Aamir Raja
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Aamir Raja has a total of 338 co-authors. Here are the top co-authors by number of shared publications:
Nanette Schleich
Department of Radiation Therapy, University of Otago, Wellington, New Zealand
12 shared publicationsAli Atharifard
MARS Bioimaging Ltd., Christchurch, New Zealand
11 shared publicationsLieza Vanden Broeke
MARS Bioimaging Ltd., Christchurch, New Zealand
11 shared publicationsMahdieh Moghiseh
Department of Radiology, University of Otago Christchurch, Christchurch, New Zealand
11 shared publicationsSrinidhi Bheesette
Department of Radiology, University of Otago Christchurch, Christchurch, New Zealand
11 shared publicationsAysouda Matanaghi
Department of Radiology, University of Otago Christchurch, Christchurch, New Zealand
10 shared publications
Latest Publications
- Open Access
- 9 April 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (4) , e0346825
Voxel-wise deep learning segmentation of hydroxyapatite and iodine in spectral photon-counting CT: A quantitative phantom study
Accurate non-invasive identification of hydroxyapatite (HA) deposits is important for diagnosing calcific musculoskeletal disease and quantifying vascular calcification, but conventional and dual-energy CT often struggle to distinguish HA from iodinated contrast because of overlapping attenuation, noise, and beam-hardening artifacts. Spectral photon-counting CT (SPCCT) offers improved energy resolution and spatial fidelity, yet most deep-learning approaches in spectral CT focus on continuous density regression or anatomical segmentation rather than direct voxel-wise material labeling. We developed SPFF–UNet, a spectral-preserving 3D segmentation model for direct classification of HA and iodine concentrations from five-bin SPCCT volumes without material-decomposition preprocessing. A cylindrical phantom containing twelve materials was scanned at 0.1 mm isotropic resolution, including five HA concentrations, three iodine concentrations, three soft-tissue equivalents, and water. SPFF–UNet integrates spectral squeeze-excitation, EnergyFiLM, and FourierGate to preserve and exploit multi-energy information throughout the network. The model was trained for thirteen-class voxel-wise segmentation and compared with five established 3D architectures under matched training conditions. SPFF–UNet achieved the best macro-averaged performance on a held-out phantom scan (Dice 0.72 ± 0.01, IoU 0.59 ± 0.01, sensitivity 0.73 ± 0.01, precision 0.71 ± 0.01), outperforming the strongest comparator, ResUNet++ (Dice 0.66 ± 0.02, IoU 0.46 ± 0.02, sensitivity 0.67 ± 0.02, precision 0.61 ± 0.03). Performance gains were concentrated in mid/low-contrast HA and low-concentration iodine, with reduced slice-wise variability and fewer HA–iodine misclassifications. These results suggest that preserving spectral information and applying targeted spectral modulation can improve concentration-aware voxel classification from SPCCT. This phantom-based proof-of-concept provides a basis for future in vivo validation.
- 9 April 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (4) , e0346825
Open AccessVoxel-wise deep learning segmentation of hydroxyapatite and iodine in spectral photon-counting CT: A quantitative phantom study
Accurate non-invasive identification of hydroxyapatite (HA) deposits is important for diagnosing calcific musculoskeletal disease and quantifying vascular calcification, but conventional and dual-energy CT often struggle to distinguish HA from iodinated contrast because of overlapping attenuation, noise, and beam-hardening artifacts. Spectral photon-counting CT (SPCCT) offers improved energy resolution and spatial fidelity, yet most deep-learning approaches in spectral CT focus on continuous density regression or anatomical segmentation rather than direct voxel-wise material labeling. We developed SPFF–UNet, a spectral-preserving 3D segmentation model for direct classification of HA and iodine concentrations from five-bin SPCCT volumes without material-decomposition preprocessing. A cylindrical phantom containing twelve materials was scanned at 0.1 mm isotropic resolution, including five HA concentrations, three iodine concentrations, three soft-tissue equivalents, and water. SPFF–UNet integrates spectral squeeze-excitation, EnergyFiLM, and FourierGate to preserve and exploit multi-energy information throughout the network. The model was trained for thirteen-class voxel-wise segmentation and compared with five established 3D architectures under matched training conditions. SPFF–UNet achieved the best macro-averaged performance on a held-out phantom scan (Dice 0.72 ± 0.01, IoU 0.59 ± 0.01, sensitivity 0.73 ± 0.01, precision 0.71 ± 0.01), outperforming the strongest comparator, ResUNet++ (Dice 0.66 ± 0.02, IoU 0.46 ± 0.02, sensitivity 0.67 ± 0.02, precision 0.61 ± 0.03). Performance gains were concentrated in mid/low-contrast HA and low-concentration iodine, with reduced slice-wise variability and fewer HA–iodine misclassifications. These results suggest that preserving spectral information and applying targeted spectral modulation can improve concentration-aware voxel classification from SPCCT. This phantom-based proof-of-concept provides a basis for future in vivo validation.
