Corey P. Neu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Corey P. Neu has a total of 232 co-authors. Here are the top co-authors by number of shared publications:
Stephanie E. Schneider
Department of Mechanical Engineering University of Colorado Boulder Boulder Colorado USA
16 shared publicationsEmily Y. Miller
Biomedical Engineering Program University of Colorado Boulder Boulder Colorado USA
15 shared publicationsBenjamin Seelbinder
Paul M. Rady Department of Mechanical Engineering, University of Colorado Boulder, Boulder, Colorado
12 shared publicationsHongtian Zhu
Paul M. Rady Department of Mechanical Engineering University of Colorado Boulder Boulder Colorado USA
12 shared publicationsAdrienne K. Scott
Paul M. Rady Department of Mechanical Engineering, University of Colorado Boulder, Boulder, CO, USA
11 shared publicationsJeanne E. Barthold
Department of Mechanical Engineering, University of Colorado Boulder; Boulder, CO USA
10 shared publications
Latest Publications
- 7 November 2026
- Published by Wiley in Advanced Healthcare Materials
Shelf‐Stable Human‐Derived Granular Extracellular Matrix (gECM) Hydrogel Wafers as 2.5D Substrates for Microphysiological Modeling
Understanding disease pathology and evaluating emerging therapeutics require in vitro models that accurately recapitulate human tissue environments. However, existing microphysiological systems often compromise either biomimicry or ease‐of‐use, limiting widespread adoption and scalability. Here, we present lyophilized granular extracellular matrix (gECM) hydrogel wafers as shelf‐stable, humanized 2.5D substrates that enable physiologically relevant modeling while simplifying integration into experimental workflows. Derived from decellularized human cartilage and bone, our gECM hydrogel wafers retain tissue‐specific architecture while introducing microporosity and surface topography through lyophilization. These wafers maintain swelling behavior, structural integrity, and mechanical properties over three months of room‐temperature storage, allowing pre‐fabrication and on‐demand use without loss of function. gECM hydrogel wafers support direct cell seeding without encapsulation and sustain viability and proliferation of human adipose‐derived mesenchymal stromal cells over 21 days. Furthermore, wafers can be readily integrated into proof‐of‐concept on‐chip fabrication with in situ hydration and transport of large biomolecules. Together, this platform bridges the gap between conventional 2D culture ease‐of‐use and 3D biomaterial biomimicry, providing a scalable, physiologically‐relevant, and humanized in vitro model approach that shows potential for future high‐throughput disease studies and therapeutic screening.
- 7 November 2026
- Published by Wiley in Advanced Healthcare Materials
Shelf‐Stable Human‐Derived Granular Extracellular Matrix (gECM) Hydrogel Wafers as 2.5D Substrates for Microphysiological Modeling
Understanding disease pathology and evaluating emerging therapeutics require in vitro models that accurately recapitulate human tissue environments. However, existing microphysiological systems often compromise either biomimicry or ease‐of‐use, limiting widespread adoption and scalability. Here, we present lyophilized granular extracellular matrix (gECM) hydrogel wafers as shelf‐stable, humanized 2.5D substrates that enable physiologically relevant modeling while simplifying integration into experimental workflows. Derived from decellularized human cartilage and bone, our gECM hydrogel wafers retain tissue‐specific architecture while introducing microporosity and surface topography through lyophilization. These wafers maintain swelling behavior, structural integrity, and mechanical properties over three months of room‐temperature storage, allowing pre‐fabrication and on‐demand use without loss of function. gECM hydrogel wafers support direct cell seeding without encapsulation and sustain viability and proliferation of human adipose‐derived mesenchymal stromal cells over 21 days. Furthermore, wafers can be readily integrated into proof‐of‐concept on‐chip fabrication with in situ hydration and transport of large biomolecules. Together, this platform bridges the gap between conventional 2D culture ease‐of‐use and 3D biomaterial biomimicry, providing a scalable, physiologically‐relevant, and humanized in vitro model approach that shows potential for future high‐throughput disease studies and therapeutic screening.
