MOMartin O'REilly

Martin O'REilly

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Martin O'REilly has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Machine learning in sports science: challenges and opportunities

    by Chris Richter, Martin O’reilly, Eamonn Delahunt

    Sport scientists could benefit from knowing about the processes underpinning machine learning (ML) and its practical applications, as it has substantial implications for our field. ML has already h...


  • Open Access

    Interpretable Time Series Classification using Linear Models and Multi-resolution Multi-domain Symbolic Representations

    by Thach Le Nguyen, Severin Gsponer, Iulia Ilie, Martin O'Reilly, Georgiana Ifrim

    The time series classification literature has expanded rapidly over the last decade, with many new classification approaches published each year. Prior research has mostly focused on improving the accuracy and efficiency of classifiers, with interpretability being somewhat neglected. This aspect of classifiers has become critical for many application domains and the introduction of the EU GDPR legislation in 2018 is likely to further emphasize the importance of interpretable learning algorithms. Currently, state-of-the-art classification accuracy is achieved with very complex models based on large ensembles (COTE) or deep neural networks (FCN). These approaches are not efficient with regard to either time or space, are difficult to interpret and cannot be applied to variable-length time series, requiring pre-processing of the original series to a set fixed-length. In this paper we propose new time series classification algorithms to address these gaps. Our approach is based on symbolic representations of time series, efficient sequence mining algorithms and linear classification models. Our linear models are as accurate as deep learning models but are more efficient regarding running time and memory, can work with variable-length time series and can be interpreted by highlighting the discriminative symbolic features on the original time series. We show that our multi-resolution multi-domain linear classifier (mtSS-SEQL+LR) achieves a similar accuracy to the state-of-the-art COTE ensemble, and to recent deep learning methods (FCN, ResNet), but uses a fraction of the time and memory required by either COTE or deep models. To further analyse the interpretability of our classifier, we present a case study on a human motion dataset collected by the authors. We release all the results, source code and data to encourage reproducibility.

  • Reliability, Validity and Utility of Inertial Sensor Systems for Postural Control Assessment in Sport Science and Medicine Applications: A Systematic Review

    by William Johnston, Martin O’reilly, Rob Argent, Brian Caulfield

    Background Recent advances in mobile sensing and computing technology have provided a means to objectively and unobtrusively quantify postural control. This has resulted in the rapid development and evaluation of a series of wearable inertial sensor-based assessments. However, the validity, reliability and clinical utility of such systems is not fully understood. Objectives This systematic review aims to synthesise and evaluate studies that have investigated the ability of wearable inertial sensor systems to validly and reliably quantify postural control performance in sports science and medicine applications. Methods A systematic search strategy utilising the PRISMA guidelines was employed to identify eligible articles through ScienceDirect, Embase and PubMed databases. In total, 47 articles met the inclusion criteria and were evaluated and qualitatively synthesised under two main headings: measurement validity and measurement reliability. Furthermore, studies that investigated the utility of these systems in clinical populations were summarised and discussed. Results After duplicate removal, 4374 articles were identified with the search strategy, with 47 papers included in the final review. In total, 28 studies investigated validity in healthy populations, and 15 studies investigated validity in clinical populations; 13 investigated the measurement reliability of these sensor-based systems. Conclusions The application of wearable inertial sensors for sports science and medicine postural control applications is an evolving field. To date, research has primarily focused on evaluating the validity and reliability of a heterogeneous set of assessment protocols, in a laboratory environment. While researchers have begun to investigate their utility in clinical use cases such as concussion and musculoskeletal injury, most studies have leveraged small sample sizes, are of low quality and use a variety of descriptive variables, assessment protocols and sensor-mounting locations. Future research should evaluate the clinical utility of these systems in large high-quality prospective cohort studies to establish the role they may play in injury risk identification, diagnosis and management. This systematic review was registered with the International Prospective Register of Systematic Reviews on 10 August 2018 (PROSPERO registration: CRD42018106363): https://www.crd.york.ac.uk/PROSPERO/display_record.php?RecordID=106363.


  • Association of Dynamic Balance With Sports-Related Concussion: A Prospective Cohort Study

    by William Johnston, Martin O’REilly, Ciara Duignan, Mairead Liston, Rod McLoughlin, Garrett F. Coughlan, Brian Caulfield