- Open Access
- 26 February 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 120
SuperAMUS-GAN: An image-domain based supervised adversarial multi-scale U-Net synthesis model for CT metal artefacts reduction
- 26 February 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 120
Open AccessSuperAMUS-GAN: An image-domain based supervised adversarial multi-scale U-Net synthesis model for CT metal artefacts reduction
- Open Access
- 3 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 205182-205196
ISMDNet: Multi-Material Decomposition Using Deep Learning and Inverse Transform Sampling in Spectral Photon Counting CT
Spectral Photon-Counting Computed Tomography (SPCCT) is a novel imaging technique that uses photon-counting detectors to acquire images across multiple X-ray energy windows. This energy discrimination enables material decomposition (MD) using the X-ray attenuation properties of various materials. In this study, we develop a novel deep learning (DL) framework for MD in SPCCT and compare its performance with recently developed MD methods. Our approach includes three variants of an encoder-decoder network: ISMDNet (Inverse Sampling Material Decomposition Network) with dual-residual blocks, ISMDNet-AT, which incorporates a channel-wise attention mechanism, and ISMDNet-TR, which integrates multiple transformer layers. We developed a unique synthetic image generation method using inverse transform sampling to address the scarcity of spectral CT datasets and the labor-intensive nature of ground-truth annotation. Synthetic images were used to train deep learning (DL) models, which were subsequently validated and tested on real SPCCT images. We conducted two studies, one involving various known materials in a phantom and the other using a biological tissue phantom. The performance of all approaches was evaluated using the root mean square error (RMSE) and the structural similarity index measure (SSIM) for MD quality, along with precision and the F1 score to assess the effectiveness of material identification. We compared our DL models’ performance with the state-of-the-art MD methods, including direct inversion (DI), generalized dictionary learning-based image domain (GDLIMD), MARS-MD, U-Net, and InceptNet. Our MD techniques consistently outperform the other MD methods.
- 3 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 205182-205196
Open AccessISMDNet: Multi-Material Decomposition Using Deep Learning and Inverse Transform Sampling in Spectral Photon Counting CT
Spectral Photon-Counting Computed Tomography (SPCCT) is a novel imaging technique that uses photon-counting detectors to acquire images across multiple X-ray energy windows. This energy discrimination enables material decomposition (MD) using the X-ray attenuation properties of various materials. In this study, we develop a novel deep learning (DL) framework for MD in SPCCT and compare its performance with recently developed MD methods. Our approach includes three variants of an encoder-decoder network: ISMDNet (Inverse Sampling Material Decomposition Network) with dual-residual blocks, ISMDNet-AT, which incorporates a channel-wise attention mechanism, and ISMDNet-TR, which integrates multiple transformer layers. We developed a unique synthetic image generation method using inverse transform sampling to address the scarcity of spectral CT datasets and the labor-intensive nature of ground-truth annotation. Synthetic images were used to train deep learning (DL) models, which were subsequently validated and tested on real SPCCT images. We conducted two studies, one involving various known materials in a phantom and the other using a biological tissue phantom. The performance of all approaches was evaluated using the root mean square error (RMSE) and the structural similarity index measure (SSIM) for MD quality, along with precision and the F1 score to assess the effectiveness of material identification. We compared our DL models’ performance with the state-of-the-art MD methods, including direct inversion (DI), generalized dictionary learning-based image domain (GDLIMD), MARS-MD, U-Net, and InceptNet. Our MD techniques consistently outperform the other MD methods.
