Andrea Scorzoni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Andrea Scorzoni has a total of 843 co-authors. Here are the top co-authors by number of shared publications:
P. Placidi
Istituto Nazionale di Fisica Nucleare, Sezione di Perugia, Perugia, Italy; Dip. Ingegneria Informatica ed Elettronica, Universitá degli Studi di Perugia, Perugia, Italy
30 shared publications- Ilaria De Munari
University of Parma
25 shared publications - Fausto Fantini
Department of Information Engineering, University of Modena and Reggio Emilia, Modena, Italy
19 shared publications - Leonello Servoli
INFN Sezione di Perugia, Perugia, Italy
19 shared publications - Stefano Zampolli
National Research Council, Institute for Nanostructured Materials (CNR-ISMN), Bologna Section, Via Piero Gobetti 101, 40129 Bologna, Italy
19 shared publications - Daniele Passeri
INFN Sezione di Perugia, Via Pascoli s.n.c., 06123 Perugia
16 shared publications
Latest Publications
- Open Access
- 13 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
Design of a Capacitive Probe for Laboratory Analysis of Dry and Wet Soil Electrical Properties
Understanding soil electrical properties is essential for estimating the soil water content and salinity through electrical measurements on properly designed sensors. In recent years, several low-cost soil water content sensors have been developed for geotechnical and agronomic applications, but for their validation, a characterization process is required. This is typically performed with liquids whose electrical properties are well-documented in the literature. Conversely, the electrical properties of soil are inherently unknown a priori, as they are influenced by a wide range of environmental and physical factors. This work presents a new system based on cylindrical capacitors that can be used to estimate the soil electrical properties in both wet and dry conditions. The analytical model adopted for the estimation is derived from Gauss’s Law. Its accuracy is validated against Finite Element Method (FEM) simulations, showing excellent agreement (R2 = 0.9999). The impact of the electrode insulating coating in the design is also evaluated and measurements at low frequency, 10–100 kHz range, are performed in ground coffee samples.
- 13 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
Open AccessDesign of a Capacitive Probe for Laboratory Analysis of Dry and Wet Soil Electrical Properties
Understanding soil electrical properties is essential for estimating the soil water content and salinity through electrical measurements on properly designed sensors. In recent years, several low-cost soil water content sensors have been developed for geotechnical and agronomic applications, but for their validation, a characterization process is required. This is typically performed with liquids whose electrical properties are well-documented in the literature. Conversely, the electrical properties of soil are inherently unknown a priori, as they are influenced by a wide range of environmental and physical factors. This work presents a new system based on cylindrical capacitors that can be used to estimate the soil electrical properties in both wet and dry conditions. The analytical model adopted for the estimation is derived from Gauss’s Law. Its accuracy is validated against Finite Element Method (FEM) simulations, showing excellent agreement (R2 = 0.9999). The impact of the electrode insulating coating in the design is also evaluated and measurements at low frequency, 10–100 kHz range, are performed in ground coffee samples.
- Open Access
- 13 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Measurement-Based Model for Water Content Estimation in Sustainable Granular Materials Using an IoT Custom Device
Soil water content (SWC) has a primary importance in several scientific fields involving the geotechnical, hydrological agronomic, ecological, and biological properties of the soil mass. In recent years, several techniques for determining SWC in the laboratory and situ have been proposed and developed. Applying these techniques and adopted measurement systems to different soil types is widely discussed in the literature, thus highlighting a nontrivial issue deserving further experimental research. This article presents the results of applying a capacitive sensor originally developed for SWC measurement to sustainable granular materials. In particular, the application regards coffee ground samples with two grain size distributions prepared dry and at increasing gravimetric water content (GWC) at different initial void ratios. This article presents a measurement-based analytical model for estimating the water content using low-cost low-frequency Internet of Things (IoT) sensors. The proposed model estimates the water content exploiting both capacitance and conductance measurements of the parallel electrical model. The obtained results show that including conductance measurements improves the water content estimation with respect to using capacitance measurements only.