    Background: Concussion is one of the most common sports-related injuries, with little understood about the modifiable and nonmodifiable risk factors. Researchers have yet to evaluate the association between modifiable sensorimotor function variables and concussive injury. Purpose: To investigate the association between dynamic balance performance, a discrete measure of sensorimotor function, and concussive injuries. Study Design: Cohort study (diagnosis); Level of evidence, 3. Methods: A total of 109 elite male rugby union players were baseline tested in dynamic balance performance while wearing an inertial sensor and prospectively followed during the 2016-2017 rugby union season. The sample entropy of the inertial sensor gyroscope magnitude signal was derived to provide a discrete measure of dynamic balance performance. Logistic regression modeling was then used to investigate the association among the novel digital biomarker of balance performance, known risk factors of concussion (concussion history, age, and playing position), and subsequent concussive injury. Results: Participant demographic data (mean ± SD) were as follows: age, 22.6 ± 3.6 years; height, 185 ± 6.5 cm; weight, 98.9 ± 12.5 kg; body mass index, 28.9 ± 2.9 kg/m 2 ; and leg length, 98.8 ± 5.5 cm. Of the 109 players, 44 (40.3%) had a history of concussion, while 21 (19.3%) sustained a concussion during the follow-up period. The receiver operating characteristic analysis for the anterior sample entropy demonstrated a statistically significant area under the curve (0.64; 95% CI, 0.52-0.76; P < .05), with the cutoff score of anterior sample entropy ≥1.2, which maximized the sensitivity (76.2%) and specificity (53.4%) for identifying individuals who subsequently sustained a concussion. Players with suboptimal balance performance at baseline were at a 2.81-greater odds (95% CI, 1.02-7.74) of sustaining a concussion during the rugby union season than were those with optimal balance performance, even when controlling for concussion history. Conclusion: Rugby union players who possess poorer dynamic balance performance, as measured by a wearable inertial sensor during the Y balance test, have a 3-times-higher relative risk of sustaining a sports-related concussion, even when controlling for history of concussion. These findings have important implications for research and clinical practice, as it identifies a potential modifiable risk factor. Further research is required to investigate this association in a large cohort consisting of males and females across a range of sports.


  • Top Cited Papers

    Wearable Inertial Sensor Systems for Lower Limb Exercise Detection and Evaluation: A Systematic Review

    by Martin O’rEilly, Brian Caulfield, Tomas Ward, William Johnston, Cailbhe Doherty

    Analysis of lower limb exercises is traditionally completed with four distinct methods: (1) 3D motion capture; (2) depth-camera-based systems; (3) visual analysis from a qualified exercise professional; and (4) self-assessment. Each method is associated with a number of limitations.


  • Open Access

    A Wearable Sensor-Based Exercise Biofeedback System: Mixed Methods Evaluation of Formulift

    by Martin Aidan O'REilly, Patrick Slevin, Tomas Ward, Brian Caulfield

    Mobile and tablet apps, ubiquitous and pervasive computing, wearable computing and domotics for health.


  • Open Access

    Inter-session Test-retest Reliability of the Quantified Y Balance Test

    by William Johnston, Martin O’reilly, Garrett F. Coughlan, Brian Caulfield


  • Open Access

    Mobile App to Streamline the Development of Wearable Sensor-Based Exercise Biofeedback Systems: System Development and Evaluation

    by Martin O'REilly, Joe Duffin, Tomas Ward, Brian Caulfield

    Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet


  • Open Access

    Feature-Free Activity Classification of Inertial Sensor Data With Machine Vision Techniques: Method, Development, and Evaluation

    by Jose Juan Dominguez Veiga, Martin O'REilly, Darragh Whelan, Brian Caulfield, Tomas E Ward

    Mobile and tablet apps, ubiquitous and pervasive computing, wearable computing and domotics for health.


  • Technology in Strength and Conditioning: Assessing Bodyweight Squat Technique With Wearable Sensors

    by Martin A. O'REilly, Darragh F. Whelan, Tomas E. Ward, Eamonn Delahunt, Brian M. Caulfield

    O'Reilly, MA, Whelan, DF, Ward, TE, Delahunt, E, and Caulfield, BM. Technology in strength and conditioning: assessing bodyweight squat technique with wearable sensors. J Strength Cond Res 31(8): 2303–2312, 2017—Strength and conditioning (S&C) coaches offer expert guidance to help those they work with achieve their personal fitness goals. However, it is not always practical to operate under the direct supervision of an S&C coach and consequently individuals are often left training without expert oversight. Recent developments in inertial measurement units (IMUs) and mobile computing platforms have allowed for the possibility of unobtrusive motion tracking systems and the provision of real-time individualized feedback regarding exercise performance. These systems could enable S&C coaches to remotely monitor sessions and help individuals record their workout performance. One aspect of such technologies is the ability to assess exercise technique and detect common deviations from acceptable exercise form. In this study, we investigate this ability in the context of a bodyweight (BW) squat exercise. Inertial measurement units were positioned on the lumbar spine, thighs, and shanks of 77 healthy participants. Participants completed repetitions of BW squats with acceptable form and 5 common deviations from acceptable BW squatting technique. Descriptive features were extracted from the IMU signals for each BW squat repetition, and these were used to train a technique classifier. Acceptable or aberrant BW squat technique can be detected with 98% accuracy, 96% sensitivity, and 99% specificity when using features derived from all 5 IMUs. A single IMU system can also distinguish between acceptable and aberrant BW squat biomechanics with excellent accuracy, sensitivity, and specificity. Detecting exact deviations from acceptable BW squatting technique can be achieved with 80% accuracy using a 5 IMU system and 72% accuracy when using a single IMU positioned on the right shank. These results suggest that IMU-based systems can distinguish between acceptable and aberrant BW squat technique with excellent accuracy with a single IMU system. Identification of exact deviations is also possible but multi-IMU systems outperform single IMU systems.