Catarina Silva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Catarina Silva has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Maria João Rosa
Urban Water Unit, LNEC—National Laboratory for Civil Engineering, Av. Brasil 101, 1700-066 Lisboa, Portugal
24 shared publications - Rui Manuel Carvalho Viegas
Urban Water Unit, LNEC—National Laboratory for Civil Engineering, Av. Brasil 101, 1700-066 Lisboa, Portugal
6 shared publications - Margarida Campinas
Urban Water Unit, LNEC—National Laboratory for Civil Engineering, Av. Brasil 101, 1700-066 Lisboa, Portugal
5 shared publications - Gabriela Faria
TRATAVE—Tratamento de Águas Residuais do Ave S.A., Rua ETAR de Serzedelo, 4765-543 Serzedelo GMR, Portugal
3 shared publications - Helena Alegre
Senior Researcher at LNEC (National Civil Engineering Laboratory)
3 shared publications - Cláudio Costa
TRATAVE—Tratamento de Águas Residuais do Ave S.A., Rua ETAR de Serzedelo, 4765-543 Serzedelo GMR, Portugal
2 shared publications
Latest Publications
- Open Access
Forecasting the Removal of Chemical Contaminants of Emerging Concern in Activated Sludge Treatment—A Practical, Site-Calibrated Model Supporting Implementation of the EU Urban Wastewater Treatment Directive Recast
A practical model to forecast the removal of contaminants of emerging concern (CECs) in activated sludge (AS) wastewater treatment plants (WWTPs) was developed. Eight full-scale campaigns were conducted in three AS-WWTPs (seven reactor datasets); 57 CECs were analyzed, 22 quantified in influent, and 13 CECs used for model calibration. The previously observed sigmoidal correlation between CEC removal and biodegradation rate (kbio) was validated and a pseudo-first-order kinetic model was adapted to include a lumped correction factor ‘a’ in addition to Mixed Liquor Suspended Solids (MLSS), Hydraulic Retention Time, and a CEC biodegradation constant (kbio). Model transferability was assessed using two WWTPs from a previous study. A global ‘a’ value provided a first approximation, while site-specific calibration improved R2 from 0.71–0.83 to 0.90–0.95. ‘a’ ranged from 0.19 (oxidation ditch; nitrification rate 5.8 g N-NH4/(kgVSS·d)) to 0.61 (anaerobic/anoxic/oxic AS system; 27 g N-NH4/(kg VSS·d)). The model supports AS operational scenario analysis and integration with advanced treatments to meet the 80% CEC (micropollutant) removal target of the revised Urban Wastewater Treatment Directive. In an illustrative ForecastTool scenario, increasing MLSS from 3 to 5 g/L increased AS removal of six CECs (from the twelve listed in the directive) from 32% to 45%, reducing the modeled ozone dose from 16 to 12 g/m3. The model requires site-specific calibration of ‘a’.
Open AccessForecasting the Removal of Chemical Contaminants of Emerging Concern in Activated Sludge Treatment—A Practical, Site-Calibrated Model Supporting Implementation of the EU Urban Wastewater Treatment Directive Recast
A practical model to forecast the removal of contaminants of emerging concern (CECs) in activated sludge (AS) wastewater treatment plants (WWTPs) was developed. Eight full-scale campaigns were conducted in three AS-WWTPs (seven reactor datasets); 57 CECs were analyzed, 22 quantified in influent, and 13 CECs used for model calibration. The previously observed sigmoidal correlation between CEC removal and biodegradation rate (kbio) was validated and a pseudo-first-order kinetic model was adapted to include a lumped correction factor ‘a’ in addition to Mixed Liquor Suspended Solids (MLSS), Hydraulic Retention Time, and a CEC biodegradation constant (kbio). Model transferability was assessed using two WWTPs from a previous study. A global ‘a’ value provided a first approximation, while site-specific calibration improved R2 from 0.71–0.83 to 0.90–0.95. ‘a’ ranged from 0.19 (oxidation ditch; nitrification rate 5.8 g N-NH4/(kgVSS·d)) to 0.61 (anaerobic/anoxic/oxic AS system; 27 g N-NH4/(kg VSS·d)). The model supports AS operational scenario analysis and integration with advanced treatments to meet the 80% CEC (micropollutant) removal target of the revised Urban Wastewater Treatment Directive. In an illustrative ForecastTool scenario, increasing MLSS from 3 to 5 g/L increased AS removal of six CECs (from the twelve listed in the directive) from 32% to 45%, reducing the modeled ozone dose from 16 to 12 g/m3. The model requires site-specific calibration of ‘a’.
