Shigeru Tada has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Dielectrophoretic Separation of Human Normal and Tumor Cells

    by Shigeru Tada, Aoi Nagasaka, Yoshinori Seki

    In this study, we proposed and evaluated a new dielectrophoresis (DEP)-based device for the high-throughput, non-invasive separation of cells with similar physical properties. Although DEP is an established technology for separating biological particles based on their dielectric properties, the accurate separation of populations of similar cell types—such as normal cells and cancer cells of the same species—remains a significant technical challenge. In this study, separation experiments using a prototype device were conducted with normal (MCF10A) and tumor (MDA-MB-231) human mammary cells. The experiments systematically analyzed the effects of three key parameters—A.C. frequency (f), flow rate (Q), and solution conductivity (σf)—on the cell separation ratio (Φ). The experimental results identified optimal operating conditions at f = 57.6 kHz, Q = 5.0 mL/h, and σf = 40 mS/m, achieving a maximum separation ratio of Φ = 72.1%. These findings demonstrate that the potential of this device to perform high-speed processing without the need for fluorescent labeling or invasive pretreatment. This study provides a fundamental framework for optimizing DEP parameters and outlines a pathway toward more efficient clinical applications and the isolation of rare cell populations.

  • Open Access

    An Investigation of the Heating Performance of a Groundwater-Based Air Conditioning System for an Agricultural Greenhouse

    by Koji Toriyama, Kyosuke Wakishima, Ichiei Kuranuki, Shigeru Tada, Shumpei Funatani

    Food shortages due to the decreasing arable land area, which is a consequence of the increasing global population, have brought greater attention to greenhouses. However, the cost of air conditioning in greenhouses is high. Therefore, in this study, the heating performance of a low-running-cost air conditioning system using groundwater was evaluated in winter in an agricultural greenhouse. The system consisted of a temperature control room in an agricultural greenhouse and a groundwater recirculation system. The pumped groundwater was passed through a polytube heat exchanger panel and stored in a recirculation tank. The stored water circulated back to the heat exchanger to create a water recirculation system. When operated with only a single 250 L recirculation tank, the temperature in the temperature control room was maintained at 4.9–19.4 °C, even when the maximum and minimum outdoor air temperatures were 12.6 and −2.3 °C, respectively. To achieve a higher minimum temperature in the temperature control room, a method was developed to enable the system to switch from the recirculating water to flowing groundwater when the recirculating water temperature fell below the groundwater temperature. Consequently, the minimum temperature in the temperature control room could be maintained at 8.0 °C. In an experiment in which the capacity of the recirculation tank was tripled (750 L), the minimum temperature was maintained at 7.9 °C, which is a stable temperature for cucumber cultivation. These results indicate that the heating capacity of the proposed system is equivalent to that of ACCFHES (An aquifer coupled cavity flow heat exchanger system) and other heating systems for winter heating. Therefore, this proposed method makes it possible to cultivate plants that grow in a climate similar to that of cucumbers at a low running cost. The amount of heating capacity that could be extracted simply by circulating groundwater was also revealed.


  • Open Access

    Modeling of Electric Field and Dielectrophoretic Force in a Parallel-Plate Cell Separation Device with an Electrode Lid and Analytical Formulation Using Fourier Series

    by Daiki Nishikawa, Yoshinori Seki, Shigeru Tada

    Dielectrophoresis (DEP) cell separation technology is an effective means of separating target cells which are only marginally present in a wide variety of cells. To develop highly efficient cell separation devices, detailed analysis of the nonuniform electric field’s intensity distribution within the device is needed, as it affects separation performance. Here we analytically expressed the distributions of the electric field and DEP force in a parallel-plate cell separation DEP device by employing electrostatic analysis through the Fourier series method. The solution was approximated by extrapolating a novel approximate equation as a boundary condition for the potential between adjacent fingers of interdigitated electrodes and changing the underlying differential equation into a solvable form. The distributions of the potential and electric fields obtained by the analytical solution were compared with those from numerical simulations using finite element method software to verify their accuracy. As a result, it was found that the two agreed well, and the analytical solution was obtained with good accuracy. Three-dimensional fluorescence imaging analysis was performed using live non-tumorigenic human mammary (MCF10A) cells. The distribution of cell clusters adsorbed on the interdigitated electrodes was compared with the analytically obtained distribution of the DEP force, and the mechanism underlying cell adsorption on the electrode surface was discussed. Furthermore, parametric analysis using the width and spacing of these electrodes as variables revealed that spacing is crucial for determining DEP force. The results suggested that for cell separation devices using interdigitated electrodes, optimization by adjusting electrode spacing could significantly enhance device performance.