- 13 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Open AccessMeasurement-Based Model for Water Content Estimation in Sustainable Granular Materials Using an IoT Custom Device
Soil water content (SWC) has a primary importance in several scientific fields involving the geotechnical, hydrological agronomic, ecological, and biological properties of the soil mass. In recent years, several techniques for determining SWC in the laboratory and situ have been proposed and developed. Applying these techniques and adopted measurement systems to different soil types is widely discussed in the literature, thus highlighting a nontrivial issue deserving further experimental research. This article presents the results of applying a capacitive sensor originally developed for SWC measurement to sustainable granular materials. In particular, the application regards coffee ground samples with two grain size distributions prepared dry and at increasing gravimetric water content (GWC) at different initial void ratios. This article presents a measurement-based analytical model for estimating the water content using low-cost low-frequency Internet of Things (IoT) sensors. The proposed model estimates the water content exploiting both capacitance and conductance measurements of the parallel electrical model. The obtained results show that including conductance measurements improves the water content estimation with respect to using capacitance measurements only.
- Open Access
- 25 September 2024
- Published by MDPI AG in Nanomaterials
- Vol. 14 (19) , 1551
Mobility Gaps of Hydrogenated Amorphous Silicon Related to Hydrogen Concentration and Its Influence on Electrical Performance
This paper presents a comprehensive study of hydrogenated amorphous silicon (a-Si)-based detectors, utilizing electrical characterization, Raman spectroscopy, photoemission, and inverse photoemission techniques. The unique properties of a-Si have sparked interest in its application for radiation detection in both physics and medicine. Although amorphous silicon (a-Si) is inherently a highly defective material, hydrogenation significantly reduces defect density, enabling its use in radiation detector devices. Spectroscopic measurements provide insights into the intricate relationship between the structure and electronic properties of a-Si, enhancing our understanding of how specific configurations, such as the choice of substrate, can markedly influence detector performance. In this study, we compare the performance of a-Si detectors deposited on two different substrates: crystalline silicon (c-Si) and flexible Kapton. Our findings suggest that detectors deposited on Kapton exhibit reduced sensitivity, despite having comparable noise and leakage current levels to those on crystalline silicon. We hypothesize that this discrepancy may be attributed to the substrate material, differences in film morphology, and/or the alignment of energy levels. Further measurements are planned to substantiate these hypotheses.
- 25 September 2024
- Published by MDPI AG in Nanomaterials
- Vol. 14 (19) , 1551
Open AccessMobility Gaps of Hydrogenated Amorphous Silicon Related to Hydrogen Concentration and Its Influence on Electrical Performance
This paper presents a comprehensive study of hydrogenated amorphous silicon (a-Si)-based detectors, utilizing electrical characterization, Raman spectroscopy, photoemission, and inverse photoemission techniques. The unique properties of a-Si have sparked interest in its application for radiation detection in both physics and medicine. Although amorphous silicon (a-Si) is inherently a highly defective material, hydrogenation significantly reduces defect density, enabling its use in radiation detector devices. Spectroscopic measurements provide insights into the intricate relationship between the structure and electronic properties of a-Si, enhancing our understanding of how specific configurations, such as the choice of substrate, can markedly influence detector performance. In this study, we compare the performance of a-Si detectors deposited on two different substrates: crystalline silicon (c-Si) and flexible Kapton. Our findings suggest that detectors deposited on Kapton exhibit reduced sensitivity, despite having comparable noise and leakage current levels to those on crystalline silicon. We hypothesize that this discrepancy may be attributed to the substrate material, differences in film morphology, and/or the alignment of energy levels. Further measurements are planned to substantiate these hypotheses.
- Open Access
- 8 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-13
Low-Cost and Low-Frequency Impedance Meter for Soil Water Content Measurement in the Precision Agriculture Scenario
The use of low-cost embedded devices with ubiquitous connectivity systems is a possible strategy to monitor the consumption of water used in agriculture even in countries that do not have good economic resources. In this paper, we propose a low-cost system based on a measuring approach of capacitive soil water content sensors never explored previously. This solution takes advantage of the sensor properties to respond to the need to measure at the same time salinity and soil volumetric water content. For this purpose, a bi-functional system based on a modified commercial capacitive sensor and an AD5933 impedance converter integrated circuit is described. The considered frequency range for impedance measurements is 10-100 kHz, which is a “low-frequency” range compared with typical operating frequencies of professional systems devoted to water content measurements. Measurements are carried out to check the system accuracy and to characterize the impedance of the sensor both in the air and in water, which represent the two boundaries of possible operating conditions in physical soils in terms of the real part of the electrical permittivity. Variations of the imaginary part of the electrical permittivity are taken into account using water with conductivity between 1 and 2300 μS/cm. Experimental results are compared with the measurements obtained by using a laboratory LCR meter and a maximum error of +6.12% for the capacitance and +5.6% for the conductance is obtained. The proposed system is also employed to characterize silica sandy soil with different water contents and conductivities showing quite promising results useful to overcome the well-known limits of low-cost soil water content sensors.
