AMAndrey Mezerya

Andrey Mezerya

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andrey Mezerya has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design of neural network predictive speed control for a two-mass electromechanical system

    by Gennadii Kaniuk, Tetiana Vasylets, Oleksiy Varfolomiyev, Andrii Mezerya, Olena Blyznychenko

    Transient processes have been investigated in this study in a two-mass electromechanical system with an elastic kinematic connection, operating under conditions of variable load and significant inertial-elastic interactions between the drive elements. The task addressed relates to significant deterioration in the quality of transient processes when using classical PI controllers, manifested in large overshoots, oscillations, and increased dynamic loads on the mechanical elements of the system. This work proposes NN Predictive Controller – a neural network predictive controller, built on the basis of a neural network model of the object and the principles of predictive control. The model and control system are implemented in the MATLAB/Simulink environment. The simulation results showed that in the classical system, there is an overshoot of the actuator speed of about 98% while the control time exceeds 10 s. In the system with a neural network controller, there is no overshoot, and the control time is reduced to 3 s. The improved dynamics are explained by the ability of the neural network to take into account the prediction of the object's behavior and form a control signal taking into account future changes in the system state. This allows for effective suppression of oscillatory processes characteristic of two-mass mechanical structures. A distinctive feature of the approach is the combination of neural network identification and predictive control without the need for a complex analytical model of the object, which increases the adaptability of the system under variable operating conditions. Practical significance relates to the possibility of applying the proposed approach in control systems for electric drives whose mechanical part contains elastic kinematic linkages, where the requirements for the quality of transient processes, speed of operation, and reduction of dynamic loads are critical

  • ENHANCING THE INTEGRATED QUALITY INDEX OF PUMPS AND COMPRESSORS THROUGH CONTROL SYSTEM OPTIMIZATION

    by Gennadii Kanjuk, Oleksandr Kupriyanov, Andrii Mezerya, Volodymyr Sabadash, Tetiana Vasilets

    The relevance of the study is due to the need to improve the energy efficiency, reliability, and operational stability of pumping and compressor units, which is an important task in modern energy and industry, since automatic control systems largely determine the dynamic characteristics of the units, the level of energy consumption, operating stability, and service life. The aim of the article is to establish the relationship between the quality of the control system and the integrated quality index of pumps and compressors, as well as to assess the possibilities of improving this index by optimizing controller parameters. The research methods are based on the use of second-order mathematical models of pumps and compressors, taking into account drive characteristics, hydraulic nonlinearities, and actuator saturation. Control quality was evaluated using the integral criteria ISE, IAE, ITAE, and the integrated KPI index combining the energetic, dynamic, and durability-related properties of the unit. The study included simulation of the characteristics of a real pump, approximation of its energy and power dependencies, and analysis of transient processes under different PID controller settings. The results showed that non-optimal control algorithms cause overshoot, oscillations, increased thermal and mechanical loading of the drive, as well as higher energy consumption. Optimization of controller parameters provides a faster aperiodic transient response, reduces the integral error, increases efficiency, and decreases power consumption. It was concluded that improving automatic control systems is an effective and economically feasible way to enhance the integrated quality index of pumps and compressors without changing their design.

  • ANALYSIS OF THE IMPACT OF QUALITY INDICATORS ON THE OPERATIONAL EFFICIENCY OF POWER PLANT ENERGY EQUIPMENT

    by A. Мezerya, T. Fursova, O. Bliznichenko, V. Maliuta, O. Tolstorebrov

    The article examines the influence of quality indicators of the main power plant energy equipment on the efficiency of electric and thermal energy production. It is shown that under current conditions of limited flexible generation capacity, aging power units, and increasing requirements for fuel economy, environmental safety, and operational flexibility, the assessment of energy equipment quality extends beyond the traditional analysis of nominal efficiency alone. For turbines, boilers, condensers, generators, control systems, and cooling systems, not only energy-related characteristics but also reliability, operational, lifetime, and maintenance characteristics become decisive. It is substantiated that the operational efficiency of energy equipment is formed under the influence of a set of interrelated indicators, including efficiency, specific fuel consumption, reliability, availability, capacity factor, the level of losses in auxiliary systems, thermodynamic perfection, and the stability of parameters over time. Modern studies devoted to steam turbine degradation, combustion optimization in boilers, the effect of excess air on efficiency, the exergetic distribution of losses among the main units of thermal power plants, increasing the efficiency of turbine installations under variable operating modes, improving turbogenerator cooling systems, as well as issues of equipment reliability and safe operation, are analyzed. It has been established that individual quality indicators have a quantitatively significant influence on operating performance. In particular, long-term degradation of steam turbines may cause a power loss at the level of (2-7,5)%; an increase in excess air in the boiler from 10% to 70% leads to a decrease in energy and exergetic efficiency by approximately 5%; the integration of thermal energy storage systems and the improvement of operating modes can increase maneuverability by 3-4 times and improve the profitability of a power plant. For certain turbine units, rationalization of the reheated steam temperature provided an increase in efficiency of (0,3-1,5)% and a reduction in specific equivalent fuel consumption by (3-4) g standard fuel/kWh. A system of individual quality indicators of power equipment and a comprehensive quality indicator suitable for multicriteria assessment is proposed. It is shown that the greatest impact on the integrated efficiency of power plants is exerted by the quality indicators of turbine, boiler, and condensing equipment, as well as the reliability of generators and auxiliary systems. The results can be used in technical diagnostics, modernization, optimization of operating modes, and substantiation of priorities for repair and reconstruction of power plant energy equipment.