- 17 August 2026
- Published by Wiley in Current Protocols
- Vol. 6 (8)
Deformation Microscopy: A Protocol for Full‐Field, Micro‐ to Nano‐Scale Imaging of Mechanics in Extracellular Matrix, Cells, and Nuclei
The internal mechanics of living tissues, cells, and nuclei exhibit exquisite complexity, depend on dynamic structural changes, and influence biological functions such as tissue remodeling, cell homeostasis and migration, and gene expression. Full‐field methods to reveal the internal mechanics of extracellular matrix, cells, and nuclei are emerging and can uncover new discoveries in mechanobiology. Here we detail a noninvasive technology to probe the internal mechanics of extracellular matrix, cells, and nuclei using a combination of imaging and deformation‐matching computational approaches. Important to this technology is the acquisition of image data showing sufficient spatial and temporal resolution to capture a motion event, which can be readily evaluated using automated assessment of structural features. With careful consideration of image acquisition and processing parameters, micron‐ to nanometer‐scale intracellular and intranuclear mechanics can be reliably measured with small displacement errors (Basic Protocol : Quantifying cellular and nuclear deformation using deformation microscopy
- 17 August 2026
- Published by Wiley in Current Protocols
- Vol. 6 (8)
Deformation Microscopy: A Protocol for Full‐Field, Micro‐ to Nano‐Scale Imaging of Mechanics in Extracellular Matrix, Cells, and Nuclei
The internal mechanics of living tissues, cells, and nuclei exhibit exquisite complexity, depend on dynamic structural changes, and influence biological functions such as tissue remodeling, cell homeostasis and migration, and gene expression. Full‐field methods to reveal the internal mechanics of extracellular matrix, cells, and nuclei are emerging and can uncover new discoveries in mechanobiology. Here we detail a noninvasive technology to probe the internal mechanics of extracellular matrix, cells, and nuclei using a combination of imaging and deformation‐matching computational approaches. Important to this technology is the acquisition of image data showing sufficient spatial and temporal resolution to capture a motion event, which can be readily evaluated using automated assessment of structural features. With careful consideration of image acquisition and processing parameters, micron‐ to nanometer‐scale intracellular and intranuclear mechanics can be reliably measured with small displacement errors (Basic Protocol : Quantifying cellular and nuclear deformation using deformation microscopy
- Open Access
- 14 July 2026
- Published by Wiley in Advanced Science
- Vol. 13 (55) , e76561
High‐Throughput Mechanical Rupture of Nuclear Envelope and the Intracellular Dynamics of Massive Wound Repair
The dynamics of nuclear envelope rupture and wound repair are critical biological processes that play essential roles in cell homeostasis. Previous studies on nuclear envelope repair dynamics have mainly focused on small ruptures induced by low‐throughput tools such as laser ablation and atomic force microscopy. Here, a device is presented that deterministically porates the cell membrane and nuclear envelope in high throughput, with applications in single‐cell studies of wound repair dynamics and in statistical assessments of cell poration. The device consists of sharp nanostructures in arrays of microchannels, enabling precise and localized disruption at both the plasma membrane and nuclear envelope while preserving cell viability. The distribution of endosomal sorting complexes required for transport (ESCRT) proteins after mechanical disruption at both the plasma membrane and nuclear envelope highlights the cell recovery strategy for severe wounds. Interestingly, during this extreme rupture, resources seem to be allocated more toward nuclear envelope repair. High‐throughput mechanoporation on membrane systems provides a new perspective on studying complex wound repair dynamics, opening promising avenues for further research in the field of wound healing mechanisms.