- 8 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-13
Open AccessLow-Cost and Low-Frequency Impedance Meter for Soil Water Content Measurement in the Precision Agriculture Scenario
The use of low-cost embedded devices with ubiquitous connectivity systems is a possible strategy to monitor the consumption of water used in agriculture even in countries that do not have good economic resources. In this paper, we propose a low-cost system based on a measuring approach of capacitive soil water content sensors never explored previously. This solution takes advantage of the sensor properties to respond to the need to measure at the same time salinity and soil volumetric water content. For this purpose, a bi-functional system based on a modified commercial capacitive sensor and an AD5933 impedance converter integrated circuit is described. The considered frequency range for impedance measurements is 10-100 kHz, which is a “low-frequency” range compared with typical operating frequencies of professional systems devoted to water content measurements. Measurements are carried out to check the system accuracy and to characterize the impedance of the sensor both in the air and in water, which represent the two boundaries of possible operating conditions in physical soils in terms of the real part of the electrical permittivity. Variations of the imaginary part of the electrical permittivity are taken into account using water with conductivity between 1 and 2300 μS/cm. Experimental results are compared with the measurements obtained by using a laboratory LCR meter and a maximum error of +6.12% for the capacitance and +5.6% for the conductance is obtained. The proposed system is also employed to characterize silica sandy soil with different water contents and conductivities showing quite promising results useful to overcome the well-known limits of low-cost soil water content sensors.
- Open Access
- 4 October 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (19) , 3466
High-Resolution Photoemission Study of Neutron-Induced Defects in Amorphous Hydrogenated Silicon Devices
In this paper, by means of high-resolution photoemission, soft X-ray absorption and atomic force microscopy, we investigate, for the first time, the mechanisms of damaging, induced by neutron source, and recovering (after annealing) of p-i-n detector devices based on hydrogenated amorphous silicon (a-Si:H). This investigation will be performed by mean of high-resolution photoemission, soft X-Ray absorption and atomic force microscopy. Due to dangling bonds, the amorphous silicon is a highly defective material. However, by hydrogenation it is possible to reduce the density of the defect by several orders of magnitude, using hydrogenation and this will allow its usage in radiation detector devices. The investigation of the damage induced by exposure to high energy irradiation and its microscopic origin is fundamental since the amount of defects determine the electronic properties of the a-Si:H. The comparison of the spectroscopic results on bare and irradiated samples shows an increased degree of disorder and a strong reduction of the Si-H bonds after irradiation. After annealing we observe a partial recovering of the Si-H bonds, reducing the disorder in the Si (possibly due to the lowering of the radiation-induced dangling bonds). Moreover, effects in the uppermost coating are also observed by spectroscopies.
- 4 October 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (19) , 3466
Open AccessHigh-Resolution Photoemission Study of Neutron-Induced Defects in Amorphous Hydrogenated Silicon Devices
In this paper, by means of high-resolution photoemission, soft X-ray absorption and atomic force microscopy, we investigate, for the first time, the mechanisms of damaging, induced by neutron source, and recovering (after annealing) of p-i-n detector devices based on hydrogenated amorphous silicon (a-Si:H). This investigation will be performed by mean of high-resolution photoemission, soft X-Ray absorption and atomic force microscopy. Due to dangling bonds, the amorphous silicon is a highly defective material. However, by hydrogenation it is possible to reduce the density of the defect by several orders of magnitude, using hydrogenation and this will allow its usage in radiation detector devices. The investigation of the damage induced by exposure to high energy irradiation and its microscopic origin is fundamental since the amount of defects determine the electronic properties of the a-Si:H. The comparison of the spectroscopic results on bare and irradiated samples shows an increased degree of disorder and a strong reduction of the Si-H bonds after irradiation. After annealing we observe a partial recovering of the Si-H bonds, reducing the disorder in the Si (possibly due to the lowering of the radiation-induced dangling bonds). Moreover, effects in the uppermost coating are also observed by spectroscopies.