- Open Access
- 1 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. PP, 1
Advancements in Material Decomposition Techniques for Spectral CT: A Comparative Analysis of Traditional and AI-driven Methods
Material Decomposition (MD) in Computed Tomography (CT) imaging is undergoing a significant transformation as it shifts towards the integration of Machine Learning (ML) and Artificial Intelligence (AI) frameworks. The combination of spectral (multi-energy) CT and AI-based MD techniques have the potential to enhance the management of MD-related tasks in terms of diagnostic efficiency, accuracy, and early diagnosis at high spatial resolution. Despite the challenges posed by patient exposure to ionizing radiation, image noise, and image distortions caused by artifacts, AI-based medical diagnostic techniques show great promise for the development of intelligent MD systems. In this article, we provide a comprehensive and categorized review and analysis of traditional MD and modern AI-based MD techniques for both the image and projection domains. We highlight each approach’s distinctive features, advantages, and disadvantages, as well as the intrinsic features and critical attributes of the AI-based MD techniques. Finally, we conclude by presenting key observations and laying a strong foundation for future research to design and implement AI-based MD techniques. Our aim is to provide a comprehensive understanding of the current state of the field and to encourage further exploration of this exciting and rapidly evolving area.
- 1 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. PP, 1
Open AccessAdvancements in Material Decomposition Techniques for Spectral CT: A Comparative Analysis of Traditional and AI-driven Methods
Material Decomposition (MD) in Computed Tomography (CT) imaging is undergoing a significant transformation as it shifts towards the integration of Machine Learning (ML) and Artificial Intelligence (AI) frameworks. The combination of spectral (multi-energy) CT and AI-based MD techniques have the potential to enhance the management of MD-related tasks in terms of diagnostic efficiency, accuracy, and early diagnosis at high spatial resolution. Despite the challenges posed by patient exposure to ionizing radiation, image noise, and image distortions caused by artifacts, AI-based medical diagnostic techniques show great promise for the development of intelligent MD systems. In this article, we provide a comprehensive and categorized review and analysis of traditional MD and modern AI-based MD techniques for both the image and projection domains. We highlight each approach’s distinctive features, advantages, and disadvantages, as well as the intrinsic features and critical attributes of the AI-based MD techniques. Finally, we conclude by presenting key observations and laying a strong foundation for future research to design and implement AI-based MD techniques. Our aim is to provide a comprehensive understanding of the current state of the field and to encourage further exploration of this exciting and rapidly evolving area.
- 1 September 2025
- Published by Springer Nature
- p. 421-446
Applications of Photon-Counting Detector-Based Micro-Computed Tomography in Preclinical Bioimaging
- 1 September 2025
- Published by Springer Nature
- p. 421-446
Applications of Photon-Counting Detector-Based Micro-Computed Tomography in Preclinical Bioimaging
- Open Access
- 23 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 6397-6412
3D-Printed Anthropomorphic Phantom Framework for Spectral Photon-Counting CT: A Breast Phantom Application
Anthropomorphic phantoms are critical in computed tomography (CT) imaging, simulating human anatomy for image quality and dosimetry evaluation. Traditional phantoms, however, often fail to accurately replicate complex tissue patterns, particularly for advanced technologies like spectral photon-counting CT (SPCCT). This study introduces a framework for creating 3D-printed anthropomorphic phantoms optimized for SPCCT, beginning with a breast phantom. A grid search optimization method was used to generate an optimal image acquisition protocol, capable of distinguishing between adipose, fibroglandular, skin, and carcinoma tissues. Using the MARS Microlab 5×120 SPCCT system, it was found that a tube voltage of 80 kV and narrow energy bins 7-27 keV, 27-32 keV, 32-37 keV, 37-42 keV, and 42-80 keV, offered superior results. Various photopolymerizable resins and thermoplastic filaments were tested as tissue-mimicking materials (TMMs), comparing their linear attenuation coefficients with those of the tissues and reference TMMs. The breast phantom was created by segmenting an MRI image from the Duke Breast Cancer MRI dataset into two models: one for skin, fibroglandular, and carcinoma tissues, 3D-printed with e-PLA resin, and another for adipose tissue, replicated using paraffin wax. Multi-energy images of the phantom were then evaluated using both narrow and wide energy bins for validation. While this study focused on a breast phantom, the framework can be applied to create various anthropomorphic phantoms, enhancing SPCCT imaging and potentially improving diagnostic accuracy and patient outcomes.
