JGJose Gonzalez

Jose Gonzalez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jose Gonzalez has a total of 121 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Continuous volitional control of a bionic leg supports diverse walking patterns in both agonist–antagonist muscle interface and bone-anchored prosthesis users

    by Federica Damonte, Lucas Avanci Gaudio, Jose Gonzalez-Vargas, Guillaume Durandau, Jennifer Ernst, Johan S Rietman, Ruud Leijendekkers, Herman van der Kooij, Massimo Sartori

    Myoelectric control paradigms have the potential to enable continuous volitional control of bionic limbs in various movement conditions. Although individuals with below knee amputations and an agonist–antagonist muscle interface (AMI) were proven to display a greater degree of continuous volitional control in bionic ankle-foot systems with respect to conventional socket-suspended prosthetic users, it remains unclear how myoelectric interfaces could translate to non-AMI prosthetic users with bone-anchored prostheses (BAP). This preliminary study proposes a human–machine interface (HMI) based on a neuromechanical model to enable volitional, continuous myoelectric control of a bionic leg in AMI and BAP users, walking across various speeds and ground inclinations. Differently from state of the art solutions, the proposed HMI is based on a digital twin of the intact leg, synthesizing the user’s phantom limb musculoskeletal function as controlled by muscle activations measured from the residuum. When embedded in a real-time framework, it enabled the participants to achieve volitional modulation of prosthesis peak plantar-dorsiflexion torques timing and amplitude during overground walking at three speeds (between 1.6 and 3.96 km/h), with case studies provided during calf-raises (30, 45, and 60 bpm) and ramp ascent walking (3 and 5% incline). Before prosthesis control tests, the participants underwent a 2-day gait training session. Results showed that all three subjects learned how to alter initial muscle activation patterns so that an average of 87% of peak activation timing fell within target ranges. The proposed neuromechanical modeling technology opens new avenues toward generalizable HMIs for the volitional control of active prostheses beyond set conditions and amputation types.


  • Open Access

    A Bionic Foot Controlled by a Synergy-Driven Neuromechanical Model Enables Walking at Various Speeds in Socket-Suspended and Bone-Anchored Prosthesis Users

    by F. Damonte, J. Gonzalez-Vargas, G. Durandau, J. S. Rietman, R. Leijendekkers, H. van der Kooij, M. Sartori

    Human locomotion adapts to different conditions, resulting in changes in gait parameters like speed, stride time, and length. Bionic limbs strive to mimic natural walking patterns, with speed adaptation being a key feature. Research shows that myoelectric bionic legs allow individuals with agonist-antagonist myoneural interface (AMI) amputations to control speed-adaptive walking. However, those with non-AMI amputations show difficulty generating consistent electromyography (EMG) signals. Therefore, we aim to create a human-machine interface that provides speed-adaptive biomimetic behavior without relying on EMGs. Steady-state locomotion can be modeled as the sequential recruitment of muscle groups during the gait cycle. To replicate this motor control, we created a control framework for a bionic foot using a neuromechanical model driven by synthetic muscle activations, replacing EMG recordings. We tested the controller on two individuals with transtibial amputations—one with a socket-suspended prosthesis and the other with a bone-anchored prosthesis. Muscle activation peaks fell within target ranges, leading to peak plantar-flexion torques at 49% of the gait cycle. The averaged model torques aligned with those from inverse dynamics on the intact side (RMSE = 0.52 ± 0.3 (Nm/Kg), r = 0.52 ± 0.4). The results show that the control system effectively modulates joint torques in timing and amplitude for two subjects across three walking speeds (0.55 to 1.1 m/s). Designed for steady-state walking, it can modulate torque during speed transitions. This first investigation aims to prove the feasibility of a personalized biomimetic control framework for bionic limbs without relying on EMGs, supporting walking at various speeds.


  • Open Access

    The impact of walking on the perception of multichannel electrotactile stimulation in individuals with lower-limb amputation and able-bodied participants