- Open Access
- 8 October 2021
- Published by MDPI AG in Instruments
- Vol. 5 (4) , 32
Fabrication of a Hydrogenated Amorphous Silicon Detector in 3-D Geometry and Preliminary Test on Planar Prototypes
Hydrogenated amorphous silicon (a-Si:H) can be produced by plasma-enhanced chemical vapor deposition (PECVD) of SiH4 (silane) mixed with hydrogen. The resulting material shows outstanding radiation hardness properties and can be deposited on a wide variety of substrates. Devices employing a-Si:H technologies have been used to detect many different kinds of radiation, namely, minimum ionizing particles (MIPs), X-rays, neutrons, and ions, as well as low-energy protons and alphas. However, the detection of MIPs using planar a-Si:H diodes has proven difficult due to their unsatisfactory S/N ratio arising from a combination of high leakage current, high capacitance, and limited charge collection efficiency (50% at best for a 30 µm planar diode). To overcome these limitations, the 3D-SiAm collaboration proposes employing a 3D detector geometry. The use of vertical electrodes allows for a small collection distance to be maintained while preserving a large detector thickness for charge generation. The depletion voltage in this configuration can be kept below 400 V with a consequent reduction in the leakage current. In this paper, following a detailed description of the fabrication process, the results of the tests performed on the planar p-i-n structures made with ion implantation of the dopants and with carrier selective contacts are illustrated.
- 8 October 2021
- Published by MDPI AG in Instruments
- Vol. 5 (4) , 32
Open AccessFabrication of a Hydrogenated Amorphous Silicon Detector in 3-D Geometry and Preliminary Test on Planar Prototypes
Hydrogenated amorphous silicon (a-Si:H) can be produced by plasma-enhanced chemical vapor deposition (PECVD) of SiH4 (silane) mixed with hydrogen. The resulting material shows outstanding radiation hardness properties and can be deposited on a wide variety of substrates. Devices employing a-Si:H technologies have been used to detect many different kinds of radiation, namely, minimum ionizing particles (MIPs), X-rays, neutrons, and ions, as well as low-energy protons and alphas. However, the detection of MIPs using planar a-Si:H diodes has proven difficult due to their unsatisfactory S/N ratio arising from a combination of high leakage current, high capacitance, and limited charge collection efficiency (50% at best for a 30 µm planar diode). To overcome these limitations, the 3D-SiAm collaboration proposes employing a 3D detector geometry. The use of vertical electrodes allows for a small collection distance to be maintained while preserving a large detector thickness for charge generation. The depletion voltage in this configuration can be kept below 400 V with a consequent reduction in the leakage current. In this paper, following a detailed description of the fabrication process, the results of the tests performed on the planar p-i-n structures made with ion implantation of the dopants and with carrier selective contacts are illustrated.
- Open Access
Monitoring Soil and Ambient Parameters in the IoT Precision Agriculture Scenario: An Original Modeling Approach Dedicated to Low-Cost Soil Water Content Sensors
A low power wireless sensor network based on LoRaWAN protocol was designed with a focus on the IoT low-cost Precision Agriculture applications, such as greenhouse sensing and actuation. All subsystems used in this research are designed by using commercial components and free or open-source software libraries. The whole system was implemented to demonstrate the feasibility of a modular system built with cheap off-the-shelf components, including sensors. The experimental outputs were collected and stored in a database managed by a virtual machine running in a cloud service. The collected data can be visualized in real time by the user with a graphical interface. The reliability of the whole system was proven during a continued experiment with two natural soils, Loamy Sand and Silty Loam. Regarding soil parameters, the system performance has been compared with that of a reference sensor from Sentek. Measurements highlighted a good agreement for the temperature within the supposed accuracy of the adopted sensors and a non-constant sensitivity for the low-cost volumetric water contents (VWC) sensor. Finally, for the low-cost VWC sensor we implemented a novel procedure to optimize the parameters of the non-linear fitting equation correlating its analog voltage output with the reference VWC.