- Open Access
Life Cycle Assessment and Comparative Cost Analysis of Removing Contaminants of Emerging Concern from Urban Wastewater by Activated Sludge Treatment and Ozonation
In response to the paradigm shift in urban wastewater treatment that has been driven by emerging regulatory requirements for the removal of chemical contaminants of emerging concern (CECs), it has become essential to evaluate the environmental and economic implications of wastewater treatment upgrades using Life Cycle Assessment (LCA) and comparative cost analysis. The present study evaluates, using full-scale operational data, strategies that can be used in activated sludge systems and downstream ozonation that target CECs and conventional pollutants. Human toxicity, global warming, freshwater ecotoxicity, and freshwater eutrophication were considered midpoint categories, whereas human health and freshwater ecosystems were assessed as endpoint categories, together with a comparative cost analysis. The results show that higher CEC removals mainly reduced freshwater ecotoxicity, although this improvement had a relatively minor effect on the freshwater ecosystems endpoint, which was mostly driven by nutrient emissions. Higher ozone doses reduced the impacts on freshwater ecosystems due to enhanced CEC removal, but increased costs and negatively affected human health, mainly through the impacts of global warming that are associated with electrical energy consumption and oxygen production and transport. Ozonation showed total unit costs of 0.065–0.083 €/m3, and the smallest impacts on freshwater ecosystems under the tested conditions were observed at costs around 0.07 €/m3, corresponding to organic-carbon-normalized ozone doses of approximately 0.8 mgO3/mgC. Integrating LCA and cost analysis supports the identification of environmental–economic trade-offs when selecting wastewater treatment strategies. However, the application of LCA to CEC removal remains limited by the lack of characterization factors for many CECs, which may lead to underestimation of CEC-related impacts, although the magnitude of this potential bias remains uncertain. Further development of CEC characterization factors and site-specific environmental–economic assessment is therefore important to support treatment and regulatory decisions.
Open AccessLife Cycle Assessment and Comparative Cost Analysis of Removing Contaminants of Emerging Concern from Urban Wastewater by Activated Sludge Treatment and Ozonation
In response to the paradigm shift in urban wastewater treatment that has been driven by emerging regulatory requirements for the removal of chemical contaminants of emerging concern (CECs), it has become essential to evaluate the environmental and economic implications of wastewater treatment upgrades using Life Cycle Assessment (LCA) and comparative cost analysis. The present study evaluates, using full-scale operational data, strategies that can be used in activated sludge systems and downstream ozonation that target CECs and conventional pollutants. Human toxicity, global warming, freshwater ecotoxicity, and freshwater eutrophication were considered midpoint categories, whereas human health and freshwater ecosystems were assessed as endpoint categories, together with a comparative cost analysis. The results show that higher CEC removals mainly reduced freshwater ecotoxicity, although this improvement had a relatively minor effect on the freshwater ecosystems endpoint, which was mostly driven by nutrient emissions. Higher ozone doses reduced the impacts on freshwater ecosystems due to enhanced CEC removal, but increased costs and negatively affected human health, mainly through the impacts of global warming that are associated with electrical energy consumption and oxygen production and transport. Ozonation showed total unit costs of 0.065–0.083 €/m3, and the smallest impacts on freshwater ecosystems under the tested conditions were observed at costs around 0.07 €/m3, corresponding to organic-carbon-normalized ozone doses of approximately 0.8 mgO3/mgC. Integrating LCA and cost analysis supports the identification of environmental–economic trade-offs when selecting wastewater treatment strategies. However, the application of LCA to CEC removal remains limited by the lack of characterization factors for many CECs, which may lead to underestimation of CEC-related impacts, although the magnitude of this potential bias remains uncertain. Further development of CEC characterization factors and site-specific environmental–economic assessment is therefore important to support treatment and regulatory decisions.