- 23 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 6397-6412
Open Access3D-Printed Anthropomorphic Phantom Framework for Spectral Photon-Counting CT: A Breast Phantom Application
Anthropomorphic phantoms are critical in computed tomography (CT) imaging, simulating human anatomy for image quality and dosimetry evaluation. Traditional phantoms, however, often fail to accurately replicate complex tissue patterns, particularly for advanced technologies like spectral photon-counting CT (SPCCT). This study introduces a framework for creating 3D-printed anthropomorphic phantoms optimized for SPCCT, beginning with a breast phantom. A grid search optimization method was used to generate an optimal image acquisition protocol, capable of distinguishing between adipose, fibroglandular, skin, and carcinoma tissues. Using the MARS Microlab 5×120 SPCCT system, it was found that a tube voltage of 80 kV and narrow energy bins 7-27 keV, 27-32 keV, 32-37 keV, 37-42 keV, and 42-80 keV, offered superior results. Various photopolymerizable resins and thermoplastic filaments were tested as tissue-mimicking materials (TMMs), comparing their linear attenuation coefficients with those of the tissues and reference TMMs. The breast phantom was created by segmenting an MRI image from the Duke Breast Cancer MRI dataset into two models: one for skin, fibroglandular, and carcinoma tissues, 3D-printed with e-PLA resin, and another for adipose tissue, replicated using paraffin wax. Multi-energy images of the phantom were then evaluated using both narrow and wide energy bins for validation. While this study focused on a breast phantom, the framework can be applied to create various anthropomorphic phantoms, enhancing SPCCT imaging and potentially improving diagnostic accuracy and patient outcomes.
- Open Access
- 13 September 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (9) , e0308658
Assessment of material identification and quantification in the presence of metals using spectral photon counting CT
Spectral Photon Counting Computed Tomography (SPCCT), a ground-breaking development in CT technology, has immense potential to address the persistent problem of metal artefacts in CT images. This study aims to evaluate the potential of Mars photon-counting CT technology in reducing metal artefacts. It focuses on identifying and quantifying clinically significant materials in the presence of metal objects. A multi-material phantom was used, containing inserts of varying concentrations of hydroxyapatite (a mineral present in teeth, bones, and calcified plaque), iodine (used as a contrast agent), CT water (to mimic soft tissue), and adipose (as a fat substitute). Three sets of scans were acquired: with aluminium, with stainless steel, and without a metal insert as a reference dataset. Data acquisition was performed using a Mars SPCCT scanner (Microlab 5×120); operated at 118 kVp and 80 μA. The images were subsequently reconstructed into five energy bins: 7-40, 40-50, 50-60, 60-79, and 79-118 keV. Evaluation metrics including signal-to-noise ratio (SNR), linearity of attenuation profiles, root mean square error (RMSE), and area under the curve (AUC) were employed to assess the energy and material-density images with and without metal inserts. Results show decreased metal artefacts and a better signal-to-noise ratio (up to 25%) with increased energy bins as compared to reference data. The attenuation profile also demonstrated high linearity (R2 >0.95) and lower RMSE across all material concentrations, even in the presence of aluminium and steel. Material identification accuracy for iodine and hydroxyapatite (with and without metal inserts) remained consistent, minimally impacting AUC values. For demonstration purposes, the biological sample was also scanned with the stainless steel volar implant and cortical bone screw, and the images were objectively assessed to indicate the potential effectiveness of SPCCT in replicating real-world clinical scenarios.