  • Open Access

    Features of the Characteristics of Thermal Insulation Materials Used at Power Plants

    by Gennadii Kanjuk, Andrii Mezerya, Viktoria Kniazieva, Olena Bliznichenko, Tetiana Fursova

    The article examines the specific features of thermal insulation materials used at power plants, where insulation operates not under the relatively stable microclimatic conditions typical of building envelopes, but on the surfaces of steam pipelines, gas ducts, heat-exchange equipment, valves, tanks, and auxiliary systems, for which the determining factors are not only thermal conductivity under reference conditions, but also the ability to maintain structure, strength, geometric stability, and low heat flux under prolonged exposure to elevated temperatures, cyclic heating and cooling, vibration, moisture, local mechanical loads, and atmospheric factors. It is shown that, for power engineering equipment, the suitability of a thermal insulation material is determined by a set of interrelated indicators, including thermal conductivity, density, porosity, water absorption, compressive and flexural strength, thermal diffusivity, heat resistance, non-combustibility, stability under thermal cycling, and compatibility with protective claddings and installation solutions. The differences between the requirements for insulation used at power plants and those for building thermal insulation are generalized: in construction, the dominant considerations are the normative resistance of building envelopes to heat transfer, weight, cost, ease of installation, and sanitary and environmental characteristics, whereas in the power industry priority is given to operability at high temperature, low degradation of properties over time, reduction of heat losses from curved and shaped surfaces, fire safety, and maintainability under scheduled servicing conditions. The main relationships for evaluating the characteristics of thermal insulation materials and insulated elements are presented, and a comparative analysis of methods for improving quality indicators is carried out, in particular through hydrophobization, optimization of the pore structure, multilayer design, the use of aerogel-containing layers, improvement of the quality of external protective coatings, and refinement of installation technology. It is substantiated that the most promising direction for power plants is not a separate material in its pure form, but a multilayer functionally differentiated system in which the inner layer ensures minimum heat flux at high temperature, while the outer layer provides mechanical stability, hydrophobicity, and durability. The proposed generalizations may be used in the selection, design, and modernization of thermal insulation for power engineering equipment and pipeline systems.


  • IMPROVING THE PERFORMANCE INDICATORS OF SMALL HYDROPOWER PLANTS THROUGH OPTIMIZATION OF CONTROL SYSTEMS

    by А. Мezerya, S. Pridvorov

    The article addresses the problem of improving the comprehensive quality indicators of small hydropower plants by optimizing the automatic control systems of hydroelectric generating units. It is shown that, under conditions of increasing penetration of decentralized energy sources and heightened requirements for energy efficiency, the quality of dynamic processes occurring during load changes in small HPPs becomes particularly important. To solve this problem, an approach is proposed for optimizing the parameters of a PID controller within the automatic speed regulation system of a hydroturbine, based on modeling its dynamics as a second-order system with typical hydraulic and electromechanical time constants. A model of a small-capacity Francis turbine with nominal parameters – net head of 74 m, discharge of 2.05 m³/s, and nominal output of approximately 1.28 MW – is used as the research object. Generalized head, efficiency, and power characteristics of the turbine are presented. Simulation studies of the turbine’s response to step load changes were carried out for two configurations of the PID controller: non-optimal and optimized. A quantitative assessment of transient quality was performed using integral error- and time-based criteria, as well as energy efficiency indicators, including the relative loss of generated energy during the transient mode. It is demonstrated that optimal PID tuning significantly reduces the amplitude and duration of oscillations, accelerates the establishment of steady-state conditions, and decreases energy losses from 12.9% to 2.1%. A comprehensive quality index is proposed, integrating dynamic and energy criteria, which can be used as a universal metric for comparing different control strategies. The obtained results confirm the feasibility of optimizing control systems as one of the most effective ways to enhance the performance and reliability of small hydropower plants.

