JHJoong-Won Ha

Joong-Won Ha

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Joong-Won Ha has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of Pes Anserinus Release on Postoperative Pain and Medial Stability in Medial Opening Wedge High Tibial Osteotomy

    by Han-Kook Yoon, Hyun-Cheol Oh, Joong-Won Ha, Youngwoo Lee, Sang-Hoon Park

    Background and Objectives: Medial opening wedge high tibial osteotomy (OWHTO) requires careful management of medial soft-tissue tension to achieve effective decompression and maintain knee stability. While superficial medial collateral ligament (sMCL) release is commonly performed, the role of pes anserinus release remains unclear. This study investigated the effect of pes anserinus release on postoperative pain, clinical outcomes, and medial stability in patients undergoing OWHTO. Materials and Methods: A retrospective analysis was performed on 80 knees (80 patients) that underwent OWHTO between 2012 and 2017. Patients were divided into two groups: Group A (n = 38, sMCL release only) and Group B (n = 42, sMCL + pes anserinus release). Immediate postoperative pain was assessed using visual analog scale (VAS) scores and rescue analgesic use. Clinical outcomes were evaluated with Knee Society Scores (KSSs). Radiographic medial joint opening (MJO) was measured on valgus stress radiographs preoperatively and at one year postoperatively. Results: Group B demonstrated significantly lower VAS pain scores at postoperative days (PODs) 1, 3, 5, 7, and 14 (p < 0.05) and required fewer rescue analgesics (5.5 ± 2.1 vs. 7.6 ± 3.7; p < 0.05). Both groups achieved comparable KSS improvement and radiographic correction (postoperative mechanical femorotibial angle: 2.1° valgus vs. 2.5° valgus). No significant intergroup or intragroup differences were observed in MJO at one-year follow-up (p > 0.05). Conclusions: Combined release of the superficial medial collateral ligament and pes anserinus during medial opening wedge high tibial osteotomy significantly reduces early postoperative pain and improves short-term functional recovery without compromising medial stability or alignment correction, although no significant long-term differences in functional outcomes or radiographic alignment were observed.

  • Open Access

    Comparing Outcomes between Cage Alone and Plate Fixation in Single-Level Anterior Cervical Fusion: A Retrospective Clinical Series

    by Jae-Won Shin, Han-Bin Jin, Yung Park, Joong-Won Ha, Hak-Sun Kim, Kyung-Soo Suk, Sung-Hwan Moon, Si-Young Park, Byung-Ho Lee, Ji-Won Kwon, et al.

    Shin JW, et al. Clin Orthop Surg. 2025 Feb;17:e25. https://doi.org/10.4055/cios24036


  • Open Access

    Impact of Distal Fusion Level on Sacroiliac Joint Degenerative Change Following Adolescent Idiopathic Scoliosis Surgery

    by Sang-Ho Kim, Jae-Won Shin, Seong-Hwan Moon, Kyung-Soo Suk, Si-Young Park, Byung-Ho Lee, Ji-Won Kwon, Joong Won Ha, Yung Park, Hak-Sun Kim

    Kim SH, et al. Yonsei Med J. 2024 Oct;65:e79. https://doi.org/10.3349/ymj.2023.0634


  • Open Access

    Risk Factors and Characteristics of In-Hospital Falls After Spine Surgery

    by Jae-Won Shin, Heon Jung Park, Yung Park, Joong-Won Ha, Jung Hwa Hong, Hak-Sun Kim, Kyung-Soo Suk, Seong-Hwan Moon, Si-Young Park, Byung-Ho Lee, et al.