- 14 July 2026
- Published by Wiley in Advanced Science
- Vol. 13 (55) , e76561
Open AccessHigh‐Throughput Mechanical Rupture of Nuclear Envelope and the Intracellular Dynamics of Massive Wound Repair
The dynamics of nuclear envelope rupture and wound repair are critical biological processes that play essential roles in cell homeostasis. Previous studies on nuclear envelope repair dynamics have mainly focused on small ruptures induced by low‐throughput tools such as laser ablation and atomic force microscopy. Here, a device is presented that deterministically porates the cell membrane and nuclear envelope in high throughput, with applications in single‐cell studies of wound repair dynamics and in statistical assessments of cell poration. The device consists of sharp nanostructures in arrays of microchannels, enabling precise and localized disruption at both the plasma membrane and nuclear envelope while preserving cell viability. The distribution of endosomal sorting complexes required for transport (ESCRT) proteins after mechanical disruption at both the plasma membrane and nuclear envelope highlights the cell recovery strategy for severe wounds. Interestingly, during this extreme rupture, resources seem to be allocated more toward nuclear envelope repair. High‐throughput mechanoporation on membrane systems provides a new perspective on studying complex wound repair dynamics, opening promising avenues for further research in the field of wound healing mechanisms.
- Open Access
Particle-Only gECM Wafers Enable Cohesive, ECM-Rich Scaffolds Without Secondary Polymers
Granular extracellular matrix (gECM)-based biomaterials commonly contain polymer components to improve scaffold cohesion and handling during fabrication and use. However, these polymer hydrogel components may dilute ECM content and increase fabrication and regulatory complexity. This study evaluated whether particle-only gECM wafers could serve as a simplified alternative to hydrogel-based gECM scaffolds while maintaining structural, mechanical, and biological performance. Decellularized human cartilage and skin tissues were processed and fabricated into three scaffold formats: gECM hydrogels, freeze-dried gECM hydrogel wafers, and freeze-dried particle-only gECM wafers. Across fabrication methods, scaffold swelling, volume fraction, and stiffness were strongly influenced by both tissue type and fabrication approach. gECM hydrogels exhibited the greatest swelling and lowest stiffness, while gECM wafers displayed higher volume fractions and greater mechanical stiffness. Notably, gECM particle-only wafers achieved performance comparable to gECM hydrogel wafers despite the absence of a secondary polymer network. Particle-only wafers also maintained swelling behavior and structural properties over 3 months of dry storage at room temperature, with only modest decreases in stiffness. In vitro studies showed sustained cell viability over 14 days on particle-only wafers, with chondrocytes infiltrating cartilage wafers and fibroblasts remaining primarily surface-localized on skin wafers. In addition, particle-only wafers remained cohesive during implantation into a bovine cartilage defect model. These findings demonstrate that particle-only gECM wafers can achieve structural integrity, mechanical performance, and cytocompatibility without the need for an additional polymer network, highlighting a simplified and ECM-rich biomaterial platform. By eliminating polymer carriers and enabling dry storage with preserved function, this approach supports the development of off-the-shelf, translationally accessible gECM particle-only wafers for tissue engineering applications.
Open AccessParticle-Only gECM Wafers Enable Cohesive, ECM-Rich Scaffolds Without Secondary Polymers
Granular extracellular matrix (gECM)-based biomaterials commonly contain polymer components to improve scaffold cohesion and handling during fabrication and use. However, these polymer hydrogel components may dilute ECM content and increase fabrication and regulatory complexity. This study evaluated whether particle-only gECM wafers could serve as a simplified alternative to hydrogel-based gECM scaffolds while maintaining structural, mechanical, and biological performance. Decellularized human cartilage and skin tissues were processed and fabricated into three scaffold formats: gECM hydrogels, freeze-dried gECM hydrogel wafers, and freeze-dried particle-only gECM wafers. Across fabrication methods, scaffold swelling, volume fraction, and stiffness were strongly influenced by both tissue type and fabrication approach. gECM hydrogels exhibited the greatest swelling and lowest stiffness, while gECM wafers displayed higher volume fractions and greater mechanical stiffness. Notably, gECM particle-only wafers achieved performance comparable to gECM hydrogel wafers despite the absence of a secondary polymer network. Particle-only wafers also maintained swelling behavior and structural properties over 3 months of dry storage at room temperature, with only modest decreases in stiffness. In vitro studies showed sustained cell viability over 14 days on particle-only wafers, with chondrocytes infiltrating cartilage wafers and fibroblasts remaining primarily surface-localized on skin wafers. In addition, particle-only wafers remained cohesive during implantation into a bovine cartilage defect model. These findings demonstrate that particle-only gECM wafers can achieve structural integrity, mechanical performance, and cytocompatibility without the need for an additional polymer network, highlighting a simplified and ECM-rich biomaterial platform. By eliminating polymer carriers and enabling dry storage with preserved function, this approach supports the development of off-the-shelf, translationally accessible gECM particle-only wafers for tissue engineering applications.