- Open Access
- 17 August 2026
- Published by MDPI AG in Preprints.org
Forecasting the Removal of Micropollutants and Chemical Contaminants of Emerging Concern in Activated Sludge Treatment—A Practical Model Supporting the Implementation of the New EU Directive on Urban Wastewater Treatment
A practical model to forecast the removal of micropollutants and other chemical Contaminants of Emerging Concern (CECs) in Activated Sludge (AS) systems was developed. Full-scale campaigns were carried out in three AS-WWTPs to evaluate the influence of the Mixed Liquor Suspended Solids (MLSS), Hydraulic Retention Time (HRT), and nitrification conditions. The previously observed sigmoidal correlation between CEC removal and biodegradation rate (kbio) was validated and a pseudo-first-order kinetic model was adapted to include, in addition to MLSS, HRT, kbio, a lumped-correction factor ‘a’. The transferability of the approach was further assessed using data from two WWTPs analysed in a previous study. The “a” value ranged from 0.19 (oxidation ditch at a nitrification rate of 5.8 g N-NH4/(kg VSS·d)) to 0.61 (A2O with 27 g N-NH4/(kg VSS·d)), suggesting a potential influence of reactor configuration and nitrification activity. This model allows WWTP managers optimizing AS performance and assessing its combination with advanced treatments needed to comply with the 80% removal efficiency for micropollutant indicators set by the revised Urban Wastewater Treatment Directive. Increasing MLSS from 2 to 5 g/L, increases AS removal from 23% to 45% and thus decreases ozone dose from 20 to 12 g/m3.
- 17 August 2026
- Published by MDPI AG in Preprints.org
Open AccessForecasting the Removal of Micropollutants and Chemical Contaminants of Emerging Concern in Activated Sludge Treatment—A Practical Model Supporting the Implementation of the New EU Directive on Urban Wastewater Treatment
A practical model to forecast the removal of micropollutants and other chemical Contaminants of Emerging Concern (CECs) in Activated Sludge (AS) systems was developed. Full-scale campaigns were carried out in three AS-WWTPs to evaluate the influence of the Mixed Liquor Suspended Solids (MLSS), Hydraulic Retention Time (HRT), and nitrification conditions. The previously observed sigmoidal correlation between CEC removal and biodegradation rate (kbio) was validated and a pseudo-first-order kinetic model was adapted to include, in addition to MLSS, HRT, kbio, a lumped-correction factor ‘a’. The transferability of the approach was further assessed using data from two WWTPs analysed in a previous study. The “a” value ranged from 0.19 (oxidation ditch at a nitrification rate of 5.8 g N-NH4/(kg VSS·d)) to 0.61 (A2O with 27 g N-NH4/(kg VSS·d)), suggesting a potential influence of reactor configuration and nitrification activity. This model allows WWTP managers optimizing AS performance and assessing its combination with advanced treatments needed to comply with the 80% removal efficiency for micropollutant indicators set by the revised Urban Wastewater Treatment Directive. Increasing MLSS from 2 to 5 g/L, increases AS removal from 23% to 45% and thus decreases ozone dose from 20 to 12 g/m3.