- 13 September 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (9) , e0308658
Open AccessAssessment of material identification and quantification in the presence of metals using spectral photon counting CT
Spectral Photon Counting Computed Tomography (SPCCT), a ground-breaking development in CT technology, has immense potential to address the persistent problem of metal artefacts in CT images. This study aims to evaluate the potential of Mars photon-counting CT technology in reducing metal artefacts. It focuses on identifying and quantifying clinically significant materials in the presence of metal objects. A multi-material phantom was used, containing inserts of varying concentrations of hydroxyapatite (a mineral present in teeth, bones, and calcified plaque), iodine (used as a contrast agent), CT water (to mimic soft tissue), and adipose (as a fat substitute). Three sets of scans were acquired: with aluminium, with stainless steel, and without a metal insert as a reference dataset. Data acquisition was performed using a Mars SPCCT scanner (Microlab 5×120); operated at 118 kVp and 80 μA. The images were subsequently reconstructed into five energy bins: 7-40, 40-50, 50-60, 60-79, and 79-118 keV. Evaluation metrics including signal-to-noise ratio (SNR), linearity of attenuation profiles, root mean square error (RMSE), and area under the curve (AUC) were employed to assess the energy and material-density images with and without metal inserts. Results show decreased metal artefacts and a better signal-to-noise ratio (up to 25%) with increased energy bins as compared to reference data. The attenuation profile also demonstrated high linearity (R2 >0.95) and lower RMSE across all material concentrations, even in the presence of aluminium and steel. Material identification accuracy for iodine and hydroxyapatite (with and without metal inserts) remained consistent, minimally impacting AUC values. For demonstration purposes, the biological sample was also scanned with the stainless steel volar implant and cortical bone screw, and the images were objectively assessed to indicate the potential effectiveness of SPCCT in replicating real-world clinical scenarios.
- Open Access
- 7 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 109735-109749
Development of Residual Dense U-Net (RDU-Net)-Based Metal Artefacts Reduction Technique Using Spectral Photon Counting CT
Metal induced artefacts in computed tomography (CT) images are primarily caused by beam hardening, scatter effects, and photon starvation. These artefacts impede the characterization of fine anatomical structures and compromise the diagnostic value of the CT images. We aim to develop an innovative machine learning-based technique called residual dense U-Net (RDU-Net), specifically for spectral photon-counting CT (SPCCT), to mitigate metal artefacts across all energy bins. The proposed model was quantitatively evaluated, with and without the metal artefact reduction (MAR) algorithm, using line profiles, histogram analysis, signal-to-noise ratio (SNR), root mean squared error (RMSE), and structural similarity index measure (SSIM). The results show significant improvements with the average SNR increasing from 3.37 to 17.40 across the five energy bins after the application of the MAR algorithm. The average RMSE decreased from 0.016 to 0.001, and the average SSIM increased by 34.9%. The study also evaluated material density images of hydroxyapatite (HA) and iodine, with and without the MAR algorithm, using the receiver operating characteristic (ROC) paradigm. The results show improved accuracy in the material identification for HA (86% to 91%) and iodine (84% to 93%) after MAR. Overall, the evaluation of the model show promising results and the potential to significantly decrease the metal artefacts in all the parameters used in the energy analysis at p < 0.0001, while preserving the attenuation profile of SPCCT images.
- 7 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 109735-109749
Open AccessDevelopment of Residual Dense U-Net (RDU-Net)-Based Metal Artefacts Reduction Technique Using Spectral Photon Counting CT
Metal induced artefacts in computed tomography (CT) images are primarily caused by beam hardening, scatter effects, and photon starvation. These artefacts impede the characterization of fine anatomical structures and compromise the diagnostic value of the CT images. We aim to develop an innovative machine learning-based technique called residual dense U-Net (RDU-Net), specifically for spectral photon-counting CT (SPCCT), to mitigate metal artefacts across all energy bins. The proposed model was quantitatively evaluated, with and without the metal artefact reduction (MAR) algorithm, using line profiles, histogram analysis, signal-to-noise ratio (SNR), root mean squared error (RMSE), and structural similarity index measure (SSIM). The results show significant improvements with the average SNR increasing from 3.37 to 17.40 across the five energy bins after the application of the MAR algorithm. The average RMSE decreased from 0.016 to 0.001, and the average SSIM increased by 34.9%. The study also evaluated material density images of hydroxyapatite (HA) and iodine, with and without the MAR algorithm, using the receiver operating characteristic (ROC) paradigm. The results show improved accuracy in the material identification for HA (86% to 91%) and iodine (84% to 93%) after MAR. Overall, the evaluation of the model show promising results and the potential to significantly decrease the metal artefacts in all the parameters used in the energy analysis at p < 0.0001, while preserving the attenuation profile of SPCCT images.