    Background: Falls after orthopaedic surgery can cause serious injuries, which lengthen hospital stays and increase medical expenses. This has prompted hospitals to implement various fall-prevention protocols. The aims of this study were to determine the incidence of in-hospital falls after spine surgery, to analyze the overall risk factors, to discern factors that have a major influence on falls, and to evaluate the effectiveness of the fall-prevention protocol that we implemented. Methods: This was a retrospective, single-center study including patients who underwent spine surgery from January 2011 to November 2021 at the National Health Insurance Service Ilsan Hospital (NHISIH) in Goyang, Republic of Korea. Reported falls among these patients were examined. Patient demographics; surgery type, date, and diagnosis; and fall date and time were evaluated. Results: Overall, 5,317 spine surgeries were performed, and 128 in-hospital falls were reported (overall incidence: 2.31%). From the multivariable analyses, older age and American Society of Anesthesiologists (ASA) score were identified as independent risk factors for in-hospital patient falls (multivariable adjusted hazard ratio [aHR] for age 70 to 79 years, 1.021 [95% confidence interval (CI), 1.01 to 1.031]; for age ≥80 years, 1.035 [1.01 to 1.06]; and for ASA score of 3, 1.02 [1.01 to 1.031]). Similar results were seen in the subgroup who underwent primary surgery. Within 2 weeks following surgery, the highest frequency of falls occurred at 3 to 7 days postoperatively. The lowest fall rate was observed in the evening (6 to 10 p.m.). Morbidities, including rib, spine, and extremity fractures, were recorded for 14 patients, but none of these patients underwent operative treatment related to the fall. The NHISIH implemented a comprehensive nursing care service in May 2015 and a fall protocol in May 2017, but the annual incidence rate did not improve. The fall rate was higher after thoracolumbar surgeries (2.47%) than after cervical surgeries (1.20%). Moreover, a higher fall rate was observed in thoracolumbar cases with a greater number of fusion levels and revision spine surgeries. Conclusions: Patients with advanced age, more comorbidities, a greater number of fusion levels, and revision surgeries and who are female are more vulnerable to in-hospital falls after spine surgery. Novel strategies that target these risk factors are warranted. Level of Evidence: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.


  • Open Access

    Clinical Outcomes of Triple Tension Band Wirings in Comminuted Patellar Fracture: A Comparison with Conventional Tension Band Wiring

    by Hyun-Cheol Oh, Han-Kook Yoon, Joong-Won Ha, Sang Hoon Park, Sungwoo Lee

    오현철, et al. J Korean Fract Soc. 2024 May;37(2):82-86. https://doi.org/10.12671/jkfs.2024.37.2.82


  • Open Access

    Is ulnar shortening osteotomy or the wafer procedure better for ulnar impaction syndrome?: A systematic review and meta-analysis

    by Joong Won Doctorate Ha, Young Woo Master’s Degree Kwon, Sujung Bachelor’s Degree Lee, Hyunsun Ph.D(Biostatistics) Lim, Jinho Bachelor’s Degree Lee, Chae Kwang Bachelor’s Degree Lim, Jun-Ku Doctorate Lee

    Background: Wrist pain on the ulnar side is often caused by ulnar impaction syndrome (UIS). Idiopathic UIS requires surgical treatment when conservative treatment fails. The 2 main surgical procedures used are the wafer procedure and ulnar shortening osteotomy (USO) of the metaphysis or diaphysis. This review aimed to analyze comparative studies of the 2 procedures in UIS to determine clinical outcomes and complications. Methods: One prospective and 5 retrospective comparison trials were retrieved from the PubMed, Embase, and Cochrane Library databases. The primary outcomes were treatment effectiveness; pain visual analog scale (VAS), disabilities of the arm, shoulder, and hand (DASH) score, Mayo wrist, and Darrow scores. The incidence of postoperative complications formed the secondary outcome. Results: The selected studies included 107 patients who underwent the wafer procedure (G1) and 117 patients who underwent USO (G2). The wafer procedure had the benefits of less postoperative immobilization and an early return to work. However, there were no significant differences in the postoperative pain improvement and functional scores. All 6 studies reported high total complication rates and reoperation with USO. The most frequent complication was implant-related discomfort or irritation; subsequent plate removal was the most common reason for a secondary operation. Conclusions: There was no difference in pain improvement or the postoperative functional score between the groups. Nevertheless, postoperative complications were the major pitfalls of USO. As the specialized shortening system advances further, a high-level study will be necessary to determine the surgical option in UIS.