- Open Access
Tackling Urban Water Resilience: Exploiting the Potential of Smart Water Allocation in the Lisbon Living Lab
Climate change is widening the mismatch between water supply and water demand in urban areas, affecting both. Additionally, water demand is increasing due to population growth and economic development. Water allocation is a key component of sustainable urban water management and, unlike traditional approaches, must rely on a fit-for-purpose principle, where water is valued by its quality adequacy based on the use rather than by its source, with water reuse playing a central role in urban water resilience. This paper presents a novel framework, together with the step-by-step process for its application—the smart water allocation process (SWAP) for urban non-potable uses—and the developed software toolset to facilitate the decision-making process by urban managers, water utilities, and other stakeholders. It was developed within the context of a living lab to accelerate the innovation uptake. The demand–supply matchmaking and the plan module are comprehensively described and the SWAP results and their contribution to water resilience in Lisbon are discussed. Three water allocation alternatives were defined to implement different strategies, conservation, redundancy and reuse, in two green area clusters. Synergy with climate action funding was identified. The application of the SWAP enabled decision-making based on factual evidence and fostered intuitive understanding of the urban water resilience challenges.
Open AccessTackling Urban Water Resilience: Exploiting the Potential of Smart Water Allocation in the Lisbon Living Lab
Climate change is widening the mismatch between water supply and water demand in urban areas, affecting both. Additionally, water demand is increasing due to population growth and economic development. Water allocation is a key component of sustainable urban water management and, unlike traditional approaches, must rely on a fit-for-purpose principle, where water is valued by its quality adequacy based on the use rather than by its source, with water reuse playing a central role in urban water resilience. This paper presents a novel framework, together with the step-by-step process for its application—the smart water allocation process (SWAP) for urban non-potable uses—and the developed software toolset to facilitate the decision-making process by urban managers, water utilities, and other stakeholders. It was developed within the context of a living lab to accelerate the innovation uptake. The demand–supply matchmaking and the plan module are comprehensively described and the SWAP results and their contribution to water resilience in Lisbon are discussed. Three water allocation alternatives were defined to implement different strategies, conservation, redundancy and reuse, in two green area clusters. Synergy with climate action funding was identified. The application of the SWAP enabled decision-making based on factual evidence and fostered intuitive understanding of the urban water resilience challenges.
- Open Access
- 15 December 2023
- Published by IWA Publishing
- p. 141-180
Controlling organic micropollutants in urban (waste) water treatment by activated carbon adsorption and membrane technology
Population growth and aging, as well as water scarcity driven by climate change call for an enhanced control of organic micropollutants and contaminan
- 15 December 2023
- Published by IWA Publishing
- p. 141-180
Open AccessControlling organic micropollutants in urban (waste) water treatment by activated carbon adsorption and membrane technology
Population growth and aging, as well as water scarcity driven by climate change call for an enhanced control of organic micropollutants and contaminan
- Open Access
- 25 October 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (21) , 15273
Quality of Urban Water Services Provided to Users: Assessment System and the Portuguese Path through Four Generations, Lessons Learned and New Challenges
Public water supply, urban wastewater and stormwater management, and urban waste management are structural public services, essential to well-being, public health, and the safety of populations as well as to economic activities and environmental protection. These services must be guided by principles of universal access, continuity and quality of service, and efficiency and fairness of applied tariffs. The main concern of the regulation of these services is the protection of the interests of the users through the promotion of the quality of the service provided by the water utilities and the guarantee of balance in the practiced tariffs, materialized in the principles of universality, equity, reliability, and cost-efficiency. The quality of the urban water services has been assessed by ERSAR (the Portuguese regulator) since 2004, when the first generation of the assessment system was developed, and has undergone three periodical critical revisions. The fourth generation, developed in 2021, entered in force in 2022. This paper presents the fourth generation of ERSAR’s system for assessing the quality of urban water services in Continental Portugal, focusing on the path followed and addressing the experience of its application over almost two decades, the lessons learned, and the new challenges for the water sector.