- 16 March 2024
- Published by Elsevier in Physica Medica
- Vol. 120, 103326
Gold nanoparticles spectral CT imaging and limit of detectability in a new materials contrast-detail phantom
- 16 March 2024
- Published by Elsevier in Physica Medica
- Vol. 120, 103326
Gold nanoparticles spectral CT imaging and limit of detectability in a new materials contrast-detail phantom
- 31 January 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 11 (9) , 1916-1928
LHRH conjugated gold nanoparticles assisted efficient ovarian cancer targeting evaluated via spectral photon-counting CT imaging: a proof-of-concept research
Emerging multifunctional nanoparticulate formulations take advantage of nano-meter scale size and surface chemistry to work as a therapeutic delivery agent and a diagnostic tool for non-invasive real-time monitoring using imaging technologies. Here, we evaluate the selective uptake of 18 nm and 80 nm sized gold nanoparticles (AuNPs) by SKOV3 (4 times higher) ovarian cancer (OC) cells (compared to OVCAR5) in vitro, quantified by inductively coupled plasma (ICP) and MARS spectral photon-counting CT imaging (MARS SPCCT). Based on in vitro analysis, pristine AuNPs (18 nm) and surface modified AuNPs (18 nm) were chosen as a contrast agent for MARS SPCCT. The chemical analysis by FTIR spectroscopy confirmed the luteinizing hormone-releasing hormone (LHRH) conjugation to the AuNPs surface. For the first time, LHRH conjugated AuNPs were used for in vitro and selective in vivo OC targeting. The ICP-MS analysis confirmed preferential uptake of LHRH modified AuNPs by organs residing in the abdominal cavity with OC nodules (pancreas: 0.46 ng mg−1, mesentery: 0.89 ng mg−1, ovary: 1.43 ng mg−1, and abdominal wall: 2.12 ng mg−1) whereas the MARS SPCCT analysis suggested scattered accumulation of metal around the abdominal cavity. Therefore, the study showed the exciting potential of LHRH conjugated AuNPs to target ovarian cancer and also as a potential contrast agent for novel SPCCT imaging technology.
- 31 January 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 11 (9) , 1916-1928
LHRH conjugated gold nanoparticles assisted efficient ovarian cancer targeting evaluated via spectral photon-counting CT imaging: a proof-of-concept research
Emerging multifunctional nanoparticulate formulations take advantage of nano-meter scale size and surface chemistry to work as a therapeutic delivery agent and a diagnostic tool for non-invasive real-time monitoring using imaging technologies. Here, we evaluate the selective uptake of 18 nm and 80 nm sized gold nanoparticles (AuNPs) by SKOV3 (4 times higher) ovarian cancer (OC) cells (compared to OVCAR5) in vitro, quantified by inductively coupled plasma (ICP) and MARS spectral photon-counting CT imaging (MARS SPCCT). Based on in vitro analysis, pristine AuNPs (18 nm) and surface modified AuNPs (18 nm) were chosen as a contrast agent for MARS SPCCT. The chemical analysis by FTIR spectroscopy confirmed the luteinizing hormone-releasing hormone (LHRH) conjugation to the AuNPs surface. For the first time, LHRH conjugated AuNPs were used for in vitro and selective in vivo OC targeting. The ICP-MS analysis confirmed preferential uptake of LHRH modified AuNPs by organs residing in the abdominal cavity with OC nodules (pancreas: 0.46 ng mg−1, mesentery: 0.89 ng mg−1, ovary: 1.43 ng mg−1, and abdominal wall: 2.12 ng mg−1) whereas the MARS SPCCT analysis suggested scattered accumulation of metal around the abdominal cavity. Therefore, the study showed the exciting potential of LHRH conjugated AuNPs to target ovarian cancer and also as a potential contrast agent for novel SPCCT imaging technology.