- Open Access
Human Osteochondral Granular Extracellular Matrix (gECM) Hydrogels Drive Tissue-Specific Composition and Mechanics
Osteochondral defects remain a major clinical challenge due to the limited regenerative capacity of cartilage and the complexity of the osteochondral interface. Here, we present a human-derived granular extracellular matrix (gECM) hydrogel platform designed for translational osteochondral repair. Using otherwise discarded human donor tissues, we developed cartilage and bone gECM hydrogels under current good manufacturing practice workflows. These materials are shear-thinning, immediately hold their form, and crosslink under physiological conditions to form stable constructs. Proteomic analysis confirmed that cartilage and bone gECM retain distinct tissue-specific biochemical signatures, while mechanical characterization demonstrated tissue-relevant stiffness, with bone gECM hydrogels exhibiting greater stiffness than cartilage gECM hydrogel. Particle packing density primarily governed viscosity, whereas tissue type contributed strongly to bulk stiffness. Together, these findings establish a scalable, human-derived gECM platform that integrates tissue-specific structural and mechanical cues, and advances a clinically translatable strategy for osteochondral repair.
Open AccessHuman Osteochondral Granular Extracellular Matrix (gECM) Hydrogels Drive Tissue-Specific Composition and Mechanics
Osteochondral defects remain a major clinical challenge due to the limited regenerative capacity of cartilage and the complexity of the osteochondral interface. Here, we present a human-derived granular extracellular matrix (gECM) hydrogel platform designed for translational osteochondral repair. Using otherwise discarded human donor tissues, we developed cartilage and bone gECM hydrogels under current good manufacturing practice workflows. These materials are shear-thinning, immediately hold their form, and crosslink under physiological conditions to form stable constructs. Proteomic analysis confirmed that cartilage and bone gECM retain distinct tissue-specific biochemical signatures, while mechanical characterization demonstrated tissue-relevant stiffness, with bone gECM hydrogels exhibiting greater stiffness than cartilage gECM hydrogel. Particle packing density primarily governed viscosity, whereas tissue type contributed strongly to bulk stiffness. Together, these findings establish a scalable, human-derived gECM platform that integrates tissue-specific structural and mechanical cues, and advances a clinically translatable strategy for osteochondral repair.
