, stands out. In other words, there is a risk of serious impacts on the quality of the water that reaches the taps of homes.
- Open Access
- 5 September 2024
- Published by RGSA- Revista de Gestao Social e Ambiental in Revista de Gestão Social e Ambiental
- Vol. 18 (10) , e09038
Reuse of Textile Waste: Products Presentation and User Acceptance Analysis
Objective: This research evaluateded the potential use of clothing produced from textile waste generated. In addition to showcasing products made from reused materials, the study investigated the public's knowledge of these practices and assessed consumer acceptance. Theoretical Framework: In this topic, the main concepts and theories that underpin the research are presented. The discussion on sustainability and the brazilian panorama of textile waste stand out, providing a solid basis for understanding the context of the investigation. Method: The research was descriptive and predominantly quantitative. Data were collected using a questionnaire answered by 215 people. Results and Discussion: It was noted that clothing made from textile waste is well accepted by society. However, the difficulty in finding these items and the price of products represent a challenge for many people. Although many participants said they were aware of the possibility of making garments from this waste, many did not know how to identify the origin of the waste. Research Implications: The practical and theoretical implications of this research are discussed, providing insights into how the results can be applied or influence practices in the field of textile waste utilization. These implications may cover areas such as waste management and the development of the brazilian economy. Originality/Value: The adoption of alternatives for using textile waste is extremely important. Although there are already people working in this segment, its market share is still small. These issues affirm the relevance of this research for strengthening this segment.
- 5 September 2024
- Published by RGSA- Revista de Gestao Social e Ambiental in Revista de Gestão Social e Ambiental
- Vol. 18 (10) , e09038
Open AccessReuse of Textile Waste: Products Presentation and User Acceptance Analysis
Objective: This research evaluateded the potential use of clothing produced from textile waste generated. In addition to showcasing products made from reused materials, the study investigated the public's knowledge of these practices and assessed consumer acceptance. Theoretical Framework: In this topic, the main concepts and theories that underpin the research are presented. The discussion on sustainability and the brazilian panorama of textile waste stand out, providing a solid basis for understanding the context of the investigation. Method: The research was descriptive and predominantly quantitative. Data were collected using a questionnaire answered by 215 people. Results and Discussion: It was noted that clothing made from textile waste is well accepted by society. However, the difficulty in finding these items and the price of products represent a challenge for many people. Although many participants said they were aware of the possibility of making garments from this waste, many did not know how to identify the origin of the waste. Research Implications: The practical and theoretical implications of this research are discussed, providing insights into how the results can be applied or influence practices in the field of textile waste utilization. These implications may cover areas such as waste management and the development of the brazilian economy. Originality/Value: The adoption of alternatives for using textile waste is extremely important. Although there are already people working in this segment, its market share is still small. These issues affirm the relevance of this research for strengthening this segment.
- Open Access
- 2 January 2024
- Published by Brazilian Journals in Contribuciones A Las Ciencias Sociales
- Vol. 17 (1) , 7758-7776
Análise das condições ergonômicas e de produtividade decorrentes da movimentação manual de sacos de cimento de 25 kg e 50 kg em canteiros de obras da construção civil
Tarefas como levantar, abaixar, segurar e movimentar cargas exige um empenho elevado de esforços musculares. Neste contexto, este trabalho identificou a influência dos fatores ergonômicos na saúde e bem-estar dos trabalhadores e sua relação com a produtividade em tarefas de movimentação manual de sacos de cimento. A metodologia baseou-se na análise da movimentação manual de sacos de cimento de 25 kg e 50 kg em um mesmo percurso, no qual foram registradas as variáveis ambientais, as variáveis relacionadas à produtividade e as variáveis fisiológicas de três trabalhadores executando esta tarefa. Os resultados mostraram que para a variável tempo de execução, o manuseio de sacos de cimento de 50 kg é mais indicado. Contudo, para as variáveis de produtividade (percepção do trabalhador quanto à condição física e percepção do esforço), fisiológicas (frequência cardíaca, capacidade cardiovascular, e variação de temperatura corporal) e para as análises dos levantamentos, há uma indicação para o manuseio de sacos de cimento de 25 kg. A pesquisa conclui que, ao considerar as situações avaliadas, há indícios de que os fatores ergonômicos relacionados ao manuseio de sacos de cimento de 50 kg podem impactar o desempenho do trabalhador, com a possibilidade de causar sobrecarga física e muscular.