- 25 October 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (21) , 15273
Open AccessQuality of Urban Water Services Provided to Users: Assessment System and the Portuguese Path through Four Generations, Lessons Learned and New Challenges
Public water supply, urban wastewater and stormwater management, and urban waste management are structural public services, essential to well-being, public health, and the safety of populations as well as to economic activities and environmental protection. These services must be guided by principles of universal access, continuity and quality of service, and efficiency and fairness of applied tariffs. The main concern of the regulation of these services is the protection of the interests of the users through the promotion of the quality of the service provided by the water utilities and the guarantee of balance in the practiced tariffs, materialized in the principles of universality, equity, reliability, and cost-efficiency. The quality of the urban water services has been assessed by ERSAR (the Portuguese regulator) since 2004, when the first generation of the assessment system was developed, and has undergone three periodical critical revisions. The fourth generation, developed in 2021, entered in force in 2022. This paper presents the fourth generation of ERSAR’s system for assessing the quality of urban water services in Continental Portugal, focusing on the path followed and addressing the experience of its application over almost two decades, the lessons learned, and the new challenges for the water sector.
- Open Access
- 28 August 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (17) , 12965
Integrating Reliability and Energy Efficiency Assessments for Pinpointing Actionable Strategies for Enhanced Performance of Urban Wastewater Treatment Plants
By leveraging performance assessment systems (PASs) and incorporating targeted strategies, utilities can enhance the overall effectiveness, reliability, efficiency, and environmental performance of their wastewater treatment facilities. This work presents the results obtained from a comprehensive analysis of treatment reliability and energy performance of three wastewater treatment plants (WWTPs). The results allowed identifying, for each WWTP, improvement needs related to the aeration energy requirements, as well as to determine the effluent concentration targets required to achieve higher reliability levels while potentially reducing running costs. By analysing reliability combined with energy efficiency, this methodology allowed identifying the WWTPs’ performance-limiting stages or dysfunctions that affect both effectiveness and efficiency, to estimate the investment needs and prioritize the rehabilitation or even retrofitting of facilities’ assets.
- 28 August 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (17) , 12965
Open AccessIntegrating Reliability and Energy Efficiency Assessments for Pinpointing Actionable Strategies for Enhanced Performance of Urban Wastewater Treatment Plants
By leveraging performance assessment systems (PASs) and incorporating targeted strategies, utilities can enhance the overall effectiveness, reliability, efficiency, and environmental performance of their wastewater treatment facilities. This work presents the results obtained from a comprehensive analysis of treatment reliability and energy performance of three wastewater treatment plants (WWTPs). The results allowed identifying, for each WWTP, improvement needs related to the aeration energy requirements, as well as to determine the effluent concentration targets required to achieve higher reliability levels while potentially reducing running costs. By analysing reliability combined with energy efficiency, this methodology allowed identifying the WWTPs’ performance-limiting stages or dysfunctions that affect both effectiveness and efficiency, to estimate the investment needs and prioritize the rehabilitation or even retrofitting of facilities’ assets.
- Open Access
A Comprehensive Derivation and Application of Reference Values for Benchmarking the Energy Performance of Activated Sludge Wastewater Treatment
Wastewater treatment plants (WWTPs) are facing challenges concerning the service’s effectiveness and reliability, as well as the efficiency and sustainability of resource utilization, where energy represents one of the higher costs in activated sludge (AS) treatment. This paper presents the latest developments in the new energy performance indices (PXs) we have been developing for benchmarking, i.e., assessing and improving the performance of this widely used treatment. PXs compare the energy consumption with the energy requirements for the carbon and nitrogen removals needed for the plant’s compliance with the discharge consents (the closer they are, the better the performance). PXs are computed by applying to the state variables a performance function that is defined by the reference values for excellent, acceptable, and unsatisfactory performance. This paper shows the rationale for selecting the state variables for the AS energy performance and the comprehensive derivation of the equations to determine the reference values for energy consumption, which incorporate the effect of key parameters (flows, concentrations, and operating conditions). Reference values for the operating conditions affecting the energy performance are also proposed. A sensitivity analysis identified the key parameters for improving the aeration performance: α, F, and SOTE for air diffusers, and α and N0 for mechanical aerators. Fourteen Portuguese urban WWTPs (very diverse in size and inflows) were analyzed, and aeration (0.08–1.03 kWh/m3) represented 25–80% of total energy consumption (0.23–1.30 kWh/m3). The reference values for excellent performance were 0.23–0.39 kWh/m3 (P25–P75) for AS systems with air diffusers and 0.33–0.80 kWh/m3 for those with mechanical aerators. A comprehensive application in one WWTP (16–18 d solids retention time) showed the system’s ability at identifying which operating conditions to adjust (to F/M ratio lower than 0.09 d−1 and decreasing aeration during the low season) to improve the energy performance/savings while maintaining the treatment’s effectiveness and reliability.