- Open Access
Lamin A/C coordinates nuclear mechanics, chromatin architecture, and transcriptional homeostasis in skeletal muscle in vivo
The nuclear lamina provides mechanical integrity to the eukaryotic nucleus and organizes lamina-associated chromatin domains that are important for chromatin architecture and gene-expression regulation. Lamin A/C, a major component of the nuclear lamina, is disrupted in hereditary laminopathies and has also been implicated in aging-associated nuclear dysfunction. Although the mechanical role of Lamin A/C has been extensively studied in vitro , particularly in monolayer cell culture and isolated nuclei, its role in maintaining nuclear mechanics and chromatin organization in intact tissues remains incompletely understood. Here, we investigated how partial and complete Lamin A/C disruption affects nuclear shape, chromatin architecture, intranuclear mechanics, and gene expression in vivo . Across multiple murine tissues, Lamin A/C deficiency did not cause a generalized collapse of nuclear shape or gross tissue architecture. Instead, Lamin A/C disruption preferentially altered chromatin architecture in mechanically stiff tissues, including skeletal muscle and heart. Using live in vivo deformation microscopy during controlled hindlimb muscle stimulation, we quantified real-time multiscale deformation of skeletal muscle tissue and nuclei. These measurements revealed reduced effective nuclear stiffness and altered load sharing between euchromatin-rich and heterochromatin-rich domains after Lamin A/C loss. Super-resolution imaging further showed that partial and complete Lamin A/C disruption uncoupled H3K9me3 from DAPI-dense heterochromatin, indicating a spatial disruption of repressive chromatin organization. Exploratory ATAC-seq suggested increased chromatin accessibility in heterozygous muscle, whereas RNA-seq showed that complete Lamin A/C loss caused broad myopathic transcriptional dysregulation while partial loss preserved a near-wild-type transcriptomic state. Integrated analysis identified HDAC2 as a candidate mechanosensitive compensatory node that may help buffer gene expression after partial Lamin A/C disruption. Together, these results establish Lamin A/C as an in vivo coordinator of nuclear mechanics, heterochromatin organization, and transcriptional homeostasis in skeletal muscle.
Open AccessLamin A/C coordinates nuclear mechanics, chromatin architecture, and transcriptional homeostasis in skeletal muscle in vivo
The nuclear lamina provides mechanical integrity to the eukaryotic nucleus and organizes lamina-associated chromatin domains that are important for chromatin architecture and gene-expression regulation. Lamin A/C, a major component of the nuclear lamina, is disrupted in hereditary laminopathies and has also been implicated in aging-associated nuclear dysfunction. Although the mechanical role of Lamin A/C has been extensively studied in vitro , particularly in monolayer cell culture and isolated nuclei, its role in maintaining nuclear mechanics and chromatin organization in intact tissues remains incompletely understood. Here, we investigated how partial and complete Lamin A/C disruption affects nuclear shape, chromatin architecture, intranuclear mechanics, and gene expression in vivo . Across multiple murine tissues, Lamin A/C deficiency did not cause a generalized collapse of nuclear shape or gross tissue architecture. Instead, Lamin A/C disruption preferentially altered chromatin architecture in mechanically stiff tissues, including skeletal muscle and heart. Using live in vivo deformation microscopy during controlled hindlimb muscle stimulation, we quantified real-time multiscale deformation of skeletal muscle tissue and nuclei. These measurements revealed reduced effective nuclear stiffness and altered load sharing between euchromatin-rich and heterochromatin-rich domains after Lamin A/C loss. Super-resolution imaging further showed that partial and complete Lamin A/C disruption uncoupled H3K9me3 from DAPI-dense heterochromatin, indicating a spatial disruption of repressive chromatin organization. Exploratory ATAC-seq suggested increased chromatin accessibility in heterozygous muscle, whereas RNA-seq showed that complete Lamin A/C loss caused broad myopathic transcriptional dysregulation while partial loss preserved a near-wild-type transcriptomic state. Integrated analysis identified HDAC2 as a candidate mechanosensitive compensatory node that may help buffer gene expression after partial Lamin A/C disruption. Together, these results establish Lamin A/C as an in vivo coordinator of nuclear mechanics, heterochromatin organization, and transcriptional homeostasis in skeletal muscle.