- 2 January 2024
- Published by Brazilian Journals in Contribuciones A Las Ciencias Sociales
- Vol. 17 (1) , 7758-7776
Open AccessAnálise das condições ergonômicas e de produtividade decorrentes da movimentação manual de sacos de cimento de 25 kg e 50 kg em canteiros de obras da construção civil
Tarefas como levantar, abaixar, segurar e movimentar cargas exige um empenho elevado de esforços musculares. Neste contexto, este trabalho identificou a influência dos fatores ergonômicos na saúde e bem-estar dos trabalhadores e sua relação com a produtividade em tarefas de movimentação manual de sacos de cimento. A metodologia baseou-se na análise da movimentação manual de sacos de cimento de 25 kg e 50 kg em um mesmo percurso, no qual foram registradas as variáveis ambientais, as variáveis relacionadas à produtividade e as variáveis fisiológicas de três trabalhadores executando esta tarefa. Os resultados mostraram que para a variável tempo de execução, o manuseio de sacos de cimento de 50 kg é mais indicado. Contudo, para as variáveis de produtividade (percepção do trabalhador quanto à condição física e percepção do esforço), fisiológicas (frequência cardíaca, capacidade cardiovascular, e variação de temperatura corporal) e para as análises dos levantamentos, há uma indicação para o manuseio de sacos de cimento de 25 kg. A pesquisa conclui que, ao considerar as situações avaliadas, há indícios de que os fatores ergonômicos relacionados ao manuseio de sacos de cimento de 50 kg podem impactar o desempenho do trabalhador, com a possibilidade de causar sobrecarga física e muscular.
- Open Access
- 1 November 2023
- Published by IWA Publishing in Journal of Water and Health
- Vol. 21 (11) , 1716-1726
Comparison of 17β-estradiol, bisphenol-A and caffeine concentration levels before and after the water treatment plant
This article compares the concentration levels of 17β-estradiol (E2), bisphenol-A (BPA) and caffeine (CAF) in the Sinos River, Brazil, which is a source of drinking water and the presence of contaminants after the conventional treatment in a municipal water treatment plant (WTP). A total of nine sampling campaigns were carried out, with sample collection in the Sinos River, upstream and downstream of the WTP, in addition to a drinking water sample (DW). The samples were extracted with solid phase extraction (SPE) and the concentration by liquid chromatography coupled to mass spectrometry (LC-MS). The maximum concentration in the Sinos River was 6,127.99 ng·L−1 for E2, 3,294.63 ng·L−1 for BPA and 1,221.95 ng·L−1 for CAF. In drinking water, the concentration range of E2, BPA and CAF was from less than the Detection Limit (DL) up to 437.50 ng·L−1, <DL up to 2,573.34 ng·L−1 and <DL up to 832.30 ng·L−1, respectively. In conclusion, the concentrations of these pollutants present in the Sinos River are high, which may represent a negative environmental impact on this water source. Drinking water indicates the need for a new treatment process that could promote the removal of these compounds.