  • Open Access

    Analysis of Cell Dielectrophoretic Properties Using Isomotive Creek-Gap Electrode Device

    by Shigeru Tada, Noriko Sato

    Various types of dielectrophoresis (DEP) cell separation devices using AC electric fields have been proposed and developed. However, its capability is still limited by a lack of quantitative characterization of the relationship between frequency and force. In the present study, this limitation was addressed by developing a method capable of fast and accurate quantification of the dielectric properties of biological cells. A newly designed Creek-gap electrode device can induce constant DEP forces on cells, realizing the isomotive movement of cells suitable for DEP analysis. The real number part of the Clausius–Mossotti (CM) factor of cells, Re(β), was obtained by simple cell velocimetry together with the numerical three-dimensional (3D) electric field analysis. Human mammary cells, MCF10A, and its cancer cells, MCF7 and MDAMB231, were used as model cells to evaluate the capability of the proposed device. The estimation of Re(β) using the Creek-gap electrode device showed good agreement with previously reported values. Furthermore, the thermal behavior of the Creek-gap electrode device, which is crucial to cell viability, was investigated by adopting micro laser-induced fluorescence (LIF) thermometry using Rhodamine B. The temperature rise in the device was found to be approximately several degrees Celsius at most. The results demonstrate that the proposed method could be a powerful tool for fast and accurate noninvasive measurement of the DEP spectrum and the determination of the dielectric properties of biological cells.


  • Open Access

    Development of a DualEmission Laser-Induced Fluorescence (DELIF) Method for Long-Term Temperature Measurements

    by Koji Toriyama, Shumpei Funatani, Shigeru Tada

    The fluorescence intensity of fluorescent dyes typically employed in the dual-emission laser-induced fluorescence (DELIF) method gradually degrades as the excitation time increases, and the degradation rate depends on the type of fluorescent dye used. Therefore, the DELIF method is unsuitable for long-term temperature measurements. In this study, we focused on the fluorescence intensity ratio of a single fluorescent dye at two fluorescence wavelengths and developed a DELIF method for long-term temperature measurements based on this ratio. The fluorescence intensity characteristics of Fluorescein disodium and Rhodamine B, which are typically used in the DELIF method, in the temperature range of 10–60 °C were comprehensively investigated using two high-speed monochrome complementary metal-oxide semiconductor cameras and narrow bandpass filters. Interestingly, the ratio of the fluorescence intensity of each fluorescent dye at the peak emission wavelength of the fluorescence spectrum, λ, to the fluorescence intensity at wavelengths very close to the peak wavelength (λ ± 10 nm) was highly sensitive to temperature variations but not excitation time. Particularly, when Rhodamine B was used, the selection of the fluorescence intensity ratios at a wavelength combination of 589 and 600 nm enabled highly accurate temperature measurements with a temperature resolution of ≤0.042 °C. Moreover, the fluorescence intensity ratio varied negligibly throughout the excitation time of 180 min, with a measurement uncertainty (95% confidence interval) of 0.045 °C at 20 °C. The results demonstrate that the proposed DELIF method enables highly accurate long-term temperature measurements.


  • Open Access

    Experimental and Numerical Studies of the Temperature Field in a Dielectrophoretic Cell Separation Device Subject to Joule Heating

    by Yoshinori Seki, Shigeru Tada

    Technologies for rapid and high-throughput separation of rare cells from large populations of other types of cells have recently attracted much attention in the field of bioengineering. Among the various cell separation technologies proposed in the past, dielectrophoresis has shown particular promise because of its preciseness of manipulation and noninvasiveness to cells. However, one drawback of dielectrophoresis devices is that their application of high voltage generates Joule heat that exposes the cells within the device to high temperatures. To further explore this problem, this study investigated the temperature field in a previously developed cell separation device in detail. The temperature rise at the bottom of the microfluidic channel in the device was measured using a micro-LIF method. Moreover, the thermofluidic behavior of the cell separation device was numerically investigated by adopting a heat generation model that takes the electric-field-dependent heat generation term into account in the energy equation. Under the operating conditions of the previously developed cell separation device, the experimentally obtained temperature rise in the device was approximately 20 °C, and the numerical simulation results generally agreed well. Next, parametric calculations were performed with changes in the flow rate of the cell sample solution and the solution conductivity, and a temperature increase of more than 40 °C was predicted. The results demonstrated that an increase in temperature within the cell separation device may have a significant impact on the physiological functions of the cells, depending on the operating conditions of the device.