Open AccessMonitoring Soil and Ambient Parameters in the IoT Precision Agriculture Scenario: An Original Modeling Approach Dedicated to Low-Cost Soil Water Content Sensors
A low power wireless sensor network based on LoRaWAN protocol was designed with a focus on the IoT low-cost Precision Agriculture applications, such as greenhouse sensing and actuation. All subsystems used in this research are designed by using commercial components and free or open-source software libraries. The whole system was implemented to demonstrate the feasibility of a modular system built with cheap off-the-shelf components, including sensors. The experimental outputs were collected and stored in a database managed by a virtual machine running in a cloud service. The collected data can be visualized in real time by the user with a graphical interface. The reliability of the whole system was proven during a continued experiment with two natural soils, Loamy Sand and Silty Loam. Regarding soil parameters, the system performance has been compared with that of a reference sensor from Sentek. Measurements highlighted a good agreement for the temperature within the supposed accuracy of the adopted sensors and a non-constant sensitivity for the low-cost volumetric water contents (VWC) sensor. Finally, for the low-cost VWC sensor we implemented a novel procedure to optimize the parameters of the non-linear fitting equation correlating its analog voltage output with the reference VWC.
- Open Access
A Study of the Radiation Tolerance of CVD Diamond to 70 MeV Protons, Fast Neutrons and 200 MeV Pions
We measured the radiation tolerance of commercially available diamonds grown by the Chemical Vapor Deposition process by measuring the charge created by a 120 GeV hadron beam in a 50 pitch strip detector fabricated on each diamond sample before and after irradiation. We irradiated one group of samples with 70 MeV protons, a second group of samples with fast reactor neutrons (defined as energy greater than MeV), and a third group of samples with 200 MeV pions, in steps, to () × 1015 protons/cm2, () × 1016 neutrons/cm2, and () × 1014 pions/cm2, respectively. By observing the charge induced due to the separation of electron–hole pairs created by the passage of the hadron beam through each sample, on an event-by-event basis, as a function of irradiation fluence, we conclude all datasets can be described by a first-order damage equation and independently calculate the damage constant for 70 MeV protons, fast reactor neutrons, and 200 MeV pions. We find the damage constant for diamond irradiated with 70 MeV protons to be 10−18 cm2, the damage constant for diamond irradiated with fast reactor neutrons to be 10−18 cm2, and the damage constant for diamond irradiated with 200 MeV pions to be 10−18 cm2. The damage constants from this measurement were analyzed together with our previously published 24 GeV proton irradiation and 800 MeV proton irradiation damage constant data to derive the first comprehensive set of relative damage constants for Chemical Vapor Deposition diamond. We find 70 MeV protons are 2.60 ± 0.29 times more damaging than 24 GeV protons, fast reactor neutrons are 4.3 ± 0.4 times more damaging than 24 GeV protons, and 200 MeV pions are 3.2 ± 0.8 more damaging than 24 GeV protons. We also observe the measured data can be described by a universal damage curve for all proton, neutron, and pion irradiations we performed of Chemical Vapor Deposition diamond. Finally, we confirm the spatial uniformity of the collected charge increases with fluence for polycrystalline Chemical Vapor Deposition diamond, and this effect can also be described by a universal curve.Open AccessA Study of the Radiation Tolerance of CVD Diamond to 70 MeV Protons, Fast Neutrons and 200 MeV Pions
We measured the radiation tolerance of commercially available diamonds grown by the Chemical Vapor Deposition process by measuring the charge created by a 120 GeV hadron beam in a 50 pitch strip detector fabricated on each diamond sample before and after irradiation. We irradiated one group of samples with 70 MeV protons, a second group of samples with fast reactor neutrons (defined as energy greater than MeV), and a third group of samples with 200 MeV pions, in steps, to () × 1015 protons/cm2, () × 1016 neutrons/cm2, and () × 1014 pions/cm2, respectively. By observing the charge induced due to the separation of electron–hole pairs created by the passage of the hadron beam through each sample, on an event-by-event basis, as a function of irradiation fluence, we conclude all datasets can be described by a first-order damage equation and independently calculate the damage constant for 70 MeV protons, fast reactor neutrons, and 200 MeV pions. We find the damage constant for diamond irradiated with 70 MeV protons to be 10−18 cm2, the damage constant for diamond irradiated with fast reactor neutrons to be 10−18 cm2, and