- Open Access
Granular Extracellular Matrix (gECM) Hydrogel Wafers as Shelf-Stable 2.5D Substrates for Microphysiological Modeling
Understanding disease pathology and evaluating emerging therapeutics require in vitro models that accurately recapitulate human tissue environments. However, existing microphysiological systems often compromise either biomimicry or ease-of-use, limiting widespread adoption and scalability. Here, we present lyophilized granular extracellular matrix (gECM) hydrogel wafers as shelf-stable, humanized 2.5D substrates that enable physiologically relevant modeling while simplifying integration into experimental workflows. Derived from decellularized human cartilage and bone, gECM hydrogel wafers retain tissue-specific architecture while introducing microporosity and surface topography through lyophilization. These wafers maintain swelling behavior, structural integrity, and mechanical properties over three months of room-temperature storage, allowing pre-fabrication and on-demand use without loss of function. gECM hydrogel wafers support direct cell seeding without encapsulation and sustain viability and proliferation of human adipose-derived mesenchymal stromal cells over 21 days, with gene expression trends comparable to 3D gECM hydrogels. Furthermore, wafers can be readily integrated into microfluidic systems with in situ hydration and transport of large biomolecules. Together, this platform bridges the gap between conventional 2D culture ease-of-use and 3D biomaterial biomimicry, providing a scalable and physiologically relevant in vitro model approach for high-throughput disease studies and therapeutic screening.
Open AccessGranular Extracellular Matrix (gECM) Hydrogel Wafers as Shelf-Stable 2.5D Substrates for Microphysiological Modeling
Understanding disease pathology and evaluating emerging therapeutics require in vitro models that accurately recapitulate human tissue environments. However, existing microphysiological systems often compromise either biomimicry or ease-of-use, limiting widespread adoption and scalability. Here, we present lyophilized granular extracellular matrix (gECM) hydrogel wafers as shelf-stable, humanized 2.5D substrates that enable physiologically relevant modeling while simplifying integration into experimental workflows. Derived from decellularized human cartilage and bone, gECM hydrogel wafers retain tissue-specific architecture while introducing microporosity and surface topography through lyophilization. These wafers maintain swelling behavior, structural integrity, and mechanical properties over three months of room-temperature storage, allowing pre-fabrication and on-demand use without loss of function. gECM hydrogel wafers support direct cell seeding without encapsulation and sustain viability and proliferation of human adipose-derived mesenchymal stromal cells over 21 days, with gene expression trends comparable to 3D gECM hydrogels. Furthermore, wafers can be readily integrated into microfluidic systems with in situ hydration and transport of large biomolecules. Together, this platform bridges the gap between conventional 2D culture ease-of-use and 3D biomaterial biomimicry, providing a scalable and physiologically relevant in vitro model approach for high-throughput disease studies and therapeutic screening.
- Open Access
Multi-step femtosecond laser-fabricated membranes for regulated migration of biomolecules and cells
Organ-on-chip (OoC) systems enable the recapitulation of key structural and functional characteristics of human tissues within controlled micro-engineered environments. In mechanically active tissues such as musculoskeletal, cardiac, and vascular systems, the incorporation of dynamic physical forces is essential for replicating the biomechanical cues governing cellular morphology and functional responses in-vivo . Without such stimuli, OoC models may fail to capture physiologically relevant tissue behaviors. Porous and semi-permeable membranes are critical components of OoCs, facilitating selective transport of nutrients, gases, and signaling molecules between cellular compartments to support biologically accurate barrier replication. Hence, fabrication strategies that permit precise modulation of membrane permeability are desirable to accommodate for the varying needs in pore size and porosity across organ systems. This study presents a two-stage fabrication process for stretchable, microporous polydimethylsiloxane (PDMS) membranes using femtosecond (fs-) pulse laser drilling. The laser-ablated pores exhibit a characteristic conical morphology, with diameters tapering from the laser entry to exit point. By modulating laser power and number of pulses, 6-15 μm exit-end pore diameters were achieved in 50 μm thick PDMS films. The membranes demonstrated strong mechanical resilience, with a 5–12% reduction in Young’s modulus after 500 cycles of strain loading. Furthermore, membranes fabricated at lower laser powers exhibited superior retention of elasticity, highlighting the influence of processing parameters on mechanical behavior. Cytocompatibility and permeability assessments confirmed that the membranes supported sustained cell viability and proliferation over at least three days. In size-restricted membrane pore geometries, cellular migration was constrained without any inhibition of biomolecular transport. This selective permeability is critical in multilayer OoC architectures, where a balance between biomolecular diffusion and cellular compartmentalization is necessary to preserve distinct tissue interfaces and functional organization. This work presents fs-laser micro-drilling as a robust and tunable fabrication strategy for producing mechanically resilient, selectively permeable PDMS membranes for physiologically relevant OoC applications.