    by Romain Valette, Jose Gonzalez-Vargas, Strahinja Dosen

    Background: One of the drawbacks of lower-limb prostheses is that they do not provide explicit somatosensory feedback to their users. Electrotactile stimulation is an attractive technology to restore such feedback because it enables compact solutions with multiple stimulation points. This allows stimulating a larger skin area to provide more information concurrently and modulate parameters spatially as well as in amplitude. However, for effective use, electrotactile stimulation needs to be calibrated and it would be convenient to perform this procedure while the subject is seated. However, amplitude and spatial perception can be affected by motion and/or physical coupling between the residual limb and the socket. In the present study, we therefore evaluated and compared the psychometric properties of multichannel electrotactile stimulation applied to the thigh/residual limb during sitting versus walking. Methods: The comprehensive assessment included the measurement of the sensation and discomfort thresholds (ST & DT), just noticeable difference (JND), number of distinct intervals (NDI), two-point discrimination threshold (2PD), and spatial discrimination performance (SD). The experiment involved 11 able-bodied participants (4 females and 7 males; 29.2 ± 3.8 years), 3 participants with transtibial amputation, and 3 participants with transfemoral amputation. Results: In able-bodied participants, the results were consistent for all the measured parameters, and they indicated that both amplitude and spatial perception became worse during walking. More specifically, ST and DT increased significantly during walking vs. sitting (2.90 ± 0.82 mA vs. 2.00 ± 0.52 mA; p < 0.001 for ST and 7.74 ± 0.84 mA vs. 7.21 ± 1.30 mA; p < 0.05 for DT) and likewise for the JND (22.47 ± 12.21% vs. 11.82 ± 5.07%; p < 0.01), while the NDI became lower (6.46 ± 3.47 vs. 11.27 ± 5.18 intervals; p < 0.01). Regarding spatial perception, 2PD was higher during walking (69.78 ± 17.66 mm vs. 57.85 ± 14.87 mm; p < 0.001), while the performance of SD was significantly lower (56.70 ± 10.02% vs. 64.55 ± 9.44%; p < 0.01). For participants with lower-limb amputation, the ST, DT, and performance in the SD assessment followed the trends observed in the able-bodied population. The results for 2PD and JND were however different and subject-specific. Conclusion: The conducted evaluation demonstrates that electrotactile feedback should be calibrated in the conditions in which it will be used (e.g., during walking). The calibration during sitting, while more convenient, might lead to an overly optimistic (or in some cases pessimistic) estimate of sensitivity. In addition, the results underline that calibration is particularly important in people affected by lower-limb loss to capture the substantial variability in the conditions of the residual limb and prosthesis setup. These insights are important for the implementation of artificial sensory feedback in lower-limb prosthetics applications.


  • Open Access

    Using embedded prosthesis sensors for clinical gait analyses in people with lower limb amputation: A feasibility study

    by Sabina Manz, Dirk Seifert, Bjoern Altenburg, Thomas Schmalz, Strahinja Dosen, Jose Gonzalez-Vargas


  • Open Access

    A review of user needs to drive the development of lower limb prostheses

    by Sabina Manz, Romain Valette, Federica Damonte, Lucas Avanci Gaudio, Jose Gonzalez-Vargas, Massimo Sartori, Strahinja Dosen, Johan Rietman

    Background: The development of bionic legs has seen substantial improvements in the past years but people with lower-limb amputation still suffer from impairments in mobility (e.g., altered balance and gait control) due to significant limitations of the contemporary prostheses. Approaching the problem from a human-centered perspective by focusing on user-specific needs can allow identifying critical improvements that can increase the quality of life. While there are several reviews of user needs regarding upper limb prostheses, a comprehensive summary of such needs for those affected by lower limb loss does not exist.Methods: We have conducted a systematic review of the literature to extract important needs of the users of lower-limb prostheses. The review included 56 articles in which a need (desire, wish) was reported explicitly by the recruited people with lower limb amputation (N = 8149).Results: An exhaustive list of user needs was collected and subdivided into functional, psychological, cognitive, ergonomics, and other domain. Where appropriate, we have also briefly discussed the developments in prosthetic devices that are related to or could have an impact on those needs. In summary, the users would like to lead an independent life and reintegrate into society by coming back to work and participating in social and leisure activities. Efficient, versatile, and stable gait, but also support to other activities (e.g., sit to stand), contribute to safety and confidence, while appearance and comfort are important for the body image. However, the relation between specific needs, objective measures of performance, and overall satisfaction and quality of life is still an open question.Conclusions: Identifying user needs is a critical step for the development of new generation lower limb prostheses that aim to improve the quality of life of their users. However, this is not a simple task, as the needs interact with each other and depend on multiple factors (e.g., mobility level, age, gender), while evolving in time with the use of the device. Hence, novel assessment methods are required that can evaluate the impact of the system from a holistic perspective, capturing objective outcomes but also overall user experience and satisfaction in the relevant environment (daily life).


  • SimBionics: Neuromechanical Simulation and Sensory Feedback for the Control of Bionic Legs

    by Jose Gonzalez-Vargas, Massimo Sartori, Strahinja Dosen, Herman van der Kooij, Johan Rietman

  • Open Access

    Control bio-inspirado para un actuador elástico por medio del algoritmo de aprendizaje por retroalimentación del error

    by José González-Vargas, Mario Rios-Mora, Juan C. Moreno, José Luis Pons-Rovira

    El presente documento abarca la mejora del esquema de control de los actuadores de rigidez variable (VSA), presentes en la articulación de la rodilla de un robot bípedo llamado Binocchio, desarrollado por el grupo de Neuro-rehabilitación del Instituto Cajal. El diseño de dicho robot se basó en varias características biológicas presentes en los seres humanos como por ejemplo la visco-elasticidad de los músculos. Para controlar estos actuadores de manera robusta y eficiente no es suficiente el uso de estrategias de control clásico basados en modelos, debido a que estos métodos no son capaces de tomar en cuenta todas las no-linealidades intrínsecas del actuador debido a su estructura mecánica y a su naturaleza elástica. Por ello se adaptó un método bio-inspirado de control conocido como Feedback Error Learning (FEL) que utiliza una red neuronal para aprender el modelo inverso sin ningún conocimiento a priori de los parámetros del actuador. Seguidamente se procedió a realizar pruebas de control para validar su implementación. Finalmente, fue posible adaptar el FEL para el control de los VSA, lo que incidió en una mejora significativa en el rendimiento de los controladores de trayectoria. Pruebas de robustez y de estabilidad permitieron validar el uso del FEL como una alternativa viable para el control de los actuadores.


