Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Dong-Jin Lee has a total of 70 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Reusable and Soft Self-Adhesive Epidermal Electrodes for Human Skin Enabled by Functional Additives

    by Sungmin Bae, Dong-Jin Lee, Chuljin Hwang, Dae Yu Kim

    Wearable electronics, particularly dry epidermal electrodes, provide human-connected interfaces for recording biopotential signals. However, their practical utility is often hindered by their limited operational longevity and the resulting environmental burden of electronic waste, as most conventional electrodes are discarded after a single use because of performance degradation. Herein, a reusable, soft, and conductive epidermal electrode is reported, fabricated through the precise incorporation of functional additives. By intentionally modulating the polymer chain architecture, a homogeneous composite is developed that exhibits exceptional flexibility, high conductivity (~100 S/cm), softness (~649 kPa), and stretchability (~234%). This molecular-level design promotes strong intermolecular interactions at the skin–electrode interface, facilitating persistent adhesion and conformability to challenging surfaces, including wet, wrinkled, and stretched skin. These properties enable reliable electrocardiography acquisition through 50 repeated attachment and detachment cycles, over which a commercial Ag/AgCl gel electrode became unmeasurable after 20. The applicability of the electrode to human–machine interfaces is further demonstrated by capturing clear electromyography signals of muscle activity during a rock–paper–scissors game. This low-modulus electrode platform offers a route towards repeated-use wearable healthcare systems and soft-robotics applications, with the potential to reduce the waste associated with single-use electrodes.

  • Open Access

    Numerical Investigation of Microporous Insulation for Power Reduction in Zero-Heat-Flux Thermometry

    by Dong-Jin Lee, Dae Yu Kim

    Zero-heat-flux (ZHF) thermometry is a clinically validated method for non-invasive core body temperature monitoring, yet its broad adoption in wearable applications is constrained by the high power consumption of the heater element. In this study, we numerically investigate the role of microporous insulation in minimizing energy demand while preserving measurement accuracy. A three-dimensional finite element model of a ZHF probe was implemented in COMSOL Multiphysics 5.4, consisting of a resistive heater, a microporous insulation shell, and a skin-equivalent substrate regulated by proportional–integral–derivative (PID) control. A Taguchi L9 orthogonal array was utilized to systematically investigate the effects of porosity (0–90%), insulation thickness (2–4 mm), and the convective heat transfer coefficient (5–15 W/m2·K) on the thermal performance of the ZHF thermometry system. Two performance metrics—heater energy consumption and settling time—were analyzed using analysis of variance (ANOVA). The results indicated that porosity accounted for more than 95% of the variance in heater power and over 80% of the variance in settling time. The configuration with φ = 90% and t = 3 mm demonstrated a balanced trade-off between energy efficiency and transient response for low-power ZHF thermometry. These findings provide design insights for energy-efficient wearable temperature sensors.

  • Open Access

    Enhanced Electrical Injury Using Triangular Interdigitated Electrodes for Catheter-Based Irreversible Electroporation

    by Dong-Jin Lee, Dae Yu Kim

    Irreversible electroporation (IRE) is a promising nonthermal ablation technique that uses high-voltage electrical pulses to create permanent pores in the cell membrane of target tissue. Recently, endoscopic IRE with catheter-based electrodes has attracted significant attention as a potential alternative tool for gastrointestinal tumors, but it has been challenged owing to the limited electric field distribution in an in-plane electrode configuration, in which rectangular interdigitated electrodes (IDEs) are commonly used. Herein, we report an enhanced electrical injury in tissue using triangular IDEs that cause strong electric fields to be induced at the tip of the electrode fingers. A set of 10 pulses with a duration of 100 μs and a frequency of 1 Hz were delivered to the tissue, and a finite element method was used to calculate the electrical injury in the gastrointestinal model. The probability of cell death by electrical injury at the triangular IDEs increases by approximately 10 times compared to that of conventional rectangular IDEs at the same electrode distance. These results could potentially pave the way toward designing electrodes in catheter-based IRE devices.


  • Symmetric nonconfocal Fabry–Perot cavity with a stable long optical path length and improved tolerance for angular alignment

    by Dong-Jin Lee, Beom-Hoan O

    Engineering of optical alignment tolerance between a laser source and a Fabry–Perot (FP) cavity is of great importance in optimizing a laser analysis system and saving costs in the additional alignment task. We propose a modification of the conventional confocal FP (CFP) cavity–a symmetric nonconfocal FP (SNFP) cavity with two identical spherical mirrors separated by a distance equal to half of the common radius of curvature. Numerical analysis of the two cavities reveals that the SNFP cavity has better off-axis stability and much better angular misalignment tolerance than the CFP cavity, even with a longer optical path length (OPL). The SNFP cavity provides a six-transit path length for a basic cavity mode that supports a 1.5-fold long OPL within the same volume as the CFP cavity, which is favorable for applications requiring limits on the footprint and weight of the cavity. In addition, a ray-tracing simulation with a disk-type source having an angular Gaussian distribution (α = β = 5 deg) reveals that the emission beam profile from the SNFP cavity is narrower than that from the CFP cavity. These results are expected to help reduce cavity loss and to improve alignment efficiency between the laser source and the FP cavity.