Open AccessA Comprehensive Derivation and Application of Reference Values for Benchmarking the Energy Performance of Activated Sludge Wastewater Treatment
Wastewater treatment plants (WWTPs) are facing challenges concerning the service’s effectiveness and reliability, as well as the efficiency and sustainability of resource utilization, where energy represents one of the higher costs in activated sludge (AS) treatment. This paper presents the latest developments in the new energy performance indices (PXs) we have been developing for benchmarking, i.e., assessing and improving the performance of this widely used treatment. PXs compare the energy consumption with the energy requirements for the carbon and nitrogen removals needed for the plant’s compliance with the discharge consents (the closer they are, the better the performance). PXs are computed by applying to the state variables a performance function that is defined by the reference values for excellent, acceptable, and unsatisfactory performance. This paper shows the rationale for selecting the state variables for the AS energy performance and the comprehensive derivation of the equations to determine the reference values for energy consumption, which incorporate the effect of key parameters (flows, concentrations, and operating conditions). Reference values for the operating conditions affecting the energy performance are also proposed. A sensitivity analysis identified the key parameters for improving the aeration performance: α, F, and SOTE for air diffusers, and α and N0 for mechanical aerators. Fourteen Portuguese urban WWTPs (very diverse in size and inflows) were analyzed, and aeration (0.08–1.03 kWh/m3) represented 25–80% of total energy consumption (0.23–1.30 kWh/m3). The reference values for excellent performance were 0.23–0.39 kWh/m3 (P25–P75) for AS systems with air diffusers and 0.33–0.80 kWh/m3 for those with mechanical aerators. A comprehensive application in one WWTP (16–18 d solids retention time) showed the system’s ability at identifying which operating conditions to adjust (to F/M ratio lower than 0.09 d−1 and decreasing aeration during the low season) to improve the energy performance/savings while maintaining the treatment’s effectiveness and reliability.
- Open Access
A Treatment Reliability-Based Method for Supporting Infrastructure Asset Management of Wastewater Treatment Plants
A simple and consolidated reliability-based method widely used to unveil the real reliability and stability of wastewater treatment plants (WWTPs) is herein proposed to trigger decision making on operational improvements and asset management for maintaining or improving treatment effectiveness, reliability, and efficiency. Five-year data (2015–2019) from 16 Portuguese activated sludge WWTPs were used. For the 73% of the yearly data which fitted a lognormal distribution, Niku’s coefficient was computed to assess the plant annual reliability for biological oxygen demand (BOD5), chemical oxygen demand (COD), and total suspended solids (TSS). The standard deviation of the annual concentrations was used to characterize the plant stability, and the maximum standard deviations allowed to comply with the European discharge requirements for urban WWTPs were derived. The results demonstrate extended aeration WWTPs were more reliable and stable than conventional aeration WWTPs (0.98 reliability vs. 0.82 for BOD5, 0.97 vs. 0.91 for COD, and 0.94 vs. 0.89 for TSS). Furthermore, the lower reliabilities and stabilities were found for the smaller WWTPs. These results are important for strategic asset management for designing and rehabilitation of the wastewater treatment system. At tactical and operational levels, for resources’ allocation and operating conditions set up, the computed WWTP’s coefficient of variation allows establishing the mean effluent concentrations required for compliance with a given reliability for different scenarios of discharge requirements.