  • Open Access

    Conceptualizing caregiver workload: an exploratory study guided by NASA TLX

    by R.A. Rutkowski, S. Ponnala, J. Gonzalez-Vargas, A. Gilmore-Bykovskyi, L. Block, A.J. Kind, N.E. Werner

    Persons with dementia (PwD) are heavily dependent on the support of informal, dementia caregivers to fulfill their day-to-day care needs. Dementia caregivers, often friends and family members of the PwD, are unpaid, non-professional individuals who take on many of the care responsibilities. Due to the lack of formal training, social support, and information resources, among other factors, dementia caregivers are often at risk for negative outcomes such as stress and burden. There have not been any comprehensive assessment tools to predict these negative outcomes. Therefore, we employ the NASA TLX dimensions to conceptualize caregiver workload. This study operationalizes the NASA TLX dimensions in the context of dementia caregiving and illustrates examples for each of the dimensions. The results indicate that the NASA TLX does not include all of the factors necessary to conceptualize caregiver workload and prescribe a need for developing a robust caregiver workload assessment tool.


  • Open Access

    Improving bimanual interaction with a prosthesis using semi-autonomous control

    by Robin Volkmar, Strahinja Dosen, Jose Gonzalez-Vargas, Marcus Baum, Marko Markovic

    Background: The loss of a hand is a traumatic experience that substantially compromises an individual’s capability to interact with his environment. The myoelectric prostheses are state-of-the-art (SoA) functional replacements for the lost limbs. Their overall mechanical design and dexterity have improved over the last few decades, but the users have not been able to fully exploit these advances because of the lack of effective and intuitive control. Bimanual tasks are particularly challenging for an amputee since prosthesis control needs to be coordinated with the movement of the sound limb. So far, the bimanual activities have been often neglected by the prosthetic research community. Methods: We present a novel method to prosthesis control, which uses a semi-autonomous approach in order to simplify bimanual interactions. The approach supplements the commercial SoA two-channel myoelectric control with two additional sensors. Two inertial measurement units were attached to the prosthesis and the sound hand to detect the movement of both limbs. Once a bimanual interaction is detected, the system mimics the coordination strategies of able-bodied subjects to automatically adjust the prosthesis wrist rotation (pronation, supination) and grip type (lateral, palmar) to assist the sound hand during a bimanual task. The system has been evaluated in eight able-bodied subjects performing functional uni- and bi-manual tasks using the novel method and SoA two-channel myocontrol. The outcome measures were time to accomplish the task, semi-autonomous system misclassification rate, subjective rating of intuitiveness, and perceived workload (NASA TLX). Results: The results demonstrated that the novel control interface substantially outperformed the SoA myoelectric control. While using the semi-autonomous control the time to accomplish the task and the perceived workload decreased for 25 and 27%, respectively, while the subjects rated the system as more intuitive then SoA myocontrol. Conclusions: The novel system uses minimal additional hardware (two inertial sensors) and simple processing and it is therefore convenient for practical implementation. By using the proposed control scheme, the prosthesis assists the user’s sound hand in performing bimanual interactions while decreasing cognitive burden.


  • Top Cited Papers
    Open Access

    Compliant lower limb exoskeletons: a comprehensive review on mechanical design principles

    by Maria del Carmen Sanchez-Villamañan, Jose Gonzalez-Vargas, Diego Torricelli, Juan C. Moreno, Jose L. Pons

    Exoskeleton technology has made significant advances during the last decade, resulting in a considerable variety of solutions for gait assistance and rehabilitation. The mechanical design of these devices is a crucial aspect that affects the efficiency and effectiveness of their interaction with the user. Recent developments have pointed towards compliant mechanisms and structures, due to their promising potential in terms of adaptability, safety, efficiency, and comfort. However, there still remain challenges to be solved before compliant lower limb exoskeletons can be deployed in real scenarios. In this review, we analysed 52 lower limb wearable exoskeletons, focusing on three main aspects of compliance: actuation, structure, and interface attachment components. We highlighted the drawbacks and advantages of the different solutions, and suggested a number of promising research lines. We also created and made available a set of data sheets that contain the technical characteristics of the reviewed devices, with the aim of providing researchers and end-users with an updated overview on the existing solutions.