- 1 November 2023
- Published by IWA Publishing in Journal of Water and Health
- Vol. 21 (11) , 1716-1726
Open AccessComparison of 17β-estradiol, bisphenol-A and caffeine concentration levels before and after the water treatment plant
This article compares the concentration levels of 17β-estradiol (E2), bisphenol-A (BPA) and caffeine (CAF) in the Sinos River, Brazil, which is a source of drinking water and the presence of contaminants after the conventional treatment in a municipal water treatment plant (WTP). A total of nine sampling campaigns were carried out, with sample collection in the Sinos River, upstream and downstream of the WTP, in addition to a drinking water sample (DW). The samples were extracted with solid phase extraction (SPE) and the concentration by liquid chromatography coupled to mass spectrometry (LC-MS). The maximum concentration in the Sinos River was 6,127.99 ng·L−1 for E2, 3,294.63 ng·L−1 for BPA and 1,221.95 ng·L−1 for CAF. In drinking water, the concentration range of E2, BPA and CAF was from less than the Detection Limit (DL) up to 437.50 ng·L−1, <DL up to 2,573.34 ng·L−1 and <DL up to 832.30 ng·L−1, respectively. In conclusion, the concentrations of these pollutants present in the Sinos River are high, which may represent a negative environmental impact on this water source. Drinking water indicates the need for a new treatment process that could promote the removal of these compounds.
- Open Access
- 6 April 2022
- Published by Universidad Nacional Autonoma de Mexico in Revista AIDIS de Ingeniería y Ciencias Ambientales. Investigación, desarrollo y práctica
- Vol. 15 (1) , 86
LINER PARA IMPERMEABILIZAÇÃO DE ATERROS SANITÁRIOS UTILIZANDO RESÍDUOS DE CONSTRUÇÃO E DEMOLIÇÃO
LINER PARA IMPERMEABILIZAÇÃO DE ATERROS SANITÁRIOS UTILIZANDO RESÍDUOS DE CONSTRUÇÃO E DEMOLIÇÃO
- 6 April 2022
- Published by Universidad Nacional Autonoma de Mexico in Revista AIDIS de Ingeniería y Ciencias Ambientales. Investigación, desarrollo y práctica
- Vol. 15 (1) , 86
Open AccessLINER PARA IMPERMEABILIZAÇÃO DE ATERROS SANITÁRIOS UTILIZANDO RESÍDUOS DE CONSTRUÇÃO E DEMOLIÇÃO
LINER PARA IMPERMEABILIZAÇÃO DE ATERROS SANITÁRIOS UTILIZANDO RESÍDUOS DE CONSTRUÇÃO E DEMOLIÇÃO
- 25 March 2022
- Published by Emerald Publishing in International Journal of Sustainability in Higher Education
- Vol. 24 (2) , 361-381
Maintenance of an environmental management system based on ISO 14001 in a Brazilian private university, seeking sustainable development
Purpose: This study aims to present the environmental management system implemented at UNISINOS and demonstrate some of the main results obtained in more than 15 years carrying out the environmental management of the campuses in São Leopoldo and Porto Alegre. The focus is on the main environmental impacts: electricity consumption, water consumption and solid waste management. Design/methodology/approach: Sustainable development of universities has gradually become a common practice, as the knowledge shared in the higher education institutions reflects in the behavior of society. In a university, an environmental management system is used to plan, implement and manage processes referring to the environmental, social and economic aspects, so as to improve their performance and comply with legal requirements. For this, national or international standards and/or methodologies can be followed, which serve as a guide for the institution to reach sustainability in a staggered manner, according to the availability of data and resources for environmental management. Findings: After 16 years of certification, based on the monitoring performed, positive performance was observed, reflecting a better and attentive university, with an environmental policy that goes beyond the borders of the campuses and transmits solid concepts of environmental education to the academic community, under the rigid control of the ISO 14001 tool. Originality/value: In 2004, UNISINOS became the first Latin American university with an ISO 14001 certification. In 2018, the certification was extended to the UNISINOS Campus in Porto Alegre, capital of the state of Rio Grande do Sul. All the support activities conducted and implemented in the campuses (São Leopoldo and Porto Alegre) follow the same rules implemented by the UNISINOS environmental management system. After the experience of implementing the ISO 14001 requirements, UNISINOS included other normative requirements in 2013, adopting an integrated management system.