Open AccessA Treatment Reliability-Based Method for Supporting Infrastructure Asset Management of Wastewater Treatment Plants
A simple and consolidated reliability-based method widely used to unveil the real reliability and stability of wastewater treatment plants (WWTPs) is herein proposed to trigger decision making on operational improvements and asset management for maintaining or improving treatment effectiveness, reliability, and efficiency. Five-year data (2015–2019) from 16 Portuguese activated sludge WWTPs were used. For the 73% of the yearly data which fitted a lognormal distribution, Niku’s coefficient was computed to assess the plant annual reliability for biological oxygen demand (BOD5), chemical oxygen demand (COD), and total suspended solids (TSS). The standard deviation of the annual concentrations was used to characterize the plant stability, and the maximum standard deviations allowed to comply with the European discharge requirements for urban WWTPs were derived. The results demonstrate extended aeration WWTPs were more reliable and stable than conventional aeration WWTPs (0.98 reliability vs. 0.82 for BOD5, 0.97 vs. 0.91 for COD, and 0.94 vs. 0.89 for TSS). Furthermore, the lower reliabilities and stabilities were found for the smaller WWTPs. These results are important for strategic asset management for designing and rehabilitation of the wastewater treatment system. At tactical and operational levels, for resources’ allocation and operating conditions set up, the computed WWTP’s coefficient of variation allows establishing the mean effluent concentrations required for compliance with a given reliability for different scenarios of discharge requirements.
- Open Access
- 7 November 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (21) , 12293
A Practical Methodology for Forecasting the Impact of Changes in Influent Loads and Discharge Consents on Average Energy Consumption and Sludge Production by Activated Sludge Wastewater Treatment
This paper proposes a simple and easy-to-use methodology for forecasting the impact of changes in influent chemical oxygen demand (COD) and in the emission limit values (ELVs) of COD and total nitrogen on average energy requirements for aeration and sludge production by activated sludge wastewater treatment plants (WWTPs). The methodology is based on mass balances of sludge production and oxygen requirements for carbonaceous material biodegradation and/or nitrification, oxygen transfer and aeration equipment efficiency. Using average values of historical data of regular monitoring (water quality and operating conditions) WWTP-specific equations of oxygen requirements, energy consumption and sludge production are derived as a function of influent COD and influent N-total, which may be used to quantify the impact of influent and ELV changes. The methodology was tested in five extended aeration WWTPs for three scenarios established by the utility. The results show that increasing influent COD, from 900 to 1300 mg/L, for example, significantly increases the energy consumption by 49% and sludge production by 53%. For influent 54–68 mg/L N-total, imposing 15 mgN/L ELV results in a 9–26% increase in energy consumption. The COD ELV change studied (season-specific, from 150 mg/L 12 months/year to 125 mg/L 8 months/year to 100 mg/L 4 months/year) increases the energy consumption by 1.8–2.6% and the sludge production by 4.3–5.4%.
- 7 November 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (21) , 12293
Open AccessA Practical Methodology for Forecasting the Impact of Changes in Influent Loads and Discharge Consents on Average Energy Consumption and Sludge Production by Activated Sludge Wastewater Treatment
This paper proposes a simple and easy-to-use methodology for forecasting the impact of changes in influent chemical oxygen demand (COD) and in the emission limit values (ELVs) of COD and total nitrogen on average energy requirements for aeration and sludge production by activated sludge wastewater treatment plants (WWTPs). The methodology is based on mass balances of sludge production and oxygen requirements for carbonaceous material biodegradation and/or nitrification, oxygen transfer and aeration equipment efficiency. Using average values of historical data of regular monitoring (water quality and operating conditions) WWTP-specific equations of oxygen requirements, energy consumption and sludge production are derived as a function of influent COD and influent N-total, which may be used to quantify the impact of influent and ELV changes. The methodology was tested in five extended aeration WWTPs for three scenarios established by the utility. The results show that increasing influent COD, from 900 to 1300 mg/L, for example, significantly increases the energy consumption by 49% and sludge production by 53%. For influent 54–68 mg/L N-total, imposing 15 mgN/L ELV results in a 9–26% increase in energy consumption. The COD ELV change studied (season-specific, from 150 mg/L 12 months/year to 125 mg/L 8 months/year to 100 mg/L 4 months/year) increases the energy consumption by 1.8–2.6% and the sludge production by 4.3–5.4%.