Open AccessMulti-step femtosecond laser-fabricated membranes for regulated migration of biomolecules and cells
Organ-on-chip (OoC) systems enable the recapitulation of key structural and functional characteristics of human tissues within controlled micro-engineered environments. In mechanically active tissues such as musculoskeletal, cardiac, and vascular systems, the incorporation of dynamic physical forces is essential for replicating the biomechanical cues governing cellular morphology and functional responses in-vivo . Without such stimuli, OoC models may fail to capture physiologically relevant tissue behaviors. Porous and semi-permeable membranes are critical components of OoCs, facilitating selective transport of nutrients, gases, and signaling molecules between cellular compartments to support biologically accurate barrier replication. Hence, fabrication strategies that permit precise modulation of membrane permeability are desirable to accommodate for the varying needs in pore size and porosity across organ systems. This study presents a two-stage fabrication process for stretchable, microporous polydimethylsiloxane (PDMS) membranes using femtosecond (fs-) pulse laser drilling. The laser-ablated pores exhibit a characteristic conical morphology, with diameters tapering from the laser entry to exit point. By modulating laser power and number of pulses, 6-15 μm exit-end pore diameters were achieved in 50 μm thick PDMS films. The membranes demonstrated strong mechanical resilience, with a 5–12% reduction in Young’s modulus after 500 cycles of strain loading. Furthermore, membranes fabricated at lower laser powers exhibited superior retention of elasticity, highlighting the influence of processing parameters on mechanical behavior. Cytocompatibility and permeability assessments confirmed that the membranes supported sustained cell viability and proliferation over at least three days. In size-restricted membrane pore geometries, cellular migration was constrained without any inhibition of biomolecular transport. This selective permeability is critical in multilayer OoC architectures, where a balance between biomolecular diffusion and cellular compartmentalization is necessary to preserve distinct tissue interfaces and functional organization. This work presents fs-laser micro-drilling as a robust and tunable fabrication strategy for producing mechanically resilient, selectively permeable PDMS membranes for physiologically relevant OoC applications.
- Open Access
Granular Extracellular Matrix (gECM) Hydrogels Enable Distinct Composition and Mechanics Across Tissue Types for Translation
Biomaterials-based tissue engineering aims to recapitulate native tissue architecture and function for both clinical repair and advanced in vitro models. While improvements in biomaterials have been made, including granular hydrogels and ECM-derived scaffolds, current biomaterials lack intentional design choices for effective translation, including regulatory considerations, practical extrusion delivery, and biomimetic characteristics. Here, we develop and characterize a library of granular ECM (gECM) biomaterials for five key tissues (cartilage, bone, skin, liver, and kidney), in which ECM particles are densely packed within a hyaluronic acid hydrogel. We optimize tissue processing methods that preserve proteomic content and structure while also aligning with scale-up manufacturing and regulatory guidelines. We show that gECM hydrogels can be molded, extruded, and 3D-printed while retaining their shape, and they stabilize at physiological temperature and pH. Lastly, we demonstrate that bulk gECM mechanics are driven by tissue type, and gECM hydrogels support viability, proliferation, and tissue-specific cellular activity. Together, these findings establish gECM hydrogels as a translational and biomimetic platform for clinical tissue repair and complex in vitro models.