  • Open Access

    Adjacent Segment Pathology in Spinal Fusion Surgery

    by Tae-Yup Kim, Yung Park, Jae-Won Shin, Ji-Won Kwon, Byung-Ho Lee, Si-Young Park, Joong-Won Ha, Kyung-Soo Suk, Seong-Hwan Moon, Hak-Sun Kim

    김태엽, et al. J Korean Soc Spine Surg. 2023 Jun;30(2):83-90. https://doi.org/10.4184/jkss.2023.30.2.83

  • Open Access

    Combined PCL and PLC Reconstruction Improves Residual Laxity in PCL Injury Patients with Posterolateral Knee Laxity Less Than Grade III

    by Han-Kook Yoon, Sang-Hoon Park, Hyun-Cheol Oh, Joong-Won Ha, Heemin Choi

    Yoon HK, et al. Yonsei Med J. 2023 May;64(5):313-319. https://doi.org/10.3349/ymj.2022.0487


  • Open Access

    Joint Replacement Surgery in Patients with Rheumatoid Arthritis in South Korea: Analysis of a Large National Database

    by Han-Kook Yoon, Sang-Ok Seok, Hyun-Cheol Oh, Joong-Won Ha, Sunghun Park, Sang-Hoon Park

    Yoon HK, et al. Clin Orthop Surg. 2022 Nov;14:e96. https://doi.org/10.4055/cios21274


  • The inter-and intra-observer reliability of volar angulation measurements in a fifth metacarpal neck fracture

    by Jun-Ku Lee, Weon Min Cho, Hyun Il Lee, Joong Won Ha, Jin Woo Cho, Junhan Kim, Soo-Hong Han

    Introduction The fifth metacarpal neck fracture is the most common metacarpal fracture. The palmar angulation from the fracture displacement is critical for determining treatment, yet there is no consensus regarding the angulation measurement method or the surgical cut-off value. This study aimed to identify a reliable measurement method for assessing palmar angulation. We evaluated inter-observer and intra-observer validation of measuring palmar angulation in oblique plain X-ray and computed tomography (CT) sagittal cuts. Materials and methods We identified surgically treated patients for acute isolated fifth metacarpal neck fracture between January 1, 2008, and December 31, 2020, and obtained preoperative, opposite hand, and final follow-up oblique X-rays and sagittal computed tomography (CT) radiograms. The oblique radiograph was taken with a 45° posteroanterior pronation. The metacarpal neck palmar angulation was measured in the radiograms using the metacarpal neck-shaft center (MNSC) angle and the shaft articular surface (SAS) angle methods by three orthopedic surgeons in two sessions. For the CT radiograms, each measurer selected the sagittal slot at their discretion to measure the angle. The final palmar angulation was the average of six measurements (two sessions, three measurers per session). Results The study included 51 patients; the average age was 32.5 (range 18–73) years, with 46 men and 5 women. The MNSC angle inter-observer reliability was better than the SAS angle. The MNSC angle inter-observer reliability was better than that of SAS angle. Intraclass coefficients (ICCs) for the MNSC angle demonstrated an excellent inter-observer agreement among the three measurers in the first (0.93) and second (0.88) session compared to ICCs for the SAS angle in the first (0.81) and second (0.87) session. The MNSC angle intra-observer reliability was also better than the SAS angle, with higher ICCs. Preoperative CT radiograms were available for 42 patients. Using CT scans for measurements, in the two sessions, the MNSC angle inter-observer reliability was higher than that of the SAS angle [MNSC: 0.83; SAS: 0.35], second [MSNC: 0.85; SAS: 0.81]. The intra-observer reliability was also better in the MNSC angle. When comparing average value among obtained radiograms, the physiologic angulation of the opposite hand oblique X-ray had the smallest average value, followed by preoperative CT and preoperative oblique radiography. Overall, the SAS angle measurement had a slightly larger angle than the MNSC method in the fractured and non-fractured hand measurements. Finally, a serial comparison of the oblique X-rays (pre-and postoperative, final follow-up, and the opposite hand with closed reduction and internal fixation) indicated that the angulation significantly decreased, and the post-operative values did not differ from the final follow-up X-ray for either method. Conclusions The palmar angulation measurement in 45° pronated oblique X-ray using the MNSC angle method had good-to-excellent reliability, with superior results to sagittal CT radiograms. Although the angle is likely overestimated, the MNSC method is reliable for judging the fracture degree and reduction adequacy after surgery compared to the non-fractured hand physiologic angulation.