  • Open Access

    UV Irradiation-Induced SERS Enhancement in Randomly Distributed Au Nanostructures

    by Dong-Jin Lee, Dae Yu Kim

    Currently used platforms for surface-enhanced Raman scattering (SERS) sensors generally employ metallic nanostructures for enrichment of the plasmonic hotspots in order to provide higher Raman signals, but this procedure is still considered challenging for analyte–surface affinity. This study reports a UV irradiation-induced SERS enhancement that amplifies the interactions between the analytes and metallic surfaces. The UV light can play critical roles in the surface cleaning to improve the SERS signal by removing the impurities from the surfaces and the formation of the negatively charged adsorbed oxygen species on the Au surfaces to enhance the analyte–surface affinity. To evaluate this scenario, we prepared randomly distributed Au nanostructures via thermal annealing with a sputtered Au thin film. The UV light of central wavelength 254 nm was then irradiated on the Au nanostructures for 60 min. The SERS efficiency of the Au nanostructures was subsequently evaluated using rhodamine 6G molecules as the representative Raman probe material. The Raman signal of the Au nanostructures after UV treatment was enhanced by up to approximately 68.7% compared to that of those that did not receive the UV treatment. We expect that the proposed method has the potential to be applied to SERS enhancement with various plasmonic platforms.


  • Open Access

    Hydrophobic Paper-Based SERS Sensor Using Gold Nanoparticles Arranged on Graphene Oxide Flakes

    by Dong-Jin Lee, Dae Yu Kim

    Paper-based surface-enhanced Raman scattering (SERS) sensors have garnered much attention in the past decade owing to their ubiquity, ease of fabrication, and environmentally friendly substrate. The main drawbacks of a paper substrate for a SERS sensor are its high porosity, inherent hygroscopic nature, and hydrophilic surface property, which reduce the sensitivity and reproducibility of the SERS sensor. Here, we propose a simple, quick, convenient, and economical method for hydrophilic to hydrophobic surface modification of paper, while enhancing its mechanical and moisture-resistant properties. The hydrophobic paper (h-paper) was obtained by spin-coating diluted polydimethylsiloxane (PDMS) solution onto the filter paper, resulting in h-paper with an increased contact angle of up to ≈130°. To complete the h-paper-based SERS substrate, gold nanoparticles arranged on graphene oxide (AuNPs@GO) were synthesized using UV photoreduction, followed by drop-casting of AuNPs@GO solution on the h-paper substrate. The enhancement of the SERS signal was then assessed by attaching a rhodamine 6G (R6G) molecule as a Raman probe material to the h-paper-based SERS substrate. The limit of detection was 10 nM with an R2 of 0.966. The presented SERS sensor was also tested to detect a thiram at the micromolar level. We expect that our proposed AuNPs@GO/h-paper-based SERS sensor could be applied to point-of-care diagnostics applications in daily life and in spacecraft.


  • Photobiomodulation Therapy in Mice with Chronic Cerebral Hypoperfusion Using Application-Specific Near-Infrared Light-Emitting Diode System

    by Dong-Jin Lee, Ha-Young Jang, Ki-Wook Moon, Eun-Joo Lee, A-Ram Yoo, Woo Sung Choi, Chang Kyu Sung, Dae Yu Kim


  • Near-infrared light therapy for recovery of cerebral hypoperfusion induced by bilateral common carotid artery stenosis in mice

    by Dong-Jin Lee, Ha-Young Jang, Ki-Wook Moon, Eun-Joo Lee, A-Ram Yoo, Woo Sung Choi, Chang Kyu Sung, Jae Hun Kim, Dae Yu Kim

    Low-level light therapy, which is a red or near-infrared light-employed therapeutic methodology, can act to help the brain repair in cases of traumatic brain injury and stroke. In this paper, we investigate the effects of near-infrared light therapy (NILT) for the recovery of blood flow of mice with cerebral hypoperfusion, which is a key mechanism leading to vascular dementia, induced by bilateral common carotid artery stenosis (BCAS). The mice are divided into three groups of 4-5 mice per group: a normal group (without BCAS operation), a BCAS group (without NILT), or a BCAS/NILT group. The LED with a peak wavelength of 810 nm and a power of 20 mW is arranged to illuminate on the top of the mouse head. The mice receive treatment from the LED source 3 times per week for one month. After the treatment, positron emission tomography is used to quantify the effects of NILT on whole brain and regional cerebral blood flow in the cortex, striatum, and hippocampus.

  • Open Access

    Paper-Based, Hand-Painted Strain Sensor Based on ITO Nanoparticle Channels for Human Motion Monitoring

    by Dong-Jin Lee, Dae Yu Kim

    Paper-based strain sensors have attracted attention as a cost-effective and environmentally friendly approach to wearable electronic devices. This study proposes a paper-based strain sensor created solely using hand-painting, which is a simple, equipment-free process utilized in green electronics. Commercial printing paper is coated with polydimethylsiloxane diluted with heptane, which provides moisture resistance and mechanical robustness while increasing the hydrophobicity of the surface. The electrodes and conduction channels are fabricated using a pencil for graphite deposition and a brush for the deposition of tin-doped indium oxide nanoparticles, respectively. With a gauge factor of 41.98 in tensile strain tests and 21.36 in compressive strain tests, our strain sensor exhibits a good sensitivity that is similar to that of previously reported paper-based sensors. We also demonstrate that our proposed strain sensor can be used as a weak motion detection device for humans and robots.


  • Paper-based hydrogen peroxide sensors using porphyrin with central ions of Ti

    by Dong-Jin Lee, Sun Ho Kim, Young Tae Byun

    We demonstrate the paper-based hydrogen peroxide sensors for the biomedical and healthcare applications. Porphyrin with central ions of Ti is coated on a PDMS/paper substrate, and Au interdigitated electrodes are sputtered on the porphyrin/PDMS/paper substrate for the sensor applications. The fabricated sensors show a good response in the range of ca. 2 ~ 90 ppm of hydrogen peroxide vapor, and high selectivity to NH 3 , H 2 S, CO, and NO gases, which are representative biomarkers including exhaled breath.