  • Open Access

    Experimental and Numerical Studies of the Temperature Field in a Dielectrophoretic Cell Separation Device Subject to Joule Heating

    by Yoshinori Seki, Shigeru Tada

    Technologies for rapid and high-throughput separation of rare cells from large populations of other types of cells have recently attracted much attention in the field of bioengineering. Among the various cell separation technologies proposed in the past, dielectrophoresis has shown particular promise because of its preciseness of manipulation and noninvasiveness to cells. However, one drawback of dielectrophoresis devices is that their application of high-voltage generates Joule heat that exposes the cells within the device to high temperature. To further explore this problem, this study investigated the temperature field in the previously developed cell separation device in detail. The temperature rise at the bottom of the microfluidic channel in the device was measured using a micro-LIF method. Moreover, the thermofluidic behavior of the cell separation device was numerically investigated by adopting a heat generation model that takes the electric-field-dependent heat generation term into account in the energy equation. Under the operating conditions of the previously developed cell separation device, the experimentally obtained temperature rise in the device was approximately 20 ℃, and the numerical simulation results generally agreed well. Next, parametric calculations were performed with changes in the flow rate of the cell sample solution and the solution conductivity, and a temperature increase of more than 40 ℃ was predicted. The results demonstrated that an increase in temperature within the cell separation device may have a significant impact on the physiological functions of the cells, depending on the operating conditions of the device.


  • Open Access

    Modeling of Electric Field and Dielectrophoretic Force in a Parallel-plate Cell-separation Device with an Electrode Lid and Analytical Formulation Using Fourier Series

    by Daiki Nishikawa, Yoshinori Seki, Shigeru Tada

    Dielectrophoresis (DEP) cell-separation technology is an effective means of separating rare cells. To develop highly efficient cell-separation devices, detailed analysis of the nonuniform electric field’s intensity distribution within the device is needed, as it affects separation performance. Here we analytically expressed the distributions of the electric field and DEP force in a parallel-plate cell-separation DEP device by employing electrostatic analysis through the Fourier series method. The solution was approximated by extrapolating a novel approximate equation as a boundary condition for the potential between adjacent fingers of interdigitated electrodes and changed the underlying differential equation into a solvable form. The distributions of the potential and electric fields obtained by the analytical solution were compared with those from numerical simulations using finite element method software to verify their accuracy. The results showed excellent agreement. Three-dimensional fluorescence imaging analysis used live non-tumorigenic human mammary (MCF10A) cells. The distribution of cell clusters adsorbed on the interdigitated electrodes was compared with the analytically obtained distribution of the DEP force, and the mechanism underlying cell adsorption on the electrode surface was discussed. Furthermore, parametric analysis using the width and spacing of these electrodes as variables revealed that spacing is crucial for determining DEP force. The results showed that, by optimizing cell-separation devices using interdigitated electrodes, adjusting electrode spacing significantly enhances device performance.


  • Proposal and performance evaluation of a new parallel plate continuous cell separation device using dielectrophoresis

    by Yoshinori Seki, Aoi Nagasaka, Tsukushi Gondo, Shigeru Tada

    Along with the rapid development of cellular biological research in recent years, there has been an urgent need for a high‐speed, high‐precision method of separating target cells from a highly heterogeneous cell population. Among the various cell separation technologies proposed so far, dielectrophoresis (DEP)‐based approaches have shown particular promise because they are noninvasive to cells. We have developed a new DEP‐based device to separate large numbers of live and dead cells of the human mammary cell line MCF10A. In this study, we validated the separation performance of this device. The results showed the successful separation of a higher percentage of cells than in previous studies, with a separation efficiency higher than 90%. In the past, there have been no confirmed cases in which a separation rate of over 90% and high‐speed processing of a large number of cells were simultaneously achieved. It was shown that the proposed device can process large numbers of cells at high speed and with high accuracy.