Open AccessGranular Extracellular Matrix (gECM) Hydrogels Enable Distinct Composition and Mechanics Across Tissue Types for Translation
Biomaterials-based tissue engineering aims to recapitulate native tissue architecture and function for both clinical repair and advanced in vitro models. While improvements in biomaterials have been made, including granular hydrogels and ECM-derived scaffolds, current biomaterials lack intentional design choices for effective translation, including regulatory considerations, practical extrusion delivery, and biomimetic characteristics. Here, we develop and characterize a library of granular ECM (gECM) biomaterials for five key tissues (cartilage, bone, skin, liver, and kidney), in which ECM particles are densely packed within a hyaluronic acid hydrogel. We optimize tissue processing methods that preserve proteomic content and structure while also aligning with scale-up manufacturing and regulatory guidelines. We show that gECM hydrogels can be molded, extruded, and 3D-printed while retaining their shape, and they stabilize at physiological temperature and pH. Lastly, we demonstrate that bulk gECM mechanics are driven by tissue type, and gECM hydrogels support viability, proliferation, and tissue-specific cellular activity. Together, these findings establish gECM hydrogels as a translational and biomimetic platform for clinical tissue repair and complex in vitro models.
- Open Access
Flowable Grafts Made from Granular Extracellular Matrix (gECM) Hydrogels Promote Integrative Repair of Articular Cartilage in a Large-Animal Model
Focal injuries to articular cartilage in load-bearing joints fail to heal and often progress to degeneration, underscoring the need for repair strategies that result in restored cartilage structure and function rather than fibrocartilage formation. Granular extracellular matrix (gECM) hydrogels, flowable grafts composed of densely-packed matrix particles, offer a promising approach but lack long-term functional validation in large-animal models. Here, we developed a flowable gECM hydrogel composed of decellularized cartilage microparticles incorporated within a thiol-functionalized hyaluronan matrix. Proteomic analysis confirmed enrichment of cartilage-specific gECM matrisome components. When implanted into critical-sized femoral condyle defects in a goat model and evaluated 12 months post-implantation, both gECM hydrogel and microdrilling (surgical controls) achieved >80% defect filling. However, in contrast to microdrilling, gECM repair tissue exhibited surface tribological (friction, adhesion) and compressive mechanical properties comparable to native cartilage, with a similar proteoglycan-to-collagen ratio, enrichment of type II collagen, minimal type I collagen (typical of a fibrous scar), improved quantitative MRI metrics, and evidence of lateral cartilage integration and subchondral bone remodeling. Together, these findings demonstrate that a flowable gECM hydrogel supports integrative, cartilage-like repair in a load-bearing joint, supporting advancement of this approach toward clinical translation. One Sentence Summary: A granular ECM hydrogel implanted in a goat condyle provided a robust repair, filling the defect tissue with integrated, hyaline-like cartilage at 12 months.
Open AccessFlowable Grafts Made from Granular Extracellular Matrix (gECM) Hydrogels Promote Integrative Repair of Articular Cartilage in a Large-Animal Model
Focal injuries to articular cartilage in load-bearing joints fail to heal and often progress to degeneration, underscoring the need for repair strategies that result in restored cartilage structure and function rather than fibrocartilage formation. Granular extracellular matrix (gECM) hydrogels, flowable grafts composed of densely-packed matrix particles, offer a promising approach but lack long-term functional validation in large-animal models. Here, we developed a flowable gECM hydrogel composed of decellularized cartilage microparticles incorporated within a thiol-functionalized hyaluronan matrix. Proteomic analysis confirmed enrichment of cartilage-specific gECM matrisome components. When implanted into critical-sized femoral condyle defects in a goat model and evaluated 12 months post-implantation, both gECM hydrogel and microdrilling (surgical controls) achieved >80% defect filling. However, in contrast to microdrilling, gECM repair tissue exhibited surface tribological (friction, adhesion) and compressive mechanical properties comparable to native cartilage, with a similar proteoglycan-to-collagen ratio, enrichment of type II collagen, minimal type I collagen (typical of a fibrous scar), improved quantitative MRI metrics, and evidence of lateral cartilage integration and subchondral bone remodeling. Together, these findings demonstrate that a flowable gECM hydrogel supports integrative, cartilage-like repair in a load-bearing joint, supporting advancement of this approach toward clinical translation. One Sentence Summary: A granular ECM hydrogel implanted in a goat condyle provided a robust repair, filling the defect tissue with integrated, hyaline-like cartilage at 12 months.