  • ANALYSIS OF THE REGULATORY BASE FOR ENSURING HIGH INDICATORS OF THE WORK QUALITY OF GAS PUMPING STATIONS

    by А. Мezerya, S. Nasirov

    The article presents the results of the analysis of existing regulatory support for improving the quality of work of gas pumping stations and their elements, the main of which are compressor units. It is shown that in order to ensure high quality indicators of the work of gas pumping stations and their elements, there are a number of regulatory documents that consider the issues of operation, metrology, testing, energy saving and other important areas aimed at increasing and maintaining quality indicators that must meet international standards. The main indicators of the quality of work of gas pumping stations, which are divided into technical and economic, are given. The potential of increasing energy efficiency, which is one of the main technical indicators of the quality of work, has been determined. It is shown that the potential for increasing energy efficiency is the limiting value for increasing the efficiency of gas pumping station equipment. It was established that the possibility of realizing this indicator depends on the specific conditions of the gas pipeline system, as well as on the possibility of improving the technical condition of the gas turbine installation. The shortcomings of the existing regulatory framework have been identified, namely: there is a lack of regulatory methods for creating automated control systems that guarantee high quality indicators of gas pumping stations, first of all, the efficiency ratio, which can be increased by reducing all types of energy losses. Identified tasks regarding the further improvement of regulatory support of Ukraine: in-depth theoretical and experimental research, improvement of mathematical models of the main equipment of gas pumping stations and control systems; checking the adequacy of improved mathematical models according to experimental characteristics; implementation of structural and parametric synthesis of energy-efficient control systems. For the purpose of structuring regulatory documents and finding effective directions for improving the quality indicators of gas pumping stations, a classification of existing regulatory support was developed.

  • Qualimetric Aspects of the Application of Non-metric Measurement Scales in the Energy Technology of Thermal Power Plants

    by Gennadii Kaniuk, Vasiliy Promoskal, Hanna Hrinchenko, Olena Blyznychenko, Tetiana Fursova, Andrey Mezerya

  • Enhancing the Quality of Technical and Economic Indicators of Thermal Power Plants by Improving the Combustion of Low-Grade Fuels

    by Gennadii Kaniuk, Andrey Mezerya, Tetiana Fursova, Hanna Hrinchenko, Tetiana Vasylets, Oleksandr Yepik


  • Open Access

    Ways of increase indicators of quality (heat economy) of power plants

    by G. Kanjuk, A. Mezerya, T. Fursova, D. Chyrochkin, O. Epik

    The article analyzes performance indicators of thermal and nuclear power plants, namely thermal efficiency, and identifies the main ways to improve them. It is shown that the regenerative heating of the feed water is used in all steam turbine plants and significantly increases the thermal and overall efficiency of the plants. The higher the parameters of the steam in front of the turbine, the greater the temperature range for which condensate heating can be carried out, and the greater the effect of using a scheme with regenerative heating. It was determined that the regenerative heating of the feed water in the cycle with superheated steam also increases the efficiency, but the thermal efficiency of the regenerative cycle of superheated steam is always lower than the efficiency of the Carnot cycle at the same initial and final temperatures. It has been proven that at the same temperature of the feed water, the less underheating, the greater the work of the steam selection flow and the higher the thermal efficiency of the installation, and the greatest effect from regeneration occurs when using mixing type heaters. It is shown that for turbines with back pressure, regenerative heating increases the efficiency of the installation only when it is carried out by additional consumption of steam beyond what is required for production needs. In turbines with adjustable withdrawals, regenerative withdrawals located after the industrial one, based on the same amount of steam withdrawn, have a greater impact on the efficiency, and therefore sometimes the use of regenerative heating of the feed water can lead to an increase in efficiency even with a slight decrease in the consumption of steam to the consumer. The systematization and analysis of the existing methods for assessing the thermal efficiency of power plants of various types is carried out, the influence of energy consumption on own needs on the efficiency of power plants is shown.

  • Open Access

    Decomposition of technical and economic quality indicators of power plants

    by G. Kanjuk, A. Mezerya, T. Vasilets, A. Tsvetkova-Kanyuk, O. Tolstorebrov

    The article presents a structural diagram of the decomposition of technical and economic indicators of the quality of power units of thermal and nuclear power plants and the structure of the formation of resource savings. It is shown that the specific value of energy saving in any of the elements of the power plant scheme relative to the total production of electricity by the power unit to which this element belongs can be recommended as a criterion of energy saving efficiency. Data on electricity consumption for the condensing power plant's own needs depending on the capacity of power units, initial parameters of steam and type of fuel are given. It is stated that using the methods of equivalence and decomposition in the study of energy saving, it is possible to develop structural schemes for the formation of efficiency indicators (economical, reliability, etc.) for any technological scheme (system) of an electric station depending on the consumption of primary energy. A significant negative role in solving the problems of energy and resource conservation at thermal and nuclear power plants at the expense of own needs has been identified, which consists in the lack of a methodology for determining the effectiveness of energy-saving technologies in individual systems, subsystems and elements of the technological scheme of power plants and their impact on general plant technical and economic indicators. An analysis of the share of individual units and subsystems in the consumption of electricity for own needs was carried out. The consumption of electricity for own needs is shown depending on the load and parameters of the power unit. A structural scheme for the formation of savings in the production of electricity at a power plant has been developed, which allows evaluating the efficiency and mutual influence of energy-saving technologies in any subsystem and its elements.