- 25 March 2022
- Published by Emerald Publishing in International Journal of Sustainability in Higher Education
- Vol. 24 (2) , 361-381
Maintenance of an environmental management system based on ISO 14001 in a Brazilian private university, seeking sustainable development
Purpose: This study aims to present the environmental management system implemented at UNISINOS and demonstrate some of the main results obtained in more than 15 years carrying out the environmental management of the campuses in São Leopoldo and Porto Alegre. The focus is on the main environmental impacts: electricity consumption, water consumption and solid waste management. Design/methodology/approach: Sustainable development of universities has gradually become a common practice, as the knowledge shared in the higher education institutions reflects in the behavior of society. In a university, an environmental management system is used to plan, implement and manage processes referring to the environmental, social and economic aspects, so as to improve their performance and comply with legal requirements. For this, national or international standards and/or methodologies can be followed, which serve as a guide for the institution to reach sustainability in a staggered manner, according to the availability of data and resources for environmental management. Findings: After 16 years of certification, based on the monitoring performed, positive performance was observed, reflecting a better and attentive university, with an environmental policy that goes beyond the borders of the campuses and transmits solid concepts of environmental education to the academic community, under the rigid control of the ISO 14001 tool. Originality/value: In 2004, UNISINOS became the first Latin American university with an ISO 14001 certification. In 2018, the certification was extended to the UNISINOS Campus in Porto Alegre, capital of the state of Rio Grande do Sul. All the support activities conducted and implemented in the campuses (São Leopoldo and Porto Alegre) follow the same rules implemented by the UNISINOS environmental management system. After the experience of implementing the ISO 14001 requirements, UNISINOS included other normative requirements in 2013, adopting an integrated management system.
- Open Access
- 1 February 2022
- Published by FapUNIFESP (SciELO) in Engenharia Sanitaria e Ambiental
- Vol. 27 (1) , 91-101
Efficiency of electrocoagulation in the treatment of laundromat greywater
The high consumption of water and the generation of greywater in laundromats underscore the need to investigate advanced treatment techniques to reuse this effluent. Based on the estimated growth figures of the laundromat sector in Brazil, this study looked into the efficiency of electrocoagulation to treat laundromat greywater. Electrodes were connected to an EC reactor on a monopolar parallel connection mode, with electric current of 6 A and current density of 400 A.m2. The highest efficiency to treat laundromat greywater was observed at a distance of 15 mm between electrodes, voltage of 17.14 V, and operation time of 30 min, when the removal values of apparent color, true color, turbidity, biochemical oxygen demand, chemical oxygen demand, and surfactants were 92, 97, 88, 91, 98, and 96%, respectively. Electrode consumption was measured at 1.82 g.h, while energy consumption was 20.54 kWh.m3 and the total cost was US$ 4.10 per cubic meter of treated effluent. However, despite the high efficiency of the treatment, reuse of treated laundromat effluent requires polishing in order to meet the standards defined by Brazilian regulations.
- 1 February 2022
- Published by FapUNIFESP (SciELO) in Engenharia Sanitaria e Ambiental
- Vol. 27 (1) , 91-101
Open AccessEfficiency of electrocoagulation in the treatment of laundromat greywater
The high consumption of water and the generation of greywater in laundromats underscore the need to investigate advanced treatment techniques to reuse this effluent. Based on the estimated growth figures of the laundromat sector in Brazil, this study looked into the efficiency of electrocoagulation to treat laundromat greywater. Electrodes were connected to an EC reactor on a monopolar parallel connection mode, with electric current of 6 A and current density of 400 A.m2. The highest efficiency to treat laundromat greywater was observed at a distance of 15 mm between electrodes, voltage of 17.14 V, and operation time of 30 min, when the removal values of apparent color, true color, turbidity, biochemical oxygen demand, chemical oxygen demand, and surfactants were 92, 97, 88, 91, 98, and 96%, respectively. Electrode consumption was measured at 1.82 g.h, while energy consumption was 20.54 kWh.m3 and the total cost was US$ 4.10 per cubic meter of treated effluent. However, despite the high efficiency of the treatment, reuse of treated laundromat effluent requires polishing in order to meet the standards defined by Brazilian regulations.