the damage constant for diamond irradiated with 200 MeV pions to be 10−18 cm2. The damage constants from this measurement were analyzed together with our previously published 24 GeV proton irradiation and 800 MeV proton irradiation damage constant data to derive the first comprehensive set of relative damage constants for Chemical Vapor Deposition diamond. We find 70 MeV protons are 2.60 ± 0.29 times more damaging than 24 GeV protons, fast reactor neutrons are 4.3 ± 0.4 times more damaging than 24 GeV protons, and 200 MeV pions are 3.2 ± 0.8 more damaging than 24 GeV protons. We also observe the measured data can be described by a universal damage curve for all proton, neutron, and pion irradiations we performed of Chemical Vapor Deposition diamond. Finally, we confirm the spatial uniformity of the collected charge increases with fluence for polycrystalline Chemical Vapor Deposition diamond, and this effect can also be described by a universal curve. - Open Access
Characterization of Low-Cost Capacitive Soil Moisture Sensors for IoT Networks
The rapid development and wide application of the IoT (Internet of Things) has pushed toward the improvement of current practices in greenhouse technology and agriculture in general, through automation and informatization. The experimental and accurate determination of soil moisture is a matter of great importance in different scientific fields, such as agronomy, soil physics, geology, hydraulics, and soil mechanics. This paper focuses on the experimental characterization of a commercial low-cost “capacitive” coplanar soil moisture sensor that can be housed in distributed nodes for IoT applications. It is shown that at least for a well-defined type of soil with a constant solid matter to volume ratio, this type of capacitive sensor yields a reliable relationship between output voltage and gravimetric water content.
Open AccessCharacterization of Low-Cost Capacitive Soil Moisture Sensors for IoT Networks
The rapid development and wide application of the IoT (Internet of Things) has pushed toward the improvement of current practices in greenhouse technology and agriculture in general, through automation and informatization. The experimental and accurate determination of soil moisture is a matter of great importance in different scientific fields, such as agronomy, soil physics, geology, hydraulics, and soil mechanics. This paper focuses on the experimental characterization of a commercial low-cost “capacitive” coplanar soil moisture sensor that can be housed in distributed nodes for IoT applications. It is shown that at least for a well-defined type of soil with a constant solid matter to volume ratio, this type of capacitive sensor yields a reliable relationship between output voltage and gravimetric water content.
- Open Access
- 8 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 459
Evaluation of MOX Sensor Characteristics in Ultra-Low Power Operation Modes: Application to a Semi-Passive RFID Tag for Food Logistics
Most of the battery powered systems with integrated sensors need low power consumption modes to enlarge the operation time. In the case of the fruit logistic chain, the fruit quality may be controlled by the detection of some gases as ethylene, acetaldehyde and ammonia, that are related to maturation, oxygen stress and refrigeration leakage. We report the integration of an ultra-low power (ULP) metal oxide (MOX) sensor array inside a Radio Frequency IDentification (RFID) 13.56 MHz ISO/IEC 15693 compliant tag with temperature, humidity and light sensors and data logging capabilities. Pulsed Temperature Operation (PTO), which consists in switching on and off the sensor heater, was used to reduce power consumption more than three orders of magnitude, from 14 mW down to 7 μW. The sensor behavior was characterized in terms sensitivity for ammonia.
- 8 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 459
Open AccessEvaluation of MOX Sensor Characteristics in Ultra-Low Power Operation Modes: Application to a Semi-Passive RFID Tag for Food Logistics
Most of the battery powered systems with integrated sensors need low power consumption modes to enlarge the operation time. In the case of the fruit logistic chain, the fruit quality may be controlled by the detection of some gases as ethylene, acetaldehyde and ammonia, that are related to maturation, oxygen stress and refrigeration leakage. We report the integration of an ultra-low power (ULP) metal oxide (MOX) sensor array inside a Radio Frequency IDentification (RFID) 13.56 MHz ISO/IEC 15693 compliant tag with temperature, humidity and light sensors and data logging capabilities. Pulsed Temperature Operation (PTO), which consists in switching on and off the sensor heater, was used to reduce power consumption more than three orders of magnitude, from 14 mW down to 7 μW. The sensor behavior was characterized in terms sensitivity for ammonia.