AKAjay Kapur

Ajay Kapur

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ajay Kapur has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Adoption of Hypofractionated and Ultrahypofractionated Adjuvant Radiation Therapy for Breast Cancer Across Main and Community Centers Within a Single Healthcare System

    by Leila T. Tchelebi, Ajay Kapur, Clary Evans

    Purpose/Objective(s): Adjuvant radiation therapy (RT) is an effective treatment in the management of patients with breast cancer. Evidence supports both standard fractionation and, more recently, moderate hypofractionation and ultra hypofractionation leading to a potential diversity of clinical practice. Whether or not physicians at main academic centers adopt hypofractionated regimens more readily than those working at community centers is not known. Practice patterns were analyzed within our large healthcare network comprising one main and eight community sites before and after 2020. Materials/Methods: Patients treated with adjuvant breast RT between 2017 and 2022 in our radiation oncology department were identified. Treatment techniques were evaluated: standard fractionation (25–28 fractions to 50–50.4 Gy), moderate hypofractionation (15–16 fractions to 40.05–42.56 Gy), and ultra hypofractionation (5 fractions of 26–30 Gy) for intact breast, partial breast, and chest wall cases. Use of each technique was compared between the main academic center (Main) versus eight community sites (Community) in two time periods, 2017–2019 and 2020–2022. Differences were assessed using z-ratios for the difference between independent proportions. Results: There was a statistically significant decrease in the use of standard fractionation for intact breast and chest wall cases from the early to the late period at both the community sites and the main center; however, a higher proportion of patients were treated with standard fractionation at the community sites versus the main center in the late period (7.8% community versus 2.0% main, p < 0.01 for intact breast and 80.7% community versus 37.4% main, p < 0.01 for chest wall). There was a statistically significant increase in the use of hypofractionation for intact breast and chest wall cases from the early to the late period at both the community sites and the main center; however, a higher proportion of patients were treated with hypofractionation at the main center versus the community sites during the late period (92.2% community versus 98.0% main, p < 0.01 for intact breast and 19.3% community versus 62.6% main, p < 0.01). Conclusions: The present study shows that recent trial evidence supporting the use of shorter RT treatments changed practice among providers more rapidly at our main academic center versus our community sites. The reasons for this difference are not known; however, standardization of treatment by implementation of an adjuvant RT treatment algorithm may facilitate uniform care among patients with breast cancer and we are investigating the impact of this approach.

  • Open Access

    Posttraumatic Growth in Radiation Medicine During the COVID-19 Outbreak

    by Ajay Kapur, Brett Rudin, Louis Potters


  • Why Smart Oncology Clinicians do Dumb Things: A Review of Cognitive Bias in Radiation Oncology

    by Suzanne B. Evans, Daylian Cain, Ajay Kapur, Derek Brown, Todd Pawlicki


  • Improving efficiency and safety in external beam radiation therapy treatment delivery using a Kaizen approach

    by Ajay Kapur, Nilda Adair, Mildred O’bRien, Nikoleta Naparstek, Thomas Cangelosi, Petrina Zuvic, Sherin Joseph, Jason Meier, Beatrice Bloom, Louis Potters


  • Stopping-power ratios for clinical electron beams from a scatter-foil linear accelerator

    by Ajay Kapur, Chang-Ming Ma

    Restricted mass collision stopping-power ratios for electron beams from a scatter-foil medical linear accelerator (Varian Clinac 2100C) were calculated for various combinations of beams, phantoms and detector materials using the Monte Carlo method. The beams were of nominal energy 6, 12 or 20 MeV, with square dimensions 1 × 1 cm2 to 10 × 10 cm2. They were incident at nominal SSDs of 100 or 120 cm and inclined at 90° or 30° to the surface of homogeneous water phantoms or water phantoms interspersed with layered lung or bone-like materials. The broad beam water-to-air stopping-power ratios were within 1.3% of the AAPM TG21 protocol values and consistent with the results of Ding et al to within 0.2%. On the central axis the stopping-power ratio variations for narrow beams compared with normally incident broad beams were 0.1% or less for water-to-LiF-100, graphite, ferrous sulfate dosimeter solution, polystyrene and PMMA, 0.5% for water-to-silicon and 1% for water-to-air and water-to-photographic-film materials. The transverse variations of the stopping-power ratios were up to 4% for water-to-silicon, 7% for water-to-photographic-film materials and 10% for water-to-air in the penumbral regions (where the dose was 10% of the global dose maximum) at shallow depths compared with the values at the same depths on the central axis. In the inhomogeneous phantoms studied, the stopping-power ratio correction factors varied more significantly for air, followed by photographic materials and silicon, at various depths on the central axis in the heterogeneous regions. For the simple layered phantoms studied, the estimation of the stopping-power ratio correction factors based on the relative electron-density derived effective depth approach yielded results that were within 0.5% of the Monte Carlo derived values for all the detector materials studied.